期刊文献+
共找到19篇文章
< 1 >
每页显示 20 50 100
Heat Transfer and Resistance Characteristics of Conical Spiral Tube Bundle Based on Field Synergy Principle 被引量:9
1
作者 YAN Ke GE Peiqi +1 位作者 HU Ruirong MENG Haitao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2012年第2期370-376,共7页
Conical spiral tube bundle are universally used in heat transfer enhancement in heat exchangers.The heat transfer and resistance of the tube bundle are affected greatly by the conical structure,so the analysis of it i... Conical spiral tube bundle are universally used in heat transfer enhancement in heat exchangers.The heat transfer and resistance of the tube bundle are affected greatly by the conical structure,so the analysis of it is necessary.In order to a further evaluation,the heat transfer and resistance characteristics of conical spiral tube bundle are investigated with regression analysis based on numerical simulation data.The correlations of heat transfer and pressure drop of conical spiral tube bundle are proposed both in laminar and turbulent fluid flow.On the based of the field synergy principle,the synergy of four vectors,the velocity,the velocity gradient,the temperature gradient and the pressure gradient,are calculated and discussed via the user defined function(UDF) program.The synergy angles β and θ,which respectively denote the performance of heat transfer enhancement and pressure drop of the conical spiral tube bundle,are analyzed.Finally,the comprehensive performance of the conical spiral tube is evaluated by the synergy angle γ and all of the three synergy angles of conical spiral tube bundle are compared to both bare tube and thin cylinder-interpolated tube.The analysis of the synergy angles shows that the heat transfer enhancement and pressure drop of conical spiral tube bundle are smaller than that of the thin cylinder-interpolated tube,while the comprehensive performance of conical spiral tube bundle is greater.The analysis of the heat transfer and pressure drop of conical spiral tube is valuable and instructional on the design and optimum of conical spiral tube bundle heat exchangers. 展开更多
关键词 conical spiral tube bundle field synergy principle regression analysis
下载PDF
Experimental Study on Cross-Flow Induced Vibrations in Heat Exchanger Tube Bundle 被引量:3
2
作者 KHUSHNOOD Shahab NIZAM Luqman Ahmad 《China Ocean Engineering》 SCIE EI CSCD 2017年第1期91-97,共7页
Vibration in heat exchangers is one of the main problems that the industry has faced over last few decades. Vibration phenomenon in heat exchangers is of major concern for designers and process engineers since it can ... Vibration in heat exchangers is one of the main problems that the industry has faced over last few decades. Vibration phenomenon in heat exchangers is of major concern for designers and process engineers since it can lead to the tube damage, tube leakage, baffle damage, tube collision damage, fatigue, creep etc. In the present study, vibration response is analyzed on single tube located in the centre of the tube bundle having parallel triangular arrangement (60-) with P/D ratio of 1.44. The experiment is performed for two different flow conditions. This kind of experiment has not been reported in the literature. Under the first condition, the tube vibration response is analyzed when there is no internal flow in the tube and under the second condition, the response is analyzed when the internal tube flow is maintained at a constant value of 0.1 rn/s. The free stream shell side velocity ranges from 0.8 rn/s to 1.3 m/s, the reduced gap velocity varies from 1,80 to 2.66 and the Reynolds number varies from 44500 to 66000. It is observed that the internal tube flow results in larger vibration amplitudes for the tube than that without internal tube flow. It is also established that over the current range of shell side flow velocity, the turbulence is the dominant excitation mechanism for producing vibration in the tube since the amplitude varies directly with the increase in the shell side velocity. Damping has no significant effect on the vibration behavior of the tube for the current velocity range. 展开更多
关键词 CROSS-FLOW tube bundle parallel Iriangular internal tube flow DAMPING
下载PDF
Experimental and Numerical Investigation on Erosion Corrosion of the Air Cooler Tube Bundle in a Residue Hydrotreating Unit 被引量:3
3
作者 Jin Haozhe Yu Chenyang +4 位作者 Gu Youjie Qian Guangwei Liu Xiaofei Ou Guofu Jia Yongna 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2022年第4期151-162,共12页
Corrosion leakage occurred in the 14th tube bundle in the first row of a residual oil hydrotreating air cooler after operating for two years.The failure location was 0.5 m from the outlet header box.In this paper,the ... Corrosion leakage occurred in the 14th tube bundle in the first row of a residual oil hydrotreating air cooler after operating for two years.The failure location was 0.5 m from the outlet header box.In this paper,the erosion corrosion of the air cooler tube bundle was investigated by experimental and numerical methods.Visual inspection,scanning electron microscopy(SEM),and X-ray diffraction(XRD)experiments were performed,and the failure morphology and material composition confirmed that the damage was caused by erosion corrosion.The shear stress transport k–ωturbulence model(SST-k–ω)was then used to investigate the flow and erosion corrosion characteristics,combined with mass transfer,corrosion rate,and ionization equilibrium models.The numerical simulation results revealed that the water phase volume fraction increased with flow and heat transfer in the fluid,which increased the mass flow rate and concentration of hydrogen sulfide.The mass transfer coefficient and corrosion rate were proposed as important parameters to characterize erosion corrosion.Moreover,the local concentration of wall shear stress was found to increase the risk of erosion corrosion.The predicted high-risk area was consistent with the actual failure area,which verified that this failure incident was attributable to erosion corrosion by the water phase. 展开更多
关键词 erosion corrosion air cooler tube bundle(ACTB) RESIDUE THINNING hydrogen sulfide
下载PDF
A comprehensive comparison on vibration and heat transfer of two elastic heat transfer tube bundles 被引量:7
4
作者 闫柯 葛培琪 翟强 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第1期377-385,共9页
Elastic heat transfer tube bundles are widely used in the field of flow-induced vibration heat transfer enhancement. Two types of mainly used tube bundles, the planar elastic tube bundle and the conical spiral tube bu... Elastic heat transfer tube bundles are widely used in the field of flow-induced vibration heat transfer enhancement. Two types of mainly used tube bundles, the planar elastic tube bundle and the conical spiral tube bundle were comprehensively compared in the condition of the same shell side diameter. The natural mode characteristics, the effect of fluid-structure interaction, the stress distribution, the comprehensive heat transfer performance and the secondary fluid flow of the two elastic tube bundles were all concluded and compared. The results show that the natural frequency and the critical velocity of vibration buckling of the planar elastic tube bundle are larger than those of the conical spiral tube bundle, while the stress distribution and the comprehensive heat transfer performance of the conical spiral tube bundle are relatively better. 展开更多
关键词 planar elastic tube bundle conical spiral tube bundle mode characteristics heat transfer performance
下载PDF
Heat transfer characteristics of air cross-flow for in-line arrangement of spirally corrugated tube and smooth tube bundles 被引量:1
5
作者 陆国栋 周强泰 +2 位作者 田茂诚 程林 俞小莉 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第7期670-675,共6页
An experimental study on heat transfer and resistance coefficients of linearly arranged smooth and spirally corrugated tube bundles in cross-flow was performed. The heat transfer and resistance coefficients are presen... An experimental study on heat transfer and resistance coefficients of linearly arranged smooth and spirally corrugated tube bundles in cross-flow was performed. The heat transfer and resistance coefficients are presented in this paper with transverse and longitudinal tube-pitch and tube geometries taken into account. The experiment's results can provide technical guidelines for application to horizontal air preheater with arranged in-line spirally corrugated tube bundles, especially to the air preheater for CFBCBs (Circulating Fluidized Bed Combustion Boilers). 展开更多
关键词 CFB Air preheater Spirally corrugated tube Linearly arranged tube bundles CROSS-FLOW
下载PDF
Heat transfer model of two-phase flow across tube bundle in submerged combustion vaporizer 被引量:1
6
作者 Jiajun Song Dongyan Han +2 位作者 Qinqin Xu Dan Zhou Jianzhong Yin 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2019年第3期613-619,共7页
In order to optimize the design of the submerged combustion vaporizer(SCV), an experimental apparatus was set up to investigate the heat transfer character outside the tube bundle in SCV. Several experiments were cond... In order to optimize the design of the submerged combustion vaporizer(SCV), an experimental apparatus was set up to investigate the heat transfer character outside the tube bundle in SCV. Several experiments were conducted using water and CO_2 as the heat transfer media in the tubes, respectively. The results indicated that hot air flux, the initial liquid level height and the tube pitch ratio had great influence on the heat transfer coefficient outside the tube bundle(ho). Finally, the air flux associated factor β and height associated factor γ were introduced to propose a new hocorrelation. After verified by experiments using cold water, high pressure CO_2 and liquid N_2 as heat transfer media, respectively, it was found that the biggest deviation between the predicted and the experimental values was less than 25%. 展开更多
关键词 Submerged combustion vaporizer Fluid sweeping tube bundle Two-phase flow Heat transfer coefficient Modeling
下载PDF
Experimental Study of Condensation Heat Transfer on Tube Bundles in Large Power Plant Condensers 被引量:1
7
作者 Koichi Inoue Issaku Fujita +2 位作者 Kotaro Machii Satoshi Hiraoka Manabu Ishihara 《Journal of Energy and Power Engineering》 2014年第5期920-928,共9页
In order to clarify the effect of condensate inundation on steam condensation in a large tube bundle, condensation heat transfer and the condensate flow pattern in the tube bundle have been experimentally investigated... In order to clarify the effect of condensate inundation on steam condensation in a large tube bundle, condensation heat transfer and the condensate flow pattern in the tube bundle have been experimentally investigated. Test tube bundle consists of 36 cooling tubes, 12 condensate supply tubes and 24 un-cooled dummy tubes. Cooling test tubes are made of copper and have an outer diameter of 19.1 mm and condensing length of 150 mm, Steam flows horizontally through the test tube bundle at gap velocities 15-27 m/s at pressures of 8.8 kPa. In this study, experimental data about condensate flow pattern and condensation heat transfer in a tube bundle were collected for the optimization of tube arrangement in large power plant condensers. 展开更多
关键词 CONDENSATION INUNDATION CONDENSER tube bundle tube arrangement power station.
下载PDF
Vibration Response and Stress Analysis of Planar Elastic Tube Bundle Induced by Fluid Flow
8
作者 De-Rong Duan Pei-Qi Ge +1 位作者 Wen-Bo Bi Yan-Ying Dong 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2018年第2期89-96,共8页
Flow?induced vibration plays a positive role on heat transfer enhancement. Meanwhile, it is also a negative factor for fatigue strength. Satisfying the fatigue strength is the primary prerequisite for heat transfer en... Flow?induced vibration plays a positive role on heat transfer enhancement. Meanwhile, it is also a negative factor for fatigue strength. Satisfying the fatigue strength is the primary prerequisite for heat transfer enhancement. This paper numerically studied the flow?induced vibration of planar elastic tube bundle based on a two?way fluid–structure interaction(FSI) calculation. The numerical calculation involved the unsteady, three?dimensional incompressible governing equations solved with finite volume approach and the dynamic balance equation of planar elastic tube bundle solved with finite element method combined with dynamic mesh scheme. The numerical approach was verified by comparing with the published experimental results. Then the vibration trajectory, deformation and stress contour of planar elastic tube bundle were all studied. Results show that the combined movement of planar elastic tube bundle represents the agitation from inside to outside. The vibration of out?of?plane is the main vibration form with the typically sinusoidal behavior because the magnitude of displacement along the out?of?plane direction is the 100 times than the value of in?plane direction. The dangerous point locates in the innermost tube where the equivalent stress can be utilized to study the multiaxial fatigue of planar elastic tube bundle due to the alternating stress concentration. In the velocity range of 0.2-3 m/s, it is inferred that the vibration amplitude plays a role on the stress response and the stress amplitude is susceptible to the fluid velocity. This research paves a way for studying the fatigue strength of planar elastic tube bundle by flow?induced vibration. 展开更多
关键词 Flow?induced vibration Planar elastic tube bundle Vibration response Stress analysis
下载PDF
Experimental study of shell side flow-induced vibration of conical spiral tube bundle 被引量:12
9
作者 闫柯 葛培琪 洪军 《Journal of Hydrodynamics》 SCIE EI CSCD 2013年第5期695-701,共7页
Conical spiral tube bundles are widely used in enhancing the heat transfer via the flow-induced vibration in heat exchangers. The shell side flow-induced vibration of the conical spiral tube bundle is experimentally i... Conical spiral tube bundles are widely used in enhancing the heat transfer via the flow-induced vibration in heat exchangers. The shell side flow-induced vibration of the conical spiral tube bundle is experimentally investigated in this paper. The experi- ment table was built and the operational modes, the vibration parameters of the tube bundle were analyzed. The results show that, the operational mode frequencies of the conical spiral tube are decreased as the shell-side fluid flow velocity increases, especially for the first order frequency. Within the parameter range of this experiment, the real working frequency of the conical spiral tube is between the 1 st and the 2nd operational modes, and the free end vibration amplitude of the tube bundle increases greatly when the shell side fluid flow velocity exceeds a critical value. 展开更多
关键词 conical spiral tube bundle operational mode flow-induced vibration shell side fluid flow
原文传递
Numerical analysis of shell-side flow-induced vibration of elastic tube bundle in heat exchanger 被引量:5
10
作者 Jia-dong Ji Pei-qi Ge Wen-bo Bi 《Journal of Hydrodynamics》 SCIE EI CSCD 2018年第2期249-257,共9页
The responses of the flow-induced vibration of an elastic tube bundle subjected to the shell-side cross flow are investigated in this paper. The weak coupling method and the fluid solid interface are used to solve the... The responses of the flow-induced vibration of an elastic tube bundle subjected to the shell-side cross flow are investigated in this paper. The weak coupling method and the fluid solid interface are used to solve the fluid-structure interaction problem with consideration of the geometry and physical natures. The effects of the shell-side fluid flow velocity and the structural parameters on the flow-induced vibration are discussed. Numerical results demonstrate that the vibration frequency and amplitude at the monitor points increase with the increase of the shell-side water inlet velocity in all directions. The wall thickness and the external diameter of the elastic tube bundle have significant effects on the responses of the flow-induced vibration. The structural parameters affect the vibration frequency and amplitude, and the vibration equilibrium position in the water flow direction. The vibration frequency decreases with the increase of the tube external diameter. In addition, the vibration in the water flow direction has a lower equilibrium position when the elastic tube bundle has a larger wall thickness or smaller external diameter. 展开更多
关键词 Flow-induced vibration heat exchanger elastic tube bundle fluid-structure interaction shell-side fluid weak coupling method
原文传递
New experimental method for inundation effect of film condensation on horizontal tube bundle 被引量:3
11
作者 MA ZhiXian ZHANG JiLi SUN DeXing 《Science China(Technological Sciences)》 SCIE EI CAS 2012年第10期2856-2863,共8页
Theory of film condensation heat transfer(FCHT) for vapor condensed on horizontal tube bundle(HTB) is vital to many industry processes.Meanwhile,the inundation effect is the key to model the film condensation heat tra... Theory of film condensation heat transfer(FCHT) for vapor condensed on horizontal tube bundle(HTB) is vital to many industry processes.Meanwhile,the inundation effect is the key to model the film condensation heat transfer coefficient(CHTC) on HTB.This paper proposed a new experimental method,homologous method,to obtain the inundation effect precisely.Based on the requirements of the new test method,a new test facility was designed and established.Then,the superiority of homologous method for inundation effect was investigated based on experiment result and theoretic analysis.The results showed that the homogenous method can effectively control the experimental error of inundation effect,which is less than 50% of the error of CHTC,and less than 30% of the error of the inundation effect gained by routine method.The new test facility built for the homogenous method is excellent in obtaining the accurate inundation effect of film condensation on HTB.All the result is a foundation of the theoretical development of the FCHT on HTB. 展开更多
关键词 horizontal tube bundle film condensation inundation effect experimental method experimental error
原文传递
MATHEMATICAL ANALYSIS OF TRANSVERSE VIBRATION OF CONICAL SPIRAL TUBE BUNDLE WITH EXTERNAL FLUID FLOW 被引量:2
12
作者 YAN Ke GE Pei-qi SU Yan-cai BI Wen-bo 《Journal of Hydrodynamics》 SCIE EI CSCD 2010年第6期816-822,共7页
The conical spiral tube bundle is a new type of heat transfer elements used to enhance heat transfer through flow-induced vibration. The effect of the external fluid flow on the transverse vibration of the conical spi... The conical spiral tube bundle is a new type of heat transfer elements used to enhance heat transfer through flow-induced vibration. The effect of the external fluid flow on the transverse vibration of the conical spiral tube bundle is investigated with a mathematical method proposed in this article. Firstly, the natural vibration of the tube bundle is obtained by the hammering excitation method and the mode shapes of the transverse vibration are discussed. Then the effect of the external fluid flow on the transverse vibration of tube bundle is analyzed by a combination of experimental data, empirical correlations and FEM. The results show that in the frequency range from 0 Hz to 50 Hz, there exist six transverse vibrations. The external fluid flow has a significant effect on the frequency of the tube's transverse vibration, which are decreased by about 18% to 24% when the external fluid flow speed is 0.3 m/s. 展开更多
关键词 conical spiral tube bundle mathematical model vibration characteristic FEM
原文传递
Calculation of relative permeability in reservoir engineering using an interacting triangular tube bundle model 被引量:2
13
作者 Jinxun Wang Mingzhe Dong Jun Yao 《Particuology》 SCIE EI CAS CSCD 2012年第6期710-721,共12页
Analytical expressions of relative permeability are derived for an interacting cylindrical tube bundle model. Equations for determining relative permeability curves from both the interacting uniform and interacting se... Analytical expressions of relative permeability are derived for an interacting cylindrical tube bundle model. Equations for determining relative permeability curves from both the interacting uniform and interacting serial types of triangular tube bundle models are presented. Model parameters affecting the trend of relative permeability curves are discussed. Interacting triangular tube bundle models are used to history-match laboratory displacement experiments to determine the relative permeability curves of actual core samples. By adjusting model parameters to match the history ofoil production and pressure drop, the estimated relative permeability curves provide a connection between the macroscopic flow behavior and the pore-scale characteristics of core samples. 展开更多
关键词 Interacting tube bundle modelPorous mediaModelingRelative permeability Imbibition
原文传递
Particle Image Velocimetry Measurement of Flow Across Tube Bundle in Waste Heat Boiler 被引量:1
14
作者 Chen Bin Guo Liejin (Xi’an Jiaotong University, Xi’an 710049, China ) 《Journal of Thermal Science》 SCIE EI CAS CSCD 2000年第3期249-256,共8页
In the present paper the experimental investigations of flow across staggered tube bundles in waste heat boiler are conducted by mans of PIV (Particle Image Velocimetry) system. Flow visualization and velocity distrib... In the present paper the experimental investigations of flow across staggered tube bundles in waste heat boiler are conducted by mans of PIV (Particle Image Velocimetry) system. Flow visualization and velocity distribution of the wake between different cylinders are measured in detail. It is concluded that there are still Von Karman vortices in the wake and the phenomena of vortex shedding, pairing, merging are observed in the flow. The Von Karman vortices can’t fully developed because of the existence of the downstream cylinder There is interaction between main streams and vortices, and the development of the vortex is enhanced by this interaction. Meanwhile some statistical results are performed. The distribution of correlated variables of the velocity fluctuations u’ u’, u’ v’, v’ v’ and the space correlation coefficients are obtained. 展开更多
关键词 tube bundle flow across cylinder turbulent wake.
原文传递
Numerical Study of Fluid Flow over Bundle Tubes
15
作者 Majid Almas 《Journal of Electronics Cooling and Thermal Control》 2016年第3期109-119,共12页
In this paper, a bank of tubes containing a flowing fluid which is immersed in a cross flow second medium of fluid with different temperature has been studied numerically using computational fluid dynamics. Laminar st... In this paper, a bank of tubes containing a flowing fluid which is immersed in a cross flow second medium of fluid with different temperature has been studied numerically using computational fluid dynamics. Laminar steady flow with a low Reynolds number has been studied in this work. Inlet mass flow rate and the bulk temperature are known and numerical method has been implemented to study the convective heat transfer to investigate the temperature and flow fields. Effects of different inlet bulk temperatures and mass flow rates have been investigated on temperature and pressure variations. 展开更多
关键词 Heat Transfer bundle tube Mass Flow Rate Numerical Solution
下载PDF
Heat transfer simulation of annular elliptical fin-and-tube heat exchanger by transition SST model 被引量:2
16
作者 H NEMATI A R RAHIMZADEH WANG Chi-chuan 《Journal of Central South University》 SCIE EI CAS CSCD 2020年第8期2324-2337,共14页
In this study,thermo-fluid characteristics of elliptical annular finned tube heat exchanger were numerically studied in detail.Transition SST model was utilized to simulate turbulent flow.Effects of air velocities,hor... In this study,thermo-fluid characteristics of elliptical annular finned tube heat exchanger were numerically studied in detail.Transition SST model was utilized to simulate turbulent flow.Effects of air velocities,horizontal to vertical fin diameter ratios,and fin densities were examined in detail.The simulations indicate superior performance of elliptical fin layout.It was shown that pressure drop of annular elliptical fin can be only one half of that of a circular annular fin while containing comparable heat transfer performance.The vertical elliptical annular fin may even contain a higher heat transfer performance over circular fin.Correlations are proposed to estimate the Nu number and pressure drop based on the annular circular fin.The maximum deviations between the proposed correlations and simulations regarding pressure drop and heat transfer coefficient are 5.6%and 3.2%,respectively.For further elaboration of the superiority of the elliptical layout from the second law perspective,normalized entropy generation was also studied.In all cases,the entropy generation rate in circular fin was higher than that of an elliptical fin. 展开更多
关键词 annular fin elliptical fin entropy generation transition SST model tube bundle
下载PDF
Application of a novel detection approach based on non-dispersive infrared theory to the in-situ analysis on indicator gases from underground coal fire 被引量:8
17
作者 TIAN Fu-chao LIANG Yun-tao +2 位作者 ZHU Hong-qing CHEN Ming-yi WANG Jin-cheng 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第6期1840-1855,共16页
Coal mine fires,which can cause heavy casualties,environmental damages and a waste of coal resources,have become a worldwide problem.Aiming at overcoming the drawbacks,such as a low analysis efficiency,poor stability ... Coal mine fires,which can cause heavy casualties,environmental damages and a waste of coal resources,have become a worldwide problem.Aiming at overcoming the drawbacks,such as a low analysis efficiency,poor stability and large monitoring error,of the existing underground coal fire monitoring technology,a novel monitoring system based on non-dispersive infrared(NDIR)spectroscopy is developed.In this study,first,the measurement principle of NDIR sensor,the gas concentration calculation and its temperature compensation algorithms were expounded.Next,taking CO and CH_(4) as examples,the liner correlation coefficients of absorbance and the temperature correction factors of the two indicator gases were calculated,and then the errors of concentration measurement for CO,CO_(2),CH_(4) and C_(2)H_(4) were further analyzed.The results disclose that the designed NDIR sensors can satisfy the requirements of industrial standards for monitoring the indicator gases for coal fire hazards.For the established NDIR-based monitoring system,the NDIRbased spectrum analyzer and its auxiliary equipment boast intrinsically safe and explosion-proof performances and can achieve real-time and in-situ detection of indicator gases when installed close to the coal fire risk area underground.Furthermore,a field application of the NDIR-based monitoring system in a coal mine shows that the NDIR-based spectrum analyzer has a permissible difference from the chromatography in measuring the concentrations of various indicator gases.Besides,the advantages of high accuracy,quick analysis and excellent security of the NDIR-based monitoring system have promoted its application in many coal mines. 展开更多
关键词 indicator gas coal spontaneous combustion infrared spectrometry bundle tube monitoring intrinsically safe
下载PDF
Thermo-flow characteristics and air flow field leading of the air-cooled condenser cell in a power plant 被引量:8
18
作者 ZHANG WanXi YANG LiJun +1 位作者 DU XiaoZe YANG YongPing 《Science China(Technological Sciences)》 SCIE EI CAS 2011年第9期2475-2482,共8页
Special A-frame geometry of the air-cooled condenser cell and the complicated flow field at the exit of the axial flow fan bring on the air mal-distribution on the surface of the finned tube bundles and the deteriorat... Special A-frame geometry of the air-cooled condenser cell and the complicated flow field at the exit of the axial flow fan bring on the air mal-distribution on the surface of the finned tube bundles and the deteriorated thermo-flow performances of a condenser cell. It is of benefit to the design and operation optimization of the direct dry cooling system in a power plant to investigate the thermo-flow characteristics of the condenser cell and propose the flow leading measures of cooling air. On the basis of the representative configuration of the air-cooled condenser cell in a 600 MW direct dry cooling power plant, the computa- tional models of the air side fluid and heat flows are built, in which the actual fan blade geometric details are considered. Various flow field leading ways of cooling air are presented and the thermo-flow characteristics in the A-frame condenser cell and through the finned tube bundles are compared. Results show that the flow field leading measures can result in the increased volumetric flow rate and heat rejection, thus bringing on the improved performance of the condenser cell. The improvement of thermo-flow oerformances depends upon the geometric details of the flow guiding device. 展开更多
关键词 air-cooled condenser axial flow fan t'mned tube bundle flow and heat transfer characteristics flow field leading
原文传递
COMPLEX HEAT TRANSFER ENHANCEMENT BY FLUID INDUCED VIBRATION 被引量:8
19
作者 Cheng Lin, Qiu YanSchool of Energy Source and Power Engineering, Shandong University, Jinan 250061, China 《Journal of Hydrodynamics》 SCIE EI CSCD 2003年第1期84-89,共6页
A new method of heat transfer enhancement by fluid induced vibration was putforward, and its theoretical a-nalysis and experimental study were performed. Though people alwaystry to prophylaxis fluid induced vibration ... A new method of heat transfer enhancement by fluid induced vibration was putforward, and its theoretical a-nalysis and experimental study were performed. Though people alwaystry to prophylaxis fluid induced vibration for regarding it as an accident, the utilization space offluid induced vibration is still very large. The in-surface and out-surface vibrations which comefrom the fluid induce elastic tube bundles, can effectively increase the convective heat transfercoefficient, and also decrease the fouling resistance, then increase the heat transfer coefficientremarkably. 展开更多
关键词 elastic tube bundles fluid induced vibration fouling resistance convective heat transfer coefficient
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部