In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc...In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil.展开更多
The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, a...The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. The chromatographic method employed was as follows: the column was a Welch Ultimate XB-C18 column (250 mm × 4.6 mm, 10 μm), the mobile phase was a gradient elution of 0.4% formic acid aqueous solution (A) and acetonitrile (B), the detection wavelengths were 280 nm for sodium danshensu, protocatechuic aldehyde, and salvianolic acid B and 326 nm for 4-coumaric acid and rosmarinic acid, the sample volume was 10 μL, the flow rate was 1.0 mL/min, and the column temperature was 35°C. This method can realize the separation and determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid within 50 minutes. The linear relationships of the five peak areas and their concentrations are good (R2> 0.9997). The precision RSD values are all less than 1.0%. The reproducibility RSD values are all less than 1.3%. The stability RSD values are all less than 2.2%. The recovery values ranged from 92.4% to 99.4%. This method is simple, accurate, and reproducible. It can be used for the determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection.展开更多
A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxyte...A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC) and their 4-epimers (4-epiTCs) in agricultural soil fertilized with swine manure. Soil samples were extracted and cleaned-up with 10 mL EDTA-McIlvaine buffer solution (pH 4.0), then cleaned-up and pre-concentrated using the Oasis MAX cartridge and then eluted with 1 mL solution by mixing formic acid, methanol and water at a ratio of 2:15:83 (v/v/v). The purified samples were separated by an ACQUITY UPLC BEH C18 column using acetonitrile and water containing 0.1% formic acid mobile phase and detected by a single quadrupole MS. The limits of detection for the soil extraction method (LODsoil) ranged from 0.6-2.5 lag kg-~ with recoveries from 23.3-159.2%. Finally, the method was applied to an agricultural field in an area with intensive pig-fattening farming. Tetracyclines were detected in soil from 2.8 to 42.4 μg kg-1 soil. These results demonstrate that soil from swine farms can become severely contaminated with tetracycline antibiotics and their metabolites.展开更多
[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical c...[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical components of A. bidentata leaves were rapidly analyzed using the ultra high performance liquid chromatography-time of flight-high resolution mass spectrometry (UHPLC-TOF-MS).[Results] Thirty eight chemical compounds were identified in samples of A. bidentata leaves collected from Wen County of Henan Province, in which seven chemical compounds had the relative content higher than 5%, linoleic acid reached 25.7% and inokosterone A reached 13.8%.[Conclusions] A. bidentata leaves contain many kinds of chemical compounds. This study is expected to provide a certain basis for further extraction of linoleic acid and inokosterone A.展开更多
This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile sampl...This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles.展开更多
In this study, a new technique was developed using rapid ultra-performance liquid chromatography (UPLC)-based separation coupled with electrochemical detection by a boron-doped diamond (BDD) electrode for the detectio...In this study, a new technique was developed using rapid ultra-performance liquid chromatography (UPLC)-based separation coupled with electrochemical detection by a boron-doped diamond (BDD) electrode for the detection and quantification of three commonly used parabens (methylparaben (MP), ethylparaben (EP) and propylparaben (PP)). We aimed to reduce the analysis time by using UPLC coupled with a short reverse phase C 18 monolithic column (25 mm×4.6 mm). Operating the monolithic column at low back-pressure resulted in high flow rates. A mobile phaseconsisting of a 25:75 (v/v) ratio of acetonitrile:0.05 Mphosphate buffer (pH 5) at a flow rate of 2.5 mL·min?1 was used to perform the separation. The amperometric detection with the BDD electrode was found to be optimal and reliably reproducible at a detection potential of 1.5 V vs. Ag/AgCl. Under these conditions, the separation of the three targetanalytes (MP, EP and PP) was achieved in 2 min and was linear within a sample concentration range of 0.1 to 50.0 mg·L?1 (r2 values of 0.9970, 0.9994 and 0.9994 for MP, EP and PP, respectively). This method was successfully applied to determine the concentrations of each parabeninsix real samples with therecoveries ranging from of 80.3% - 98.9% for all three parabensfrom samples spiked at 12, 22 and 32 mg·L?1. Therefore, the proposed method can be used as an alternative rapid and selective method for the determination of paraben levels in real samples.展开更多
A novel method for simultaneous determination of kolliphor HS15 and miglyol 812 in microemulsion formulation was developed using ultra-high performance liquid chromatography coupled with a nano quantitation analytical...A novel method for simultaneous determination of kolliphor HS15 and miglyol 812 in microemulsion formulation was developed using ultra-high performance liquid chromatography coupled with a nano quantitation analytical detector (UHPLC-NQAD). All components in kolliphor HS15 and miglyo1812 were well separated on an Acquity BEH C18 column. Mobile phase A was 0.1% trifluoroacetic acid (TFA) in water and mobile phase B was acetonitrile. A gradient elution sequence was programed initially with 60% organic solvent, slowly increased to 100% within 8 min. The flow rate was 0.7 mL/min. Good linearity (r 〉 0.95) was obtained in the range of 27.6-1381.1 μg/mL for polyoxyl 15 hydroxystearate in kolliphor HS15, 0.8-202.0 μg/mL for caprylic acid triglyceride and 2.7-221.9μg/mL for capric acid triglyceride in miglyol 812. The relative standard deviations (RSD) ranged from 0.6% to 1.7% for intra-day precision and from 0.4% to 2.7% for inter-day precision. The overall recoveries (accuracy) were 99.7%-101.4% for polyoxyl 15 hydroxystearate in kolliphor HS15, 96.7%-99.6% for caprylic acid triglyceride, and 94.1%- 103.3% for capric acid triglyceride in miglyol 812. Quantification limits (QL) were determined as 27.6 μg/ mL for polyoxy115 hydroxystearate in kolliphor HS15, 0.8 μg/mL for caprylic acid triglyceride, and 2.7 μg/ mL for capric acid triglyceride in miglyol 812. No interferences were observed in the retention time ranges of kolliphor HSI5 and miglyol 812. The method was validated in terms of specificity, linearity, precision, accuracy, QL, and robustness. The proposed method has been applied to microemulsion for- mulation analyses with good recoveries (82.2%-103.4%).展开更多
Introduction: Conventional metabolite analyses often require manual sample preparation, generating variability of measurements. This study describes a new method to quantify radiometabolites in blood, combining ultra ...Introduction: Conventional metabolite analyses often require manual sample preparation, generating variability of measurements. This study describes a new method to quantify radiometabolites in blood, combining ultra high performance liquid chromatography (UHPLC) and turbulent flow chromatography, an alternative fully automated process allowing analyte’s extraction. Methods: A new radiotracer for dopamine transporter imaging, namely LBT-999, was used to demonstrate the method’s robustness. Matrix effect, Turboflow column loading, linearity, specificity and precision were evaluated with in vitro samples of LBT-999 in human plasma. Radiodetector sensitivity and preliminary evaluation were respectively determined by analysis of calibrated samples of [18F]LBT-999 and blood samples from 4 healthy subjects injected with [18F]LBT-999, withdrawn at 5, 15, 30 and 45 min pi. Results: With three sequential loadings (3 × 100 μL) of the Turboflow column, mean coefficients of variation were 1%, below 2%, 2% and 30.9% for matrix effect, specificity, repeatability and intermediate precision, respectively. Correlation coefficients for linearity were superior to 0.97. Limits of detection and quantification of the radiodetector were fixed at 3 and 9 c/s. Retention times for [18F]LBT-999 and the two radiometabolites detected by radio-UHPLC were 6.5, 4.8 and 9.6 min. Forty-five min after the injection, parent fraction was still predominant with 57.8% ± 25% of the total radioactivity. Conclusions: An innovative approach, allying UHPLC and Turboflow column, was developed and its sensitivity, linearity, specificity and repeatability validated. Preliminary results of the clinical trial are in accordance with literature data, demonstrating its efficiency in radiometabolites quantification.展开更多
Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC...Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine.展开更多
The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Gi...The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy.展开更多
The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamox...The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamoxifen (TAM) in biological fluids including human urine and plasma. The drug was extracted from a 15 mL aqueous sample (source phase;SP) into an organic phase impregnated in the pores of the hollow fiber (membrane phase;MP) followed by the back-extraction into a second aqueous solution (receiving phase;RP) located in the lumen of the hollow fiber. The effects of several factors such as the nature of organic solvent, compositions of SP and RP solutions, extraction time, ionic strength and stirring rate on the extraction efficiency were examined and optimized. An enrichment factor of 360 along with substantial sample clean up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 1 - 500 ng?mL–1 and the limit of detection was found to be 0.5 ng?mL–1 in aqueous medium. A reasonable relative recovery (≥89%) and satisfactory intra-assay (3.7% - 4.2%, n = 3) and inter-assay (7.5% - 7.8%, n = 3) precision illustrated good performance of the analytical procedure in spiked human urine and plasma samples.展开更多
A 64-year-old woman with IgA kappa multiple myeloma was treated with thalidomide-dexa- methasone. Due to progression of the disease, bortezomib, doxorubicin and dexamethasone were administered, followed by autologous ...A 64-year-old woman with IgA kappa multiple myeloma was treated with thalidomide-dexa- methasone. Due to progression of the disease, bortezomib, doxorubicin and dexamethasone were administered, followed by autologous stem cell transplantation. Although near-complete remission was achieved, 5 months later, neuro- logical symptoms appeared and the patient was diagnosed with multiple myeloma with cells in- filtrating the spinal cord. Bis-chloronitrosourea, bortezomib and lenalidomide were then admin- istered and although the patient remained neu- rologically asymptomatic, she died 3 months later becausee of disease progression. Lena- lidomide entered into the cerebrospinal fluid (confirmed by ultrasensitive high-performance liquid chromatography), although did not im- prove the poor prognosis of multiple myeloma involving the central nervous system.展开更多
To develop a sensitive high performance liquid chromatography (HPLC) assay for the determination of trans-resveratrol in mouse liver. The whole liver of a mouse was removed from the body, homogenated, and extracted ...To develop a sensitive high performance liquid chromatography (HPLC) assay for the determination of trans-resveratrol in mouse liver. The whole liver of a mouse was removed from the body, homogenated, and extracted by ethyl acetate. The organic layer was isolated and evaporated to dryness, the residue was reconstituted in 0.2 mL mobile phase for centrifugation, and 50 uL of the supernatant was injected into the/-IPLC instrument. The sample was separated on a Shimadzu ODS column (150 mm × 4.6 mm, 5 um) at 35 ℃ and detected by ultraviolet (UV) detector at the wavelength of 305 nm. The mobile phase consisted of methanol and 0.1 mol/L acetic acid (4:6, v/v) with the flow-rote at 1 mL/min. The limit of detection was 3.0 ng/g in liver homogenate with a signal/noise ratio of 3:1. The linear range of the calibration curve was 5.0-120.0 ng/g. The mean recoveries at the concentrations of 6, 10 and 80 ng/g were 102%, 96.0% and 91.5%, respectively. The RSDs for inter- and intra-day assays were less than 5%. Compared with other reported methods, this method was faster and more sensitive. It was also proved to be of good linearity, selectivity, accuracy and precision, and can be efficiently applied to the pharmacoldnetic study of trans-resveratrol in mouse liver.展开更多
A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) ...A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples.展开更多
AIM: To observe the effect of protocatechuic aldchyde on the proliferation of hepatic stellate cells (HSCs). METHODS: Liver fibrosis was induced in rats by carbon tetrachloride (CCh). Then normal and fibrotic dr...AIM: To observe the effect of protocatechuic aldchyde on the proliferation of hepatic stellate cells (HSCs). METHODS: Liver fibrosis was induced in rats by carbon tetrachloride (CCh). Then normal and fibrotic drug sera were extracted from rats. The effects of protocatechuic aldchyde, raw Radix Salvia miltiorrhiza and drug sera of Salvia miltiorrhiza on HSC growth were determined by CCKoS. The protocatechuic aldchyde was separated by high performance liquid chromatography (HPLC) in a AIItima C18 column (250 mm × 4.6 mm, 5 μm) with a mobile phase of acetonitrile-4% glacial acetic acid solution (gradient elution) at the wavelength of 281 nm. RESULTS: Protocatechuic aldchyde, raw Radix Salvia miltiorrhiza and drug sera of Salvia miltiorrhiza were found to have inhibitory effects on proliferation of rat HSCs. Raw Radix Salvia miltiorrhiza had a stronger inhibitory effect than the drug sera. The fibrotic drug sera showed a higher suppressive effect than the normal drug sera (P 〈 0.05). Protocatechuic aldchyde was found in crude materials of both Radix Salvia miltiorrhiza and its corresponding drug sera. The average recovery (n = 6) was 110.5% for raw Salvia miltiorrhiza Bge, 102% for normal drug sera and 105.2% for fibrotic drug sera. The relative standard devitation (RSD) was 0.37%, 1.96% and 1.51%, respectively (n=6). The contents of protocatechuic aldchyde were 0.22%, 0.15% and 0.19%, respectively (n = 6) (P〈 0.05). The RSD was 0.33%, 0.75% and 1.24% (n=6) for raw material of Radix Salvia miltiorrhiza, normal drug sera and fibrotic drug sera, respectively. The samples were stable for 6 d. CONCLUSION: Protocatechuic aldchyde can inhibit the growth of HSCs. HPLC is suitable for the determination of virtual bioactive components of Chinese herbal medicines in vitro.展开更多
Methods for determining nine low molecular weight organic acids in root exudates were developed by using reversed phase high performance liquid chromatography with UV (ultraviolet) detection at 214 nm. The mobile ph...Methods for determining nine low molecular weight organic acids in root exudates were developed by using reversed phase high performance liquid chromatography with UV (ultraviolet) detection at 214 nm. The mobile phase was 18 mmol L -1 kH 2PO 4 adjusted to pH 2.25 with phosphoric acid and the flow rate was 0.3 mL min -1 . The analytical column was a reversed phase silica based C 18 column (Shim pack CLC ODS). The root exudates were collected through submerging the whole root system into aerated deionized water for 2 hours. The filtered exudate solutions were concentrated to dryness by rotary evaporation at 40 °C, dissolved in 10 mL mobile phase. The chromatographic conditions of organic acid determination were analyzed. The results showed that there was a high selectivity and sensitivity in the organic acid determination by reversed phase high performance liquid chromatography. Coefficients of variation for organic acid determination were lower than 10% except lactic acid. The recoveries were consistently between 80.1% to 108.3%. Detection limits were approximately 0.05 to 4.5 mg L -1 for organic acids except succinic acid with the detection limit of 7.0 mg L -1 . Phosphorus deficiency may contribute to the release of organic acids in soybean root exudates especially malic, lactic and citric acids.展开更多
HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns. symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile ph...HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns. symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile phase, which can eliminate the time for cleaning the chromatographic system and simplify the analystic method for GBE Experimental conditions: column: Hypersil BDS C-18, 5mumx4x250 mm: column temperature: 35degreesC; mobile phase: 46% methanol-54% water; flow rate: 0.7 mL/min; detection wavelength: 360nm.展开更多
The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard fo...The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition.展开更多
A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 s...A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues.展开更多
Objective: To develop the representative fingerprint for the quality control of placenta polypeptide injection. Methods: The chromatographic separation was performed using a Phenomenex Gemini C18 column (250 mm 4.6 mm...Objective: To develop the representative fingerprint for the quality control of placenta polypeptide injection. Methods: The chromatographic separation was performed using a Phenomenex Gemini C18 column (250 mm 4.6 mm, 5 mm) maintained at 30 1C. 0.1% aqueous trifiuoroacetic acid (Solvent A) and acetonitrile contained 0.1% TFA (Solvent B) were used as mobile phase with a gradient elution. Detection wavelength was 280 nm with the sample injection volume of 50 mL; the fiow rate was 1.0 mL/min. The fingerprints of different samples were investigated by similarity analysis. Results: Nine peaks were identified as the characteristic common peaks. The similarities of the fingerprints of the 10 batches of samples were above 0.992. Conclusion: This method showed high precision and good repeatability, and provided the basis for the improvement of the quality control of placenta polypeptide injection.展开更多
文摘In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil.
文摘The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. The chromatographic method employed was as follows: the column was a Welch Ultimate XB-C18 column (250 mm × 4.6 mm, 10 μm), the mobile phase was a gradient elution of 0.4% formic acid aqueous solution (A) and acetonitrile (B), the detection wavelengths were 280 nm for sodium danshensu, protocatechuic aldehyde, and salvianolic acid B and 326 nm for 4-coumaric acid and rosmarinic acid, the sample volume was 10 μL, the flow rate was 1.0 mL/min, and the column temperature was 35°C. This method can realize the separation and determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid within 50 minutes. The linear relationships of the five peak areas and their concentrations are good (R2> 0.9997). The precision RSD values are all less than 1.0%. The reproducibility RSD values are all less than 1.3%. The stability RSD values are all less than 2.2%. The recovery values ranged from 92.4% to 99.4%. This method is simple, accurate, and reproducible. It can be used for the determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection.
文摘A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC) and their 4-epimers (4-epiTCs) in agricultural soil fertilized with swine manure. Soil samples were extracted and cleaned-up with 10 mL EDTA-McIlvaine buffer solution (pH 4.0), then cleaned-up and pre-concentrated using the Oasis MAX cartridge and then eluted with 1 mL solution by mixing formic acid, methanol and water at a ratio of 2:15:83 (v/v/v). The purified samples were separated by an ACQUITY UPLC BEH C18 column using acetonitrile and water containing 0.1% formic acid mobile phase and detected by a single quadrupole MS. The limits of detection for the soil extraction method (LODsoil) ranged from 0.6-2.5 lag kg-~ with recoveries from 23.3-159.2%. Finally, the method was applied to an agricultural field in an area with intensive pig-fattening farming. Tetracyclines were detected in soil from 2.8 to 42.4 μg kg-1 soil. These results demonstrate that soil from swine farms can become severely contaminated with tetracycline antibiotics and their metabolites.
基金Supported by Key Scientific and Technological Research Project in Higher Education Institutions of Henan Province(17A350002)Project of National Natural Science Foundation of China(81172953)
文摘[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical components of A. bidentata leaves were rapidly analyzed using the ultra high performance liquid chromatography-time of flight-high resolution mass spectrometry (UHPLC-TOF-MS).[Results] Thirty eight chemical compounds were identified in samples of A. bidentata leaves collected from Wen County of Henan Province, in which seven chemical compounds had the relative content higher than 5%, linoleic acid reached 25.7% and inokosterone A reached 13.8%.[Conclusions] A. bidentata leaves contain many kinds of chemical compounds. This study is expected to provide a certain basis for further extraction of linoleic acid and inokosterone A.
文摘This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles.
文摘In this study, a new technique was developed using rapid ultra-performance liquid chromatography (UPLC)-based separation coupled with electrochemical detection by a boron-doped diamond (BDD) electrode for the detection and quantification of three commonly used parabens (methylparaben (MP), ethylparaben (EP) and propylparaben (PP)). We aimed to reduce the analysis time by using UPLC coupled with a short reverse phase C 18 monolithic column (25 mm×4.6 mm). Operating the monolithic column at low back-pressure resulted in high flow rates. A mobile phaseconsisting of a 25:75 (v/v) ratio of acetonitrile:0.05 Mphosphate buffer (pH 5) at a flow rate of 2.5 mL·min?1 was used to perform the separation. The amperometric detection with the BDD electrode was found to be optimal and reliably reproducible at a detection potential of 1.5 V vs. Ag/AgCl. Under these conditions, the separation of the three targetanalytes (MP, EP and PP) was achieved in 2 min and was linear within a sample concentration range of 0.1 to 50.0 mg·L?1 (r2 values of 0.9970, 0.9994 and 0.9994 for MP, EP and PP, respectively). This method was successfully applied to determine the concentrations of each parabeninsix real samples with therecoveries ranging from of 80.3% - 98.9% for all three parabensfrom samples spiked at 12, 22 and 32 mg·L?1. Therefore, the proposed method can be used as an alternative rapid and selective method for the determination of paraben levels in real samples.
文摘A novel method for simultaneous determination of kolliphor HS15 and miglyol 812 in microemulsion formulation was developed using ultra-high performance liquid chromatography coupled with a nano quantitation analytical detector (UHPLC-NQAD). All components in kolliphor HS15 and miglyo1812 were well separated on an Acquity BEH C18 column. Mobile phase A was 0.1% trifluoroacetic acid (TFA) in water and mobile phase B was acetonitrile. A gradient elution sequence was programed initially with 60% organic solvent, slowly increased to 100% within 8 min. The flow rate was 0.7 mL/min. Good linearity (r 〉 0.95) was obtained in the range of 27.6-1381.1 μg/mL for polyoxyl 15 hydroxystearate in kolliphor HS15, 0.8-202.0 μg/mL for caprylic acid triglyceride and 2.7-221.9μg/mL for capric acid triglyceride in miglyol 812. The relative standard deviations (RSD) ranged from 0.6% to 1.7% for intra-day precision and from 0.4% to 2.7% for inter-day precision. The overall recoveries (accuracy) were 99.7%-101.4% for polyoxyl 15 hydroxystearate in kolliphor HS15, 96.7%-99.6% for caprylic acid triglyceride, and 94.1%- 103.3% for capric acid triglyceride in miglyol 812. Quantification limits (QL) were determined as 27.6 μg/ mL for polyoxy115 hydroxystearate in kolliphor HS15, 0.8 μg/mL for caprylic acid triglyceride, and 2.7 μg/ mL for capric acid triglyceride in miglyol 812. No interferences were observed in the retention time ranges of kolliphor HSI5 and miglyol 812. The method was validated in terms of specificity, linearity, precision, accuracy, QL, and robustness. The proposed method has been applied to microemulsion for- mulation analyses with good recoveries (82.2%-103.4%).
文摘Introduction: Conventional metabolite analyses often require manual sample preparation, generating variability of measurements. This study describes a new method to quantify radiometabolites in blood, combining ultra high performance liquid chromatography (UHPLC) and turbulent flow chromatography, an alternative fully automated process allowing analyte’s extraction. Methods: A new radiotracer for dopamine transporter imaging, namely LBT-999, was used to demonstrate the method’s robustness. Matrix effect, Turboflow column loading, linearity, specificity and precision were evaluated with in vitro samples of LBT-999 in human plasma. Radiodetector sensitivity and preliminary evaluation were respectively determined by analysis of calibrated samples of [18F]LBT-999 and blood samples from 4 healthy subjects injected with [18F]LBT-999, withdrawn at 5, 15, 30 and 45 min pi. Results: With three sequential loadings (3 × 100 μL) of the Turboflow column, mean coefficients of variation were 1%, below 2%, 2% and 30.9% for matrix effect, specificity, repeatability and intermediate precision, respectively. Correlation coefficients for linearity were superior to 0.97. Limits of detection and quantification of the radiodetector were fixed at 3 and 9 c/s. Retention times for [18F]LBT-999 and the two radiometabolites detected by radio-UHPLC were 6.5, 4.8 and 9.6 min. Forty-five min after the injection, parent fraction was still predominant with 57.8% ± 25% of the total radioactivity. Conclusions: An innovative approach, allying UHPLC and Turboflow column, was developed and its sensitivity, linearity, specificity and repeatability validated. Preliminary results of the clinical trial are in accordance with literature data, demonstrating its efficiency in radiometabolites quantification.
文摘Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine.
文摘The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy.
文摘The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamoxifen (TAM) in biological fluids including human urine and plasma. The drug was extracted from a 15 mL aqueous sample (source phase;SP) into an organic phase impregnated in the pores of the hollow fiber (membrane phase;MP) followed by the back-extraction into a second aqueous solution (receiving phase;RP) located in the lumen of the hollow fiber. The effects of several factors such as the nature of organic solvent, compositions of SP and RP solutions, extraction time, ionic strength and stirring rate on the extraction efficiency were examined and optimized. An enrichment factor of 360 along with substantial sample clean up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 1 - 500 ng?mL–1 and the limit of detection was found to be 0.5 ng?mL–1 in aqueous medium. A reasonable relative recovery (≥89%) and satisfactory intra-assay (3.7% - 4.2%, n = 3) and inter-assay (7.5% - 7.8%, n = 3) precision illustrated good performance of the analytical procedure in spiked human urine and plasma samples.
文摘A 64-year-old woman with IgA kappa multiple myeloma was treated with thalidomide-dexa- methasone. Due to progression of the disease, bortezomib, doxorubicin and dexamethasone were administered, followed by autologous stem cell transplantation. Although near-complete remission was achieved, 5 months later, neuro- logical symptoms appeared and the patient was diagnosed with multiple myeloma with cells in- filtrating the spinal cord. Bis-chloronitrosourea, bortezomib and lenalidomide were then admin- istered and although the patient remained neu- rologically asymptomatic, she died 3 months later becausee of disease progression. Lena- lidomide entered into the cerebrospinal fluid (confirmed by ultrasensitive high-performance liquid chromatography), although did not im- prove the poor prognosis of multiple myeloma involving the central nervous system.
基金Postdoctoral Scientific Research Station of Gansu Yasheng Groups.
文摘To develop a sensitive high performance liquid chromatography (HPLC) assay for the determination of trans-resveratrol in mouse liver. The whole liver of a mouse was removed from the body, homogenated, and extracted by ethyl acetate. The organic layer was isolated and evaporated to dryness, the residue was reconstituted in 0.2 mL mobile phase for centrifugation, and 50 uL of the supernatant was injected into the/-IPLC instrument. The sample was separated on a Shimadzu ODS column (150 mm × 4.6 mm, 5 um) at 35 ℃ and detected by ultraviolet (UV) detector at the wavelength of 305 nm. The mobile phase consisted of methanol and 0.1 mol/L acetic acid (4:6, v/v) with the flow-rote at 1 mL/min. The limit of detection was 3.0 ng/g in liver homogenate with a signal/noise ratio of 3:1. The linear range of the calibration curve was 5.0-120.0 ng/g. The mean recoveries at the concentrations of 6, 10 and 80 ng/g were 102%, 96.0% and 91.5%, respectively. The RSDs for inter- and intra-day assays were less than 5%. Compared with other reported methods, this method was faster and more sensitive. It was also proved to be of good linearity, selectivity, accuracy and precision, and can be efficiently applied to the pharmacoldnetic study of trans-resveratrol in mouse liver.
基金supported both by the Natural Science Foundations of Hebei(No.B2008000210)the Scientific Research Foundation of Agricultural University of Hebei.
文摘A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples.
文摘AIM: To observe the effect of protocatechuic aldchyde on the proliferation of hepatic stellate cells (HSCs). METHODS: Liver fibrosis was induced in rats by carbon tetrachloride (CCh). Then normal and fibrotic drug sera were extracted from rats. The effects of protocatechuic aldchyde, raw Radix Salvia miltiorrhiza and drug sera of Salvia miltiorrhiza on HSC growth were determined by CCKoS. The protocatechuic aldchyde was separated by high performance liquid chromatography (HPLC) in a AIItima C18 column (250 mm × 4.6 mm, 5 μm) with a mobile phase of acetonitrile-4% glacial acetic acid solution (gradient elution) at the wavelength of 281 nm. RESULTS: Protocatechuic aldchyde, raw Radix Salvia miltiorrhiza and drug sera of Salvia miltiorrhiza were found to have inhibitory effects on proliferation of rat HSCs. Raw Radix Salvia miltiorrhiza had a stronger inhibitory effect than the drug sera. The fibrotic drug sera showed a higher suppressive effect than the normal drug sera (P 〈 0.05). Protocatechuic aldchyde was found in crude materials of both Radix Salvia miltiorrhiza and its corresponding drug sera. The average recovery (n = 6) was 110.5% for raw Salvia miltiorrhiza Bge, 102% for normal drug sera and 105.2% for fibrotic drug sera. The relative standard devitation (RSD) was 0.37%, 1.96% and 1.51%, respectively (n=6). The contents of protocatechuic aldchyde were 0.22%, 0.15% and 0.19%, respectively (n = 6) (P〈 0.05). The RSD was 0.33%, 0.75% and 1.24% (n=6) for raw material of Radix Salvia miltiorrhiza, normal drug sera and fibrotic drug sera, respectively. The samples were stable for 6 d. CONCLUSION: Protocatechuic aldchyde can inhibit the growth of HSCs. HPLC is suitable for the determination of virtual bioactive components of Chinese herbal medicines in vitro.
文摘Methods for determining nine low molecular weight organic acids in root exudates were developed by using reversed phase high performance liquid chromatography with UV (ultraviolet) detection at 214 nm. The mobile phase was 18 mmol L -1 kH 2PO 4 adjusted to pH 2.25 with phosphoric acid and the flow rate was 0.3 mL min -1 . The analytical column was a reversed phase silica based C 18 column (Shim pack CLC ODS). The root exudates were collected through submerging the whole root system into aerated deionized water for 2 hours. The filtered exudate solutions were concentrated to dryness by rotary evaporation at 40 °C, dissolved in 10 mL mobile phase. The chromatographic conditions of organic acid determination were analyzed. The results showed that there was a high selectivity and sensitivity in the organic acid determination by reversed phase high performance liquid chromatography. Coefficients of variation for organic acid determination were lower than 10% except lactic acid. The recoveries were consistently between 80.1% to 108.3%. Detection limits were approximately 0.05 to 4.5 mg L -1 for organic acids except succinic acid with the detection limit of 7.0 mg L -1 . Phosphorus deficiency may contribute to the release of organic acids in soybean root exudates especially malic, lactic and citric acids.
文摘HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns. symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile phase, which can eliminate the time for cleaning the chromatographic system and simplify the analystic method for GBE Experimental conditions: column: Hypersil BDS C-18, 5mumx4x250 mm: column temperature: 35degreesC; mobile phase: 46% methanol-54% water; flow rate: 0.7 mL/min; detection wavelength: 360nm.
文摘The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition.
基金supported by the Natural Science Foundation of Zhejiang Province,China(No.LY17C200009)the Foundation of Zhejiang Educational Committee(No.Y201328477)
文摘A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues.
文摘Objective: To develop the representative fingerprint for the quality control of placenta polypeptide injection. Methods: The chromatographic separation was performed using a Phenomenex Gemini C18 column (250 mm 4.6 mm, 5 mm) maintained at 30 1C. 0.1% aqueous trifiuoroacetic acid (Solvent A) and acetonitrile contained 0.1% TFA (Solvent B) were used as mobile phase with a gradient elution. Detection wavelength was 280 nm with the sample injection volume of 50 mL; the fiow rate was 1.0 mL/min. The fingerprints of different samples were investigated by similarity analysis. Results: Nine peaks were identified as the characteristic common peaks. The similarities of the fingerprints of the 10 batches of samples were above 0.992. Conclusion: This method showed high precision and good repeatability, and provided the basis for the improvement of the quality control of placenta polypeptide injection.