The paper deals with the tests on the first 500 kV compact transmission line. The transmission line stretches from Fangshan Substation to Changping Substation nearby Beijing with a length of 83 km. In order to investi...The paper deals with the tests on the first 500 kV compact transmission line. The transmission line stretches from Fangshan Substation to Changping Substation nearby Beijing with a length of 83 km. In order to investigate the characteristics of the transmission line, many tests were performed on the line before and after its operation. The results indicate that all electrical parameters are perfectly identical to the design.展开更多
The sparse distribution characteristics of renewable energy resources can lead to there being tens of kilometers of transmission lines between a grid-connected inverter and the actual grid.Accurate analysis of the sta...The sparse distribution characteristics of renewable energy resources can lead to there being tens of kilometers of transmission lines between a grid-connected inverter and the actual grid.Accurate analysis of the stability of such gridconnected inverter systems currently involves using a complex hyperbolic function to shaped model of the transmission line circuit.This has proved to be problematic,so,drawing upon the distribution parameter characteristics of transmission lines,this paper looks at how to use impedance-based stability criteria to assess the stability of multi-paralleled grid-connected inverters.First,the topology of multi-paralleled inverters connected to the grid via transmission lines is established,using each transmission line terminal as a grid connection point.Each grid-connected system is taken to be equivalent to a small-signal circuit model of the“current source-grid”.Euler’s formula and the Nyquist stability criterion are combined to assess the stability of the associated grid-connected current transfer functions and evaluate the stability of the grid-connected current.Finally,a simulation analysis circuit is constructed to verify whether power line intervention will cause stability problems in the grid-connected system.Overall,it is found that long-distance transmission lines are more likely to cause unstable output of the grid-connected current.It is also found that the number of grid-connected inverters,the short-circuit ratio(SCR),the distorted grid and the inverter parameters can all have a significant impact on the stability of the grid-connected current.展开更多
文摘The paper deals with the tests on the first 500 kV compact transmission line. The transmission line stretches from Fangshan Substation to Changping Substation nearby Beijing with a length of 83 km. In order to investigate the characteristics of the transmission line, many tests were performed on the line before and after its operation. The results indicate that all electrical parameters are perfectly identical to the design.
文摘The sparse distribution characteristics of renewable energy resources can lead to there being tens of kilometers of transmission lines between a grid-connected inverter and the actual grid.Accurate analysis of the stability of such gridconnected inverter systems currently involves using a complex hyperbolic function to shaped model of the transmission line circuit.This has proved to be problematic,so,drawing upon the distribution parameter characteristics of transmission lines,this paper looks at how to use impedance-based stability criteria to assess the stability of multi-paralleled grid-connected inverters.First,the topology of multi-paralleled inverters connected to the grid via transmission lines is established,using each transmission line terminal as a grid connection point.Each grid-connected system is taken to be equivalent to a small-signal circuit model of the“current source-grid”.Euler’s formula and the Nyquist stability criterion are combined to assess the stability of the associated grid-connected current transfer functions and evaluate the stability of the grid-connected current.Finally,a simulation analysis circuit is constructed to verify whether power line intervention will cause stability problems in the grid-connected system.Overall,it is found that long-distance transmission lines are more likely to cause unstable output of the grid-connected current.It is also found that the number of grid-connected inverters,the short-circuit ratio(SCR),the distorted grid and the inverter parameters can all have a significant impact on the stability of the grid-connected current.