The analysis of the impulse voltage on the internal electric field of the cable joint plays a key role in studying the breakdown of the joint. Based on the finite element method, a three-dimensional electromagnetic fi...The analysis of the impulse voltage on the internal electric field of the cable joint plays a key role in studying the breakdown of the joint. Based on the finite element method, a three-dimensional electromagnetic field simulation model of the cable joint is established in this paper. Simulation results show that the voltage at the head of the cable joint reaches about twice the impulse voltage. The increase of the conductivity of semi-conductive material also leads to the increase of electric field intensity. Then, several points and curves at different positions are selected for further analysis in this paper. Among them, the electric field distortion at the edge of the high voltage shield is the most serious and the electric field in the air gap is the least.展开更多
We conducted a study on the numerical calculation and response analysis of a transient electromagnetic field generated by a ground source in geological media. One solution method, the traditional discrete image method...We conducted a study on the numerical calculation and response analysis of a transient electromagnetic field generated by a ground source in geological media. One solution method, the traditional discrete image method, involves complex operation, and its digital filtering algorithm requires a large number of calculations. To solve these problems, we proposed an improved discrete image method, where the following are realized: the real number of the electromagnetic field solution based on the Gaver-Stehfest algorithm for approximate inversion, the exponential approximation of the objective kernel function using the Prony method, the transient electromagnetic field according to discrete image theory, and closed-form solution of the approximate coefficients. To verify the method, we tentatively calculated the transient electromagnetic field in a homogeneous model and compared it with the results obtained from the Hankel transform digital filtering method. The results show that the method has considerable accuracy and good applicability. We then used this method to calculate the transient electromagnetic field generated by a ground magnetic dipole source in a typical geoelectric model and analyzed the horizontal component response of the induced magnetic field obtained from the "ground excitation-stratum measurement method. We reached the conclusion that the horizontal component response of a transient field is related to the geoelectric structure, observation time, spatial location, and others. The horizontal component response of the induced magnetic field reflects the eddy current field distribution and its vertical gradient variation. During the detection of abnormal objects, positions with a zero or comparatively large offset were selected for the drill- hole measurements or a comparatively long observation delay was adopted to reduce the influence of the ambient field on the survey results. The discrete image method and forward calculation results in this paper can be used as references for relevant research.展开更多
This work presented the development and validation of an analytical method to predict the transient temperature field in the asphalt pavement.The governing equation for heat transfer was based on heat conduction radia...This work presented the development and validation of an analytical method to predict the transient temperature field in the asphalt pavement.The governing equation for heat transfer was based on heat conduction radiation and convection.An innovative time-dependent function was proposed to predict the pavement surface temperature with solar radiation and air temperature using dimensional analysis in order to simplify the complex heat exchange on the pavement surface.The parameters for the time-dependent pavement surface temperature function were obtained through the regression analysis of field measurement data.Assuming that the initial pavement temperature distribution was linear and the influence of the base course materials on the temperature of the upper asphalt layers was negligible,a close-form analytical solution of the temperature in asphalt layers was derived using Green's function.Finally,two numerical examples were presented to validate the model solutions with field temperature measurements.Analysis results show that the solution accuracy is in agreement with field data and the relative errors at a shallower depth are greater than those at a deeper one.Although the model is not sensitive to dramatic changes in climatic factors near the pavement surface,it is applicable for predicting pavement temperature field in cloudless days.展开更多
The on-orhit transient temperature of reflector laminate film was analyzed by using finite element method (FEM). Numerical simulation was used by FEM software ANSYS. Results reveal that the temperature levels of the...The on-orhit transient temperature of reflector laminate film was analyzed by using finite element method (FEM). Numerical simulation was used by FEM software ANSYS. Results reveal that the temperature levels of the laminate composite membrane alternate greatly in the orbital period, which is about±80℃. This range exceeds the material ' s operating temperature level. So it is necessary to put effective thermal control into effect to the laminate composite membrane. There is temperature gradient in the thickness direction of the laminate composite membrane; there is a light change in Kevlar/Epoxy layer. The temperature of the laminate composite membrane is obviously lower than the seam' s temperature. Results provide reference to the thermal control of the inflatable reflector with high precision requirement.展开更多
Based on the analysis of factors affecting transient temperature field of aircraft fuel tank and coupled heat transfer mechanism, a mathematical model of transient coupled heat transfer, including the dynamic- chan...Based on the analysis of factors affecting transient temperature field of aircraft fuel tank and coupled heat transfer mechanism, a mathematical model of transient coupled heat transfer, including the dynamic- change of fuel quality, the internal heat transfer, the external aerodynamic convection and the radiation heat transfer, is established. Taking the aerodynamic convection and radiation heat transfer outside the tank as the third kinds of thermal boundary conditions for the thermal analysis of the fuel tank, calculation of internal and external coupling heat of fuel tank is decoupled. Ther^nal network method combined with hierarchical dynamic- grid is used to deal with the fuel consumption, and carry on the heat transfer analysis of the fuel tank. The numerical method for the transient temperature field of aircraft fuel tank is established. Through the simulation calculation, the transient temperature distribution of the fuel tank under different flight conditions is obtained, and the influence of the fuel mass and the external thermal environment on the temperature field is analyzed.展开更多
To decrease thermal stress during laser metal deposition shaping(LMDS)process,it is of great importance to learn the transient thermal stress distribution regularities.Based on the“element life and death”technique o...To decrease thermal stress during laser metal deposition shaping(LMDS)process,it is of great importance to learn the transient thermal stress distribution regularities.Based on the“element life and death”technique of finite element analy- sis(FEA),a three-dimensional multi-track and multi-layer numerical simulation model for LMDS is developed with ANSYS parametric design language(APDL)for the first time,in which long-edge parallel reciprocating scanning paths is introduced. Through the model,detailed simulations of thermal stress during whole metal cladding process are conducted,the generation and distribution regularities of thermal stress are also discussed in detail.Using the same process parameters,the simulation results show good agreement with the features of samples which fabricated by LMDS.展开更多
A new method of 3D transient eddy current field calculation is proposed. The Maxwell equations with time component elimination (METCE) are derived under the assumption of magnetic quasi static approximation, especia...A new method of 3D transient eddy current field calculation is proposed. The Maxwell equations with time component elimination (METCE) are derived under the assumption of magnetic quasi static approximation, especially for the sample of low conductivity. Based on METCE, we deduce a more efficient reconstruction algorithm of a 3D transient eddy current field. The computational burden is greatly reduced through the new algorithm, and the computational efficiency is improved. This new algorithm decompounds the space-time variables into two individual variables. The idea is to solve the spatial vector component firstly, and then multiply it by the corresponded time component. The iterative methods based on METCE are introduced to recover the distribution of conductivity in magneto-acoustic tomography. The reconstructed images of conductivity are consistent with the original distribution, which validate the new method.展开更多
One of the primary reasons leading to bulging and cracking in a coke drum is the severe temperature gradient due to cyclic temperature variation. Based on the twodimensional heat conduction theory, an analytical solut...One of the primary reasons leading to bulging and cracking in a coke drum is the severe temperature gradient due to cyclic temperature variation. Based on the twodimensional heat conduction theory, an analytical solution of the transient temperature field in the coke drum is obtained, which is different from the known FEM results. The length of the coke drum is considered finite. The dynamic boundary conditions caused by fluid uninterrupted rising in oiling and watering stages are simulated with the iteration method. Numerical results show that the present theoretical model can accurately describe basic features of the transient temperature field in the coke drum. Effects of the geometry of the coke drum and the rising velocity of quench water on the axial temperature gradient are also discussed.展开更多
In gas insulation switch(GIS)substation,secondary devices such as linemonitoring devices are placed in the switching field,and these electronic devices are vulnerable to transient electromagnetic interference caused b...In gas insulation switch(GIS)substation,secondary devices such as linemonitoring devices are placed in the switching field,and these electronic devices are vulnerable to transient electromagnetic interference caused by switching operation.In order to facilitate the measurement and research of electromagnetic disturbance data under different working conditions,a simulation test device is developed in this paper,which can be used to simulate electromagnetic disturbance of GIS substation sensor and secondary device port under switch operation.A four-channel parallel gas switch was designed,and the main characteristic parameters of electromagnetic disturbance generated by the simulation device were measured by using high-frequency pulse power supply as the excitation source.The comparison between the measured waveform and the measured disturbance characteristic parameters of GIS substation shows that it is in good agreement with the measured waveform characteristics,conforms to the basic characteristics of damped oscillation wave,and can be used in the secondary equipment port disturbance voltage coupling characteristics,protection measures evaluation and assessment method research.展开更多
Our experiment shows that the dust grains, suspended on the edge of the sheath of a radio-frequency discharge, undergo a contraction when switching a vertical magnetic field on, and an expansion when switching the mag...Our experiment shows that the dust grains, suspended on the edge of the sheath of a radio-frequency discharge, undergo a contraction when switching a vertical magnetic field on, and an expansion when switching the magnetic field off. We call this kind of magnetic field "transient magnetic field". A primary analysis is proposed for the phenomenon.展开更多
We calculate the multicomponent responses of surface-hole transient electromagnetic method. The methods and models are unsuitable as geoelectric models of conductive surrounding rocks because they are based on regular...We calculate the multicomponent responses of surface-hole transient electromagnetic method. The methods and models are unsuitable as geoelectric models of conductive surrounding rocks because they are based on regular local targets. We also propose a calculation and analysis scheme based on numerical simulations of the subsurface transient electromagnetic fields. In the modeling of the electromagnetic fields, the forward modeling simulations are performed by using the finite-difference time-domain method and the discrete image method, which combines the Gaver–Stehfest inverse Laplace transform with the Prony method to solve the initial electromagnetic fields. The precision in the iterative computations is ensured by using the transmission boundary conditions. For the response analysis, we customize geoelectric models consisting of near-borehole targets and conductive wall rocks and implement forward modeling simulations. The observed electric fields are converted into induced electromotive force responses using multicomponent observation devices. By comparing the transient electric fields and multicomponent responses under different conditions, we suggest that the multicomponent-induced electromotive force responses are related to the horizontal and vertical gradient variations of the transient electric field at different times. The characteristics of the response are determined by the varying the subsurface transient electromagnetic fields, i.e., diffusion, attenuation and distortion, under different conditions as well as the electromagnetic fields at the observation positions. The calculation and analysis scheme of the response consider the surrounding rocks and the anomalous field of the local targets. It therefore can account for the geological data better than conventional transient field response analysis of local targets.展开更多
To improve the mechanical properties of the parts fabricated by Laser Direct Metal Shaping(LDMS),it is of great significance to understand the distribution regularities of transient temperature field during LDMS proce...To improve the mechanical properties of the parts fabricated by Laser Direct Metal Shaping(LDMS),it is of great significance to understand the distribution regularities of transient temperature field during LDMS process.Based on the“el- ement birth and death”technique of finite element method,a three-dimensional multi-track and multi-layer model for the transient temperature field analysis of LDMS is developed by ANSYS Parametric Design Language(APDL)for the first time.In the fab- ricated modal,X-direction parallel reciprocating scanning paths is introduced.Using the same process parameters,the simulation results show good agreement with the microstructure features of samples which fabricated by LDMS.展开更多
Combining separated SHPB test device of Ф50 mm with ZDKT-type 1 transient magnetic resonance test system, long drop bar of 400 mm was used to impact coal specimens at four different speeds: 1.275, 3.287, 6.251, and ...Combining separated SHPB test device of Ф50 mm with ZDKT-type 1 transient magnetic resonance test system, long drop bar of 400 mm was used to impact coal specimens at four different speeds: 1.275, 3.287, 6.251, and 7.404 m/s. The change in waveform, the dynamic mechanical properties, and the generated effect of transient field during the coal deformation and fracture under the loads were discussed and analyzed. While magnetic signals during the coal fracture firstly needed EEMD, decomposition then had a FFT with Data Demon. The main results of the experiment are the following: the main frequency of magnetic signals was between 220 and 450 kHz and the instantaneous frequency during the damage of coal would have the instantaneous jump.展开更多
Magnetorheological(MR)materials are a class of smart material,whose the mechanical/rheological state can be controlled under a magnetic field.Magnetorheological materials are typically fluids,gels,or elastomers.In thi...Magnetorheological(MR)materials are a class of smart material,whose the mechanical/rheological state can be controlled under a magnetic field.Magnetorheological materials are typically fluids,gels,or elastomers.In this study,anisotropic and isotropic magneto-rheological elastomer(MRE)samples were fabricated using a silicone rubber matrix with carbonyl iron particles as filler particles.The magnetic field-dependent inductance properties of these samples were studied using inductors specially designed for the analysis.The effect of the filler particle content,fabrication conditions,and inductance properties were characterized using a self-built system in both constant and transient magnetic fields.These factors show a significant effect on the inductance properties of the MRE inductor under an applied magnetic field.The anisotropic MRE inductor was more sensitive than the inductor based on an isotropic MRE.Owing to the presence of a constant magnetic field,the inductance value of the MRE inductor decreased with an increase in the external magnetic field.An attempt in elucidation of the mechanism is reported here.This study may enable the MRE to be widely used in practical applications such as monitoring magnetic field or detecting the filler particle content inside MR materials.展开更多
The electromagnetic field that generated by line current and sheet current at the surface of the earth can be expressed in analytical form. The line current created at the earth’s surface by an infinitely long line c...The electromagnetic field that generated by line current and sheet current at the surface of the earth can be expressed in analytical form. The line current created at the earth’s surface by an infinitely long line current is given by the inverse Fourier integrals over a horizontal wave number. The sheet current can be obtained by integrating the line current expansions using a Neumann and Struve functions;these functions have known mathematical properties, including the series expansions. The series expansions are exact with neglecting the displacement currents. Assuming a uniform earth and that there is no propagation, the three nonzero field components can be expressed in terms of the Neumann and Struve functions. The integrals of line current expansions are calculated by using the numerical methods. The results represented graphically and illustrated by figures. Results can be used to evaluate numerical solutions of more complicated modeling algorithms.展开更多
The instantaneous variations of the hydraulic characteristics take place in centrifugal pumps during their start-up,shutdown and other variable speed operations.In this paper,the variable speed method was proposed to ...The instantaneous variations of the hydraulic characteristics take place in centrifugal pumps during their start-up,shutdown and other variable speed operations.In this paper,the variable speed method was proposed to simulate the transient internal flow field and the external performance of the pump during starting and stopping periods.The terms of accelerations due to variable speeds in the flow governing equations were analyzed in a multiple reference of frame(MRF).A transient CFD simulation was performed for a typical centrifugal pump by using ANSYS-CFX with the standard k-εturbulence model.The entire simulation process was composed of four stages:start-up,normal run,shutdown and post-shutdown.The function of rotating speed with regard to time was set by CEL language directly into the impeller domain in the pre-processor of the software to conduct variable speed simulation.The variations of the flow field in the centrifugal pump were obtained from the transient simulation.The changing laws of flow rate,head and other performance parameters over time were also analyzed and summarized.展开更多
The thermal conditions like the temperature distribution and the heat fluxes during metal cutting have a major influence on the machinability, the tool lifetime, the metallurgical structure and thus the functionality ...The thermal conditions like the temperature distribution and the heat fluxes during metal cutting have a major influence on the machinability, the tool lifetime, the metallurgical structure and thus the functionality of the work piece. This in particular applies for manufacturing processes like milling, drilling and turning for high-value turbomachinery components like impellers, combustion engines and compressors of the aerospace and automotive industry as well as energy generation, which play a major role in modern societies. However, numerous analytical and experimental efforts have been conducted in order to understand the thermal conditions in metal cutting, yet many questions still prevail. Most models are based on a stationary point of view and do not include time dependent effects like in intensity and distribution varying heat sources, varying engagement conditions and progressive tool wear. In order to cover such transient physics an analytical approach based on Green's functions for the solution of the partial differential equations of unsteady heat conduction in solids is used to model entire transient temperature fields. The validation of the model is carried out in orthogonal cutting experiments not only punctually but also for entire temperature fields. For these experiments an integrated measurement of prevailing cutting force and temperature fields in the tool and the chip by means of high-speed thermography were applied. The thermal images were analyzed with regard to thermodynamic energy balancing in order to derive the heat partition between tool, chips and workpiece. The thus calculated heat flow into the tool was subsequently used in order to analytically model the transient volumetric temperature fields in the tool. The described methodology enables the modeling of the transient thermal state in the cutting zone and particular in the tool, which is directly linked to phenomena like tool wear and workpiece surface modifications.展开更多
In this paper, we investigate the temperature and drain bias dependency of single event transient (SET) in 25-nm fin field-effect-transistor (FinFET) technology in a temperature range of 0-135 ℃ and supply voltag...In this paper, we investigate the temperature and drain bias dependency of single event transient (SET) in 25-nm fin field-effect-transistor (FinFET) technology in a temperature range of 0-135 ℃ and supply voltage range of 0.4 V- 1.6 V. Technology computer-aided design (TCAD) three-dimensional simulation results show that the drain current pulse duration increases from 0.6 ns to 3.4 ns when the temperature increases from 0 to 135 ℃. The charge collected increases from 45.5 ℃ to 436.9 fC and the voltage pulse width decreases from 0.54 ns to 0.18 ns when supply voltage increases from 0.4 V to 1.6 V. Furthermore, simulation results and the mechanism of temperature and bias dependency are discussed.展开更多
Miniaturization of electronic package leads to high heat density and heat accumulation in electronics device, resulting in short life time and premature failure of the device. Junction temperature and thermal resistan...Miniaturization of electronic package leads to high heat density and heat accumulation in electronics device, resulting in short life time and premature failure of the device. Junction temperature and thermal resistance are the critical parameters that determine the thermal management and reliability in electronics cooling. Metal oxide field effect transistor(MOSFET)is an important semiconductor device for light emitting diode-integrated circuit(LED IC) driver application, and thermal management in MOSFET is a major challenge. In this study, investigations on thermal performance of MOSFET are performed for evaluating the junction temperature and thermal resistance. Suitable modifications in FR4 substrates are proposed by introducing thermal vias and copper layer coating to improve the thermal performance of MOSFET. Experiments are conducted using thermal transient tester(T3ster) at 2.0 A input current and ambient temperature varying from25℃ to 75℃. The thermal parameters are measured for three proposed designs: FR4 with circular thermal vias, FR4 with single strip of copper layer and embedded vias, and FR4 with I-shaped copper layer, and compared with that of plain FR4 substrate. From the experimental results, FR4I-shaped shows promising results by 33.71% reduction in junction temperature and 54.19% reduction in thermal resistance. For elevated temperature, the relative increases in junction temperature and thermal resistance are lower for FR4I-shaped than those for other substrates considered. The introduction of thermal vias and copper layer plays a significant role in thermal performance.展开更多
文摘The analysis of the impulse voltage on the internal electric field of the cable joint plays a key role in studying the breakdown of the joint. Based on the finite element method, a three-dimensional electromagnetic field simulation model of the cable joint is established in this paper. Simulation results show that the voltage at the head of the cable joint reaches about twice the impulse voltage. The increase of the conductivity of semi-conductive material also leads to the increase of electric field intensity. Then, several points and curves at different positions are selected for further analysis in this paper. Among them, the electric field distortion at the edge of the high voltage shield is the most serious and the electric field in the air gap is the least.
基金supported by the Young Scientists Fund of the National Natural Science Foundation of China(No.41304082)the Young Scientists Fund of the Natural Science Foundation of Hebei Province(No.D2014403011)the Geological survey project of China Geological Survey(No.12120114090201)
文摘We conducted a study on the numerical calculation and response analysis of a transient electromagnetic field generated by a ground source in geological media. One solution method, the traditional discrete image method, involves complex operation, and its digital filtering algorithm requires a large number of calculations. To solve these problems, we proposed an improved discrete image method, where the following are realized: the real number of the electromagnetic field solution based on the Gaver-Stehfest algorithm for approximate inversion, the exponential approximation of the objective kernel function using the Prony method, the transient electromagnetic field according to discrete image theory, and closed-form solution of the approximate coefficients. To verify the method, we tentatively calculated the transient electromagnetic field in a homogeneous model and compared it with the results obtained from the Hankel transform digital filtering method. The results show that the method has considerable accuracy and good applicability. We then used this method to calculate the transient electromagnetic field generated by a ground magnetic dipole source in a typical geoelectric model and analyzed the horizontal component response of the induced magnetic field obtained from the "ground excitation-stratum measurement method. We reached the conclusion that the horizontal component response of a transient field is related to the geoelectric structure, observation time, spatial location, and others. The horizontal component response of the induced magnetic field reflects the eddy current field distribution and its vertical gradient variation. During the detection of abnormal objects, positions with a zero or comparatively large offset were selected for the drill- hole measurements or a comparatively long observation delay was adopted to reduce the influence of the ambient field on the survey results. The discrete image method and forward calculation results in this paper can be used as references for relevant research.
基金Project(2012zzts019)supported by the Fundamental Research Funds for the Central Universities,ChinaProject(201306370121)supported by State Scholarship Fund of ChinaProject(51248006)supported by the National Natural Science Foundation,China
文摘This work presented the development and validation of an analytical method to predict the transient temperature field in the asphalt pavement.The governing equation for heat transfer was based on heat conduction radiation and convection.An innovative time-dependent function was proposed to predict the pavement surface temperature with solar radiation and air temperature using dimensional analysis in order to simplify the complex heat exchange on the pavement surface.The parameters for the time-dependent pavement surface temperature function were obtained through the regression analysis of field measurement data.Assuming that the initial pavement temperature distribution was linear and the influence of the base course materials on the temperature of the upper asphalt layers was negligible,a close-form analytical solution of the temperature in asphalt layers was derived using Green's function.Finally,two numerical examples were presented to validate the model solutions with field temperature measurements.Analysis results show that the solution accuracy is in agreement with field data and the relative errors at a shallower depth are greater than those at a deeper one.Although the model is not sensitive to dramatic changes in climatic factors near the pavement surface,it is applicable for predicting pavement temperature field in cloudless days.
文摘The on-orhit transient temperature of reflector laminate film was analyzed by using finite element method (FEM). Numerical simulation was used by FEM software ANSYS. Results reveal that the temperature levels of the laminate composite membrane alternate greatly in the orbital period, which is about±80℃. This range exceeds the material ' s operating temperature level. So it is necessary to put effective thermal control into effect to the laminate composite membrane. There is temperature gradient in the thickness direction of the laminate composite membrane; there is a light change in Kevlar/Epoxy layer. The temperature of the laminate composite membrane is obviously lower than the seam' s temperature. Results provide reference to the thermal control of the inflatable reflector with high precision requirement.
基金Sponsored by the National Natural Science Foundation of China(Grant No.51676055 and 51536001)
文摘Based on the analysis of factors affecting transient temperature field of aircraft fuel tank and coupled heat transfer mechanism, a mathematical model of transient coupled heat transfer, including the dynamic- change of fuel quality, the internal heat transfer, the external aerodynamic convection and the radiation heat transfer, is established. Taking the aerodynamic convection and radiation heat transfer outside the tank as the third kinds of thermal boundary conditions for the thermal analysis of the fuel tank, calculation of internal and external coupling heat of fuel tank is decoupled. Ther^nal network method combined with hierarchical dynamic- grid is used to deal with the fuel consumption, and carry on the heat transfer analysis of the fuel tank. The numerical method for the transient temperature field of aircraft fuel tank is established. Through the simulation calculation, the transient temperature distribution of the fuel tank under different flight conditions is obtained, and the influence of the fuel mass and the external thermal environment on the temperature field is analyzed.
文摘To decrease thermal stress during laser metal deposition shaping(LMDS)process,it is of great importance to learn the transient thermal stress distribution regularities.Based on the“element life and death”technique of finite element analy- sis(FEA),a three-dimensional multi-track and multi-layer numerical simulation model for LMDS is developed with ANSYS parametric design language(APDL)for the first time,in which long-edge parallel reciprocating scanning paths is introduced. Through the model,detailed simulations of thermal stress during whole metal cladding process are conducted,the generation and distribution regularities of thermal stress are also discussed in detail.Using the same process parameters,the simulation results show good agreement with the features of samples which fabricated by LMDS.
基金Supported by the National Natural Science Foundation of China under Grant Nos 51137004,61427806 and 51577184the Equipment Development Project of Chinese Academy of Sciences under Grant No YZ201507
文摘A new method of 3D transient eddy current field calculation is proposed. The Maxwell equations with time component elimination (METCE) are derived under the assumption of magnetic quasi static approximation, especially for the sample of low conductivity. Based on METCE, we deduce a more efficient reconstruction algorithm of a 3D transient eddy current field. The computational burden is greatly reduced through the new algorithm, and the computational efficiency is improved. This new algorithm decompounds the space-time variables into two individual variables. The idea is to solve the spatial vector component firstly, and then multiply it by the corresponded time component. The iterative methods based on METCE are introduced to recover the distribution of conductivity in magneto-acoustic tomography. The reconstructed images of conductivity are consistent with the original distribution, which validate the new method.
基金Project supported by the National Natural Science Foundation of China (Nos. 10372035 and10902043)the Key Laboratory of Diagnosis of Fault in Engineering Structures of Guangdong Province of China
文摘One of the primary reasons leading to bulging and cracking in a coke drum is the severe temperature gradient due to cyclic temperature variation. Based on the twodimensional heat conduction theory, an analytical solution of the transient temperature field in the coke drum is obtained, which is different from the known FEM results. The length of the coke drum is considered finite. The dynamic boundary conditions caused by fluid uninterrupted rising in oiling and watering stages are simulated with the iteration method. Numerical results show that the present theoretical model can accurately describe basic features of the transient temperature field in the coke drum. Effects of the geometry of the coke drum and the rising velocity of quench water on the axial temperature gradient are also discussed.
基金Science and Technology Project of State Grid Corporation of China(Project No.5226SX18000F)Science and Technology Project of State Grid Shaanxi Electric Power Company(Project No.5226KY18002M).
文摘In gas insulation switch(GIS)substation,secondary devices such as linemonitoring devices are placed in the switching field,and these electronic devices are vulnerable to transient electromagnetic interference caused by switching operation.In order to facilitate the measurement and research of electromagnetic disturbance data under different working conditions,a simulation test device is developed in this paper,which can be used to simulate electromagnetic disturbance of GIS substation sensor and secondary device port under switch operation.A four-channel parallel gas switch was designed,and the main characteristic parameters of electromagnetic disturbance generated by the simulation device were measured by using high-frequency pulse power supply as the excitation source.The comparison between the measured waveform and the measured disturbance characteristic parameters of GIS substation shows that it is in good agreement with the measured waveform characteristics,conforms to the basic characteristics of damped oscillation wave,and can be used in the secondary equipment port disturbance voltage coupling characteristics,protection measures evaluation and assessment method research.
文摘Our experiment shows that the dust grains, suspended on the edge of the sheath of a radio-frequency discharge, undergo a contraction when switching a vertical magnetic field on, and an expansion when switching the magnetic field off. We call this kind of magnetic field "transient magnetic field". A primary analysis is proposed for the phenomenon.
基金supported by the Young Scientists Fund of the National Natural Science Foundation of China(No.41304082)the China Postdoctoral Science Foundation(No.2016M590731)+2 种基金the Young Scientists Fund of the Natural Science Foundation of Hebei Province(No.D2014403011)the Program for Young Excellent Talents of Higher Education Institutions of Hebei Province(No.BJ2016046)the Geological survey project of China Geological Survey(No.1212011121197)
文摘We calculate the multicomponent responses of surface-hole transient electromagnetic method. The methods and models are unsuitable as geoelectric models of conductive surrounding rocks because they are based on regular local targets. We also propose a calculation and analysis scheme based on numerical simulations of the subsurface transient electromagnetic fields. In the modeling of the electromagnetic fields, the forward modeling simulations are performed by using the finite-difference time-domain method and the discrete image method, which combines the Gaver–Stehfest inverse Laplace transform with the Prony method to solve the initial electromagnetic fields. The precision in the iterative computations is ensured by using the transmission boundary conditions. For the response analysis, we customize geoelectric models consisting of near-borehole targets and conductive wall rocks and implement forward modeling simulations. The observed electric fields are converted into induced electromotive force responses using multicomponent observation devices. By comparing the transient electric fields and multicomponent responses under different conditions, we suggest that the multicomponent-induced electromotive force responses are related to the horizontal and vertical gradient variations of the transient electric field at different times. The characteristics of the response are determined by the varying the subsurface transient electromagnetic fields, i.e., diffusion, attenuation and distortion, under different conditions as well as the electromagnetic fields at the observation positions. The calculation and analysis scheme of the response consider the surrounding rocks and the anomalous field of the local targets. It therefore can account for the geological data better than conventional transient field response analysis of local targets.
文摘To improve the mechanical properties of the parts fabricated by Laser Direct Metal Shaping(LDMS),it is of great significance to understand the distribution regularities of transient temperature field during LDMS process.Based on the“el- ement birth and death”technique of finite element method,a three-dimensional multi-track and multi-layer model for the transient temperature field analysis of LDMS is developed by ANSYS Parametric Design Language(APDL)for the first time.In the fab- ricated modal,X-direction parallel reciprocating scanning paths is introduced.Using the same process parameters,the simulation results show good agreement with the microstructure features of samples which fabricated by LDMS.
文摘Combining separated SHPB test device of Ф50 mm with ZDKT-type 1 transient magnetic resonance test system, long drop bar of 400 mm was used to impact coal specimens at four different speeds: 1.275, 3.287, 6.251, and 7.404 m/s. The change in waveform, the dynamic mechanical properties, and the generated effect of transient field during the coal deformation and fracture under the loads were discussed and analyzed. While magnetic signals during the coal fracture firstly needed EEMD, decomposition then had a FFT with Data Demon. The main results of the experiment are the following: the main frequency of magnetic signals was between 220 and 450 kHz and the instantaneous frequency during the damage of coal would have the instantaneous jump.
基金Project(cstc2019jcyj-msxm X0005)supported by General Program of Chongqing Natural Science Foundation,ChinaProject(51905062)supported by the National Natural Science Foundation of China。
文摘Magnetorheological(MR)materials are a class of smart material,whose the mechanical/rheological state can be controlled under a magnetic field.Magnetorheological materials are typically fluids,gels,or elastomers.In this study,anisotropic and isotropic magneto-rheological elastomer(MRE)samples were fabricated using a silicone rubber matrix with carbonyl iron particles as filler particles.The magnetic field-dependent inductance properties of these samples were studied using inductors specially designed for the analysis.The effect of the filler particle content,fabrication conditions,and inductance properties were characterized using a self-built system in both constant and transient magnetic fields.These factors show a significant effect on the inductance properties of the MRE inductor under an applied magnetic field.The anisotropic MRE inductor was more sensitive than the inductor based on an isotropic MRE.Owing to the presence of a constant magnetic field,the inductance value of the MRE inductor decreased with an increase in the external magnetic field.An attempt in elucidation of the mechanism is reported here.This study may enable the MRE to be widely used in practical applications such as monitoring magnetic field or detecting the filler particle content inside MR materials.
文摘The electromagnetic field that generated by line current and sheet current at the surface of the earth can be expressed in analytical form. The line current created at the earth’s surface by an infinitely long line current is given by the inverse Fourier integrals over a horizontal wave number. The sheet current can be obtained by integrating the line current expansions using a Neumann and Struve functions;these functions have known mathematical properties, including the series expansions. The series expansions are exact with neglecting the displacement currents. Assuming a uniform earth and that there is no propagation, the three nonzero field components can be expressed in terms of the Neumann and Struve functions. The integrals of line current expansions are calculated by using the numerical methods. The results represented graphically and illustrated by figures. Results can be used to evaluate numerical solutions of more complicated modeling algorithms.
文摘The instantaneous variations of the hydraulic characteristics take place in centrifugal pumps during their start-up,shutdown and other variable speed operations.In this paper,the variable speed method was proposed to simulate the transient internal flow field and the external performance of the pump during starting and stopping periods.The terms of accelerations due to variable speeds in the flow governing equations were analyzed in a multiple reference of frame(MRF).A transient CFD simulation was performed for a typical centrifugal pump by using ANSYS-CFX with the standard k-εturbulence model.The entire simulation process was composed of four stages:start-up,normal run,shutdown and post-shutdown.The function of rotating speed with regard to time was set by CEL language directly into the impeller domain in the pre-processor of the software to conduct variable speed simulation.The variations of the flow field in the centrifugal pump were obtained from the transient simulation.The changing laws of flow rate,head and other performance parameters over time were also analyzed and summarized.
文摘The thermal conditions like the temperature distribution and the heat fluxes during metal cutting have a major influence on the machinability, the tool lifetime, the metallurgical structure and thus the functionality of the work piece. This in particular applies for manufacturing processes like milling, drilling and turning for high-value turbomachinery components like impellers, combustion engines and compressors of the aerospace and automotive industry as well as energy generation, which play a major role in modern societies. However, numerous analytical and experimental efforts have been conducted in order to understand the thermal conditions in metal cutting, yet many questions still prevail. Most models are based on a stationary point of view and do not include time dependent effects like in intensity and distribution varying heat sources, varying engagement conditions and progressive tool wear. In order to cover such transient physics an analytical approach based on Green's functions for the solution of the partial differential equations of unsteady heat conduction in solids is used to model entire transient temperature fields. The validation of the model is carried out in orthogonal cutting experiments not only punctually but also for entire temperature fields. For these experiments an integrated measurement of prevailing cutting force and temperature fields in the tool and the chip by means of high-speed thermography were applied. The thermal images were analyzed with regard to thermodynamic energy balancing in order to derive the heat partition between tool, chips and workpiece. The thus calculated heat flow into the tool was subsequently used in order to analytically model the transient volumetric temperature fields in the tool. The described methodology enables the modeling of the transient thermal state in the cutting zone and particular in the tool, which is directly linked to phenomena like tool wear and workpiece surface modifications.
基金Project supported by the State Key Program of the National Natural Science of China (Grant No. 60836004)the National Natural Science Foundation of China (Grant Nos. 61076025 and 60906014)
文摘In this paper, we investigate the temperature and drain bias dependency of single event transient (SET) in 25-nm fin field-effect-transistor (FinFET) technology in a temperature range of 0-135 ℃ and supply voltage range of 0.4 V- 1.6 V. Technology computer-aided design (TCAD) three-dimensional simulation results show that the drain current pulse duration increases from 0.6 ns to 3.4 ns when the temperature increases from 0 to 135 ℃. The charge collected increases from 45.5 ℃ to 436.9 fC and the voltage pulse width decreases from 0.54 ns to 0.18 ns when supply voltage increases from 0.4 V to 1.6 V. Furthermore, simulation results and the mechanism of temperature and bias dependency are discussed.
基金Project supported by the Collaborative Research in Engineering,Science&Technology(Grant No.P28C2-13)
文摘Miniaturization of electronic package leads to high heat density and heat accumulation in electronics device, resulting in short life time and premature failure of the device. Junction temperature and thermal resistance are the critical parameters that determine the thermal management and reliability in electronics cooling. Metal oxide field effect transistor(MOSFET)is an important semiconductor device for light emitting diode-integrated circuit(LED IC) driver application, and thermal management in MOSFET is a major challenge. In this study, investigations on thermal performance of MOSFET are performed for evaluating the junction temperature and thermal resistance. Suitable modifications in FR4 substrates are proposed by introducing thermal vias and copper layer coating to improve the thermal performance of MOSFET. Experiments are conducted using thermal transient tester(T3ster) at 2.0 A input current and ambient temperature varying from25℃ to 75℃. The thermal parameters are measured for three proposed designs: FR4 with circular thermal vias, FR4 with single strip of copper layer and embedded vias, and FR4 with I-shaped copper layer, and compared with that of plain FR4 substrate. From the experimental results, FR4I-shaped shows promising results by 33.71% reduction in junction temperature and 54.19% reduction in thermal resistance. For elevated temperature, the relative increases in junction temperature and thermal resistance are lower for FR4I-shaped than those for other substrates considered. The introduction of thermal vias and copper layer plays a significant role in thermal performance.