期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Combined hybrid energy storage system and transmission grid model for peak shaving based on time series operation simulation
1
作者 Mingkui Wei Yiyu Wen +3 位作者 Qiu Meng Shunwei Zheng Yuyang Luo Kai Liao 《Global Energy Interconnection》 EI CAS CSCD 2023年第2期154-165,共12页
This study proposes a combined hybrid energy storage system(HESS) and transmission grid(TG) model, and a corresponding time series operation simulation(TSOS) model is established to relieve the peak-shaving pressure o... This study proposes a combined hybrid energy storage system(HESS) and transmission grid(TG) model, and a corresponding time series operation simulation(TSOS) model is established to relieve the peak-shaving pressure of power systems under the integration of renewable energy. First, a linear model for the optimal operation of the HESS is established, which considers the different power-efficiency characteristics of the pumped storage system, electrochemical storage system, and a new type of liquid compressed air energy storage. Second, a TSOS simulation model for peak shaving is built to maximize the power entering the grid from the wind farms and HESS. Based on the proposed model, this study considers the transmission capacity of a TG. By adding the power-flow constraints of the TG, a TSOS-based HESS and TG combination model for peak shaving is established. Finally, the improved IEEE-39 and IEEE-118 bus systems were considered as examples to verify the effectiveness and feasibility of the proposed model. 展开更多
关键词 Peak shaving Hybrid energy storage system Combined energy storage and transmission grid model Time series operation simulation
下载PDF
Effects of the Reactive Power Injection on the Grid—The Rise of the Volt/var Interaction Chain
2
作者 Albana Ilo 《Smart Grid and Renewable Energy》 2016年第7期217-232,共17页
The major challenge to increase the decentralized generation share in distribution grids is the maintenance of the voltage within the limits. The inductive power injection is widely used as a remedial measure. The mai... The major challenge to increase the decentralized generation share in distribution grids is the maintenance of the voltage within the limits. The inductive power injection is widely used as a remedial measure. The main aim of this paper is to study the effect of the reactive power injection (by what-ever means) on radial grid structures and their impact on the voltage of the higher voltage-level grids. Various studies have shown that, in addition to the major local effect on the voltage at the injection point, the injection of the reactive power on a feeder has a global effect, which cannot be neglected. The reactive power flow and the voltage on the higher voltage level grid are significantly affected. In addition, a random effect is introduced by the DGs which are connected through inverters (using wind or PVs). Although their operation is in accordance with the grid code, a volatile reactive power flow circulates on the grid. Finally, this study proposes the implementation of the “Volt/var secondary control” interaction chain in order to increase the distributed generation share at every distribution voltage level, be it medium or low voltage, and at the same time to guarantee a stable operation of the power grid. Features of Volt/var secondary control loops ensure a resilient behavior of the whole chain. 展开更多
关键词 Distributed Generation LINK-Architecture Smart grid transmission grid Volt/var Control Volt/var Interdependencies
下载PDF
Distributed continuation power flow method for integrated transmission and active distribution network 被引量:7
3
作者 Jinquan ZHAO Xiaolong FAN +1 位作者 Changnian LIN Wenhui WEI 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2015年第4期573-582,共10页
As the integration of distributed generations(DGs)transforms the traditional distribution network into the active distribution network,voltage stability assessments(VSA)of transmission grid and distribution grid are n... As the integration of distributed generations(DGs)transforms the traditional distribution network into the active distribution network,voltage stability assessments(VSA)of transmission grid and distribution grid are not suitable to be studied separately.This paper presents a distributed continuation power flow method for VSA of global transmission and distribution grid.Two different parameterization schemes are adopted to guarantee the coherence of load growth in transmission and distribution grids.In the correction step,the boundary bus voltage,load parameter and equivalent power are communicated between the transmission and distribution control centers to realize the distributed computation of load margin.The optimal multiplier technique is used to improve the convergence of the proposed method.The three-phase unbalanced characteristic of distribution networks and the reactive capability limits of DGs are considered.Simulation results on two integrated transmission and distribution test systems show that the proposed method is effective. 展开更多
关键词 Integrated transmission and distribution grid Distributed computation Voltage stability Continuation power flow Three-phase distribution network Distribution generation
原文传递