The flow through a rotating U bend duct is investigated by means of visualization. The U bend duct has a cross section of 50 mm×50 mm and a ratio of bend mean radius R c to hydraulic diameter of the duct D of ...The flow through a rotating U bend duct is investigated by means of visualization. The U bend duct has a cross section of 50 mm×50 mm and a ratio of bend mean radius R c to hydraulic diameter of the duct D of 0.65. The rotation axis is parallel with the bend axis. Three cases with rotation number of Ro=-0.2, 0 and 0.2, respectively, are studied at a Reynolds number of 100 000. The results show that the combined effect of rotation and bend curvature strongly influences the flow field, especially in the downstream region of the bend. The evident difference among the flow patterns with different rotation number shows that the secondary flow induced by Coriolis force takes an important role in determining the flow structure.展开更多
文摘The flow through a rotating U bend duct is investigated by means of visualization. The U bend duct has a cross section of 50 mm×50 mm and a ratio of bend mean radius R c to hydraulic diameter of the duct D of 0.65. The rotation axis is parallel with the bend axis. Three cases with rotation number of Ro=-0.2, 0 and 0.2, respectively, are studied at a Reynolds number of 100 000. The results show that the combined effect of rotation and bend curvature strongly influences the flow field, especially in the downstream region of the bend. The evident difference among the flow patterns with different rotation number shows that the secondary flow induced by Coriolis force takes an important role in determining the flow structure.