期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Transmission Line Modelling of Geomagnetic Induction in the Ocean/Earth Conductivity Structure
1
作者 David H. Boteler Shibaji Chakraborty +2 位作者 Xueling Shi Michael D. Hartinger Xuan Wang 《International Journal of Geosciences》 2023年第8期767-791,共25页
During geomagnetic disturbances, electric fields induced in the Earth and in power systems, pipelines and submarine cables can interfere with the operation of these systems. Calculations for submarine cables are compl... During geomagnetic disturbances, electric fields induced in the Earth and in power systems, pipelines and submarine cables can interfere with the operation of these systems. Calculations for submarine cables are complicated by the need to consider not just the induction directly into the cable but also the earth potentials produced at the coast at each end of the cable. To determine the coast potentials, we present a new model of the ocean and earth conductivity structure that spans the whole length of a cable from one coast to another. Calculations are based on the generalised thin sheet approach introduced by Ranganayaki and Madden but converted to a transmission line model that can be solved using standard circuit theory techniques. It is shown how the transmission line model can be used to calculate the earth potential profile from one side of an ocean or sea to the other. Example calculations are presented for a shallow sea, a shallow ocean, and a deep ocean that are simplified approximations to the North Sea, Tasman Sea and Pacific Ocean and show that the peak potentials occur at the coast. An examination is also made of how the width of a shallow sea and the width of the continental shelf affect these coast potentials. The modelling technique and example results provide a guide for more detailed modelling of geomagnetic induction along the routes of specific submarine cables. 展开更多
关键词 Geomagnetic Induction Generalised Thin Sheet transmission line modelling Coast Potentials Submarine Cables
下载PDF
Transmission line model of carbon nanotubes:through the Boltzmann transport equation 被引量:1
2
作者 方舟 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2011年第6期7-11,共5页
A transmission line(TL)model of a carbon nanotube(CNT)is analyzed through the Boltzmann transport equation(BTE).With the help of a numerical solution of the BTE,we study the kinetic inductance(L_K), quantum ca... A transmission line(TL)model of a carbon nanotube(CNT)is analyzed through the Boltzmann transport equation(BTE).With the help of a numerical solution of the BTE,we study the kinetic inductance(L_K), quantum capacitance(C_Q)and resistivity(R_S)of a CNT under a high frequency electric field.Values of L_K and C_Q obtained from BTE accord with the theoretical values,and the TL model is verified by transport theory for the first time.Moreover,our results show that the AC resistivity of CNTs deviates from DC,increasing along with shorter electric field wave length.This shows that changes in R_S in the high frequency condition must be considered in the TL model. 展开更多
关键词 carbon nanotube transmission line model transport equation
原文传递
Assessing high-energy x-ray and proton irradiation effects on electrical properties of P-GaN and N-GaN thin films
3
作者 钟傲雪 王磊 +6 位作者 唐蕴 杨永涛 王进进 朱慧平 吴真平 唐为华 李博 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第7期443-447,共5页
The effects of ionizing and displacement irradiation of high-energy x-ray and 2-MeV proton on GaN thin films were investigated and compared in this study.The electrical properties of both P-GaN and N-GaN,separated fro... The effects of ionizing and displacement irradiation of high-energy x-ray and 2-MeV proton on GaN thin films were investigated and compared in this study.The electrical properties of both P-GaN and N-GaN,separated from power devices,were gauged for fundamental analysis.It was found that the electrical properties of P-GaN were improved as a consequence of the disruption of the Mg-H bond induced by high-dose x-ray irradiation,as indicated by the Hall and circular transmission line model.Specifically,under a 100-Mrad(Si)x-ray dose,the specific contact resistance pc of P-GaN decreased by 30%,and the hole carrier concentration increased significantly.Additionally,the atom displacement damage effect of a 2-MeV proton of 1×10^(13)p/cm^(2)led to a significant degradation of the electrical properties of P-GaN,while those of N-GaN remained unchanged.P-GaN was found to be more sensitive to irradiation than N-GaN thin film.The effectiveness of x-ray irradiation in enhancing the electrical properties of P-GaN thin films was demonstrated in this study. 展开更多
关键词 x-ray radiation proton radiation GAN circular transmission line model(CTLM)
下载PDF
Advanced high-pressure plasma diagnostics with hairpin resonator probe surrounded by film and sheath 被引量:1
4
作者 徐金洲 石建军 +3 位作者 张菁 张琪 中村圭二 菅井秀郎 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第7期387-393,共7页
The hairpin probe using microwave resonance in plasma is applicable to high pressure 1.33 ×10^3-1.01×10^5 Pa)) as developed recently. In this work, an analytic model of the hairpin resonator probe surround... The hairpin probe using microwave resonance in plasma is applicable to high pressure 1.33 ×10^3-1.01×10^5 Pa)) as developed recently. In this work, an analytic model of the hairpin resonator probe surrounded by a thin dielectric layer and a sheath layer is proposed. The correction factor due to these surroundings is analytically found and confirmed by electromagnetic field finite difference time domain simulation, thus enabling the accurate measurement of electron density in a high-pressure non-equilibrium uniform discharge. 展开更多
关键词 hairpin resonator probe simulation high-pressure plasma transmission line model
下载PDF
Analysis of the harmful effects to buried oil pipeline from power line short-circuit fault 被引量:1
5
作者 LU Ying-hua MO Fan 《The Journal of China Universities of Posts and Telecommunications》 EI CSCD 2012年第5期124-128,共5页
Based on the transmission line theory of the buried metallic structures, the concerned harmful effects to the buried oil and natural gas pipelines caused by the power line short-circuit fault are further discussed. A ... Based on the transmission line theory of the buried metallic structures, the concerned harmful effects to the buried oil and natural gas pipelines caused by the power line short-circuit fault are further discussed. A closed-form expression of the induced voltage caused by the short-circuit fault of the ultra-high voltage power (UHVAC) transmission line is given. The transmission line model of the buried pipeline is set up and a set of formulas for calculating induced voltage on the pipeline and the parameters of the buried pipeline in actual environment condition are given. At last, the characteristic of the harm^hl effects on the buried pipeline from the power line short-circuit fault are discussed. 展开更多
关键词 ultra-high voltage (UHV) power line short-circuit fault oil pipeline transmission line model of the buried metallic structures
原文传递
A Similarity Comparison Based Pilot Protection Scheme for VSC-HVDC Grids Considering Fault Current Limiting Strategy
6
作者 Keao Chen Jinghan He +3 位作者 Meng Li Yong Tang Ming Nie Chenguang Liang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第4期1305-1315,共11页
In the voltage source converter based high-voltage direct current(VSC-HVDC)grids,fast and reliable protections are the key technologies.The traditional protection schemes are easily affected by fault resistance,line d... In the voltage source converter based high-voltage direct current(VSC-HVDC)grids,fast and reliable protections are the key technologies.The traditional protection schemes are easily affected by fault resistance,line distributed capacitance,etc.Meanwhile,the influence of fault current limiting strategy(FCLS)has not been fully considered.In this paper,the fault characteristics under FCLS and the feasibility of traditional travelling wave protections are analyzed.To improve the reliability and sensibility,a similarity comparison based pilot protection scheme is proposed,which focuses on the relationship between the fault characteristics and the state of the protected transmission line,with the establishment of a precise frequencydependent transmission line model.The criteria based on the similarity comparison calculated by cross-wavelet can identify the fault effectively.Meanwhile,the protection scheme can also endure the influence of error synchronization.Finally,the protection performance is verified in the PSCAD/EMTDC under different fault conditions. 展开更多
关键词 Voltage source converter based high voltage direct current(VSC-HVDC) fault current limiting strategy(FCLS) fault characteristic pilot protection similarity comparison frequency-dependent transmission line model
原文传递
Impact of Motor Stator Winding Faults on Motor Differential-mode Impedance and Mode Transformation
7
作者 Fei Fan Zhenyu Zhao +5 位作者 Huamin Jie Quqin Sun Pengfei Tu Zhou Shu Wensong Wang Kye Yak See 《Chinese Journal of Electrical Engineering》 CSCD 2022年第3期12-21,共10页
Motor impedance and mode transformation have significant effects on the electromagnetic interference(EMI)generated in motor drive systems.Stator winding faults commonly cause motor failure;however,in their early stage... Motor impedance and mode transformation have significant effects on the electromagnetic interference(EMI)generated in motor drive systems.Stator winding faults commonly cause motor failure;however,in their early stages,they may not affect the short-term operation of the motor.To date,EMI noise under the influence of premature stator winding faults has not been adequately studied,particularly the differential-mode(DM)noise due to the common-mode(CM)-to-DM transformation.This study investigates and quantifies the influence of stator winding faults on the motor DM impedance and mode transformation.First,the transmission line model of an induction motor is described based on the scattering(S)parameter measurements of each phase of the motor.It offers the flexibility to emulate different types of stator winding faults at specific locations and various severities,such that the impacts of the faults on the motor DM impedance can be easily estimated.Second,a test setup is proposed to quantify the CM-to-DM transformation due to the stator winding faults.The findings of this study reveal that even the early stages of stator winding faults can result in significant changes in the DM noise. 展开更多
关键词 Differential-mode(DM)impedance DM noise mode transformation motor stator winding faults transmission line model
原文传递
Optimization of ohmic contact for InP-based transferred electronic devices
8
作者 武德起 丁武昌 +3 位作者 杨姗姗 贾锐 金智 刘新宇 《Journal of Semiconductors》 EI CAS CSCD 2014年第3期158-162,共5页
The effect of the annealing time and annealing temperature on Ni/Ge/Au electrode contacts deposited on the n-type InP contact layer has been studied using a circular transmission line model. The minimum specific conta... The effect of the annealing time and annealing temperature on Ni/Ge/Au electrode contacts deposited on the n-type InP contact layer has been studied using a circular transmission line model. The minimum specific contact resistance of 3.210 7 cm2was achieved on the low-doped n-type InP contact layer with a 40 s anneal at 425 ℃. In order to improve the ohmic contact and reduce the difficulty in the fabrication of the high doped InP epi-layer, the doping concentration in the InP contact layer was chosen to be 51018cm 3in the fabrication of transferred electronic devices. Excellent differential negative resistance properties were obtained by an electron beam evaporating the Ni/Ge/Au/Ge/Ni/Au composite electrode on an InP epi-layer with a 60 s anneal at 380 ℃. 展开更多
关键词 circular transmission line model specific contact resistance InP transferred electronic devices differential negative resistance
原文传递
上一页 1 下一页 到第