The understanding of the excitation mechanism of ultra high frequency (UHF) electromagnetic waves (EW) is essential for ap- plying UHF method to partial discharge (PD) detection. Since the EW induced by PD in gas insu...The understanding of the excitation mechanism of ultra high frequency (UHF) electromagnetic waves (EW) is essential for ap- plying UHF method to partial discharge (PD) detection. Since the EW induced by PD in gas insulated switchgear (GIS) contains not only transverse electromagnetic (TEM) wave, but also high-order transverse electric (TE) and high-order transverse magnetic (TM) waves, we analyzed the proportions between the TEM wave and the high order waves, as well as the influence of the PD position on this proportion, using the finite different time domain (FDTD) method. According to the unique characteristics of the waves, they are separated only ap- proximately. It is found that the high-order mode is the main component, more than 70%, of the electric field around the enclosure of GIS, and that with the increasing distance between PD source and inner conductors, the low frequency ( below about 800 MHz) component of EW decreases, but the high frequency component (above 1 GHz) increases, meanwhile the proportion of high-order components in EW could reach 77% from 70%. It concluded that the closer the PD source to the enclosure is, the easier high order EW may be excited.展开更多
To investigate the partial discharge (PD) online monitoring of transformers by ultra-high-frequency (UHF) approaches,high-qualified UHF antennas are focused on as one key technique. The size of UHF sensor used for PD ...To investigate the partial discharge (PD) online monitoring of transformers by ultra-high-frequency (UHF) approaches,high-qualified UHF antennas are focused on as one key technique. The size of UHF sensor used for PD UHF online monitoring in transformer is excessively large,therefore,it is not convenient for internal installation of transformer. Two types of compact UHF antennas with small sizes,a Hilbert fractal antenna and a small loop antenna are presented. PD experiments of three typically artificial insulation defects are executed and both antennas are used for PD measurement. The spectra of power via frequency of detected PD signals are analyzed and compared. The experimental results show that the Hilbert fractal antenna and small loop antenna are qualified for PD online UHF monitoring.展开更多
特高频(ultra high frequency,UHF)局放检测是变压器油纸绝缘缺陷定位的常用方法,实际应用过程中局放定位准确性易受噪声和传感器布置方式影响。为保证变压器油纸绝缘缺陷局放定位检测有效性,文中首先建立油纸绝缘缺陷UHF局放定位检测平...特高频(ultra high frequency,UHF)局放检测是变压器油纸绝缘缺陷定位的常用方法,实际应用过程中局放定位准确性易受噪声和传感器布置方式影响。为保证变压器油纸绝缘缺陷局放定位检测有效性,文中首先建立油纸绝缘缺陷UHF局放定位检测平台,在常规K-means方法的基础上,提出基于修正聚类分界的变压器油纸绝缘缺陷局放抗干扰定位方法,有效降低了定位误差。然后针对样本聚类分界混叠问题,选择最优修正系数L为1.1时,UHF局放定位误差可减小至0.1 m内,验证了文中方法的有效性。最后分析不同传感器布置方式的定位误差变化规律,提出变压器油纸绝缘缺陷检测用UHF传感器优化布置方案,可为变压器局放在线监测传感器布置及定位提供参考。展开更多
基金Project supported by National High-tech Research and Development Program of China (863 Program) (2011AA05A121)
文摘The understanding of the excitation mechanism of ultra high frequency (UHF) electromagnetic waves (EW) is essential for ap- plying UHF method to partial discharge (PD) detection. Since the EW induced by PD in gas insulated switchgear (GIS) contains not only transverse electromagnetic (TEM) wave, but also high-order transverse electric (TE) and high-order transverse magnetic (TM) waves, we analyzed the proportions between the TEM wave and the high order waves, as well as the influence of the PD position on this proportion, using the finite different time domain (FDTD) method. According to the unique characteristics of the waves, they are separated only ap- proximately. It is found that the high-order mode is the main component, more than 70%, of the electric field around the enclosure of GIS, and that with the increasing distance between PD source and inner conductors, the low frequency ( below about 800 MHz) component of EW decreases, but the high frequency component (above 1 GHz) increases, meanwhile the proportion of high-order components in EW could reach 77% from 70%. It concluded that the closer the PD source to the enclosure is, the easier high order EW may be excited.
基金Project Supported by New Century ExcellentTalents of the Ministry of Education (NCET-06-0763)the Foundation of the Key Project of the Science and Technology Depart ment inChongqing (CSTC2005AA6003)
文摘To investigate the partial discharge (PD) online monitoring of transformers by ultra-high-frequency (UHF) approaches,high-qualified UHF antennas are focused on as one key technique. The size of UHF sensor used for PD UHF online monitoring in transformer is excessively large,therefore,it is not convenient for internal installation of transformer. Two types of compact UHF antennas with small sizes,a Hilbert fractal antenna and a small loop antenna are presented. PD experiments of three typically artificial insulation defects are executed and both antennas are used for PD measurement. The spectra of power via frequency of detected PD signals are analyzed and compared. The experimental results show that the Hilbert fractal antenna and small loop antenna are qualified for PD online UHF monitoring.
文摘特高频(ultra high frequency,UHF)局放检测是变压器油纸绝缘缺陷定位的常用方法,实际应用过程中局放定位准确性易受噪声和传感器布置方式影响。为保证变压器油纸绝缘缺陷局放定位检测有效性,文中首先建立油纸绝缘缺陷UHF局放定位检测平台,在常规K-means方法的基础上,提出基于修正聚类分界的变压器油纸绝缘缺陷局放抗干扰定位方法,有效降低了定位误差。然后针对样本聚类分界混叠问题,选择最优修正系数L为1.1时,UHF局放定位误差可减小至0.1 m内,验证了文中方法的有效性。最后分析不同传感器布置方式的定位误差变化规律,提出变压器油纸绝缘缺陷检测用UHF传感器优化布置方案,可为变压器局放在线监测传感器布置及定位提供参考。