In order to ascertain the key factors affecting the lifetime of the triple grids in the LIPS-300 ion thruster,the thermal deformation,upstream ion density and component lifetime of the grids are simulated with finite ...In order to ascertain the key factors affecting the lifetime of the triple grids in the LIPS-300 ion thruster,the thermal deformation,upstream ion density and component lifetime of the grids are simulated with finite element analysis,fluid simulation and charged-particle tracing simulation methods on the basis of a 1500 h short lifetime test.The key factor affecting the lifetime of the triple grids in the LIPS-300 ion thruster is obtained and analyzed through the test results.The results show that ion sputtering erosion of the grids in 5 kW operation mode is greater than in the case of 3 kW.In 5 kW mode,the decelerator grid shows the most serious corrosion,the accelerator grid shows moderate corrosion,and the screen grid shows the least amount of corrosion.With the serious corrosion of the grids in 5 kW operation mode,the intercept current of the acceleration and deceleration grids increases substantially.Meanwhile,the cold gap between the accelerator grid and the screen grid decreases from 1 mm to 0.7 mm,while the cold gap between the accelerator grid and the decelerator grid increases from 1 mm to 1.25 mm after 1500 h of thruster operation.At equilibrium temperature with 5 k W power,the finite element method(FEM)simulation results show that the hot gap between the screen grid and the accelerator grid reduces to 0.2 mm.Accordingly,the hot gap between the accelerator grid and the decelerator grid increases to 1.5 mm.According to the fluid method,the plasma density simulated in most regions of the discharge chamber is 1?×?10;-8?×?10;m;.The upstream plasma density of the screen grid is in the range 6?×?10;-6?×?10;m;and displays a parabolic characteristic.The charged particle tracing simulation method results show that the ion beam current without the thermal deformation of triple grids has optimal perveance status.The ion sputtering rates of the accelerator grid hole and the decelerator hole are 5.5?×?10;kg s;and 4.28?×?10;kg s;,respectively,while after the thermal deformation of the triple grids,the ion beam current has over-perveance status.The ion sputtering rates of the accelerator grid hole and the decelerator hole are 1.41?×?10;kg s;and 4.1?×?10;kg s;,respectively.The anode current is a key factor for the triple grid lifetime in situations where the structural strength of the grids does not change with temperature variation.The average sputtering rates of the accelerator grid and the decelerator grid,which were measured during the 1500 h lifetime test in5 k W operating conditions,are 2.2?×?10;kg s;and 7.3?×?10;kg s;,respectively.These results are in accordance with the simulation,and the error comes mainly from the calculation distribution of the upstream plasma density of the grids.展开更多
基金supported by the fund of National Key Laboratory of Science and Technology on Vacuum Technology and Physics (Grant No. 6142207030103)
文摘In order to ascertain the key factors affecting the lifetime of the triple grids in the LIPS-300 ion thruster,the thermal deformation,upstream ion density and component lifetime of the grids are simulated with finite element analysis,fluid simulation and charged-particle tracing simulation methods on the basis of a 1500 h short lifetime test.The key factor affecting the lifetime of the triple grids in the LIPS-300 ion thruster is obtained and analyzed through the test results.The results show that ion sputtering erosion of the grids in 5 kW operation mode is greater than in the case of 3 kW.In 5 kW mode,the decelerator grid shows the most serious corrosion,the accelerator grid shows moderate corrosion,and the screen grid shows the least amount of corrosion.With the serious corrosion of the grids in 5 kW operation mode,the intercept current of the acceleration and deceleration grids increases substantially.Meanwhile,the cold gap between the accelerator grid and the screen grid decreases from 1 mm to 0.7 mm,while the cold gap between the accelerator grid and the decelerator grid increases from 1 mm to 1.25 mm after 1500 h of thruster operation.At equilibrium temperature with 5 k W power,the finite element method(FEM)simulation results show that the hot gap between the screen grid and the accelerator grid reduces to 0.2 mm.Accordingly,the hot gap between the accelerator grid and the decelerator grid increases to 1.5 mm.According to the fluid method,the plasma density simulated in most regions of the discharge chamber is 1?×?10;-8?×?10;m;.The upstream plasma density of the screen grid is in the range 6?×?10;-6?×?10;m;and displays a parabolic characteristic.The charged particle tracing simulation method results show that the ion beam current without the thermal deformation of triple grids has optimal perveance status.The ion sputtering rates of the accelerator grid hole and the decelerator hole are 5.5?×?10;kg s;and 4.28?×?10;kg s;,respectively,while after the thermal deformation of the triple grids,the ion beam current has over-perveance status.The ion sputtering rates of the accelerator grid hole and the decelerator hole are 1.41?×?10;kg s;and 4.1?×?10;kg s;,respectively.The anode current is a key factor for the triple grid lifetime in situations where the structural strength of the grids does not change with temperature variation.The average sputtering rates of the accelerator grid and the decelerator grid,which were measured during the 1500 h lifetime test in5 k W operating conditions,are 2.2?×?10;kg s;and 7.3?×?10;kg s;,respectively.These results are in accordance with the simulation,and the error comes mainly from the calculation distribution of the upstream plasma density of the grids.