NEW PRINCIPLE FOR DIRECTIONAL COMPARISON CARRIER PROTECTION OF EHV TRANSMISSION LINES 被引量:1
1
作者 王钢 李遥 +2 位作者 余晓丹 刘众仆 贺家李 《Transactions of Tianjin University》 EI CAS 1998年第2期6-10,共5页
The increasing scale and complexity of power systems require high performance and high reliability of power system protection.Protective relaying based on directional comparison with power line carrier or microwave ch... The increasing scale and complexity of power systems require high performance and high reliability of power system protection.Protective relaying based on directional comparison with power line carrier or microwave channels is the most suitable protection scheme for long distance EHV transmission lines and is widely used in power systems.The key element of such protection is a directional relay used to discriminate the fault direction.In order to overcome the disadvantages of conventional directional relays,the authors of this paper put forward the directional comparison carrier protection based on the artificial neural network(ANN).The protection is extensively tested using electromagnetic transient program (EMTP) under various electric power system operating and fault conditions.It is proved that the directional comparison carrier protection based on ANN,which can recognize various fault patterns of the protected transmission line(such as fault direction,fault phases etc.)correctly in any kind of operating and fault conditions and the whole process,is satisfactory for EHV transmission line protection. 展开更多
关键词 artificial neural network ehv transmission line directional comparison carrier protection
下载PDF
Overvoltage Suppression for UHV Transmission Lines
2
作者 李永丽 刘太华 +3 位作者 李仲青 景雷 龙英 范建忠 《Transactions of Tianjin University》 EI CAS 2008年第3期222-225,共4页
The overvoltage phenomena of ultra high voltage (UHV) transmission lines are analyzed and verified by EMTDC/PSCAD simulation. Referring to the theoretical analyses and operating experiences of extra high voltage (EHV)... The overvoltage phenomena of ultra high voltage (UHV) transmission lines are analyzed and verified by EMTDC/PSCAD simulation. Referring to the theoretical analyses and operating experiences of extra high voltage (EHV) transmission lines in China and UHV transmission lines in Russia and Japan, the methods to suppress the internal overvoltage in UHV transmission lines by protection and control strategies are discussed. Through the cooperation among the recloser, shunt reactor, tripping and closing resistance, and metal oxide varistor(MOV), the overvoltage can be restrained within an acceptable level. 展开更多
关键词 OVERVOLTAGE RECLOSING relay protection shunt reactors SUPPRESSION uhv transmission lines
下载PDF
Measurement and Simulation of Induced Voltage and Current on 110 KV Crossing Transmission Lines under UHV AC Transmission Lines
3
作者 Weiwei Pan Shoucheng Miu +2 位作者 Guangkai Yu Tian Wu Bo Zhang 《Energy and Power Engineering》 2017年第4期635-643,共9页
The induced electricity of 110 kV transmission lines which cross the UHV AC transmission lines may threaten personal safety of the maintenance staff. In this paper, field measurement of the induced voltage and induced... The induced electricity of 110 kV transmission lines which cross the UHV AC transmission lines may threaten personal safety of the maintenance staff. In this paper, field measurement of the induced voltage and induced current on a 110 kV crossing line inside Jinhua in Zhejiang province is performed. The electrostatic induced voltage on the measured line is 12.24 kV. The power frequency electromagnetic field simulation model is established, and the calculation results are consistent with the measured. Influence factors analysis shows that the electrostatic induced voltage on the 110 kV line is 12.78 kV, the electromagnetic induced voltage is 12.3 V, the induced current through ground wire is less than 1A when the UHV lines operate at full load. The induced voltage and current decrease while the crossing distance increases. Parallel lines induction is much higher than crossing lines. The electromagnetic induced voltage after ground knife-switch shut down would exceed the human safety voltage 36 V while the crossing angle is less than 30?, so the temporary ground wire must be hanged to ensure safety of the maintenance staff. 展开更多
关键词 uhv AC transmission lineS CROSSING INDUCED Voltage INDUCED CURRENT Field MEASUREMENT Simulation Calculation
下载PDF
Effects of Un-transposed UHV Transmission Line on Fault Analysis of Power Systems
4
作者 王安宁 陈青 周占平 《Transactions of Tianjin University》 EI CAS 2008年第3期231-234,共4页
The conventional fault analysis method based on symmetrical components supposes that the three-phase parameters of un-transposed transmission line are symmetrical in case of fault. The errors caused by the method with... The conventional fault analysis method based on symmetrical components supposes that the three-phase parameters of un-transposed transmission line are symmetrical in case of fault. The errors caused by the method with the symmetrical distributed parameter circuit model as the equivalent circuit of the un-transposed ultra high voltage(UHV) transmission line were studied under both normal operation and fault,and the corresponding problems arising were pointed out. By contrast with electromagnetic transient and power electronics(EMTPE) simulation results with the asymmetrical distributed parameter circuit model of un-transposed line, it is shown that the conventional method cannot show the existence of negative and zero sequences before fault happening and there are many errors on voltage and current after fault happening which are different with fault types. The error ranges of voltage and current are 2.13%-81.13% and -7.82%- -86.15%, respectively. 展开更多
关键词 EMTPE fault calculation SIMULATION un-transposed uhv transmission line
下载PDF
Modeling of Lightning Shielding Failure in UHV Transmission Line Based on Randomness Theory
5
作者 FU Jin YANG Qing +2 位作者 SIMA Wen-xia LI Jian-biao XIE Bo 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2542-2546,共5页
The operation data obtained abroad indicates that shielding failure in UHV transmission lines mostly accounts for the tripping-out accidents introduced by lightning striking the transmission line.Based on the discharg... The operation data obtained abroad indicates that shielding failure in UHV transmission lines mostly accounts for the tripping-out accidents introduced by lightning striking the transmission line.Based on the discharge theories of long air gap and randomness theory,a leader progression model of lightning shielding failure is presented in this paper.The random characteristics of the downward and upward leader are simulated in this model.The ground slope angel is also considered in this model by using coordinate transformation.Moreover,the system voltage is also taken into consideration in this model.The simulation results show that the good agreement between this model and the field data.And the results suggest that return striking exist obviously in UHV transmission line. 展开更多
关键词 uhv 随机理论 特高压输电线路 雷电屏蔽 模型
下载PDF
Digital simulation studies on long transmission line protection based on balance of energy
6
作者 文明浩 陈德树 尹项根 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2001年第4期409-411,共3页
The protection based balance of energy is a new technique specially proposed for long transmission lines. This technique depends upon the calculation of net energy into the transmission line by two independent methods... The protection based balance of energy is a new technique specially proposed for long transmission lines. This technique depends upon the calculation of net energy into the transmission line by two independent methods and comparing them to indicate healthy and faulty conditions. In order to study the performance and feasibility of the protection based on balance of energy, the new protection has been extensively tested by using EMTP on a long transmission line with various configurations and operating conditions (including single pole line, double circuit lines and two phase operation). The results calculated by EMTP show that under any condition of a power system, the proposed technique has excellent performance,the viability even for high resistance ground faults and a short operation time. 展开更多
关键词 balance of energy long uhv transmission line transmission line protection digital simulation
下载PDF
Research on the Anti-corona Coating of the Power Transmission Line Conductor
7
作者 Ziqiang Xu Ren Li 《Energy and Power Engineering》 2013年第4期148-150,共3页
An anti-corona method for the power transmission lines is proposed in this paper. The RTV coating is used as the anti-corona coating, which is spaying onto the surface of the wearing conductor. The corona characterist... An anti-corona method for the power transmission lines is proposed in this paper. The RTV coating is used as the anti-corona coating, which is spaying onto the surface of the wearing conductor. The corona characteristic of the conductor test was done, and the corona onset voltage increase after the spraying of the anti-corona layer, the corona loss in the same voltage decrease, which could prove the excellent effect of improving the corona characteristic of the conductor. This anti-corona method will have great prospect, based on the background of the construction of UHV power transmission lines. 展开更多
关键词 CORONA LOSS ehv/uhv Power transmission RTV COATING ANTI-CORONA
下载PDF
基于序电流相位差的EHV/UHV输电线路高阻抗故障选相研究 被引量:1
8
作者 廖东进 卢艳 《机电工程》 CAS 2013年第5期614-618,共5页
为了实现超高压和特高压输电线路的故障快速诊断,将序电流相位差技术应用到输电线路高阻抗故障选相中。开展了三相网络单相接地故障和相间接地故障分析,通过零序和负序电流分量相位差对故障相区间进行了划分,建立了序电流相位差、相阻... 为了实现超高压和特高压输电线路的故障快速诊断,将序电流相位差技术应用到输电线路高阻抗故障选相中。开展了三相网络单相接地故障和相间接地故障分析,通过零序和负序电流分量相位差对故障相区间进行了划分,建立了序电流相位差、相阻抗、相间阻抗、3段距离继电器保护范围与故障类型、故障相别的关系;提出了一种以序电流相位差为判断依据的超高压和特高压输电线路高阻抗故障选相新方法;在500 kV,400 km的输电线路上对该故障选相方案的精确性及可靠性进行了评价,并进行了RTDS仿真测试。研究结果表明:该故障选相方案能够实现精确可靠的识别,并有足够的边际应对意外因素或计算误差,即使在电网振荡时,也可以实现可靠的系统故障相识别。 展开更多
关键词 输电线路 序电流相位差 超高压 特高压 故障选相 故障诊断
下载PDF
Fault component integrated impedance-based pilot protection scheme for EHV/UHV transmission line with thyristor controlled series capacitor(TCSC) and controllable shunt reactor(CSR) 被引量:1
9
作者 HE ShiEn SUONAN JaLe +1 位作者 KANG XiaoNing JIAO ZaiBin 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第2期342-350,共9页
This paper analyzes the fundamental frequency impedance presents a novel transmission line pilot protection scheme characteristic of a thyristor controlled series capacitor (TCSC) and based on fault component integr... This paper analyzes the fundamental frequency impedance presents a novel transmission line pilot protection scheme characteristic of a thyristor controlled series capacitor (TCSC) and based on fault component integrated impedance (FCII) calculated for a transmission line with TCSC and controllable shunt reactor (CSR). The FCII is defined as the ratio of the sum of the fault component voltage phasors of a transmission line with TCSC and CSR to the sum of the fault component current phasors where all the phasors are determined at both line's terminals. It can be used to distinguish internal faults occurring on the line from external ones. If the fault is an external one the FCII reflects the line's capacitive impedance and has large value. If the fault is an internal one on the line the FCII reflects the impedance of the equivalent system and the line and is relatively small. The new pilot protection scheme can be easily set and has the fault phase selection ability and also it is not affected by the capacitive current and the fault transition resistance. It is not sensitive to compensation level and dynamics of TCSC and CSR. The effectiveness of the new scheme is validated against data obtained in ATP simulations and Northwest China 750 kV Project. 展开更多
关键词 ehv/uhv transmission line pilot protection fault component integrated impedance (FCII) thyristor controlled seriescapacitor (TCSC) controllable shunt reactor (CSR)
原文传递
UHV交流输电线路对调幅广播收音台防护间距 被引量:7
10
作者 干喆渊 张小武 +3 位作者 张广洲 万保权 邬雄 周文俊 《高电压技术》 EI CAS CSCD 北大核心 2008年第5期856-861,共6页
为研究特高压交流输电线路对调幅广播收音台的防护间距,通过特高压交流试验基地的实测数据,得到了特高压交流输电线路的无线电干扰水平,为有源干扰的计算提供了强有力的数据支持。利用NEC电磁计算软件,建立了特高压输电线路的实体模型,... 为研究特高压交流输电线路对调幅广播收音台的防护间距,通过特高压交流试验基地的实测数据,得到了特高压交流输电线路的无线电干扰水平,为有源干扰的计算提供了强有力的数据支持。利用NEC电磁计算软件,建立了特高压输电线路的实体模型,计算了无源干扰随频率、入射角度以及防护间距的变化规律,得到了特高压交流线路3种典型塔型的无源干扰水平。最后通过比较有源干扰和无源干扰影响,给出了特高压交流架空输电线路对调幅广播收音台的防护间距计算值。 展开更多
关键词 特高压 交流线路 调幅广播收音台 有源干扰 无源干扰 防护间距
下载PDF
UHVAC输电线路大跨越段的防雷保护 被引量:10
11
作者 葛栋 张翠霞 杜澍春 《高电压技术》 EI CAS CSCD 北大核心 2007年第6期21-24,共4页
为确保特高压输电线路的耐雷可靠性,对晋东南-南阳-荆门UHV输电线路的黄河大跨越段和汉江大跨越段的雷电性能进行了研究并介绍了UHV输电线路大跨越段雷电性能评估的计算方法,同时根据我国输电线路大跨越段的运行情况,参考俄罗斯标准,以... 为确保特高压输电线路的耐雷可靠性,对晋东南-南阳-荆门UHV输电线路的黄河大跨越段和汉江大跨越段的雷电性能进行了研究并介绍了UHV输电线路大跨越段雷电性能评估的计算方法,同时根据我国输电线路大跨越段的运行情况,参考俄罗斯标准,以大跨越段在雷电过电压下的雷击无故障时间(耐雷指标)来确定防雷保护方案,还计算了UHV输电线路大跨越段的年绕击跳闸次数和年反击跳闸次数及雷击避雷线跨越档距中央的反击跳闸次数,提出了按雷电过电压要求的跨越塔塔头间隙。研究表明,我国特高压输电线路大跨越段的耐雷指标不宜<50 a。 展开更多
关键词 特高压 交流输电线路 大跨越 雷电性能 绕击 反击
下载PDF
对AC UHV输电线附近可听噪声预测公式的评估 被引量:19
12
作者 俞集辉 杨越 +2 位作者 何健 杨光 季娟 《高电压技术》 EI CAS CSCD 北大核心 2009年第3期451-456,共6页
特高压输电中,导线的选择是由输电线下的可听噪声大小决定的,所以可听噪声的预测十分重要。为了从不同机构总结出的多种半经验公式中选择最适合用来预测我国特高压交流输电线下可听噪声大小的公式,结合我国对特高压交流输电线的要求,将... 特高压输电中,导线的选择是由输电线下的可听噪声大小决定的,所以可听噪声的预测十分重要。为了从不同机构总结出的多种半经验公式中选择最适合用来预测我国特高压交流输电线下可听噪声大小的公式,结合我国对特高压交流输电线的要求,将相导线水平和正三角排列方式下可听噪声大小的不同预测结果与测量结果进行对比和分析。结果表明:相导线水平排列大雨时可用ENEL公式或IREQ公式计算,小雨时可用ENEL或GE公式计算;相导线正三角排列大雨时可用ENEL公式或BPA公式计算,小雨时只有BPA公式最适合。所以,我国特高压交流输电线下可听噪声的计算在相导线水平排列时选用ENEL公式,相导线正三角方式排列时选用BPA公式。 展开更多
关键词 可听噪声 预测公式 交流输电线 特高压 影响因素对比 相导线水平排列 相导线三角排列
下载PDF
UHV输电线路对中波导航台无线电信号的干扰 被引量:5
13
作者 刘兴发 张小武 +3 位作者 张广洲 邬雄 万保权 尹晖 《电网技术》 EI CSCD 北大核心 2010年第6期27-30,共4页
为分析1000kV特高压输电线路对中波航空导航台的无线电干扰情况,在国家电网特高压交流试验基地进行了飞行试验。利用机载全球卫星定位导航系统(global positioning system,GPS)和地面GPS连续采集直升机穿越特高压线路的飞行数据,采用精... 为分析1000kV特高压输电线路对中波航空导航台的无线电干扰情况,在国家电网特高压交流试验基地进行了飞行试验。利用机载全球卫星定位导航系统(global positioning system,GPS)和地面GPS连续采集直升机穿越特高压线路的飞行数据,采用精密单点定位技术确定飞机航迹,并与理论航迹进行比较。试验结果表明:1000kV特高压线路对中波航空导航台无线电的干扰与飞机距离特高压线路的远近和飞机飞行高度没有明显关系。 展开更多
关键词 特高压输电线路 全球卫星定位导航系统 无线电干扰 精密单点定位技术
下载PDF
直流UHV线路杆塔规划及经济档距的确定 被引量:11
14
作者 李永双 廖宗高 +1 位作者 肖洪伟 段松涛 《高电压技术》 EI CAS CSCD 北大核心 2008年第6期1121-1125,共5页
为降低直流特高压(UHV)输电线路的工程投资,结合±500 kV和国外已建UHV的经验,分析了现有杆塔荷载和经济档距。根据工程实际情况,计算了塔型方案中各塔的摇摆角系数、水平档距、垂直档距、摇摆角角度及塔头间隙等。计算确定,在理想... 为降低直流特高压(UHV)输电线路的工程投资,结合±500 kV和国外已建UHV的经验,分析了现有杆塔荷载和经济档距。根据工程实际情况,计算了塔型方案中各塔的摇摆角系数、水平档距、垂直档距、摇摆角角度及塔头间隙等。计算确定,在理想平地情况下的经济塔高为51 m、经济档距为510 m。研究结果已被应用于云广±800kV线路。 展开更多
关键词 特高压直流 输电线路 杆塔荷载规划 经济档距 经济塔高 优化排位 工程投资
下载PDF
基于暂态电流信号的EHV输电线路保护新方案
15
作者 谭书平 杨明玉 张举 《现代电力》 2006年第6期21-24,共4页
提出了一种基于单端电流暂态信号小波变换的超高压输电线路快速保护方案。利用单端暂态电流信号的小波变换模极大值,对电流信号的李氏指数进行最小二乘法估计,来判断故障线路。通过大量ATP仿真证明,在各种故障情况下该保护算法能准确、... 提出了一种基于单端电流暂态信号小波变换的超高压输电线路快速保护方案。利用单端暂态电流信号的小波变换模极大值,对电流信号的李氏指数进行最小二乘法估计,来判断故障线路。通过大量ATP仿真证明,在各种故障情况下该保护算法能准确、可靠地动作。 展开更多
关键词 ehv输电线路 暂态电流 小波变换 李氏指数
下载PDF
UHV输电线路中绝缘子串电位分布的仿真计算 被引量:2
16
作者 李庆 邓发玉 《电子科技》 2010年第2期29-32,48,共5页
利用三维电磁场分析软件Ansoft对铁塔、导线、绝缘子按实际尺寸建立三维模型。综合考虑了芯棒、伞群、球头球窝、导线、连接金具、铁塔、均压环等因素对1000kV特高压输电线路中的绝缘子表面电场分布进行了计算。分析了导线、连接金具、... 利用三维电磁场分析软件Ansoft对铁塔、导线、绝缘子按实际尺寸建立三维模型。综合考虑了芯棒、伞群、球头球窝、导线、连接金具、铁塔、均压环等因素对1000kV特高压输电线路中的绝缘子表面电场分布进行了计算。分析了导线、连接金具、均压环、铁塔、三相中其余两相对Ⅰ型绝缘子串和V型绝缘子串电场分布的影响。计算结果可以为绝缘子的正确使用和优化设计提供参考。分析可知,使用均压环可使绝缘子上的电位分布有较大地改善。 展开更多
关键词 特高压输电线路 铁塔 导线 三相 绝缘子串 电位分布 有限元法 均压环
下载PDF
A review of single phase adaptive auto-reclosing schemes for EHV transmission lines 被引量:12
17
作者 Waqar Ahmad Khan Tianshu Bi Ke Jia 《Protection and Control of Modern Power Systems》 2019年第1期217-226,共10页
Statistics shows that transients produced by lightning or momentary links with external objects, have produced more than 80% of faults in overhead lines. Reclosing of circuit breaker (CB) after a pre-defined dead time... Statistics shows that transients produced by lightning or momentary links with external objects, have produced more than 80% of faults in overhead lines. Reclosing of circuit breaker (CB) after a pre-defined dead time is very common however reclosing onto permanent faults may damage the power system stability and aggravate severe damage to the system. Thus, adaptive single-phase auto-reclosing (ASPAR) based on investigating existing electrical signals has fascinated engineers and researchers. An ASPAR blocks CB reclosing onto permanent faults and allows reclosing permission once secondary arc is quenched. To address the subject, there have been many ASPARs techniques proposed based on the features trapped in a faulty phase. This paper presents a critical survey of adaptive auto-reclosing schemes that have hitherto been applied to EHV transmission lines. 展开更多
关键词 Adaptive auto-reclosing PROTECTION ehv transmission lines Temporary faults Permanent faults
原文传递
Statistical Analysis of Radio Interference of 1000 kV UHV AC Double-circuit Transmission Lines in Foul Weather 被引量:2
18
作者 Huichun Xie Xiang Cui +1 位作者 Baoquan Wan Jiangong Zhang 《CSEE Journal of Power and Energy Systems》 SCIE 2016年第2期47-55,共9页
Analyzing the impact of radio interference(RI)variation during foul weather conditions is an area that has received limited study.This paper provides a statistical analysis of RI measurements obtained from a long-term... Analyzing the impact of radio interference(RI)variation during foul weather conditions is an area that has received limited study.This paper provides a statistical analysis of RI measurements obtained from a long-term observation station close to the world’s first commercially operating 1000 kV UHV AC double-circuit transmission line in China.During six months of observations,the impact of RI was studied on the line during fog,drizzle,and light snow and rain.It was found that RI increases linearly with the natural logarithm of the precipitation intensity.The Levenberg-Marquardt algorithm(LMA)is employed to fit the RI value with the precipitation intensity.The reasonable distribution of RI in different foul weather is verified by one-sample K-S test.This test is seen as beneficial for further RI prediction based on statistical weather mode. 展开更多
关键词 1000 kV uhv AC double-circuit transmission line foul weather precipitation intensity radio interference statistical analysis
原文传递
Effect of Different Arresters on Switching Overvoltages in UHV Transmission Lines
19
作者 杨鹏程 陈水明 何金良 《Tsinghua Science and Technology》 SCIE EI CAS 2010年第3期325-328,共4页
The amplitude of switching overvoltages is a key factor for designing the insulation of UHV equipment. The effect of different arresters needs to be studied, since installing arresters is an important way to suppress ... The amplitude of switching overvoltages is a key factor for designing the insulation of UHV equipment. The effect of different arresters needs to be studied, since installing arresters is an important way to suppress switching overvoltages in UHV transmission lines. Switching overvoltages on the 1000 kV Huainan-Huxi double-circuit transmission line were simulated for different operating modes and different arrester designs using the electromagnetic transient program PSCAD/EMTDC. With parallel resistors, the switching overvoltages are less than 1.70 p.u. (1.0 p.u.=1100×√ 2 /√3 kV). If the arrestors are better, the switching overvoltages can be reduced even lower to 1.55 p.u. Without parallel resistors, the arresters can reduce three-phase energizing overvoltages to 1.70 p.u, while the single-phase reclosing overvoltages still exceed the limit. The results show that the parallel resistors cannot be eliminated if the arresters are only installed at each end of the transmission line. Also, better quality arresters significantly lower the switching overvoltages. 展开更多
关键词 uhv double-circuit transmission line switching overvoltages ARRESTERS
原文传递
UHV交流输电线路有源干扰下无方向信标台功率限值的分析
20
作者 周铖路 翁木云 陈凤 《智能电网》 2015年第1期28-32,共5页
有关UHV交流输电线路与无方向信标台电磁兼容方面的研究主要集中在防护距离的分析,对间距无法满足要求时的兼容问题研究较少。为此,从台站频谱参数入手,分析特高压交流输电线路有源干扰下无方向信标台的发射功率限值。首先介绍无方向信... 有关UHV交流输电线路与无方向信标台电磁兼容方面的研究主要集中在防护距离的分析,对间距无法满足要求时的兼容问题研究较少。为此,从台站频谱参数入手,分析特高压交流输电线路有源干扰下无方向信标台的发射功率限值。首先介绍无方向信标台的工作原理及配置区域,然后分析UHV交流输电线路对台站的干扰机理,最后根据飞行航迹,以防护率为干扰判别依据,结合防护距离的研究,分别针对航路无方向信标台、近距无方向信标台和远距无方向信标台进行有效辐射功率的分析。结果表明,在给定条件下,对于航路和远距无方向信标台,有效辐射功率分别大于5.298 W、5.273 W时,机载无线电罗盘不受干扰;对于近距无方向信标台,与输电线路始终满足兼容的要求,无需分析限值。 展开更多
关键词 特高压输电线路 无方向信标台 防护率 有效辐射功率 发射功率限值