Based on a simplified 3-DOF model of twin-tower structure linked by a sky-bridge,the frequency response functions,the displacement power spectral density(PSD)functions,and the time-averaged total vibration energy were...Based on a simplified 3-DOF model of twin-tower structure linked by a sky-bridge,the frequency response functions,the displacement power spectral density(PSD)functions,and the time-averaged total vibration energy were derived,by assuming the white noise as the earthquake excitation.The effects of connecting parameters,such as linking stiffness ratio and linking damping ratio,on the structural vibration responses were then studied,and the optimal connecting parameters were obtained to minimize the vibration energy of either the independent monomer tower or the integral structure.The influences of sky-bridge elevation position on the optimal connecting parameters were also discussed.Finally,the distribution characteristics of the top displacement PSD and the structural responses,excited by El Centro,Taft and artificial waves,were compared in both frequency and time domain.It is found that the connecting parameters at either end of connection interactively affect the responses of the towers.The optimal connecting parameters can greatly improve the damping connections on their seismic reduction effectiveness,but are unable to reduce the seismic responses of the towers to the best extent simultaneously.It is also indicated that the optimal connecting parameters derived from the simplified 3-DOF model are applicable for two multi-story structures linked by a sky-bridge with dampers.The seismic reduction effectiveness obtained varies from 0.3 to 1.0 with different sky-bridge mass ratio.The displacement responses of the example structures are reduced by approximately 22% with sky-bridge connections.展开更多
基金Project(51178203)supported by the National Natural Science Foundation of China
文摘Based on a simplified 3-DOF model of twin-tower structure linked by a sky-bridge,the frequency response functions,the displacement power spectral density(PSD)functions,and the time-averaged total vibration energy were derived,by assuming the white noise as the earthquake excitation.The effects of connecting parameters,such as linking stiffness ratio and linking damping ratio,on the structural vibration responses were then studied,and the optimal connecting parameters were obtained to minimize the vibration energy of either the independent monomer tower or the integral structure.The influences of sky-bridge elevation position on the optimal connecting parameters were also discussed.Finally,the distribution characteristics of the top displacement PSD and the structural responses,excited by El Centro,Taft and artificial waves,were compared in both frequency and time domain.It is found that the connecting parameters at either end of connection interactively affect the responses of the towers.The optimal connecting parameters can greatly improve the damping connections on their seismic reduction effectiveness,but are unable to reduce the seismic responses of the towers to the best extent simultaneously.It is also indicated that the optimal connecting parameters derived from the simplified 3-DOF model are applicable for two multi-story structures linked by a sky-bridge with dampers.The seismic reduction effectiveness obtained varies from 0.3 to 1.0 with different sky-bridge mass ratio.The displacement responses of the example structures are reduced by approximately 22% with sky-bridge connections.