Strawberry Fusarium wilt (SFW) is a systematic soil-borne disease caused by Fusarium oxysporum f.sp.fragaria (Fof),which infects the vascular bundles,blocking water and nutrient transport from roots to the aboveground...Strawberry Fusarium wilt (SFW) is a systematic soil-borne disease caused by Fusarium oxysporum f.sp.fragaria (Fof),which infects the vascular bundles,blocking water and nutrient transport from roots to the aboveground.It is a severe pathogen which spreads rapidly and destroys strawberry production.Finding a way to control this disease is of great scientific value and practical importance.In this study,three fungi were isolated from the vascular tissues of sick strawberries in the field.After DNA sequencing,they were identified as Fof,Aspergillus fumigatus and Trichoderma harzianum,respectively,among which the first two are pathogens and the third is a probiotic.All fungi were controlled by thiophanate-methyl (TM),a commercial fungicide.On PDA medium,20 mg·L^(-1)5-aminolevulinic acid (ALA),a natural non-protein amino acid,promoted T.harzianum proliferation,but inhibited Fof and A.fumigatus.In confrontation test,the growth of Fof or A.fumigatus was inhibited by T.harzianum and exogenous ALA promoted T.harzianum growth but significantly inhibited the pathogen growth.When three species of fungi were separately or combinedly inoculated on healthy strawberry plants,T.harzianum promoted plant growth and development while Fof or A.fumigatus caused growth retardation,where Fof directly caused leaf yellowing and plant wilting.When the plants inoculated with different fungus were treated with ALA,the results turned out that ALA alleviated SFW symptoms by bidirectionally promoting T.harzianum proliferation and inhibiting Fof and A.fumigatus.Thus,ALA might be used in comprehensively controlling SFW in strawberry industry.展开更多
基于模块化多电平换流器的高压柔性直流输电系统(modular multilevel converter-based high voltage direct current,MMC-HVDC)常采用双极接线方式以提高系统功率输送能力和可靠性。然而目前对于风电场经柔直外送系统的稳定性研究集中...基于模块化多电平换流器的高压柔性直流输电系统(modular multilevel converter-based high voltage direct current,MMC-HVDC)常采用双极接线方式以提高系统功率输送能力和可靠性。然而目前对于风电场经柔直外送系统的稳定性研究集中于单极接线方式,孤岛直驱风电场与采用不同双极协调控制的双极MMC-HVDC互联系统小信号稳定性问题还有待进一步探究。该文首先考虑频率耦合特性、参考系初相位和直流侧耦合特性的影响,分别建立了采用双U/f下垂控制和定U/f-P/Q控制的双极MMC-HVDC系统交流侧等效SISO阻抗模型,并详细分析了金属回线阻抗和双极间功率均分度对交流阻抗特性的影响。接着对比研究了两种协调控制中共有控制环路和特有控制环路对交流侧负电阻特性及互联系统稳定性的影响规律。最后,孤岛直驱风电场经两种双极协调控制下双极MMC-HVDC外送系统Matlab/Simulink时域仿真结果和硬件在环半实物实时仿真实验结果验证了所提出的小信号阻抗模型的精确性和稳定性分析结论的有效性。展开更多
The fuzzy neural networks has been used as means of precisely controlling the air-fuel ratio of a lean-burn compressed natural gas (CNG) engine. A control algorithm, without based on engine model, has been (utilized) ...The fuzzy neural networks has been used as means of precisely controlling the air-fuel ratio of a lean-burn compressed natural gas (CNG) engine. A control algorithm, without based on engine model, has been (utilized) to construct a feedforward/feedback control scheme to regulate the air-fuel ratio. Using fuzzy neural networks, a fuzzy neural hybrid controller is obtained based on PI controller. The new controller, which can adjust parameters online, has been tested in transient air-fuel ratio control of a CNG engine.展开更多
In the course of the cryoplant modernization, a control network will be set up in order to facilitate the control, the supervision, the centralized data acquisition and the alarm handling of the cryogenic system for H...In the course of the cryoplant modernization, a control network will be set up in order to facilitate the control, the supervision, the centralized data acquisition and the alarm handling of the cryogenic system for HT-7U tokamak. The paper introduces the preliminary design of control network based on the Controller Link Network for HT-7U tokamak cryogenic system. The multi-layer structure mentioned in the paper is the mainstream of automatic control. The control philosophy, the structure of the network and the components for control are also presented.展开更多
The vertical position of plasma in the HT-7U Tokamak is inherently unstable. In order to realize active stabilization, the response rate of the high-power high-frequency amplifier feeding the active control coils must...The vertical position of plasma in the HT-7U Tokamak is inherently unstable. In order to realize active stabilization, the response rate of the high-power high-frequency amplifier feeding the active control coils must be fast enough. This paper analyzes the paralleling scheme of the power amplifier through two kinds of control mode. One is the synchronous control; the other is the asynchronous control. Via the comparison of the two kinds of control mode, both of their characteristics are given in the text. At last, the analyzed result is verified by a small power experiment.展开更多
The vascular fusariosis is one of the main obstacles in the tomato crop production. Currently, the management of the nutrient solution is presented as a control option for fusariosis, for such reason different nutrien...The vascular fusariosis is one of the main obstacles in the tomato crop production. Currently, the management of the nutrient solution is presented as a control option for fusariosis, for such reason different nutrient solutions with nitrogen (N), phosphorus (P), potassium (K) and calcium (Ca) modifications;in four saladette tomato varieties Bony Best (BB), Manapal (M), Walter (W) and FLA were evaluated in this research, in order to analyze the damage caused by Fusarium oxysporum f.sp. lycopersici (FOL) severity. Tomato plants were inoculated with 3 FOL breeds, establishing a completely random design with a factorial arrangement with six repetitions. Disease’s severity was evaluated 30 days after the inoculation using levels of (0 - 4) of the methodology established by Marlatt and Correll (1988). Afterwards, a statistical analysis was done through the Kruskal Wallis test, in which it was observed that treatments 93 (Ca 207 mg∙L<sup>-1</sup>, R3, variety BB), 95 (207 mg∙L<sup>-1</sup> Ca, R3, variety W), 81 (0Ca, R3, BB) showed less disease severity. In the foliar analysis, the best treatments were 22 (193 mg∙L<sup>-1</sup> N, R3, M) for N, the greatest P content was treatment 94 (207 mg∙L<sup>-1</sup> Ca, R3, M) for K treatment three and 93 (207 mg∙L<sup>-1</sup> Ca, R3, variety BB) greatest Ca content.展开更多
Intelligent vehicles can effectively improve traffic congestion and road traffic safety.Adaptive cruise followingcontrol(ACFC)is a vital part of intelligent vehicles.In this paper,a new hierarchical vehicle-following ...Intelligent vehicles can effectively improve traffic congestion and road traffic safety.Adaptive cruise followingcontrol(ACFC)is a vital part of intelligent vehicles.In this paper,a new hierarchical vehicle-following control strategy is presented by synthesizing the variable time headway model,type-2 fuzzy control,feedforward+fuzzy proportion integration(PI)feedback(F+FPIF)control,and inverse longitudinal dynamics model of vehicles.Firstly,a traditional variable time headway model is improved considering the acceleration of the lead car.Secondly,an interval type-2 fuzzy logic controller(IT2 FLC)is designed for the upper structure of the ACFC system to simulate the driver's operating habits.To reduce the nonlinear influence and improve the tracking accuracy for the desired acceleration,the control strategy of F+FPIF is given for the lower control structure.Thirdly,the lower control method proposed in this paper is compared with the fuzzy PI control and the traditional method(no lower controller for tracking desired acceleration)separately.Meanwhile,the proportion integration differentiation(PID),linear quadratic regulator(LQR),subsection function control(SFC)and type-1 fuzzy logic control(T1 FLC)are respectively compared with the IT2 FLC in control performance under different scenes.Finally,the simulation results show the effectiveness of IT2 FLC for the upper structure and F+FPIF control for the lower structure.展开更多
The main symptoms of root rot,anthracnose,blight and damping-off of Panax notoginseng( Burk) F. H. Chen are introduced in the paper,and the corresponding control measures are elaborated from the aspects of agricultura...The main symptoms of root rot,anthracnose,blight and damping-off of Panax notoginseng( Burk) F. H. Chen are introduced in the paper,and the corresponding control measures are elaborated from the aspects of agricultural management measures,seed disinfection,seedbed treatment and chemical control.展开更多
A biocontrol strain HJX1,which had good inhibitory effect against Fusarium oxysporum f. sp. cubense,was identified as Bacillus subtilis based on traditional morphology,16 S rRNA gene sequence and fatty acid profiles. ...A biocontrol strain HJX1,which had good inhibitory effect against Fusarium oxysporum f. sp. cubense,was identified as Bacillus subtilis based on traditional morphology,16 S rRNA gene sequence and fatty acid profiles. The sequence of 16 S rRNA gene had 99% homology to B. subtilis according to the DNA fragment of 1 521 bp amplified with a pair of universal primers,P0 and P6,of bacteria. Confront culture with pathogenic fungi showed that this strain had good inhibitory effect against 10 pathogenic fungi.展开更多
This paper proposes a case study in the control of a heavy oil pyrolysis/cracking furnace with a newly extended U-model based pole placement controller(U-PPC). The major work of the paper includes: 1) establishing a c...This paper proposes a case study in the control of a heavy oil pyrolysis/cracking furnace with a newly extended U-model based pole placement controller(U-PPC). The major work of the paper includes: 1) establishing a control oriented nonlinear dynamic model with Naphtha cracking and thermal dynamics; 2) analysing a U-model(i.e., control oriented prototype) representation of various popular process model sets; 3)designing the new U-PPC to enhance the control performance in pole placement and stabilisation; 4) taking computational bench tests to demonstrate the control system design and performance with a user-friendly step by step procedure.展开更多
The heterogeneous network with the separation of the control plane and user plane(C/U) is an evolutionary approach to the fifth generation(5 G) to achieve high system coverage and capacity. To minimize signaling load ...The heterogeneous network with the separation of the control plane and user plane(C/U) is an evolutionary approach to the fifth generation(5 G) to achieve high system coverage and capacity. To minimize signaling load of the core network when there is a macro base station(BS) failure in the control plane, a scheme of transferring the control of small cells under the coverage of the failure macro BS to the neighbor macro BSs is proposed. The average handover rates between small cells related to user mobilities, the extended coverage of the neighboring macro BSs under the constraint of transmitting power and the load balance index of the system are analyzed, based on which the formula of maximizing the handovers processed by macro BSs is constructed and further solved by the convex optimization methods. Simulation results indicate that the proposed scheme can effectively increase the total handovers processed by the macro BSs and thus reduce the signaling load of the core network.展开更多
基金funded by the Natural Science Foundation of China (Grant No.32172512)the Jiangsu Agricultural Science and Technology Innovation Fund[Grant No.CX(20)2023]+1 种基金the Jiangsu Special Fund for Frontier Foundation Research of Carbon Peaking and Carbon Neutralization (Grant No.BK20220005)a project funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions。
文摘Strawberry Fusarium wilt (SFW) is a systematic soil-borne disease caused by Fusarium oxysporum f.sp.fragaria (Fof),which infects the vascular bundles,blocking water and nutrient transport from roots to the aboveground.It is a severe pathogen which spreads rapidly and destroys strawberry production.Finding a way to control this disease is of great scientific value and practical importance.In this study,three fungi were isolated from the vascular tissues of sick strawberries in the field.After DNA sequencing,they were identified as Fof,Aspergillus fumigatus and Trichoderma harzianum,respectively,among which the first two are pathogens and the third is a probiotic.All fungi were controlled by thiophanate-methyl (TM),a commercial fungicide.On PDA medium,20 mg·L^(-1)5-aminolevulinic acid (ALA),a natural non-protein amino acid,promoted T.harzianum proliferation,but inhibited Fof and A.fumigatus.In confrontation test,the growth of Fof or A.fumigatus was inhibited by T.harzianum and exogenous ALA promoted T.harzianum growth but significantly inhibited the pathogen growth.When three species of fungi were separately or combinedly inoculated on healthy strawberry plants,T.harzianum promoted plant growth and development while Fof or A.fumigatus caused growth retardation,where Fof directly caused leaf yellowing and plant wilting.When the plants inoculated with different fungus were treated with ALA,the results turned out that ALA alleviated SFW symptoms by bidirectionally promoting T.harzianum proliferation and inhibiting Fof and A.fumigatus.Thus,ALA might be used in comprehensively controlling SFW in strawberry industry.
文摘基于模块化多电平换流器的高压柔性直流输电系统(modular multilevel converter-based high voltage direct current,MMC-HVDC)常采用双极接线方式以提高系统功率输送能力和可靠性。然而目前对于风电场经柔直外送系统的稳定性研究集中于单极接线方式,孤岛直驱风电场与采用不同双极协调控制的双极MMC-HVDC互联系统小信号稳定性问题还有待进一步探究。该文首先考虑频率耦合特性、参考系初相位和直流侧耦合特性的影响,分别建立了采用双U/f下垂控制和定U/f-P/Q控制的双极MMC-HVDC系统交流侧等效SISO阻抗模型,并详细分析了金属回线阻抗和双极间功率均分度对交流阻抗特性的影响。接着对比研究了两种协调控制中共有控制环路和特有控制环路对交流侧负电阻特性及互联系统稳定性的影响规律。最后,孤岛直驱风电场经两种双极协调控制下双极MMC-HVDC外送系统Matlab/Simulink时域仿真结果和硬件在环半实物实时仿真实验结果验证了所提出的小信号阻抗模型的精确性和稳定性分析结论的有效性。
文摘The fuzzy neural networks has been used as means of precisely controlling the air-fuel ratio of a lean-burn compressed natural gas (CNG) engine. A control algorithm, without based on engine model, has been (utilized) to construct a feedforward/feedback control scheme to regulate the air-fuel ratio. Using fuzzy neural networks, a fuzzy neural hybrid controller is obtained based on PI controller. The new controller, which can adjust parameters online, has been tested in transient air-fuel ratio control of a CNG engine.
基金National 863-803 Project of China(No.2002AA834020)
文摘In the course of the cryoplant modernization, a control network will be set up in order to facilitate the control, the supervision, the centralized data acquisition and the alarm handling of the cryogenic system for HT-7U tokamak. The paper introduces the preliminary design of control network based on the Controller Link Network for HT-7U tokamak cryogenic system. The multi-layer structure mentioned in the paper is the mainstream of automatic control. The control philosophy, the structure of the network and the components for control are also presented.
基金The project supported by the National Meg-Science Engineering Project of Chinese Goverment
文摘The vertical position of plasma in the HT-7U Tokamak is inherently unstable. In order to realize active stabilization, the response rate of the high-power high-frequency amplifier feeding the active control coils must be fast enough. This paper analyzes the paralleling scheme of the power amplifier through two kinds of control mode. One is the synchronous control; the other is the asynchronous control. Via the comparison of the two kinds of control mode, both of their characteristics are given in the text. At last, the analyzed result is verified by a small power experiment.
文摘The vascular fusariosis is one of the main obstacles in the tomato crop production. Currently, the management of the nutrient solution is presented as a control option for fusariosis, for such reason different nutrient solutions with nitrogen (N), phosphorus (P), potassium (K) and calcium (Ca) modifications;in four saladette tomato varieties Bony Best (BB), Manapal (M), Walter (W) and FLA were evaluated in this research, in order to analyze the damage caused by Fusarium oxysporum f.sp. lycopersici (FOL) severity. Tomato plants were inoculated with 3 FOL breeds, establishing a completely random design with a factorial arrangement with six repetitions. Disease’s severity was evaluated 30 days after the inoculation using levels of (0 - 4) of the methodology established by Marlatt and Correll (1988). Afterwards, a statistical analysis was done through the Kruskal Wallis test, in which it was observed that treatments 93 (Ca 207 mg∙L<sup>-1</sup>, R3, variety BB), 95 (207 mg∙L<sup>-1</sup> Ca, R3, variety W), 81 (0Ca, R3, BB) showed less disease severity. In the foliar analysis, the best treatments were 22 (193 mg∙L<sup>-1</sup> N, R3, M) for N, the greatest P content was treatment 94 (207 mg∙L<sup>-1</sup> Ca, R3, M) for K treatment three and 93 (207 mg∙L<sup>-1</sup> Ca, R3, variety BB) greatest Ca content.
基金the National Natural Science Foundation of China(61473048,61074093,61873321)。
文摘Intelligent vehicles can effectively improve traffic congestion and road traffic safety.Adaptive cruise followingcontrol(ACFC)is a vital part of intelligent vehicles.In this paper,a new hierarchical vehicle-following control strategy is presented by synthesizing the variable time headway model,type-2 fuzzy control,feedforward+fuzzy proportion integration(PI)feedback(F+FPIF)control,and inverse longitudinal dynamics model of vehicles.Firstly,a traditional variable time headway model is improved considering the acceleration of the lead car.Secondly,an interval type-2 fuzzy logic controller(IT2 FLC)is designed for the upper structure of the ACFC system to simulate the driver's operating habits.To reduce the nonlinear influence and improve the tracking accuracy for the desired acceleration,the control strategy of F+FPIF is given for the lower control structure.Thirdly,the lower control method proposed in this paper is compared with the fuzzy PI control and the traditional method(no lower controller for tracking desired acceleration)separately.Meanwhile,the proportion integration differentiation(PID),linear quadratic regulator(LQR),subsection function control(SFC)and type-1 fuzzy logic control(T1 FLC)are respectively compared with the IT2 FLC in control performance under different scenes.Finally,the simulation results show the effectiveness of IT2 FLC for the upper structure and F+FPIF control for the lower structure.
文摘The main symptoms of root rot,anthracnose,blight and damping-off of Panax notoginseng( Burk) F. H. Chen are introduced in the paper,and the corresponding control measures are elaborated from the aspects of agricultural management measures,seed disinfection,seedbed treatment and chemical control.
基金Supported by Culture Fund of Hainan Medical College for Scientific Researchin 2013(HY2013-22)
文摘A biocontrol strain HJX1,which had good inhibitory effect against Fusarium oxysporum f. sp. cubense,was identified as Bacillus subtilis based on traditional morphology,16 S rRNA gene sequence and fatty acid profiles. The sequence of 16 S rRNA gene had 99% homology to B. subtilis according to the DNA fragment of 1 521 bp amplified with a pair of universal primers,P0 and P6,of bacteria. Confront culture with pathogenic fungi showed that this strain had good inhibitory effect against 10 pathogenic fungi.
基金partially supported by the National Natural Science Foundation of China(61273188,61473312)Taishan Scholar Construction Engineering Special Funding of Shandong
文摘This paper proposes a case study in the control of a heavy oil pyrolysis/cracking furnace with a newly extended U-model based pole placement controller(U-PPC). The major work of the paper includes: 1) establishing a control oriented nonlinear dynamic model with Naphtha cracking and thermal dynamics; 2) analysing a U-model(i.e., control oriented prototype) representation of various popular process model sets; 3)designing the new U-PPC to enhance the control performance in pole placement and stabilisation; 4) taking computational bench tests to demonstrate the control system design and performance with a user-friendly step by step procedure.
基金Supported by Basic Research Program of BJUT(No.040000546317525)National Natural Science Foundation of China(No.61571021)+1 种基金Foundation of Beijing Municipal Commission of Education(No.KM201610005004,KM201510005006)Beijing Postdoctoral Research Foundation(No.2018ZZ029)
文摘The heterogeneous network with the separation of the control plane and user plane(C/U) is an evolutionary approach to the fifth generation(5 G) to achieve high system coverage and capacity. To minimize signaling load of the core network when there is a macro base station(BS) failure in the control plane, a scheme of transferring the control of small cells under the coverage of the failure macro BS to the neighbor macro BSs is proposed. The average handover rates between small cells related to user mobilities, the extended coverage of the neighboring macro BSs under the constraint of transmitting power and the load balance index of the system are analyzed, based on which the formula of maximizing the handovers processed by macro BSs is constructed and further solved by the convex optimization methods. Simulation results indicate that the proposed scheme can effectively increase the total handovers processed by the macro BSs and thus reduce the signaling load of the core network.