A spherical Si solar cell with a reflector cup was successfully fabricated by a dropping method at decompression state. In the dropping method, melted Si droplets were instilled at decompression state (0.5×105 Pa...A spherical Si solar cell with a reflector cup was successfully fabricated by a dropping method at decompression state. In the dropping method, melted Si droplets were instilled at decompression state (0.5×105 Pa) to reduce crystal growth rate, dominating crystal quality such as dislocation density in crystal grains. Spherical Si solar cells were fabricated using the spherical Si crystals with a diameter of 1 mm and then mounted on a reflector cup. The current-voltage measurement of the solar cell shows an energy conversion efficiency of 11.1% (short-circuit current density (Jsc): 24.7 mA·cm-2, open-circuit voltage: 601 mV, fill factor: 74.6%). Minority carrier diffusion length determined by surface photovoltage method was 98 μm. This value can be enhanced by the improvement of crystal quality of spherical Si crystals. These results demonstrate that spherical Si crystals fabricated by the dropping method has a great potential for substrate material of high-efficiency and low-cost solar cells.展开更多
Animals’ regional femur blood (F) alteration was studied under an inadequate decompression by using the inhaled isotope 133Xe washout method. Results showed that the average F on left and right side of minipigs’ fem...Animals’ regional femur blood (F) alteration was studied under an inadequate decompression by using the inhaled isotope 133Xe washout method. Results showed that the average F on left and right side of minipigs’ femur decreased from 15.4±1.8 and 16 .9±2.0 ml/ (100 g.min) (before exposure) to 10±1.8 and 11.1±1.6 ml/(100mg.min) (after expposure for 1.5 h under the pressure of 0.5 MPa and then decompression to normal with the rate of 0.03~0.04MPa/min), respectively; the blood flow of hematopoietic marrow tissues (f1)on both sides also decreased from 19.3±2.0 and 22.1±1.9 ml/(100mg.min) to 13.9±1.4 and 13.8±1.0 ml/(100 mg.min). The exact same alteration also happened in the experiment on New Zealand rabbits. It indicates that inadequate decompression in hyperbaric exposure can give rise to decrease animals’ bone blood flow and insufficient bone blood supply serves as one of the reasons for causing decompressive osteonecrosis.展开更多
Grains are widely present in industrial productions and processing,and are stored in silos.In the silo,auxiliary structures are added to achieve efficient production.However,little effort has been devoted to the influ...Grains are widely present in industrial productions and processing,and are stored in silos.In the silo,auxiliary structures are added to achieve efficient production.However,little effort has been devoted to the influence of the internal structure of the silo on the granular flow.In this work,a silo with a central decompression tube is studied through experimental measurements and discrete element methods.Then,the influences of the central decompression tube on the flow behavior of grains and wall pressure are analyzed.Results show that the grains are in mass flow in the silo without a central decompression tube,while the grains are in funnel flow in the silo with a central decompression tube.Moreover,regardless of whether there is a central decompression tube in the silo,the maximum pressure appears at the top of the conical silo.In the lower part of the silo,the wall pressure of the silo with a central decompression tube is lower than that of the silo without a central decompression tube.Therefore,a silo with a central decompression tube is more conducive to grain storage and discharge than a silo without a central decompression tube.展开更多
In this study, the concept of a new seawater desalination method and equipment using liquid columns of seawater and desalinated fresh water, decompression boiling and evaporation, condensation, and recovery of condens...In this study, the concept of a new seawater desalination method and equipment using liquid columns of seawater and desalinated fresh water, decompression boiling and evaporation, condensation, and recovery of condensation latent heat are proposed. The equipment consists of seawater and freshwater columns approximately 10 m high with top spaces. The pressure of the top space, the evaporation and condensation area, of the seawater column, for example, is reduced approximately 30 mmHg (abs.) using the seawater column, after which it is heated from the general seawater temperature of 25°C to 30°C to boil and evaporate the seawater. The vapor is cooled by the seawater at approximately 25°C in a heat exchanger, and then, it is condensed and sent to the fresh water column. At this time, the condensation latent heat is recovered to preheat the newly flowing seawater. The evaporation or condensation rate, namely, the production rate of freshwater, by the new desalination equipment is also estimated by the results of the existing quadruplex effect vacuum evaporator used in the salt production industry. This new desalination method and its associated equipment also can be used to purify polluted water and waste water.展开更多
Two-Line Element(TLE)datasets are the only orbital data source of Earth-orbiting space objects for many civil users for their research and applications.The datasets have uneven qualities that may affect the reliabilit...Two-Line Element(TLE)datasets are the only orbital data source of Earth-orbiting space objects for many civil users for their research and applications.The datasets have uneven qualities that may affect the reliability of the propagated positions of space objects using a single TLE.The least squares approach to use multiple TLEs also suffers from the poor quality of some TLEs,and reliable error information cannot be available.This paper proposes a simplex algorithm to estimate an optimal TLE from multiple TLEs and obtain the uncertainty of each element.It is a derivative-free technique that can deal with various orbit types.Experiments have demonstrated that using the TLE estimated from the simplex method is more reliable,stable,and effective than those from the batch least squares method.As an application example,the optimal TLE and its uncertainty are used for predicting the fallen area,keeping the actual fallen site in the prediction areas.展开更多
基金This work was partly financially supported by NEDO.
文摘A spherical Si solar cell with a reflector cup was successfully fabricated by a dropping method at decompression state. In the dropping method, melted Si droplets were instilled at decompression state (0.5×105 Pa) to reduce crystal growth rate, dominating crystal quality such as dislocation density in crystal grains. Spherical Si solar cells were fabricated using the spherical Si crystals with a diameter of 1 mm and then mounted on a reflector cup. The current-voltage measurement of the solar cell shows an energy conversion efficiency of 11.1% (short-circuit current density (Jsc): 24.7 mA·cm-2, open-circuit voltage: 601 mV, fill factor: 74.6%). Minority carrier diffusion length determined by surface photovoltage method was 98 μm. This value can be enhanced by the improvement of crystal quality of spherical Si crystals. These results demonstrate that spherical Si crystals fabricated by the dropping method has a great potential for substrate material of high-efficiency and low-cost solar cells.
文摘Animals’ regional femur blood (F) alteration was studied under an inadequate decompression by using the inhaled isotope 133Xe washout method. Results showed that the average F on left and right side of minipigs’ femur decreased from 15.4±1.8 and 16 .9±2.0 ml/ (100 g.min) (before exposure) to 10±1.8 and 11.1±1.6 ml/(100mg.min) (after expposure for 1.5 h under the pressure of 0.5 MPa and then decompression to normal with the rate of 0.03~0.04MPa/min), respectively; the blood flow of hematopoietic marrow tissues (f1)on both sides also decreased from 19.3±2.0 and 22.1±1.9 ml/(100mg.min) to 13.9±1.4 and 13.8±1.0 ml/(100 mg.min). The exact same alteration also happened in the experiment on New Zealand rabbits. It indicates that inadequate decompression in hyperbaric exposure can give rise to decrease animals’ bone blood flow and insufficient bone blood supply serves as one of the reasons for causing decompressive osteonecrosis.
基金We would like to acknowledge the finical support by the Key Laboratory of Agro-Products Postharvest Handling,Ministry of Agriculture support(Grant No.KLAPPH2-2017-04).
文摘Grains are widely present in industrial productions and processing,and are stored in silos.In the silo,auxiliary structures are added to achieve efficient production.However,little effort has been devoted to the influence of the internal structure of the silo on the granular flow.In this work,a silo with a central decompression tube is studied through experimental measurements and discrete element methods.Then,the influences of the central decompression tube on the flow behavior of grains and wall pressure are analyzed.Results show that the grains are in mass flow in the silo without a central decompression tube,while the grains are in funnel flow in the silo with a central decompression tube.Moreover,regardless of whether there is a central decompression tube in the silo,the maximum pressure appears at the top of the conical silo.In the lower part of the silo,the wall pressure of the silo with a central decompression tube is lower than that of the silo without a central decompression tube.Therefore,a silo with a central decompression tube is more conducive to grain storage and discharge than a silo without a central decompression tube.
文摘In this study, the concept of a new seawater desalination method and equipment using liquid columns of seawater and desalinated fresh water, decompression boiling and evaporation, condensation, and recovery of condensation latent heat are proposed. The equipment consists of seawater and freshwater columns approximately 10 m high with top spaces. The pressure of the top space, the evaporation and condensation area, of the seawater column, for example, is reduced approximately 30 mmHg (abs.) using the seawater column, after which it is heated from the general seawater temperature of 25°C to 30°C to boil and evaporate the seawater. The vapor is cooled by the seawater at approximately 25°C in a heat exchanger, and then, it is condensed and sent to the fresh water column. At this time, the condensation latent heat is recovered to preheat the newly flowing seawater. The evaporation or condensation rate, namely, the production rate of freshwater, by the new desalination equipment is also estimated by the results of the existing quadruplex effect vacuum evaporator used in the salt production industry. This new desalination method and its associated equipment also can be used to purify polluted water and waste water.
基金supported by Chongqing Municipal Natural Science Foundation of General Program(CSTB2022NSCQMSX1093)the Science and Technology Research Program of Chongqing Municipal Education Commission(Grant No.KJQN202200701)China Postdoctoral Science Foundation(2021M703487).
文摘Two-Line Element(TLE)datasets are the only orbital data source of Earth-orbiting space objects for many civil users for their research and applications.The datasets have uneven qualities that may affect the reliability of the propagated positions of space objects using a single TLE.The least squares approach to use multiple TLEs also suffers from the poor quality of some TLEs,and reliable error information cannot be available.This paper proposes a simplex algorithm to estimate an optimal TLE from multiple TLEs and obtain the uncertainty of each element.It is a derivative-free technique that can deal with various orbit types.Experiments have demonstrated that using the TLE estimated from the simplex method is more reliable,stable,and effective than those from the batch least squares method.As an application example,the optimal TLE and its uncertainty are used for predicting the fallen area,keeping the actual fallen site in the prediction areas.