期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Techno-economic analysis of single U-tube and double U-tube heat exchangers in Chongqing area 被引量:1
1
作者 王勇 郭凯生 +3 位作者 田荣 韩传璞 赖道新 徐峰 《Journal of Central South University》 SCIE EI CAS 2009年第S1期244-248,共5页
On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and an... On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and analyzed. The data obtained from test could match with the result deduced from theoretical calculation. From the test results,the cooling capacity of double U-tube is 1.6 times that of single U-tube. Taking cost per depth per watt Clq as the evaluation standard,Clq of single U-tube is 4.69 RMB$/W,and Clq of double U-tube is 3.14 RMB$/W. The double U-tube heat exchangers usage should be prioritized. 展开更多
关键词 ground-source HEAT pump HEAT transfer performance SINGLE u-tubE DOUBLE u-tubE TECHNO-ECONOMIC analysis
下载PDF
An Analytical Model for the Thermal Assessment of a Vertical Double U-Tube Ground-Coupled Heat Pump System in Steady-State Conditions
2
作者 Ali H.Tarrad 《Fluid Dynamics & Materials Processing》 EI 2022年第4期1111-1127,共17页
An analytical model was built to predict the thermal resistance of a vertical double U-tube ground-coupled heat pump that operates under steady-state conditions.It included a geometry obstruction factor for heat trans... An analytical model was built to predict the thermal resistance of a vertical double U-tube ground-coupled heat pump that operates under steady-state conditions.It included a geometry obstruction factor for heat transfer throughout the backfill medium due to the presence of the second loop.The verification of the model was achieved by the implementation of five different borehole configurations and a comparison with other correlations in the available literature.The model considered a U-tube spacing range between(2)and(4)times the U-tube outside diameter producing a geometry configuration factor range of(0.29-0.6).The results of the model were utilized for the assessment of the DX ground heat exchanger coupled heat pump system.For similar geometrical configurations,the borehole thermal resistance experienced a decrease as the geometry factor increased.The single U-tube borehole thermal resistance was higher than that of the double U-tube heat exchanger by(10-27)%for the examined geometry configurations.The borehole thermal resistance at tube spacing of twice the tube diameter was higher than the predicted value at the triple diameter and fell in the range of(18-34)%. 展开更多
关键词 Ground-coupled heat pumps borehole thermal resistance double u-tube MODELING
下载PDF
亨通光电成功研发A-Dry^(TM)全干式光缆及U-Tube^(TM)超细气吹微缆
3
《现代传输》 2015年第3期36-36,共1页
近日,亨通光电成功研发A-Dry^(TM)全干式光缆及U-TubeTM超细气吹微缆,既可满足海外电信市场不同层次的网络建设需求,又可为国内电信市场提供多样化的产品选择,进一步推进公司"从本土企业向国际化企业、从生产型企业向研发生产型企业... 近日,亨通光电成功研发A-Dry^(TM)全干式光缆及U-TubeTM超细气吹微缆,既可满足海外电信市场不同层次的网络建设需求,又可为国内电信市场提供多样化的产品选择,进一步推进公司"从本土企业向国际化企业、从生产型企业向研发生产型企业、从产品供应商向系统集成服务商转型"的战略转型,为实现"打造行业领军企业,加快推进国际化进程"的战略目标提供强力支撑,进一步提升亨通光电在行业中的技术研发领先地位。 展开更多
关键词 亨通光电 A-Dry TM u-tubE 干式 气吹 国内电信市场 国际化企业 生产型企业 产品供应商
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部