期刊文献+
共找到1,019篇文章
< 1 2 51 >
每页显示 20 50 100
A Review on Technologies for the Use of CO2 as a Working Fluid in Refrigeration and Power Cycles
1
作者 Orelien T. Boupda Hyacinthe D. Tessemo +3 位作者 Isidore B. Nkounda Fongang Francklin G. Nyami Frederic Lontsi Thomas Djiako 《Energy and Power Engineering》 2024年第6期217-256,共40页
The use of carbon dioxide as a working fluid has been the subject of extensive studies in recent years, particularly in the field of refrigeration where it is at the heart of research to replace CFC and HCFC. Its ther... The use of carbon dioxide as a working fluid has been the subject of extensive studies in recent years, particularly in the field of refrigeration where it is at the heart of research to replace CFC and HCFC. Its thermodynamic properties make it a fluid of choice in the efficient use of energy at low and medium temperatures in engine cycles. However, the performance of transcritical CO2 cycles weakens under high temperature and pressure conditions, especially in refrigeration systems;On the other hand, this disadvantage becomes rather interesting in engine cycles where CO2 can be used as an alternative to the organic working fluid in small and medium-sized electrical systems for low quality or waste heat sources. In order to improve the performance of systems operating with CO2 in the field of refrigeration and electricity production, research has made it possible to develop several concepts, of which this article deals with a review of the state of the art, followed by analyzes in-depth and critical of the various developments to the most recent modifications in these fields. Detailed discussions on the performance and technical characteristics of the different evolutions are also highlighted as well as the factors affecting the overall performance of the systems studied. Finally, perspectives on the future development of the use of CO2 in these different cycles are presented. 展开更多
关键词 refrigeration cycle Power cycle System Performance Transcritical CO2 cycles Working Fluid
下载PDF
Effect of an Internal Heat Exchanger on the Performances of a Double Evaporator Ejector Refrigeration Cycle
2
作者 Rachedi Khadraoui Latra Boumaraf Philippe Haberschill 《Fluid Dynamics & Materials Processing》 EI 2023年第5期1115-1128,共14页
A theoretical investigation is presented about a double evaporator ejector refrigeration cycle(DEERC).Special attention is paid to take into account the influence of the sub-cooling and superheating effects induced by... A theoretical investigation is presented about a double evaporator ejector refrigeration cycle(DEERC).Special attention is paid to take into account the influence of the sub-cooling and superheating effects induced by an internal heat exchanger(IHX).The ejector is introduced into the baseline cycle in order to mitigate the throttling process losses and increase the compressor suction pressure.Moreover,the IHX has the structure of a concentric counter-flow type heat exchanger and is intentionally used to ensure that the fluid at the compressor inlet is vapor.To assess accurately the influence of the IHX on the DEERC performance,a mathematical model is derived in the frame of the dominant one-dimensional theory for ejectors.The model also accounts for the friction effect in the ejector mixing section.The equations of this model are solved using an Engineering Equation Solver(EES)for different fluids.These are:R134a as baseline fluid and other environment friendly refrigerants used for comparison,namely,R1234yf,R1234ze,R600,R600a,R290,R717 and R1270.The simulation results show that the DEERC with an IHX can achieve COP(the coefficient of performance)improvements from 5.2 until 10%. 展开更多
关键词 refrigeration cycle double evaporator EJECTOR IHX performance improvement environment-friendlyrefrigerants
下载PDF
Performance analysis of ammonia-water absorption/compression combined refrigeration cycle 被引量:1
3
作者 鲍帅阳 杜垲 +2 位作者 蔡星辰 牛晓峰 武云龙 《Journal of Southeast University(English Edition)》 EI CAS 2014年第1期60-67,共8页
In view of different compressor adding ways in the ammonia-water absorption/compression combined refrigeration AWA /CCR cycle combining the Schulz state equation of the ammonia-water solution the theoretical analysis ... In view of different compressor adding ways in the ammonia-water absorption/compression combined refrigeration AWA /CCR cycle combining the Schulz state equation of the ammonia-water solution the theoretical analysis and calculations on two combination ways by adding the compressor in the high-pressure area and in the low-pressure area are conducted respectively.The effects of several factors including the evaporation temperature Te heat-source temperature Th as well as the cooling water temperature Tw on the equivalent heat consumption in compression qCW heat consumption in absorption qG and the system coefficient of performance COP are analyzed under the two combination configurations.The results show that the effect of the equivalent heat consumption in compression on the COP is less than that of the heat consumption in absorption.Besides the compressor set in the high-pressure area uses more energy than that in the low-pressure area. Moreover the compressor in the low-pressure area is superior to that in the high-pressure area with respect to the COP. Under the given intermediate pressure there is an optimum heat-source temperature corresponding to the maximum COP of the AWA/CCR cycle. 展开更多
关键词 AMMONIA-WATER ABSORPTION compression refrigeration combined refrigeration cycle coefficient of performance COP
下载PDF
Energy Efficient Predictive Control for Vapor Compression Refrigeration Cycle Systems 被引量:3
4
作者 Xiaohong Yin Shaoyuan Li 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2018年第5期953-960,共8页
Abstract--Vapor compression refrigeration cycle (VCC) system is a high dimensional coupling thermodynamic system for which the controller design is a great challenge. In this paper, a model predictive control based ... Abstract--Vapor compression refrigeration cycle (VCC) system is a high dimensional coupling thermodynamic system for which the controller design is a great challenge. In this paper, a model predictive control based energy efficient control strategy which aims at maximizing the system efficiency is proposed. Firstly, according to the mass and energy conservation law, an analysis on the nonlinear relationship between superheat and cooling load is carried out, which can produce the maximal effect on the system performance. Then a model predictive control (MPC) based controller is developed for tracking the calculated setting curve of superheat degree and pressure difference based on model identified from data which can be obtained from an experimental rig. The proposed control strategy maximizes the coefficient of performance (COP) which depends on operating conditions, in the meantime, it meets the changing demands of cooling capacity. The effectiveness of the control performance is validated on the experimental rig. Index Terms--Cooling load, model predictive control (MPC), superheat, vapor compression refrigeration cycle (VCC). 展开更多
关键词 Cooling load model predictive control(MPC) SUPERHEAT vapor compression refrigeration cycle(VCC)
下载PDF
Performance of an irreversible quantum refrigeration cycle
5
作者 何济洲 欧阳微频 伍歆 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第1期53-59,共7页
A new model of a quantum refrigeration cycle composed of two adiabatic and two isomagnetic field processes is established. The working substance in the cycle consists of many non-interacting spin-1/2 systems. The perf... A new model of a quantum refrigeration cycle composed of two adiabatic and two isomagnetic field processes is established. The working substance in the cycle consists of many non-interacting spin-1/2 systems. The performance of the cycle is investigated, based on the quantum master equation and semi-group approach. The general expressions of several important performance parameters, such as the coefficient of performance, cooling rate, and power input, are given. It is found that the coefficient of performance of this cycle is in the closest analogy to that of the classical Carnot cycle. Furthermore, at high temperatures the optimal relations of the cooling rate and the maximum cooling rate are analysed in detail. Some performance characteristic curves of the cycle are plotted, such as the cooling rate versus the maximum ratio between high and low "temperatures" of the working substances, the maximum cooling rate versus the ratio between high and low "magnetic fields" and the "temperature" ratio between high and low reservoirs. The obtained results are further generalized and discussed, so that they may be directly applied to describing the performance of the quantum refrigerator using spin-J systems as the working substance. Finally, the optimum characteristics of the quantum Carnot and Ericsson refrigeration cycles are derived by analogy. 展开更多
关键词 spin systems quantum refrigeration cycle performance parameters
下载PDF
Experiments on an Open-Loop Cycle Carbon Dioxide Refrigeration System
6
作者 徐雷 蒋彦龙 +1 位作者 郑小漪 蔡玉飞 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2015年第4期452-460,共9页
An open loop cycle carbon dioxide(CO2)refrigeration system is established,and the cooling performances of high-pressure CO2 under different storage conditions(25℃,30℃,and 35℃)are investigated.Moreover,the experimen... An open loop cycle carbon dioxide(CO2)refrigeration system is established,and the cooling performances of high-pressure CO2 under different storage conditions(25℃,30℃,and 35℃)are investigated.Moreover,the experimental mass flow rates of CO2 are compared with the theoretical values at different conditions and refrigeration capacities.The results indicate that the storage condition of CO2 has a significant impact on the refrigeration performance,and the mass flow rate of CO2 increases with the increasing storage temperature in a given refrigeration capacity. 展开更多
关键词 CO2 open loop cycle refrigeration system mass flow rate storage condition
下载PDF
Theoretical Study on CO_2 Transcritical Cycle Combined Ejector Cycle Refrigeration System
7
作者 卢苇 马一太 +1 位作者 李敏霞 查世彤 《Transactions of Tianjin University》 EI CAS 2003年第4期316-320,共5页
Chlorofluorocarbons(CFCs) or hydrochlorofluorocarbons(HCFCs) are as main refrigerants used in traditional refrigeration systems driven by electricity from burning fossil fuels, which is regarded as one of the major re... Chlorofluorocarbons(CFCs) or hydrochlorofluorocarbons(HCFCs) are as main refrigerants used in traditional refrigeration systems driven by electricity from burning fossil fuels, which is regarded as one of the major reasons for ozone depletion (man-made refrigerants emission) and global warming (CO 2 emission). So people pay more and more attention to natural refrigerants and energy saving technologies. An innovative system combining CO 2 transcritical cycle with ejector cycle is proposed in this paper. The CO 2 compression sub-cycle is powered by electricity with the characteristics of relatively high temperature in the gas cooler (defined as an intercooler by the proposed system). In order to recover the waste heat, an ejector sub-cycle operating with the natural refrigerants (NH 3, H 2O) is employed. The two sub-cycles are connected by an intercooler. This combined cycle joins the advantages of the two cycles together and eliminates the disadvantages. The influences of the evaporation temperature in CO 2 compression sub-cycle, the evaporation temperature in the ejector sub-cycle, the temperature in the intercooler and the condensation temperature in the proposed system performance are discussed theoretically in this study. In addition, some unique features of the system are presented. 展开更多
关键词 heat pump CO 2 transcritical cycle EJECTOR natural refrigerants
下载PDF
Second Law of Thermodynamics Analysis of Transcritical Carbon Dioxide Refrigeration Cycle
8
作者 杨俊兰 马一太 +1 位作者 管海清 李敏霞 《Transactions of Tianjin University》 EI CAS 2004年第3期179-183,共5页
In order to identify the locations of irreversible loss within the transcritical carbon dioxide refrigeration cycle with an expansion turbine, a method with respect to the second law of thermodynamics based on exergy ... In order to identify the locations of irreversible loss within the transcritical carbon dioxide refrigeration cycle with an expansion turbine, a method with respect to the second law of thermodynamics based on exergy analysis model is applied. The effects of heat rejection pressures, outlet temperatures of gas cooler and evaporating temperatures on the exergy loss, exergy efficiency and the coefficient of performance (COP) of the expansion turbine cycle are analyzed. It is found that the great percentages of exergy losses take place in the gas cooler and compressor. Moreover, heat rejection pressures, outlet temperatures of gas cooler and evaporating temperatures have strong influence on the exergy efficiency, COP and the exergy loss of each component. The analysis shows that there exists an optimal heat rejection pressure corresponding to the maximum exergy efficiency and COP, respectively. The results are of significance in providing theoretical basis for optimal design and the control of the transcritical carbon dioxide system with an expansion turbine. 展开更多
关键词 carbon dioxide transcritical refrigeration cycle expansion turbine exergy analysis
下载PDF
Thermodynamic Analysis and Comparison on Low Temperature CO_2-NH_3 Cascade Refrigeration Cycle
9
作者 查世彤 马一太 +1 位作者 申江 李敏霞 《Transactions of Tianjin University》 EI CAS 2003年第3期252-255,共4页
This paper is focused on the cascade refrigeration cycle using natural refrigerant CO 2-NH 3. The properties of refrigerants CO 2 and NH 3 are introduced and analyzed.CO 2 has the advantage in low stage of cascade ref... This paper is focused on the cascade refrigeration cycle using natural refrigerant CO 2-NH 3. The properties of refrigerants CO 2 and NH 3 are introduced and analyzed.CO 2 has the advantage in low stage of cascade refrigeration cycle due to its good characteristics and properties. The thermodynamic analysis results of the CO 2-NH 3 cascade refrigeration cycle demonstrates that the cycle has an optimum condensation temperature of low stage and also has an optimum flow rate ratio.By comparing with the R13-R22 and NH 3-NH 3 cascade refrigeration cycles, the mass flow rate ratio of CO 2-NH 3 is larger than those of R13-R22 and NH 3-NH 3, the theoretical COP of CO 2-NH 3 cascade refrigeration cycle is larger than that of the R13-R22 cascade cycle and smaller than that of the NH 3-NH 3 cascade cycle. But the real COP of CO 2-NH 3 cascade cycle will be higher than those of R13-R22 and NH 3-NH 3 because the specific volume of CO 2 at low temperature does not change much and its dynamic viscosity is also small. 展开更多
关键词 CO 2-NH 3 cascade refrigeration cycle thermodynamic analysis
下载PDF
Conceptual Design of 25-Barrel Pellet Injector with Cycle Refrigerator for HL-2A Tokamak
10
作者 肖正贵 朱根良 刘德权 《Plasma Science and Technology》 SCIE EI CAS CSCD 2006年第4期473-476,共4页
The preliminary design of a multi-barrels pellet injector with cycle refrigerator as an advanced plasma-fuelling tool for HL-2A tokamak has been proposed. The design aims at precise temperature control, easy operation... The preliminary design of a multi-barrels pellet injector with cycle refrigerator as an advanced plasma-fuelling tool for HL-2A tokamak has been proposed. The design aims at precise temperature control, easy operation with high reliability and high flexibility. GM-cycle refrigerator and pipe-gun structure have been employed to produce 25 pellets in 25 gun barrels simultaneously and the design aims. have been accomplished. Prime design principle, engineering parameters, structure and layout of the cryostat components as well as calculation of heat load for the cryostat are presented. 展开更多
关键词 pellet injector cycle refrigerator heat loss heat sink
下载PDF
Cooling High Power Dissipating Artificial Intelligence (AI) Chips Using Refrigerant
11
作者 Waheeb Mukatash Hussameddine Kabbani +4 位作者 Jochem Marc Massalt Matthew Moscoso Merari Mejia Robles Tyler Yang Charlie Nino 《Journal of Electronics Cooling and Thermal Control》 2024年第2期35-49,共15页
High power dissipating artificial intelligence (AI) chips require significant cooling to operate at maximum performance. Current trends regarding the integration of AI, as well as the power/cooling demands of high-per... High power dissipating artificial intelligence (AI) chips require significant cooling to operate at maximum performance. Current trends regarding the integration of AI, as well as the power/cooling demands of high-performing server systems pose an immense thermal challenge for cooling. The use of refrigerants as a direct-to-chip cooling method is investigated as a potential cooling solution for cooling AI chips. Using a vapor compression refrigeration system (VCRS), the coolant temperature will be sub-ambient thereby increasing the total cooling capacity. Coupled with the implementation of a direct-to-chip boiler, using refrigerants to cool AI server systems can materialize as a potential solution for current AI server cooling demands. In this study, a comparison of 8 different refrigerants: R-134a, R-153a, R-717, R-508B, R-22, R-12, R-410a, and R-1234yf is analyzed for optimal performance. A control theoretical VCRS model is created to assess variable refrigerants under the same operational conditions. From this model, the coefficient of performance (COP), required mass flow rate of refrigerant, work required by the compressor, and overall heat transfer coefficient is determined for all 8 refrigerants. Lastly, a comprehensive analysis is provided to determine the most optimal refrigerants for cooling applications. R-717, commonly known as Ammonia, was found to have the highest COP value thus proving to be the optimal refrigerant for cooling AI chips and high-performing server applications. 展开更多
关键词 Artificial Intelligence Thermal Control Server Systems Vapor Compression refrigeration cycle Server Cooling
下载PDF
Rare Earths and Magnetic Refrigeration 被引量:20
12
作者 Karl A Gschneidner Vitalij K Pecharsky 《Journal of Rare Earths》 SCIE EI CAS CSCD 2006年第6期641-647,共7页
Magnetic refrigeration is a revolutionary, efficient, environmentally friendly cooling technology, which is on the threshold of commercialization. The magnetic rare earth materials are utilized as the magnetic refrige... Magnetic refrigeration is a revolutionary, efficient, environmentally friendly cooling technology, which is on the threshold of commercialization. The magnetic rare earth materials are utilized as the magnetic refrigerants in most cooling devices, and for many cooling application the Nd2Fe14B permanent magnets are employed as the source of the magnetic field. The status of the near room temperature magnetic cooling was reviewed. 展开更多
关键词 magnetic refrigeration magnetocaloric effect GADOLINIUM Gd5 Si1- x Gex 4 La Fe 13 - x Six Hy Nd2 Fe14 B permanent magnets active magnetic regenerator cycle rare earths
下载PDF
Thermodynamic design of a cascade refrigeration system of liquefied natural gas by applying mixed integer non-linear programming 被引量:2
13
作者 Meysam Kamalinejad Majid Amidpour S.M.Mousavi Naeynian 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2015年第6期998-1008,共11页
Liquefied natural gas(LNG) is the most economical way of transporting natural gas(NG) over long distances. Liquefaction of NG using vapor compression refrigeration system requires high operating and capital cost. Due ... Liquefied natural gas(LNG) is the most economical way of transporting natural gas(NG) over long distances. Liquefaction of NG using vapor compression refrigeration system requires high operating and capital cost. Due to lack of systematic design methods for multistage refrigeration cycles, conventional approaches to determine optimal cycle are largely trial-and-error. In this paper a novel mixed integer non-linear programming(MINLP)model is introduced to select optimal synthesis of refrigeration systems to reduce both operating and capital costs of an LNG plant. Better conceptual understanding of design improvement is illustrated on composite curve(CC) and exergetic grand composite curve(EGCC) of pinch analysis diagrams. In this method a superstructure representation of complex refrigeration system is developed to select and optimize key decision variables in refrigeration cycles(i.e. partition temperature, compression configuration, refrigeration features, refrigerant flow rate and economic trade-off). Based on this method a program(LNG-Pro) is developed which integrates VBA,Refprop and Excel MINLP Solver to automate the methodology. Design procedure is applied on a sample LNG plant to illustrate advantages of using this method which shows a 3.3% reduction in total shaft work consumption. 展开更多
关键词 Cascade refrigeration cycle synthesis CRYOGENIC Liquefied natural gas MINLP
下载PDF
Performance comparison and analysis of a combined power and cooling system based on organic Rankine cycle 被引量:2
14
作者 王志奇 周奇遇 +2 位作者 夏小霞 刘斌 张欣 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第2期353-359,共7页
A novel power and cooling system combined system which coupled organic Rankine cycle(ORC) with vapor compression refrigeration cycle(VCRC) was proposed. R245 fa and butane were selected as the working fluid for the po... A novel power and cooling system combined system which coupled organic Rankine cycle(ORC) with vapor compression refrigeration cycle(VCRC) was proposed. R245 fa and butane were selected as the working fluid for the power and refrigeration cycle, respectively. A performance comparison and analysis for the combined system was presented. The results show that dual-pressure ORC-VCRC system can achieve an increase of 7.1% in thermal efficiency and 6.7% in exergy efficiency than that of basic ORC-VCRC. Intermediate pressure is a key parameter to both net power and exergy efficiency of dual-pressure ORC-VCRC system. Combined system can produce maximum net power and exergy efficiency at 0.85 MPa for intermediate pressure and 2.4 MPa for high pressure, respectively. However, superheated temperature at expander inlet has little impact on the two indicators. It can achieve higher overall COP, net power and exergy efficiency at smaller difference between condensation temperature and evaporation temperature of VCRC. 展开更多
关键词 dual-pressure organic Rankine cycle vapor compression refrigeration waste heat performance analysis
下载PDF
新型喷射循环(Eject Cycle~)车用冷冻机的开发 被引量:15
15
作者 池本彻 武内裕嗣 +3 位作者 西山鸟 春幸口池上真 松永久嗣 神谷博 《制冷技术》 2008年第1期19-26,共8页
喷射器循环是世界首创的高效新型制冷循环,通过回收膨胀过程中的动能,电装公司的新型车用冷冻机效率提高50%。
关键词 喷射器 高效率 制冷循环
下载PDF
Calculating the Refrigeration Coefficient by Using the Second Law of Thermodynamics
16
作者 杨洪海 尹世永 《Journal of Donghua University(English Edition)》 EI CAS 2007年第6期811-814,共4页
Refrigeration coefficient, ε, is usually calculated by using the First Law of Thermodynamics. In this paper, a new derivation process is introduced through the combination of the Second Law of Thermodynamics with the... Refrigeration coefficient, ε, is usually calculated by using the First Law of Thermodynamics. In this paper, a new derivation process is introduced through the combination of the Second Law of Thermodynamics with the First Law of Thermodynamics. As a result, two new calculation equations for refrigeration coefficient are proposed. One equation is equivalent to the common method, but its form is a little complicated for real calculation. Another equation is the further simplification, and can be used to calculate the refrigeration coefficient instead of common method with a oermit error. 展开更多
关键词 vapor-compression refrigeration cycle refrigeration coefficient Second Law of Thernxxlynamics refrigerANT
下载PDF
Analysis of R134a Organic Regenerative Cycle
17
作者 André Felippe Vieira da Cunha Sandino Lamarca Santos Souza 《Journal of Power and Energy Engineering》 2020年第5期32-45,共14页
The analysis of organic regenerative cycles is necessary to verify the possibilities of increasing the work and efficiency of a thermodynamic cycle according to some control parameters. The results obtained from this ... The analysis of organic regenerative cycles is necessary to verify the possibilities of increasing the work and efficiency of a thermodynamic cycle according to some control parameters. The results obtained from this work can be beneficial in several areas such as solar thermal energy. Simulations of an organic regenerative cycle with up to 4 extractions were carried out in order to analyze the behavior of maximum efficiency and the work generated in the turbine. R134a was used as an organic fluid, used in low temperature cycles. Evaporation temperature data between 60°C and 100°C and superheat temperatures equal to 120°C, 200°C and 300°C were tested for cycle analysis. Thus, it was possible to verify the work behavior and maximum efficiency depending on the number of extractions, superheating temperature and evaporation temperature. The models and simulations were made using the Engineering Equation Solver (EES) software and the results were analyzed in Excel. It was concluded that the maximum efficiency increases with the increase of the evaporation temperature and the number of extractions and decreases with the increase of the superheat temperature. The turbine work grows by increasing the evaporation and superheat temperatures, but decreases with the increase in extractions. 展开更多
关键词 SOLAR Energy REGENERATIVE ORGANIC Rankine cycle R134A refrigerANT
下载PDF
Refrigeration Performance Analysis and Its Applicability of a New Metal Hydride Couple in Auto Air-conditioning
18
作者 倪久建 陈江平 +3 位作者 陈芝久 覃峰 吕曼琪 杨柯 《Journal of Shanghai Jiaotong university(Science)》 EI 2005年第1期80-85,共6页
With COP and dynamic characteristics in refrigeration cycle as criteria,a new metal hydride couple——LaNi 4.61 Mn 0.26 Al 0.13 /La 0.6 Y 0.4 Ni 4.8 Mn 0.2 was selected by establishing calculation procedure and metal ... With COP and dynamic characteristics in refrigeration cycle as criteria,a new metal hydride couple——LaNi 4.61 Mn 0.26 Al 0.13 /La 0.6 Y 0.4 Ni 4.8 Mn 0.2 was selected by establishing calculation procedure and metal hydride selection model.The experimental results show that the refigeration cycle of the selected couple is good in the performance.The recovered waste heat and refrigeration power from exhaust gas of several kinds of automobile are calculated by waste-heat formula,coefficient R Q and COP.Refrigeration cycle of the new couple can satisfy the air-conditioning requirement of truck and car and is not enough in passenger car,according to the respective cooling load. 展开更多
关键词 metal hydried COUPLE refrigeration cycle coefficient of performance (COP)
下载PDF
Energetic and Exergetic Analysis of Organic Rankine Cycle Powered by Hot Geothermal Water
19
作者 Fathi Latrash Mohammed A. Al-Weshahi +1 位作者 Basim M.A Makhdoum Brian Agnew 《Journal of Energy and Power Engineering》 2014年第7期1217-1231,共15页
The paper presents an investigation of energy and exergy analysis of an existing ORC (organic rankine cycle) unit powered by hot geothermal water. The validated model of this unit was used to examine 25 refrigerants... The paper presents an investigation of energy and exergy analysis of an existing ORC (organic rankine cycle) unit powered by hot geothermal water. The validated model of this unit was used to examine 25 refrigerants belonging to different chemical compositions. The study revealed that R141b and R123 produced the best net power, energy efficiency, and exergy efficiency, whereas R125 was the lowest. Hydrofluorocarbons (except R143a), hydrocarbons, and inorganic reflected attractive energy and exergy efficiencies. All investigated mixtures gained low performance compared with other studied candidates. The R245ca was the best among the hydrofluorocarbons studied refrigerants, and R501 was the best among the mixture refrigerants. Furthermore, within the ORC system, the evaporator was found to have the highest exergy destruction and the refrigerant pump was the lowest. 展开更多
关键词 Organic Rankine cycle EXERGY ENERGY refrigerants.
下载PDF
新型低GWP制冷剂在-100~200℃的应用研究进展
20
作者 张迪 郭智恺 +4 位作者 于万金 卢朋 刘瑶瑶 刘武灿 张建君 《制冷学报》 CAS CSCD 北大核心 2024年第3期23-37,共15页
制冷剂是蒸气压缩循环中必不可少的工作流体,氢氟烷烃类化合物是目前制冷、空调和热泵设备中的主要制冷剂,但该类制冷剂会引起全球变暖等问题,因此亟需开发应用性能相似、环境性能友好的新型制冷剂。介绍了不同制冷剂在-100~200℃蒸气... 制冷剂是蒸气压缩循环中必不可少的工作流体,氢氟烷烃类化合物是目前制冷、空调和热泵设备中的主要制冷剂,但该类制冷剂会引起全球变暖等问题,因此亟需开发应用性能相似、环境性能友好的新型制冷剂。介绍了不同制冷剂在-100~200℃蒸气压缩循环应用场景中的使用现状,并综述了具有前景的低GWP制冷剂替代方案研究进展;在此基础上,对HFO-1234yf、HFO-1234ze(E)、HFO-1234ze(Z)、HCFO-1233zd(E)、HFO-1336mzz(Z) 5种低GWP制冷剂在实际应用系统中的最新研究及关键问题进行总结。 展开更多
关键词 制冷剂 空调 热泵 有机朗肯循环 GWP
下载PDF
上一页 1 2 51 下一页 到第
使用帮助 返回顶部