In order to study the dynamic response of high-voltage transmission lines under mechanical failure, a finite element model of a domestic 500-kV high-voltage transmission line system is established. The initial equilib...In order to study the dynamic response of high-voltage transmission lines under mechanical failure, a finite element model of a domestic 500-kV high-voltage transmission line system is established. The initial equilibrium condition of the coupling system model is verified by nonlinear static analysis. The transient dynamic analysis method is proposed to analyze the variation law of dynamic response under cable or insulator rupture, and the dynamic response of structural elements next to the broken span is calculated. The results show that upper crossarm cable rupture has no effect on cable tension at adjacent suspension points, but it has a significant influence on tension in the insulator and the tower component of the upper crossarm next to the broken span. The peak tension in the conductor of the upper crossarm at the suspension point exceeds the design value under insulator rupture. Insulator rupture has no effect on the tower component of the upper crossarm, but it has a significant influence on insulator tension of the upper crossarm. Insulator rupture should be taken into account in the design of overhead transmission lines. The research results can provide a theoretical basis for the design of transmission lines.展开更多
A semi-analytical method in time domain is presented for analysis of the transient response of nonuniform transmission lines. In this method, the telegraph equations in time domain is differenced in space domain first...A semi-analytical method in time domain is presented for analysis of the transient response of nonuniform transmission lines. In this method, the telegraph equations in time domain is differenced in space domain first, and is transformed into a set of first-order differential equations of voltage and current with respect to time. By integrating these differential equations with respect to time, and precise computation, the solution of these differential equations can be obtained. This method can solve the transient response of various kinds of transmission lines with arbitrary terminal networks. Particularly, it can analyze the nonuniform lines with initial conditions, for which there is no existing effective method to analyze the time response so far. The results obtained with this method are stable and accurate. Two examples are given to illustrate the application of this method.展开更多
An analytical solution to the transient dynamic response of a cylindrical lining subjected to an internal loading was presented and the dynamic interaction between the lining and surrounding soil was considered. The l...An analytical solution to the transient dynamic response of a cylindrical lining subjected to an internal loading was presented and the dynamic interaction between the lining and surrounding soil was considered. The lining structure and the soil were treated as a cylindrical elastic shell and an infinite elastic compressible medium, respectively. A two-dimensional axisymmetric wave equation was derived from the governing equation of displacement by introducing the potential functions. Shell equation of motion was established based on continuity conditions. The closed-form solution for dynamic response of the lining due to an impact loading was obtained in Laplace transforms and inverse transforms. Detailed parametric studies were also presented to illustrate the influences of the Poisson ratio of soil, the dynamic shear moduli of both soil and lining and the thickness of lining on dynamic response of the lining.展开更多
This article presents an extensive examination and modeling of Capacitor Coupled Substations (CCS), noting some of their inherent constraints. The underlying implementation of a CCS is to supply electricity directly f...This article presents an extensive examination and modeling of Capacitor Coupled Substations (CCS), noting some of their inherent constraints. The underlying implementation of a CCS is to supply electricity directly from high-voltage (HV) transmission lines to low-voltage (LV) consumers through coupling capacitors and is said to be cost-effective as compared to conventional distribution networks. However, the functionality of such substations is susceptible to various transient phenomena, including ferroresonance and overvoltage occurrences. To address these challenges, the study uses simulations to evaluate the effectiveness of conventional resistor-inductor-capacitor (RLC) filter in mitigating hazardous overvoltage resulting from transients. The proposed methodology entails using standard RLC filter to suppress transients and its associated overvoltage risks. Through a series of MATLAB/Simulink simulations, the research emphasizes the practical effectiveness of this technique. The study examines the impact of transients under varied operational scenarios, including no-load switching conditions, temporary short-circuits, and load on/off events. The primary aim of the article is to assess the viability of using an established technology to manage system instabilities upon the energization of a CCS under no-load circumstances or in case of a short-circuit fault occurring on the primary side of the CCS distribution transformer. The findings underscore the effectiveness of conventional RLC filters in suppressing transients induced by the CCS no-load switching.展开更多
The analysis of transient linear viscoelastic response of asphalt concrete (AC) is important for engineering applications. The traditional transient response of AC is analyzed in the time domain by performing compli...The analysis of transient linear viscoelastic response of asphalt concrete (AC) is important for engineering applications. The traditional transient response of AC is analyzed in the time domain by performing complicated convolution integral. The frequency domain approach allows one to determine the transient responses by performing simple multi- plication instead of the complicated convolution integral, and it does not require the time derivative of the input excitation, and thus, the approach could greatly reduce the analysis complexity. This study investigated the frequency domain approach in calculating the transient response by utilizing the discrete Fourier transform technique. The accuracy and effectiveness of the frequency domain approach were verified by comparing the analytical and calculated responses for the standard 3-parameter Maxwell model and by comparing the time and frequency domain solutions for AC. The effect of aliasing of the frequency domain approach can effectively reduce by selecting a small sampling interval for the time domain excitation function. A sampling interval is acceptable as long as the amplitude of the Fourier transformed excitation is close to 0 more than half of the sampling rate. The results show that the frequency domain approach provides a simple and accurate way to perform linear viscoelastic analysis of AC.展开更多
基金The National Natural Science Foundation of China (No.50578038)the Science and Technology Project of the State Grid Corporation of China(No.SGKJ[2007]116)
文摘In order to study the dynamic response of high-voltage transmission lines under mechanical failure, a finite element model of a domestic 500-kV high-voltage transmission line system is established. The initial equilibrium condition of the coupling system model is verified by nonlinear static analysis. The transient dynamic analysis method is proposed to analyze the variation law of dynamic response under cable or insulator rupture, and the dynamic response of structural elements next to the broken span is calculated. The results show that upper crossarm cable rupture has no effect on cable tension at adjacent suspension points, but it has a significant influence on tension in the insulator and the tower component of the upper crossarm next to the broken span. The peak tension in the conductor of the upper crossarm at the suspension point exceeds the design value under insulator rupture. Insulator rupture has no effect on the tower component of the upper crossarm, but it has a significant influence on insulator tension of the upper crossarm. Insulator rupture should be taken into account in the design of overhead transmission lines. The research results can provide a theoretical basis for the design of transmission lines.
文摘A semi-analytical method in time domain is presented for analysis of the transient response of nonuniform transmission lines. In this method, the telegraph equations in time domain is differenced in space domain first, and is transformed into a set of first-order differential equations of voltage and current with respect to time. By integrating these differential equations with respect to time, and precise computation, the solution of these differential equations can be obtained. This method can solve the transient response of various kinds of transmission lines with arbitrary terminal networks. Particularly, it can analyze the nonuniform lines with initial conditions, for which there is no existing effective method to analyze the time response so far. The results obtained with this method are stable and accurate. Two examples are given to illustrate the application of this method.
基金Project(51178342) supported by the National Natural Science Foundation of ChinaProject(20103718120005) supported by Specialized Research Fund for the Doctoral Program of Higher Education,China
文摘An analytical solution to the transient dynamic response of a cylindrical lining subjected to an internal loading was presented and the dynamic interaction between the lining and surrounding soil was considered. The lining structure and the soil were treated as a cylindrical elastic shell and an infinite elastic compressible medium, respectively. A two-dimensional axisymmetric wave equation was derived from the governing equation of displacement by introducing the potential functions. Shell equation of motion was established based on continuity conditions. The closed-form solution for dynamic response of the lining due to an impact loading was obtained in Laplace transforms and inverse transforms. Detailed parametric studies were also presented to illustrate the influences of the Poisson ratio of soil, the dynamic shear moduli of both soil and lining and the thickness of lining on dynamic response of the lining.
文摘This article presents an extensive examination and modeling of Capacitor Coupled Substations (CCS), noting some of their inherent constraints. The underlying implementation of a CCS is to supply electricity directly from high-voltage (HV) transmission lines to low-voltage (LV) consumers through coupling capacitors and is said to be cost-effective as compared to conventional distribution networks. However, the functionality of such substations is susceptible to various transient phenomena, including ferroresonance and overvoltage occurrences. To address these challenges, the study uses simulations to evaluate the effectiveness of conventional resistor-inductor-capacitor (RLC) filter in mitigating hazardous overvoltage resulting from transients. The proposed methodology entails using standard RLC filter to suppress transients and its associated overvoltage risks. Through a series of MATLAB/Simulink simulations, the research emphasizes the practical effectiveness of this technique. The study examines the impact of transients under varied operational scenarios, including no-load switching conditions, temporary short-circuits, and load on/off events. The primary aim of the article is to assess the viability of using an established technology to manage system instabilities upon the energization of a CCS under no-load circumstances or in case of a short-circuit fault occurring on the primary side of the CCS distribution transformer. The findings underscore the effectiveness of conventional RLC filters in suppressing transients induced by the CCS no-load switching.
基金sponsored by Inner Mongolia Transportation Research Project(NJ-2014-X)Shanxi Transportation Research Project(2015-1-22)National Natural Science Foundation of China(51208080)
文摘The analysis of transient linear viscoelastic response of asphalt concrete (AC) is important for engineering applications. The traditional transient response of AC is analyzed in the time domain by performing complicated convolution integral. The frequency domain approach allows one to determine the transient responses by performing simple multi- plication instead of the complicated convolution integral, and it does not require the time derivative of the input excitation, and thus, the approach could greatly reduce the analysis complexity. This study investigated the frequency domain approach in calculating the transient response by utilizing the discrete Fourier transform technique. The accuracy and effectiveness of the frequency domain approach were verified by comparing the analytical and calculated responses for the standard 3-parameter Maxwell model and by comparing the time and frequency domain solutions for AC. The effect of aliasing of the frequency domain approach can effectively reduce by selecting a small sampling interval for the time domain excitation function. A sampling interval is acceptable as long as the amplitude of the Fourier transformed excitation is close to 0 more than half of the sampling rate. The results show that the frequency domain approach provides a simple and accurate way to perform linear viscoelastic analysis of AC.