期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Experimental studies on impedance based fault location for long transmission lines 被引量:7
1
作者 Saeed Roostaee Mini S.Thomas Shabana Mehfuz 《Protection and Control of Modern Power Systems》 2017年第1期169-177,共9页
In long transmission lines,the charging current caused by the shunt capacitance decreases the accuracy in impedance based fault location.To improve the accuracy of fault location,this paper presents a novel scheme,whe... In long transmission lines,the charging current caused by the shunt capacitance decreases the accuracy in impedance based fault location.To improve the accuracy of fault location,this paper presents a novel scheme,where two Digital Fault Recorders(DFRs)are installed in a line.They can send the transient data of the faults to the both ends of a line.To estimate the distance of a fault,impedance based fault location methods are applied with transient fault data of both ends protection relays and both DFRs installed in a line.To evaluate the proposed scheme,a laboratory setup has been developed.In the lab,several faults have been simulated and associated voltages and currents are injected to a relay IED to compare experimental results. 展开更多
关键词 transmission line fault location Impedance based fault location
原文传递
Robust fault analysis in transmission lines using Synchrophasor measurements 被引量:3
2
作者 Rajaraman P. Sundaravaradan N.A. +2 位作者 Mallikarjuna B. Jaya Bharata Reddy M. Mohanta D.K. 《Protection and Control of Modern Power Systems》 2018年第1期108-120,共13页
As more electric utilities and transmission system operators move toward the smart grid concept,robust fault analysis has become increasingly complex.This paper proposes a methodology for the detection,classification,... As more electric utilities and transmission system operators move toward the smart grid concept,robust fault analysis has become increasingly complex.This paper proposes a methodology for the detection,classification,and localization of transmission line faults using Synchrophasor measurements.The technique involves the extraction of phasors from the instantaneous three-phase voltages and currents at each bus in the system which are then decomposed into their symmetrical components.These components are sent to the phasor data concentrator(PDC)for real-time fault analysis,which is completed within 2–3 cycles after fault inception.The advantages of this technique are its accuracy and speed,so that fault information may be appropriately communicated to facilitate system restoration.The proposed algorithm is independent of the transmission system topology and displays high accuracy in its results,even with varying parameters such as fault distance,fault inception angle and fault impedance.The proposed algorithm is validated using a three-bus system as well as the Western System Coordinating Council(WSCC)nine bus system.The proposed algorithm is shown to accurately detect the faulted line and classify the fault in all the test cases presented. 展开更多
关键词 transmission line faults fault analysis Phasor measurement units Symmetrical components
原文传递
Mechanisms governing the evolution of a long-lived northwest vortex that caused a series of disasters in Northwest China
3
作者 Shuang-Long Jin Bo Wang +4 位作者 Shuang-Lei Feng Xiao-Lin Liu Zong-Peng Song Ju Hu Zheng Li 《Atmospheric and Oceanic Science Letters》 CSCD 2022年第2期19-25,共7页
The northwest vortex(NWV)is a type of mesoscale vortex that appears with a relatively high frequency in Northwest China.To further the understanding of the NWV’s evolution,in this study,the moisture and circulation b... The northwest vortex(NWV)is a type of mesoscale vortex that appears with a relatively high frequency in Northwest China.To further the understanding of the NWV’s evolution,in this study,the moisture and circulation budgets of a long-lived NWV(~132 h)that appeared in early August 2019 were calculated.This vortex induced a series of torrential rainfall events in Northwest China and Mongolia,which caused severe transmission line faults and urban waterlogging.Synoptic analyses indicate that the NWV was generated in a favorable background environment characterized by notable upper-level divergence and strong mid-level warm advection.The moisture budget shows that the East China Sea and Bohai Sea acted as the main moisture sources for the NWV-associated precipitation,and the water vapor was transported into the rainfall regions mainly by easterly and southeasterly winds.The circulation budget indicates that,during the developing stage,convergence-related vertical stretching was a dominant factor for the NWV’s development;whereas,the vortex’s displacement from regions with stronger cyclonic vorticity to those with weaker cyclonic vorticity mainly decelerated its development.In the decaying stage,divergence-related vertical shrinking and the net export of cyclonic vorticity due to the eddy flow’s transport resulted in the NWV’s dissipation. 展开更多
关键词 Northwest vortex Torrential rainfall transmission line faults Moistrue budget Circulation budget
下载PDF