This study assessed the clinical application of transvaginal three-dimensional ultrasound (3D TVUS) in the diagnosis of congenital uterine malformation. A retrospective study was performed on 62 patients with congen...This study assessed the clinical application of transvaginal three-dimensional ultrasound (3D TVUS) in the diagnosis of congenital uterine malformation. A retrospective study was performed on 62 patients with congenital uterine malformation confirmed hysteroscopically and/or laparoscopically. The patients were subjected to transvaginal two-dimensional ultrasound (2D TVUS) and 3D TVUS. The accuracy rate was compared between the two methods. The accuracy rate of 3D TVUS was (98.38%, 61/62), higher than that of 2D TVUS (80.65%, 50/62). 3D TVUS coronal plane imaging could demon- strate the internal shape of the endometrial cavity and the external contour of the uterine fundus. It al- lowed accurate measurement on the coronary plane, and could three-dimensionally show the image of cervical tube, thereby providing information for the diagnosis of some complex uterine malformation. 3D TVUS imaging can obtain comprehensive information of the uterus malformation, and it is superior to 2D TVUS for the diagnosis of congenital uterine malformations, especially complex uterine anomaly.展开更多
BACKGROUND Endometrial lesions include endometrial cancer and inferior fibroids.Among them,endometrial cancer as a malignant tumor seriously endangers the life and health of patients.Ultrasonography is an important me...BACKGROUND Endometrial lesions include endometrial cancer and inferior fibroids.Among them,endometrial cancer as a malignant tumor seriously endangers the life and health of patients.Ultrasonography is an important means of diagnosing female reproductive system diseases,and it is of critical value for the early diagnosis of endometrial cancer.However,different ultrasound inspection programs have achieved different results.It is of great significance to choose a suitable inspection program.AIM To explore the diagnostic efficacy of different ultrasonic examination methods in clinical endometrial lesions.METHODS The 140 patients with endometrial lesions who were treated in our hospital from April 2018 to October 2019 were used as the research subjects.All patients underwent transvaginal color ultrasound and transabdominal color ultrasound.We compared the diagnostic coincidence and image display effects of the two different examination methods,and the endometrial thickness,blood flow,uterine effusion and resistance index of different diseases were observed by transvaginal color ultrasound.RESULTS The diagnostic coincidence rate of all types of diseases of transvaginal color ultrasound was significantly higher than that of transabdominal color ultrasound(P=0.001,0.005,0.001 and 0.001).In addition,the excellent and good rate of image display of transvaginal color ultrasound was higher than that of transabdominal color ultrasound(P=0.001).There were significant differences in endometrial thickness in patients with different types of endometrial lesions through the transvaginal color examination(P=0.001).The incidence rate of uterine effusion in patients with endometrial carcinoma was significantly higher than that in patients with other types of endometrial lesions(P=0.001),and the rate of the blood flow was the highest(P=0.001).The comparison of blood flow resistance index indicated that the blood flow resistance index in endometrial cancer patients was the lowest,which shows that the difference was statistically significant(P=0.001).CONCLUSION The overall diagnostic efficacy of transvaginal color ultrasound in the clinical diagnosis of endometrial lesions is better than that of transabdominal color ultrasound,which held higher diagnostic coincidence rate and image display effect.There were significant differences in the thickness of the endometrium and the blood flow in different types of lesions.展开更多
文摘This study assessed the clinical application of transvaginal three-dimensional ultrasound (3D TVUS) in the diagnosis of congenital uterine malformation. A retrospective study was performed on 62 patients with congenital uterine malformation confirmed hysteroscopically and/or laparoscopically. The patients were subjected to transvaginal two-dimensional ultrasound (2D TVUS) and 3D TVUS. The accuracy rate was compared between the two methods. The accuracy rate of 3D TVUS was (98.38%, 61/62), higher than that of 2D TVUS (80.65%, 50/62). 3D TVUS coronal plane imaging could demon- strate the internal shape of the endometrial cavity and the external contour of the uterine fundus. It al- lowed accurate measurement on the coronary plane, and could three-dimensionally show the image of cervical tube, thereby providing information for the diagnosis of some complex uterine malformation. 3D TVUS imaging can obtain comprehensive information of the uterus malformation, and it is superior to 2D TVUS for the diagnosis of congenital uterine malformations, especially complex uterine anomaly.
文摘BACKGROUND Endometrial lesions include endometrial cancer and inferior fibroids.Among them,endometrial cancer as a malignant tumor seriously endangers the life and health of patients.Ultrasonography is an important means of diagnosing female reproductive system diseases,and it is of critical value for the early diagnosis of endometrial cancer.However,different ultrasound inspection programs have achieved different results.It is of great significance to choose a suitable inspection program.AIM To explore the diagnostic efficacy of different ultrasonic examination methods in clinical endometrial lesions.METHODS The 140 patients with endometrial lesions who were treated in our hospital from April 2018 to October 2019 were used as the research subjects.All patients underwent transvaginal color ultrasound and transabdominal color ultrasound.We compared the diagnostic coincidence and image display effects of the two different examination methods,and the endometrial thickness,blood flow,uterine effusion and resistance index of different diseases were observed by transvaginal color ultrasound.RESULTS The diagnostic coincidence rate of all types of diseases of transvaginal color ultrasound was significantly higher than that of transabdominal color ultrasound(P=0.001,0.005,0.001 and 0.001).In addition,the excellent and good rate of image display of transvaginal color ultrasound was higher than that of transabdominal color ultrasound(P=0.001).There were significant differences in endometrial thickness in patients with different types of endometrial lesions through the transvaginal color examination(P=0.001).The incidence rate of uterine effusion in patients with endometrial carcinoma was significantly higher than that in patients with other types of endometrial lesions(P=0.001),and the rate of the blood flow was the highest(P=0.001).The comparison of blood flow resistance index indicated that the blood flow resistance index in endometrial cancer patients was the lowest,which shows that the difference was statistically significant(P=0.001).CONCLUSION The overall diagnostic efficacy of transvaginal color ultrasound in the clinical diagnosis of endometrial lesions is better than that of transabdominal color ultrasound,which held higher diagnostic coincidence rate and image display effect.There were significant differences in the thickness of the endometrium and the blood flow in different types of lesions.