期刊文献+
共找到2,470篇文章
< 1 2 124 >
每页显示 20 50 100
Application of Total Error Strategy in Validation of Affordable and Accessible UV-Visible Spectrophotometric Methods for Quality Control of Poor Medicines 被引量:1
1
作者 Jérémie Kindenge Mbinze Jean Nsangu Mpasi +8 位作者 Elza Maghe Sébastien Kobo Rodrigue Mwanda Guy Mulumba Jacquie Bolavie Bolande Trésor Menanzambi Bayebila Maguy Borive Amani Philippe Hubert Roland Djang’eing’a Marini 《American Journal of Analytical Chemistry》 2015年第2期106-117,共12页
In the framework of fighting against the poor quality medicines sold in developing countries using classical analytical methods easily accessible in those countries, four UV-Visible spectrophotometric methods for one ... In the framework of fighting against the poor quality medicines sold in developing countries using classical analytical methods easily accessible in those countries, four UV-Visible spectrophotometric methods for one antimalarial (quinine) and two antibiotics (amoxicillin and metronidazole) have been developed and validated according to the total error strategy using the accuracy profiles as a decision tool. The dosing range was 2 - 10 μg/mL (for quinine sulfate in tablet), 4 - 12 μg/mL (for quinine bichlorhydrate in oral drop-metronidazole benzaote in oral suspension) and 15 - 35 μg/mL (for amoxicillin trihydrate in capsule). The validated methods were then applied in determining the content of some analogous medicines sold in the Democratic Republic of Congo. Thus, the proposed UV-Visible spectrophotometric methods are simple and suitable to quantify quinine, amoxicillin and metronidazole in different pharmaceutical forms. 展开更多
关键词 POOR Quality MEDICINES uv-visible spectrophotometric Methods QUININE Amoxicillin METRONIDAZOLE VALIDATION Total Error Accuracy Profiles
下载PDF
Determination of Palladium II in 5% Pd/BaSO<sub>4</sub>by ICP-MS with Microwave Digestion, and UV-VIS Spectrophotometer
2
作者 Y. Yildiz M. Kotb +3 位作者 A. Hussein M. Sayedahmed M. Rachid M. Cheema 《American Journal of Analytical Chemistry》 2019年第4期127-136,共10页
Determination palladiums have been reported 5% (w/w) Pd/BaSO4 known as Rosenmund Catalyst. The determination of palladium II known as Rosenmund Catalyst is always an expensive procedure usually involving procedures su... Determination palladiums have been reported 5% (w/w) Pd/BaSO4 known as Rosenmund Catalyst. The determination of palladium II known as Rosenmund Catalyst is always an expensive procedure usually involving procedures such as flame atomic absorption spectrophotometry, emission spectrometry, and many spectrophotometric methods. In this study, palladium II in 5% Pd/BaSO4, was synthesized and employed to develop an extractive UV-Visible Spectrophotometric, and an inductively coupled plasma mass spectrometry ICP/MS methods for the determination of palladium II. Specification for Pd is 4.85% to 5.10%;the result was 4.97% for the UV-Visible spectrophotometer and 4.90% for the ICP/MS. Both results meet the requirements. 展开更多
关键词 PALLADIUM DETERMINATION 5% PALLADIUM Barium Sulfate Inductively Coupled Plasma Mass Spectrometry uv-visible spectrophotometer Microwave Digestion
下载PDF
Spectrophotometer standardization in UV-Vis spectral region
3
作者 Alaa-Eldin A Abd-Elmageed Essam M Elmoghazy Fatma Elsharkawy 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2016年第1期40-43,共4页
Ultraviolet-visible(UV-Vis)spectrophotometry is commonly used in analytical laboratories for qualitative and quantitative analyses.To make the data obtained reliable,an experimental instrument must be calibrated.Nat... Ultraviolet-visible(UV-Vis)spectrophotometry is commonly used in analytical laboratories for qualitative and quantitative analyses.To make the data obtained reliable,an experimental instrument must be calibrated.National Institute for Standards(NIS)in Egypt builds up aphotometric method to ensure the competence of absorbance and transmittance to the standard international and national requirements.This paper presents an instrument for UV-Vis measurement,discusses the factors affecting measurement reliability and estabishes the uncertainty model including correspoding measurement parameters. 展开更多
关键词 spectrophotometer STANDARDIZATION ABSORBANCE UNCERTAINTY
下载PDF
Study on superoxide and hydroxyl radicals generated in indirect electrochemical oxidation by chemiluminescence and UV-Visible spectra 被引量:3
4
作者 ZHANG, Bo-Tao ZHAO, Li-Xia LIN, Jin-Ming 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2008年第8期1006-1011,共6页
The generation and transformation of radicals on the cathode of indirect electrochemical oxidation were studied by chemilumines- cence(CL)and UV-Visible spectra in the reactor with a salt bridge that connected the sep... The generation and transformation of radicals on the cathode of indirect electrochemical oxidation were studied by chemilumines- cence(CL)and UV-Visible spectra in the reactor with a salt bridge that connected the separated chambers.The CL intensity of 4×10^(-9)mol/L luminol on the cathode with bubbling oxygen was about seven times that of the intensity without it,which was because of the generation of reactive oxygen species(ROS).The existence of ROS,especially the generation of the superoxide radical,coul... 展开更多
关键词 chemiluminescence(CL) uv-visible RADICAL indirect electrochemical oxidation
下载PDF
Characterization on the Exfoliation Degree of Graphite Oxide into Graphene Oxide by UV-visible Spectroscopy 被引量:3
5
作者 艾凡荣 ZHONG Yu +1 位作者 HU Xiaowu YAN Xiluan 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2016年第3期515-518,共4页
The exfoliation degree of graphite oxide into graphene oxide plays an important role in the massive production method of reduced graphene oxide. It is significant to find a simple and feasible method to analyze the ex... The exfoliation degree of graphite oxide into graphene oxide plays an important role in the massive production method of reduced graphene oxide. It is significant to find a simple and feasible method to analyze the exfoliation degree of graphite oxide. In the present work, graphite oxide was synthesized by a modified Hummers method, and then graphene oxide colloids were obtained by exfoliation of graphite oxide dispersed in de-ionized water. UV-visible spectroscopy was used to characterize the absorption of the graphene oxide colloids, and the concentration of graphene oxide colloids indicated by absorption area of UV-visible spectra was studied. Results show that there is a relatively stable relationship between them, indicating that UV- visible spectroscopy is a potential method for analyzing the exfoliation degree of graphite oxide into graphene oxide. 展开更多
关键词 GRAPHENE graphene oxide graphene oxide colloids uv-visible spectroscopy
下载PDF
Assessment of Long Term UV Radiation Measured by the Brewer Spectrophotometer in Hong Kong during 1995-2005 被引量:2
6
作者 T.J. Wang K.S. Lam +1 位作者 Q. Liu X.M. Wang 《Atmospheric and Climate Sciences》 2011年第1期9-17,共9页
Time series of daily UV radiation measured by the ground-based Brewer spectrophotometer #115 in Hong Kong during 1995-2005 were studied through statistics analysis, with focus on the variability and long term changes ... Time series of daily UV radiation measured by the ground-based Brewer spectrophotometer #115 in Hong Kong during 1995-2005 were studied through statistics analysis, with focus on the variability and long term changes in relation to total ozone, clouds and AOD (Aerosol Optical Depth). The 11-year mean UV daily dose is 2644±262 J/m2, with maxima(3311 J/m2) in 2000 and minima (2415 J/m2) in 2002. The data were compared with that from TOMS (Total Ozone Mapping Spectrometer) Version 8 and show general agreement between the two. However, the Brewer UV measurement is about 10% lower compared to TOMS data. Apart from the common-known strong seasonal cycle, 26 month periodical was resolved by use of wavelet analysis, which was believed to be associated with quasi-biennial oscillation (QBO) of general circulation. In cloudy days, the annual mean UV daily dose decrease 3.5% to 44.5% compared to clear days. It was also found that surface UV irradiance has close relation to air pollution. Under clear sky condition, 1% AOD increase will lead to 0.2% UV decrease. While global UV radiation increase due to the worldwide observed ozone depletion, investigations indicate that this trend is not significant in Hong Kong during the last 11 years. The possible causes can be attributed to the compensative effect from two aspects. One is the increase of UV resulting from the reduction of clouds with rate of 0.56/10 yr. The other is the decrease of UV due to the enhancement of total ozone and AOD with a rate of 4.23 DU/10 yr and 0.33/10 yr, respectively. 展开更多
关键词 UV RADIATION Brewer spectrophotometer TOMS Hong Kong
下载PDF
Sensitivity Enhancement in Uranium Determination by UV-Visible Spectroscopy Using Ion Imprinted Polymer 被引量:2
7
作者 Tulin BICIM Mehmet YAMAN 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2016年第6期1992-1997,共6页
There is need to determination of uranium concentration at ppb level in environmental matrices.Due to low sensitivity of FAAS,UV-Visible Spectroscopy is generally used as measurement technique.In this study,ion-imprin... There is need to determination of uranium concentration at ppb level in environmental matrices.Due to low sensitivity of FAAS,UV-Visible Spectroscopy is generally used as measurement technique.In this study,ion-imprinted polymers(IIP)were prepared for uranyl ion(imprint ion)by formation of ternary(salicylaldoxime and 4-vinylpyridine)complex in 2-methoxy ethanol(porogen)following copolymerization with methacrylic acid(MAA)as a functional monomer and ethylene glycol dimethacrylate(EGDMA)as crosslinking monomer using 2,2-azobisisobutyronitrile as initiator.The synthesized polymers were characterized by FTIR and TGA analysis.ArsenazoⅢin 3M HClO_4 was used as complexing agent in the measurement step.The optimal pH for preconcentration was found to be between 3.5~6.5values.The developed method was applied to uranium(Ⅵ)determination in natural water samples. 展开更多
关键词 URANIUM Ion imprinted polymer ArsenazoⅢ uv-vis Spectroscopy
下载PDF
Contacted Ion Pairs in Aqueous CuCl2 by the Combination of Ratio Spectra, Difference Spectra, Second Order Difference Spectra in the UV-Visible Spectra
8
作者 鞠思文 张宁 +4 位作者 王志强 张睿挺 曾德文 邵晓鹏 林珂 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2017年第6期657-663,I0001,I0002,共9页
The microstructure of aqueous CuCl2 has been studied through lots of technologies for many years; however, it remains a controversial subject. In this study, a new spectroscopic method has been proposed to analyze the... The microstructure of aqueous CuCl2 has been studied through lots of technologies for many years; however, it remains a controversial subject. In this study, a new spectroscopic method has been proposed to analyze the UV-visible spectra of thin fihn of CuCl2/H2O solutions at different concentrations. This method is the combination of ratio spectra, difference spectra and second order difference spectra. By using this method, two new bands at -230 and -380 nm are obviously observed. The bands are assigned as the contacted ion pairs [CuCl3(H2O)n]- or [CuCl4(H2O)n]2-, which demonstrates that ion pairs exist in the CuCl2/H2O solution. Such finding agrees with the recent theoretical spectra obtained by time-dependent density functional theory. Furthermore, the populations of the contacted ion pairs are discussed. This study not only offers the direct spectroscopic evidence of [CuCl3(H2O)n]- or [CuCl4(H2O)n]2- in aqueous CuCl2, but also suggests that the spec- troscopic analysis method is powerful to extract the weak bands in a strong overlapping spectrum. 展开更多
关键词 uv-visible spectroscopy Ratio spectra Difference spectra CuCl2/H2O solution Ion pair
下载PDF
A Novel Chip-based Spectrophotometer for Online Detection
9
作者 Haoyuan Cai Min-Hsien Wu Zheng Cui 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期346-348,共3页
A chip-based spectrophotometer integrated with optical fiber is successfully demonstrated.Grade concentration of lactate solution flowed through the chip to perform an online detection.The response time (100s)and Limi... A chip-based spectrophotometer integrated with optical fiber is successfully demonstrated.Grade concentration of lactate solution flowed through the chip to perform an online detection.The response time (100s)and Limit of Detection (LOD, 50mg/L)of the device were measured.This device shows comparable performance with traditional commercial instrument, while greatly decreases the sample requirement per detection and reduces the size of total system,introducing a novel method for real-time detection. 展开更多
关键词 spectrophotometer optical fiber online detection
下载PDF
THE LIGNIN CONTENT IN BLACK LIQUID OF STRAW AS-AQ BY ULTRAVIOLET SPECTROPHOTOMETER 被引量:1
10
作者 HaiqiangShi BingyueLiu +2 位作者 XingqiangLi LongquanXu BeihaiHe 《天津科技大学学报》 CAS 2004年第A02期91-96,共6页
The measurement of lignin content in black liquid of straw AS-AQ by ultraviolet spectrophotometer(UV) is discussed in this paper. Different dilution multiple and contrast solutions have an effect on the measured resul... The measurement of lignin content in black liquid of straw AS-AQ by ultraviolet spectrophotometer(UV) is discussed in this paper. Different dilution multiple and contrast solutions have an effect on the measured results of the lignin content by UV. The calculation method for the absorption coefficient and the scanning spectrum property of liquor acidified by SO2 are introduced in this paper. 展开更多
关键词 紫外分光光度法 木质素 黑液 秸杆制浆液 多体稀释
下载PDF
Determination of Thioglucoside in Cabbage by Using the Ultraviolet-visible Light Spectrophotometer
11
作者 WANGJing WANGQing 《Journal of Northeast Agricultural University(English Edition)》 CAS 2000年第2期149-157,共9页
The ultraviolet-visible light spectrophotometer method was adopted to determine thioglucoside in cabbage with the seeds.Individual plant of cabbage was used as test materials,palladium chloride as complexing agent and... The ultraviolet-visible light spectrophotometer method was adopted to determine thioglucoside in cabbage with the seeds.Individual plant of cabbage was used as test materials,palladium chloride as complexing agent and sodium cellulose glycolate as dispersing agent.The results showed that palladiumd thioglucoside method could be taken as a quick,easy and precise quantitative analysis method to determine thioglucoside in cabbage. 展开更多
关键词 Ultraviolet visible light spectrophotometer method CABBAGE thioglucoside determination method
下载PDF
Transmittance Spectrum of Unbranded Sunglasses Using Spectrophotometer
12
作者 Huseyin Gursoy Hikmet Basmak +1 位作者 Hamza Esen Ferhan Esen 《Open Journal of Ophthalmology》 2015年第1期1-5,共5页
Background: The sunglass standards are not strictly implemented in many countries except Aus-tralia. The purpose of the study was to evaluate the optical properties of unbranded sunglasses for light transmittance. Met... Background: The sunglass standards are not strictly implemented in many countries except Aus-tralia. The purpose of the study was to evaluate the optical properties of unbranded sunglasses for light transmittance. Methods: Unbranded sunglasses with no information about their specifications were included. They were allocated to two groups based on their prices;the ones > 25 US$ (Group A) and the cheaper ones (Group B). Their transmittance spectrum was measured between 190 nm and 900 nm using a double beam scanning spectrophotometer. The European standard for sunglasses was used to evaluate their compliance regarding ultraviolet radiation (UVR) transmittance and minimum requirement for wearing when driving. Results: Thirty-eight sunglasses (Group A = 20 and Group B = 18) were evaluated. Four sunglasses in each group were non-compliant. Percentage transmittance of visible light was <8% in five sunglasses of Group A and in three of Group B, so these were not appropriate to wear when driving. Totally six sunglasses of Group A and five of Group B were non-compliant and/or inappropriate to wear when driving. Conclusions: Based on our findings about their UVR protection and visible light transmittance %, eye care professionals must warn people against the use of unbranded sunglasses without any information about their specifications. 展开更多
关键词 Sunglass spectrophotometer TRANSMITTANCE SPECTRUM ULTRAVIOLET Radiation VISIBLE Light
下载PDF
The Effectiveness of a Portable Fluorescence Spectrophotometer for Early Detection of Oral Cancer
13
作者 Katsuhiro Asaka Akira Fukatsu Chiaki Komine 《Open Journal of Stomatology》 2022年第1期30-31,共12页
<strong>Purpose:</strong> To investigate whether photodynamic diagnosis (PDD) using a portable fluorescence spectrophotometer (FC-1) can easily and objectively discriminate between normal and tumor cells a... <strong>Purpose:</strong> To investigate whether photodynamic diagnosis (PDD) using a portable fluorescence spectrophotometer (FC-1) can easily and objectively discriminate between normal and tumor cells at the dental chairside, and to further compare it with PDD that requires speculum examination by focusing on protoporphyrin IX (PPIX). <strong>Methods: </strong>Three cell lines (2 human oral squamous cell carcinoma-derived cell lines, HSC-2 and HSC-3 cells, and oral keratinocytes, HOK cells) were cultured. 5-Aminolevulinic acid hydrochloride (5-ALA) and deferoxamine mesylate (DFO) were mixed in DMEM, and the mixture was set to Control (DMEM only) and PDD (5-ALA+DFO) groups. And then, a fluorescence was measured under room temperature (RT) and 37&deg;C (Incubation) by using FC-1. In this study, the two conditions were combined with the Control and PDD groups to form the Control/RT, Control/Incubate, PDD/RT, and PDD/Incubate groups. Additionally, the amount of singlet oxygen (1O2) generated by irradiation with 405 nm LED was measured using electron spin resonance spectroscopy to detect PPIX in the cell supernatant after 24 hours. <strong>Results:</strong> In HSC-2 and HSC-3, the fluorescence intensity values increased significantly at 2 hours between the Control/RT and PDD/RT groups. In addition, there was a significant difference between HSC-2 and HSC-3 compared to HOK. In all cell lines, the fluorescence intensity values of the PDD/Incubate group were significantly higher than those of the PDD/Control group. The amount of <sup>1</sup>O<sub>2</sub> generated by 405 nm LED irradiation was higher in the cell supernatants of all cell lines in the order of Control/RT < Control/Incubate < PDD/RT < PDD/Incubate group, and HSC-3 in the PDD/Incubate group showed a significant increase compared to HOK. <strong>Conclusion: </strong>It is suggested that PDD using FC-1 can clearly distinguish between normal cells and tumor cells in vitro studies using cell lines at 2 hours under 37&deg;C, and it can detect not only intracellular PPIX, but also extracellular PPIX. 展开更多
关键词 Photodynamic Diagnosis Portable Fluorescence spectrophotometer Oral Cancer Protoporphyrin IX
下载PDF
Hyper Gravity-Induced Transients in <i>Phycomyces</i>as Measured by Single Beam Spectrophotometer on the Sounding Rocket TEXUS 50
14
作者 Werner Schmidt 《Journal of Modern Physics》 2018年第2期273-286,共14页
In the first paper of two referring to the TEXUS 50 campaign using micro dual wavelength spectrometers (MDWS) we kinetically determined the threshold1 for GIACs (gravity-induced absorption changes) in Phycomyces to be... In the first paper of two referring to the TEXUS 50 campaign using micro dual wavelength spectrometers (MDWS) we kinetically determined the threshold1 for GIACs (gravity-induced absorption changes) in Phycomyces to be lower than 25 × 10&minus;3 g (http://file.scirp.org/pdf/JMP_2015082810060783.pdf). In this second paper, we attended measurement of GIAC-spectra. Unexpectedly, during the upwards movement, i.e. the hypergravity phase up to top acceleration values reaching 11.6 g at 35.4 s after liftoff we observed transient GIAC-spectra ranging from 380 to 750 nm. In addition, during the whole acceleration phase of 68.2 s, another component near 700 nm develops which remains stable during the whole “free fall trajectory parabola” for 381.3 s. The subsequent reentry of the rocket leads to extraordinary deceleration values up 37.8 g, completely destroying Phycomyces sporangiophores excluding their spectral measurement. During the microgravity phase and by centrifuge operation we were unable to detect any GIAC-spectra (in contrast to kinetic MDWS-measurements, first paper). 展开更多
关键词 MDWS (Micro-Dual Wavelength spectrophotometer) Single Beam spectrophotometer (SBS) Diode Array Spectrometer (USB-2000+ Ocean Optics) GIAC (Gravity-Induced Absorption Change) PHYCOMYCES blakesleeanus Sporangiophore Micro- and Hypergravity Texus 50 Sounding Rocket Graviperception. HYPER Gravity-Induced Transients
下载PDF
Interaction between DNA with Complex of Eu^(3+)-Rutin by UV-Visible Spectroscopy and Electrochemistry
15
作者 Kang Jingwan Wu Haixia Zhuo Ling Zeng Hongjuan Lu Xiaoquan 《Journal of Rare Earths》 SCIE EI CAS CSCD 2005年第4期I0009-I0009,共1页
The interaction of Eu^3+-rutin with CT DNA was studied by UV-visible spectroscopy and electrochemistry. All experimental results indicate that the complex binds to DNA by the electrostatic mode and the groove binding... The interaction of Eu^3+-rutin with CT DNA was studied by UV-visible spectroscopy and electrochemistry. All experimental results indicate that the complex binds to DNA by the electrostatic mode and the groove binding mode. Information such as intrinsic binding costant ( k = 1. 426 × 104 mol·L^-1 ), and binding numbers ( n = 2), were determined by cyclic vohammetry and differential pulse vohammetry at glass carbon electrode. Interaction between Eu^3+ with rutin was also studied by UV-visible spectroscopy. 展开更多
关键词 Eu^3 +-rutin complex CTDNA ELECTROCHEMISTRY uv-visible spectroscopy rare earths
下载PDF
Estimating Aluminum Leaching into Meat Baked with Aluminum Foil Using Gravimetric and UV-Vis Spectrophotometric Method
16
作者 Layla A. Al Juhaiman 《Food and Nutrition Sciences》 2015年第5期538-545,共8页
Baking meat by wrapping them in Aluminum (Al) foil is common in many countries. The excessive use of Al foil in baking and the disagreement about using Al foils were the motivation to do this study especially after th... Baking meat by wrapping them in Aluminum (Al) foil is common in many countries. The excessive use of Al foil in baking and the disagreement about using Al foils were the motivation to do this study especially after the 2007 WHO/FDA Report. In this investigation, a gravimetric and a UV-Vis spectrophotometric method are used to estimate Aluminum (Al) leaching into meat baked by wrapping in Al foil. Three kinds of meat were used fish, cow stakes and chicken. The importance of Al exposure area was neglected by many studies. Five factors affecting Al leaching into meat are studied (baking temperature, baking time, additives, Al exposure area and weight of meat). The effect of cooking times (20, 40, 60 minutes) at 180℃ and cooking temperatures (160℃, 180℃, 200℃) at 60 minutes on the amount of Al leaching were evaluated. It was found that Al leaching into meat increased with increasing temperature, baking time, additives and Al exposure area. Moreover, Al exposure area was more effective than the weight of the meat. The Al leaching was highest in fish and lowest in chicken. Comparing the present results with the Provisional Tolerance Weekly Intake of Al approved by WHO/FDA, it shows that Al leaching into meat baked by wrapping in Al foil may add considerable doses into the diet. Continuous monitoring of Al foil used for baking meat is recommended. 展开更多
关键词 AL FOIL AL LEACHING into MEAT Weight Loss uv-vis Method Provisional Tolerable WEEKLY Intake
下载PDF
Determination of the Biodiesel Content in Petrodiesel/Biodiesel Blends: A Method Based on Uv-Visible Spectroscopy and Chemometrics Tools
17
作者 Armando Guerrero Francisco Anguebes +4 位作者 Mepivoseth Castelán Victorino Morales Ismael León José C. Zavala Atl V. Córdova 《American Journal of Analytical Chemistry》 2013年第6期273-276,共4页
In this work, we developed an analytical method based on UV-visible spectroscopy to determine the concentration of biodiesel from African palm in blends of petrodiesel. Seventy-five samples with biodiesel concentratio... In this work, we developed an analytical method based on UV-visible spectroscopy to determine the concentration of biodiesel from African palm in blends of petrodiesel. Seventy-five samples with biodiesel concentrations between 0-100 wt% were prepared. The spectral fingerprints that were obtained from the analysis of the samples by UV-visible spectroscopy were used to build predictive model using PLS regression. The predictive ability of the models was evaluated through statistical parameters: the standard error of calibration (SEC), the standard error of validation (SEV), the correlation coefficient of calibration (r Cal) and validation (r Val), the ratio (SEC/SEV), the coefficient of determination R2, the paired data Student’s t-test, cross-validation and external validation. The results indicate that the PLS model predicts the concentration of biodiesel from African palm with high precision in mixtures with petrodiesel. The method developed in this study can be applied to determine the concentration of biodiesel African palm in mixtures of petrodiesel in a more rapid and economical way. Moreover, this method has less analytical errors and is more environmentally friendly than the conventional methods. 展开更多
关键词 AFRICAN Palm Petrodiesel/Biodiesel BLENDS Regression Model PLS Spectroscopy uv-visible
下载PDF
UV-radiation Dose Assessment for LR-115 Track Detector by Using UV-visible and FTIR Spectroscopy Techniques
18
作者 Hussain A. AI-Jobouri Fala Hatcm Taha 《Journal of Physical Science and Application》 2016年第1期88-91,共4页
Abstract: In the present work, studies the effect uv-radiation dose (5 J/cm2 to 360 J/cm2 ) with power 15 W to LR-115 track detector thickness 100 μm. Absorbance-A was measured at wavelength 600 nm and 650 nm by u... Abstract: In the present work, studies the effect uv-radiation dose (5 J/cm2 to 360 J/cm2 ) with power 15 W to LR-115 track detector thickness 100 μm. Absorbance-A was measured at wavelength 600 nm and 650 nm by usinguv-visible spectroscopy and measure the transmission percent -- T% and deviation at the wavenumber-w2907 cm1 by using Fourier infrared -- FTIR spectroscopy. The relationship between the dose of radiation to the uv-radiation (J/cm2) and the absorbance-A at wavelength 600 nm and 650 nm and the wavenumber-w 2907 cm-1 was calculate as a polynomial relation .The present study show that there is a possibility to use the detector LR- 115 to assessment doses of exposure to uv-radiation in the medical and environmental fields. 展开更多
关键词 LR-115 track detector UV-IRRADIATION uv-visible spectroscopy FTIR spectroscopy SSNTDs.
下载PDF
Flow Injection Analysis of Hydrazine in the Aqueous Streams of Purex Process by Liquid Chromatography System Coupled with UV-Visible Detector
19
作者 P. Velavendan S. Ganesh, N. K. Pandey +2 位作者 N. K. Pandey U. Kamachi Mudali R. Natarajan 《Journal of Analytical Sciences, Methods and Instrumentation》 2012年第3期156-160,共5页
Present study describes the development of a rapid, sensitive and selective flow injection analysis of hydrazine in the aqueous streams of purex process by liquid chromatography system coupled with UV-Visible detector... Present study describes the development of a rapid, sensitive and selective flow injection analysis of hydrazine in the aqueous streams of purex process by liquid chromatography system coupled with UV-Visible detector. The method is based on the formation of yellow coloured azine complex by reaction of hydrazine with para-dimethy laminobenzaldehyde (pDMAB). The formed yellow coloured complex is stable in acidic medium and has a maximum absorption at 460 nm. The presence of uranium in hydrazine solution is not interfering in the analysis. Under optimum condition, the absorption intensity linearly increased with the concentration of hydrazine in the range from 0.05-10 mg?L–1 with a correlation coefficient of R2=0.9999 (n=7). The experimental detection limit is 0.05mgL–1. The sampling frequency is 15 samples h–1 and the relative standard deviation was 2.1% for 0.05 mg?L–1. This method is suitable for automatic and continuous analysis and successfully applied to determine the concentration of hydrazine in the aqueous stream of nuclear fuel reprocessing. 展开更多
关键词 HYDRAZINE Liquid Chromatography PUREX Process Flow Injection Analysis Para-Dimethylaminobenaldehyde uv-vis DETECTOR
下载PDF
Bulk Etching of PET Studied by Spectrophotometer
20
作者 ZhuZhiyong DuanJinlai +3 位作者 SunYoumei Y.Maekawa H.Koshikawa M.Yoshida 《近代物理研究所和兰州重离子加速器实验室年报:英文版》 2003年第1期65-66,共2页
UV-VIS spectra of poly(ethylene terephthalate) (PET) solutions formed by etching PET in NaOH solution were analyzed with respect to the etching time. Two bands centered at 4.45 eV and 5.11 eV can be well separated (Fi... UV-VIS spectra of poly(ethylene terephthalate) (PET) solutions formed by etching PET in NaOH solution were analyzed with respect to the etching time. Two bands centered at 4.45 eV and 5.11 eV can be well separated (Fig.l). They are attributed to π→π^n transition from the chromophore of-O-CO-C6H4-CO-O-which is the main origin of optical absorption in the wavelength range from 240 nm to 320nm, both for the solid and dissolved PET. As shown in Fig.2, the integrated absorbance (A) of the two bands as well as weight loss of PET after etching in 0.74 N NaOH at 40°C increase linearly with etching time. A linear relationship between absorptions of the two bands and weight loss of PET in NaOH solution can therefore be established. As less than 2μg/ml of PET dissolved in NaOH solution can be resolved by spectrophotometer, it supplies a sensitive way to study the etching process even after very short time of etching. 展开更多
关键词 OH uv-vis CO PET
下载PDF
上一页 1 2 124 下一页 到第
使用帮助 返回顶部