The ultraviolet-visible light spectrophotometer method was adopted to determine thioglucoside in cabbage with the seeds.Individual plant of cabbage was used as test materials,palladium chloride as complexing agent and...The ultraviolet-visible light spectrophotometer method was adopted to determine thioglucoside in cabbage with the seeds.Individual plant of cabbage was used as test materials,palladium chloride as complexing agent and sodium cellulose glycolate as dispersing agent.The results showed that palladiumd thioglucoside method could be taken as a quick,easy and precise quantitative analysis method to determine thioglucoside in cabbage.展开更多
Background: The sunglass standards are not strictly implemented in many countries except Aus-tralia. The purpose of the study was to evaluate the optical properties of unbranded sunglasses for light transmittance. Met...Background: The sunglass standards are not strictly implemented in many countries except Aus-tralia. The purpose of the study was to evaluate the optical properties of unbranded sunglasses for light transmittance. Methods: Unbranded sunglasses with no information about their specifications were included. They were allocated to two groups based on their prices;the ones > 25 US$ (Group A) and the cheaper ones (Group B). Their transmittance spectrum was measured between 190 nm and 900 nm using a double beam scanning spectrophotometer. The European standard for sunglasses was used to evaluate their compliance regarding ultraviolet radiation (UVR) transmittance and minimum requirement for wearing when driving. Results: Thirty-eight sunglasses (Group A = 20 and Group B = 18) were evaluated. Four sunglasses in each group were non-compliant. Percentage transmittance of visible light was <8% in five sunglasses of Group A and in three of Group B, so these were not appropriate to wear when driving. Totally six sunglasses of Group A and five of Group B were non-compliant and/or inappropriate to wear when driving. Conclusions: Based on our findings about their UVR protection and visible light transmittance %, eye care professionals must warn people against the use of unbranded sunglasses without any information about their specifications.展开更多
Determination palladiums have been reported 5% (w/w) Pd/BaSO4 known as Rosenmund Catalyst. The determination of palladium II known as Rosenmund Catalyst is always an expensive procedure usually involving procedures su...Determination palladiums have been reported 5% (w/w) Pd/BaSO4 known as Rosenmund Catalyst. The determination of palladium II known as Rosenmund Catalyst is always an expensive procedure usually involving procedures such as flame atomic absorption spectrophotometry, emission spectrometry, and many spectrophotometric methods. In this study, palladium II in 5% Pd/BaSO4, was synthesized and employed to develop an extractive UV-Visible Spectrophotometric, and an inductively coupled plasma mass spectrometry ICP/MS methods for the determination of palladium II. Specification for Pd is 4.85% to 5.10%;the result was 4.97% for the UV-Visible spectrophotometer and 4.90% for the ICP/MS. Both results meet the requirements.展开更多
文摘The ultraviolet-visible light spectrophotometer method was adopted to determine thioglucoside in cabbage with the seeds.Individual plant of cabbage was used as test materials,palladium chloride as complexing agent and sodium cellulose glycolate as dispersing agent.The results showed that palladiumd thioglucoside method could be taken as a quick,easy and precise quantitative analysis method to determine thioglucoside in cabbage.
文摘Background: The sunglass standards are not strictly implemented in many countries except Aus-tralia. The purpose of the study was to evaluate the optical properties of unbranded sunglasses for light transmittance. Methods: Unbranded sunglasses with no information about their specifications were included. They were allocated to two groups based on their prices;the ones > 25 US$ (Group A) and the cheaper ones (Group B). Their transmittance spectrum was measured between 190 nm and 900 nm using a double beam scanning spectrophotometer. The European standard for sunglasses was used to evaluate their compliance regarding ultraviolet radiation (UVR) transmittance and minimum requirement for wearing when driving. Results: Thirty-eight sunglasses (Group A = 20 and Group B = 18) were evaluated. Four sunglasses in each group were non-compliant. Percentage transmittance of visible light was <8% in five sunglasses of Group A and in three of Group B, so these were not appropriate to wear when driving. Totally six sunglasses of Group A and five of Group B were non-compliant and/or inappropriate to wear when driving. Conclusions: Based on our findings about their UVR protection and visible light transmittance %, eye care professionals must warn people against the use of unbranded sunglasses without any information about their specifications.
文摘Determination palladiums have been reported 5% (w/w) Pd/BaSO4 known as Rosenmund Catalyst. The determination of palladium II known as Rosenmund Catalyst is always an expensive procedure usually involving procedures such as flame atomic absorption spectrophotometry, emission spectrometry, and many spectrophotometric methods. In this study, palladium II in 5% Pd/BaSO4, was synthesized and employed to develop an extractive UV-Visible Spectrophotometric, and an inductively coupled plasma mass spectrometry ICP/MS methods for the determination of palladium II. Specification for Pd is 4.85% to 5.10%;the result was 4.97% for the UV-Visible spectrophotometer and 4.90% for the ICP/MS. Both results meet the requirements.