The two-phase flow instabilities observed in through parallel multichannel can be classified into three types,of which only one is intrinsic to parallel multichannel systems.The intrinsic instabilities observed in par...The two-phase flow instabilities observed in through parallel multichannel can be classified into three types,of which only one is intrinsic to parallel multichannel systems.The intrinsic instabilities observed in parallel multichannel system have been studied experimentally.The stable boundary of the flow in such a parallel-channel system are sought,and the nature of inlet flow oscillation in the unstable region has been examined experimentally under various conditions of inlet velocity,heat flux,liquid temperature,cross section of channel and entrance throttling.The results show that parallel multichannel system possess a characteristic oscillation that is quite independent of the magnitude and duration of the initial disturbance,and the stable boundary is influenced by the characteristic frequency of the system as well as by the exit quality when this is low,and upon raising the exit quality and reducing the characteristic frequency,the system increases its instability,and entrance throttling effectively contributes to stabilization of the system.展开更多
The competitive iodide/iodate reaction scheme was used to ascertain the micromixing in the stirred solid-liquid systems. Two different glass beads from 450 to 1250 μm were tested. The effect of solid particles on rea...The competitive iodide/iodate reaction scheme was used to ascertain the micromixing in the stirred solid-liquid systems. Two different glass beads from 450 to 1250 μm were tested. The effect of solid particles on reaction selectivity with multiple impellers at different feed points has been investigated. It was confirmed that glass beads as a second phase were suitable for the study. The segregation index has changed significantly only for the medium-sized particles at relatively high solid holdups. The cloud formation was clearly observed for the medium-sized particles at a concentration of 12.12 wt. %. When feeding into the clear liquid above the cloud, the value of the segregation index increased significantly. However, in the presence of particles of 1-1.25 mm, the influence on the selectivity was negligible when the agitation speed was increased.展开更多
In distributed parallel server system, location and redundancy of repficas have great influence on availability and efficiency of the system. In order to improve availability and efficiency of the system, two phase de...In distributed parallel server system, location and redundancy of repficas have great influence on availability and efficiency of the system. In order to improve availability and efficiency of the system, two phase decision algorithm of replica allocation is proposed. The algorithm which makes use of auto-regression model dynamically predicts the future count of READ and WRITE operation, and then determines location and redundancy of replicas by considering availability, CPU and bands of the network. The algorithm can not only ensure the requirement of availability, but also reduce the system resources consumed by all the operations in a great scale. Analysis and test show that communication complexity and time complexity of the algorithm satisfy O(n), resource optimizing scale increases with the increase of READ count.展开更多
This paper is concerned with three-dimensional numerical simulation of a plunging liquid jet. The transient processes of forming an air cavity around the jet, capturing an initially large air bubble, and the break-up ...This paper is concerned with three-dimensional numerical simulation of a plunging liquid jet. The transient processes of forming an air cavity around the jet, capturing an initially large air bubble, and the break-up of this large toroidal-shaped bubble into smaller bubbles were analyzed. A stabilized finite element method (FEM) was employed under parallel numerical simulations based on adaptive, unstructured grid and coupled with a level-set method to track the interface between air and liquid. These simulations show that the inertia of the liquid jet initially depresses the pool's surface, forming an annular air cavity which surrounds the liquid jet. A toroidal liquid eddy which is subse- quently formed in the liquid pool results in air cavity collapse, and in turn entrains air into the liquid pool from the unstable annular air gap region around the liquid jet.展开更多
文摘The two-phase flow instabilities observed in through parallel multichannel can be classified into three types,of which only one is intrinsic to parallel multichannel systems.The intrinsic instabilities observed in parallel multichannel system have been studied experimentally.The stable boundary of the flow in such a parallel-channel system are sought,and the nature of inlet flow oscillation in the unstable region has been examined experimentally under various conditions of inlet velocity,heat flux,liquid temperature,cross section of channel and entrance throttling.The results show that parallel multichannel system possess a characteristic oscillation that is quite independent of the magnitude and duration of the initial disturbance,and the stable boundary is influenced by the characteristic frequency of the system as well as by the exit quality when this is low,and upon raising the exit quality and reducing the characteristic frequency,the system increases its instability,and entrance throttling effectively contributes to stabilization of the system.
文摘The competitive iodide/iodate reaction scheme was used to ascertain the micromixing in the stirred solid-liquid systems. Two different glass beads from 450 to 1250 μm were tested. The effect of solid particles on reaction selectivity with multiple impellers at different feed points has been investigated. It was confirmed that glass beads as a second phase were suitable for the study. The segregation index has changed significantly only for the medium-sized particles at relatively high solid holdups. The cloud formation was clearly observed for the medium-sized particles at a concentration of 12.12 wt. %. When feeding into the clear liquid above the cloud, the value of the segregation index increased significantly. However, in the presence of particles of 1-1.25 mm, the influence on the selectivity was negligible when the agitation speed was increased.
文摘In distributed parallel server system, location and redundancy of repficas have great influence on availability and efficiency of the system. In order to improve availability and efficiency of the system, two phase decision algorithm of replica allocation is proposed. The algorithm which makes use of auto-regression model dynamically predicts the future count of READ and WRITE operation, and then determines location and redundancy of replicas by considering availability, CPU and bands of the network. The algorithm can not only ensure the requirement of availability, but also reduce the system resources consumed by all the operations in a great scale. Analysis and test show that communication complexity and time complexity of the algorithm satisfy O(n), resource optimizing scale increases with the increase of READ count.
基金supported by the Office of Naval Research(Grant ONRDC14292111)
文摘This paper is concerned with three-dimensional numerical simulation of a plunging liquid jet. The transient processes of forming an air cavity around the jet, capturing an initially large air bubble, and the break-up of this large toroidal-shaped bubble into smaller bubbles were analyzed. A stabilized finite element method (FEM) was employed under parallel numerical simulations based on adaptive, unstructured grid and coupled with a level-set method to track the interface between air and liquid. These simulations show that the inertia of the liquid jet initially depresses the pool's surface, forming an annular air cavity which surrounds the liquid jet. A toroidal liquid eddy which is subse- quently formed in the liquid pool results in air cavity collapse, and in turn entrains air into the liquid pool from the unstable annular air gap region around the liquid jet.