期刊文献+
共找到1,788篇文章
< 1 2 90 >
每页显示 20 50 100
The Application of Ultra High Voltage in the World 被引量:3
1
作者 Metin Candas Ozlem Sahin Meric 《Journal of Power and Energy Engineering》 2015年第4期453-457,共5页
With rapidly growth in industrial sectors, in order to meet the demand, the usage of Ultra High Voltage (UHV) is needed. High voltage (HV) is between the range of 52 kV and 300 kV. In case of voltage above 800 kV, it ... With rapidly growth in industrial sectors, in order to meet the demand, the usage of Ultra High Voltage (UHV) is needed. High voltage (HV) is between the range of 52 kV and 300 kV. In case of voltage above 800 kV, it can be defined as UHV. With the development of technologies in the world, it could be seen that Japan, Russia, Italy, Brazil, America (U.S), and Canada began to improve UHV in the 1960s and 1970s. In addition, China, a leader developing country for UHV technologies in the world, started UHV technologies in transmission, in 1980s. Nowadays, seven transmission lines are in operation in China. In this study, the concept of HV and UHV will be introduced. Especially, UHV transmission in the worldwide will be researched. Then, the historical development and current situation of UHV will be analyzed and the assessment for Turkey will be done. 展开更多
关键词 The APPLICATION of ultra high voltage in the World
下载PDF
Statistical characteristics of transient enclosure voltage in ultra-high-voltage gas-insulated switchgear 被引量:2
2
作者 Yuanji CAI Yonggang GUAN Weidong LIU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第6期74-81,共8页
Transient enclosure voltage(TEV),which is a phenomenon induced by the inner dielectric breakdown of SF_6 during disconnector operations in a gas-insulated switchgear(GIS),may cause issues relating to shock hazard ... Transient enclosure voltage(TEV),which is a phenomenon induced by the inner dielectric breakdown of SF_6 during disconnector operations in a gas-insulated switchgear(GIS),may cause issues relating to shock hazard and electromagnetic interference to secondary equipment.This is a critical factor regarding the electromagnetic compatibility of ultra-high-voltage(UHV)substations.In this paper,the statistical characteristics of TEV at UHV level are collected from field experiments,and are analyzed and compared to those from a repeated strike process.The TEV waveforms during disconnector operations are recorded by a self-developed measurement system first.Then,statistical characteristics,such as the pulse number,duration of pulses,frequency components,magnitude and single pulse duration,are extracted.The transmission line theory is introduced to analyze the TEV and is validated by the experimental results.Finally,the relationship between the TEV and the repeated strike process is analyzed.This proves that the pulse voltage of the TEV is proportional to the corresponding breakdown voltage.The results contribute to the definition of the standard testing waveform of the TEV,and can aid the protection of electronic devices in substations by minimizing the threat of this phenomenon. 展开更多
关键词 transient enclosure voltage (TEV) gas-insulated switchgear (GIS) ultra-high-voltage uhv repeated strike process DISCONNECTOR
下载PDF
Three-Dimensional Analysis of Melanosomes Isolated from B16 Melanoma Cells by Using Ultra High Voltage Electron Microscopy 被引量:1
3
作者 Shuuichi Akazaki Toshie Takahashi +7 位作者 Yujiro Nakano Tomoki Nishida Hirotarou Mori Akio Takaoka Hitomi Aoki Huayua Chen Takahiro Kunisada Kenzo Koike 《Microscopy Research》 2014年第1期1-8,共8页
Melanosomes, isolated by centrifugal separation from culture broth of B16 melanoma cells derived from mouse, were observed by scanning electron microscopy (SEM), and by transmission electron microscopy (TEM). Some int... Melanosomes, isolated by centrifugal separation from culture broth of B16 melanoma cells derived from mouse, were observed by scanning electron microscopy (SEM), and by transmission electron microscopy (TEM). Some interesting structural features were found inside and outside of the melanosomes. By SEM observation, the melanosomes were ellipsoid shape, their surface was not smooth and was covered with rough substructure, 10 to 20 nm particles. By TEM, uneven structure and micro particles were observed in the melanosomes. Furthermore, three-dimensional analysis was tried by using the ultra-high voltage electron microscopy(UHVEM). Micrographs of the melanosomes were taken at various tilted angles by UHVEM, after preparing 500 nm thickness specimens stained with lead citrate. From the micrographs collected, the three-dimensional structures were reconstructed by using i-mode software. Melanin stained by lead and non stained parts was clearly observed in the reconstructed structure. Non stained parts were round, regular size, and distributed widely in the melanosomes. 展开更多
关键词 B16 MELANOMA MELANOSOME Scanning ELECTRON MICROSCOPY Transmission ELECTRON MICROSCOPY ultra high voltage ELECTRON MICROSCOPY Three-Dimensional Structure
下载PDF
Repeated Strike Process During Disconnector Operation in Ultra-High Voltage Gas-Insulated Switchgear 被引量:1
4
作者 关永刚 蔡元纪 +4 位作者 陈维江 刘卫东 李志兵 岳功昌 张俊民 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第3期247-253,共7页
Very fast transient over-voltage (VFTO), induced by disconnector operations in gas- insulated switchgears, has become the limiting dielectric stress at ultra-high voltage levels. Much work has been done to investiga... Very fast transient over-voltage (VFTO), induced by disconnector operations in gas- insulated switchgears, has become the limiting dielectric stress at ultra-high voltage levels. Much work has been done to investigate single-strike waveforms of VFTO. However, little study has been carried out investigating the repeated strike process, which would influence VFTO significantly. In this paper, we carried out 450 effective experiments in an ultra-high voltage test circuit, and conducted calculations through the Monte Carlo simulation method, to investigate the repeated strike process. Firstly, the mechanism of the repeated strike process is proposed, based on the ex- perimentai results. Afterwards, statistical breakdown characteristics of disconnectors are obtained and analyzed. Finally, simulations of the repeated strike process are conducted, which indicate that the dielectric strength recovery speed and polarity effect factor have a joint effect on VFTO. This study enhances the understanding of the nature of VFTO, and may help to optimize the disconnector designed to minimize VFTO. 展开更多
关键词 disconnector (DS) repeated strike process DISCHARGE statistical breakdowncharacteristics ultra-high voltage uhv very fast transient over-voltage (VFTO)
下载PDF
基于自适应协调触发量的UHVDC分层接入系统同时换相失败抑制策略
5
作者 夏莉涵 刘健 +1 位作者 林圣 赵静波 《电网技术》 EI CSCD 北大核心 2024年第9期3903-3911,I0094,共10页
特高压直流分层接入方式下,非故障层换相失败预测控制存在启动滞后、输出的提前触发量偏小等问题,系统面临同时换相失败风险。为解决该问题,提出一种基于自适应协调触发量的特高压直流分层接入方式下换相失败抑制策略,将故障层换相失败... 特高压直流分层接入方式下,非故障层换相失败预测控制存在启动滞后、输出的提前触发量偏小等问题,系统面临同时换相失败风险。为解决该问题,提出一种基于自适应协调触发量的特高压直流分层接入方式下换相失败抑制策略,将故障层换相失败预测控制输出的触发角调节量引入到非故障层,从而使非故障层换相失败预测控制提前触发。同时,引入联络线两端电压变化量来动态跟踪故障演变过程,以获得自适应协调触发量。在PSCAD/EMTDC中搭建电磁暂态仿真模型进行仿真验证,结果表明,所提抑制策略能够有效降低分层接入方式下高低端换流阀同时换相失败风险。 展开更多
关键词 特高压直流输电 分层接入 同时换相失败 换相失败预测控制 自适应协调触发量
下载PDF
Influencing Factors of the Power Fluctuation on the Ultra High Voltage Transmission Line Caused by Faults at the Remote Ends of the Interconnected Grid
6
作者 Zhi An Ansi Wang +1 位作者 Huadong Sun Yong Tang 《Journal of Power and Energy Engineering》 2014年第4期624-631,共8页
After the North China grid and the Central China grid get into connection with the UHVAC demonstration, a new phenomenon is discovered according to some simulations. That is, the faults at the remote end of the UHV in... After the North China grid and the Central China grid get into connection with the UHVAC demonstration, a new phenomenon is discovered according to some simulations. That is, the faults at the remote end of the UHV interconnected grid will result in significant power fluctuation and voltage drop on the UHV transmission line and even system splitting. But the faults near the UHV line only have marginal effects. Further, the simulation results also indicate that the short-circuit current of the buses near the UHV line is larger than that of the buses far away from the UHV line. This phenomenon is divergent from the traditional view. In this paper, the detail will be introduced, and the factors influencing the system stability after faults are presented and analyzed. The results indicate that transmission power of the UHV line and of the lines between the remote end and the major grid influence the fluctuation on UHV line. The load model and the grid structure of the remote end also have effect on it. Finally, corresponding control scheme is presented to improve the operation conditions of the UHV interconnected grid and ensure its security and stability. 展开更多
关键词 ultra high voltage uhv Interconnected GRID FAULTS at REMOTE End Power FLUCTUATION
下载PDF
Reliability of High Speed Ultra Low Voltage Differential CMOS Logic
7
作者 Omid Mirmotahari Yngvar Berg 《Circuits and Systems》 2015年第5期121-135,共15页
In this paper, we present a solution to the ultra low voltage inverter by adding a keeper transistor in order to make the semi-floating-gate more stable and to reduce the current dissipation. Moreover, we also present... In this paper, we present a solution to the ultra low voltage inverter by adding a keeper transistor in order to make the semi-floating-gate more stable and to reduce the current dissipation. Moreover, we also present a differential ULV inverter and elaborate on the reliability and fault tolerance of the gate. The differential ULV gate compared to both a former ULV gate and standard CMOS are given. The results are obtained through Monte-Carlo simulations. 展开更多
关键词 CMOS DIFFERENTIAL FLOATING-GATE Semi-Floating-Gate KEEPER RECHARGE ultra Low voltage high Speed Monte-Carlo CADENCE STM 90 nm
下载PDF
Fault simulation in ultrahigh voltage substation
8
作者 戴陶珍 孟亮亮 +1 位作者 崔彦平 马振 《Journal of Measurement Science and Instrumentation》 CAS 2012年第1期31-33,共3页
Ultrahigh voltage(UHV)and extra-high voltage(EHV)have been widely used in power system,so the requirement for technology of operation management,as well as the accident analysis and disposal are more pressing.Based on... Ultrahigh voltage(UHV)and extra-high voltage(EHV)have been widely used in power system,so the requirement for technology of operation management,as well as the accident analysis and disposal are more pressing.Based on the theory of Newton-Laphson power flow method,this simulation system imitates the primary device and secondary circuit,together with the normal,the abnormal and accidents in operation.Through simulation in various situations,it validates that this design is capable of simulating the complicated faults in UHV and EHV accurately and in real time.In addition,it can analyse and dispose them efficiently. 展开更多
关键词 ultrahigh voltage(uhv) extra-high voltage(EHV) fault simulation
下载PDF
Radio Interference Characteristic of Ultra-high Voltage AC Transmission Lines by Using Stochastic Modeling
9
作者 HE Wangling WAN Baoquan +3 位作者 PEI Chunming ZHANG Jiangong HE Junjia GUO Haozhou 《高电压技术》 EI CAS CSCD 北大核心 2013年第10期2438-2444,共7页
For developing ultra-high voltage(UHV) AC power transmission systems,it is important to precisely estimate and to limit the radio interference(RI) level of power lines.Based on the stochastic characteristics in amplit... For developing ultra-high voltage(UHV) AC power transmission systems,it is important to precisely estimate and to limit the radio interference(RI) level of power lines.Based on the stochastic characteristics in amplitude and repetition rate of induced corona current,by using the probability theory and mathematical statistics,we establish a stochastic model for the wide-sense stationary random process of corona discharges.Then combining the stochastic model with model-propagation-analysis method,the RI levels under three-phase UHV AC transmission lines are calculated.The results of the calculation based on stochastic model method and International Council on Large Electric Systems(CIGRE) excitation function are compared with that based on semi-empirical method and some other excitation functions.The stochastic model based on different excitation functions is also adopted to simulate the RI levels under finite test lines with two opened terminations.The results indicate that with the same average maximum gradient on conductor surface and the same conductor type,the number of corona discharge per unit length is one of the main reasons that causes the difference between different excitation functions.It is also concluded that for a long test line,the effect of standing wave on RI field strength is negligible in the middle of the line,but obvious near both terminations: for a 10-km line,the maximum difference in RI field strength is 2.78 dB,between the peak value of the standing wave near the ends and the steady value near the middle of the line. 展开更多
关键词 特高压输电线路 交流输电线路 无线电干扰 随机建模 干扰特性 概率论与数理统计 电力传输系统 平稳随机过程
下载PDF
Switching Impulse Strength of ±800 kV UHVDC Transmission Line Air Gap Insulation Under High Altitude Condition 被引量:3
10
作者 LIAO Yongli GAO Chao +2 位作者 LI Ruihai WANG Guoli MA Yi 《高电压技术》 EI CAS CSCD 北大核心 2012年第12期3161-3165,共5页
关键词 高压直流输电线路 缺口冲击强度 空气间隙 绝缘特性 开关脉冲 高海拔 伏特 平面布置
下载PDF
Influence Factors of Audible Noise Caused by Corona Discharge on UHVDC Transmission Lines Under High Altitude Condition 被引量:4
11
作者 TIAN Feng YU Zhanqing +3 位作者 ZENG Rong LIU Lei LI Min LI Ruihai 《高电压技术》 EI CAS CSCD 北大核心 2012年第12期3125-3132,共8页
关键词 高压直流输电线路 电晕放电 影响因素 噪声 高海拔 高压直流输电工程 绝对湿度 电压升高
下载PDF
Calculation and Analysis of Switching Overvoltage Front Time and Switching Impulse Insulation Coordination for UHV AC Transmission Line of Chinese Pilot Project and Double-circuit Project 被引量:2
12
作者 ZHOU Peihong HE Huiwen 《高电压技术》 EI CAS CSCD 北大核心 2014年第6期1781-1794,共14页
关键词 特高压交流输电 交流输电线路 中国国家标准 操作过电压 软件计算 时间脉冲 试点项目 绝缘配合
下载PDF
Overvoltage and Insulation Coordination of Jinping-Sunan ±800 kV UHVDC Porject Converter Stations 被引量:2
13
作者 YU Shifeng NIE Dingzhen MA Weimin TONG Yuliang 《高电压技术》 EI CAS CSCD 北大核心 2012年第12期3219-3223,共5页
关键词 过电压保护 绝缘配合 特高压直流输电 换流站 苏南 高压直流输电系统 高压直流输电工程 设备制造
下载PDF
特高压并联电抗器铁芯振动及噪声特征研究 被引量:3
14
作者 杨帆 张相杰 +3 位作者 王鹏博 罗汉武 李昉 李文震 《高电压技术》 EI CAS CSCD 北大核心 2024年第2期725-736,共12页
特高压并联电抗器因其铁芯是以铁芯饼与气隙垫块交替堆叠而成的结构特点,导致其运行过程中振动强度远超同电压等级的变压器,易出现振动超标等问题,现有计算方法对特高压并联电抗器铁芯振动特征还无法准确表征。鉴于此,该文针对1台特高... 特高压并联电抗器因其铁芯是以铁芯饼与气隙垫块交替堆叠而成的结构特点,导致其运行过程中振动强度远超同电压等级的变压器,易出现振动超标等问题,现有计算方法对特高压并联电抗器铁芯振动特征还无法准确表征。鉴于此,该文针对1台特高压并联电抗器的铁芯振动机理及产生的噪声进行研究,结合磁-结构-声多场耦合分析,对铁芯所受麦克斯韦力及磁致伸缩力进行仿真计算,将结构场计算结果进行快速傅里叶变换后作为载荷激励进而计算由电抗器振动产生的噪声,并单独分析磁致伸缩力和麦克斯韦力对电抗器铁芯振动造成的影响。结果表明:电抗器运行过程中电抗器铁芯旁轭中部产生的振动最剧烈,电抗器周围产生的噪声最大。对比麦克斯韦力与磁致伸缩力对电抗器铁芯振动的影响发现,同时考虑两个力时铁芯振动小于未考虑磁致伸缩力的情况,证明影响电抗器铁芯振动的两个力存在相互衰减作用。 展开更多
关键词 特高压并联电抗器 多物理场耦合计算 振动噪声 磁致伸缩 麦克斯韦力
下载PDF
断路器选相投切系统在换流站中的应用研究
15
作者 李海涛 董辉波 +3 位作者 邓劲东 程骁 刘东超 须雷 《自动化仪表》 CAS 2024年第9期121-126,共6页
在换流站滤波器组及换流变压器配置断路器选相投切系统,可改善断路器开合暂态过程,在取消合闸电阻工况下仍可避免对电力设备及系统造成冲击。基于多个换流站选相投切工程实施及调试经验,进行了换流站选相投切系统应用的调查。介绍了选... 在换流站滤波器组及换流变压器配置断路器选相投切系统,可改善断路器开合暂态过程,在取消合闸电阻工况下仍可避免对电力设备及系统造成冲击。基于多个换流站选相投切工程实施及调试经验,进行了换流站选相投切系统应用的调查。介绍了选相投切系统构成、选相投切要求、断路器配套及预测试方法等。重点针对滤波器组、换流变压器的选相投切应用,总结了控制策略、选相投切系统带电冲击试验,及工程使用中需重点关注的问题、设备运维要求等,为相关技术人员提供参考。试点工程在特高压断路器中创新性地采用取消合闸电阻、增设选相合闸的专项改造方案。断路器选相投切系统总体运行效果良好,为技术的推广积累了工程运行经验。 展开更多
关键词 换流站 滤波器 换流变压器 高压/特高压直流输电 暂态冲击 选相投切
下载PDF
航天器太阳电池阵驱动装置技术发展与展望
16
作者 于国庆 刘艳敏 +1 位作者 张猛 张可 《空间控制技术与应用》 CSCD 北大核心 2024年第5期17-25,共9页
太阳电池阵驱动装置是三轴稳定卫星上的关键单机,驱动太阳翼对日定向并向整星传输电功率,在卫星寿命期间持续工作,其可靠性和寿命直接影响整星寿命.从20世纪60年代至今,经过几十年的发展,在传输功率、在轨寿命、功率传输可靠性和低扰动... 太阳电池阵驱动装置是三轴稳定卫星上的关键单机,驱动太阳翼对日定向并向整星传输电功率,在卫星寿命期间持续工作,其可靠性和寿命直接影响整星寿命.从20世纪60年代至今,经过几十年的发展,在传输功率、在轨寿命、功率传输可靠性和低扰动特性等方面获得了长足的进步.近年来,随着低轨卫星星座和商业航天的发展,低成本、轻小型和双轴SADA类产品需求旺盛.本文根据国内外相关领域的信息和资料,总结了其技术发展情况和型号应用特点,并提出了超高压大功率技术方向、低成本双轴SADA的商业航天应用方向是未来的主要发展方向. 展开更多
关键词 太阳电池阵驱动装置 高压大功率 低成本 发展方向 综述
下载PDF
钢管输电塔挂线节点足尺模型失效模式与承载力提升分析
17
作者 翟彬 李素超 +3 位作者 张丽娟 徐再根 王志远 毛晨曦 《地震研究》 CSCD 北大核心 2024年第1期1-9,共9页
针对特高压钢管输电塔挂线位置节点在极端荷载下的安全性,提出了挂线节点双侧挂线板协同受力的构造改进措施,并对比研究两种挂线节点的极限承载力与失效模式。通过足尺挂线节点处的承载力试验与有限元分析,比较挂线节点在单侧板受力、... 针对特高压钢管输电塔挂线位置节点在极端荷载下的安全性,提出了挂线节点双侧挂线板协同受力的构造改进措施,并对比研究两种挂线节点的极限承载力与失效模式。通过足尺挂线节点处的承载力试验与有限元分析,比较挂线节点在单侧板受力、双侧板受力情况下的应力分布与承载能力,分析传力螺母与挂线板之间的合理初始间距。结果表明:双侧受力时两侧挂线板均发生弯曲破坏,受力形式更加合理,节点板应力分布更加均匀,挂线点的屈服承载力可以提升一倍以上,传力螺母与挂线板之间的合理初始间隙为2~4 mm。 展开更多
关键词 特高压输电塔 挂线节点 承载力 足尺试验 有限元模拟 传力螺母
下载PDF
不同风场中特高压换流站阀厅屋盖风压特性试验研究
18
作者 汪之松 王宇杰 +3 位作者 余波 徐晴 何勇 李正良 《振动与冲击》 EI CSCD 北大核心 2024年第2期146-155,共10页
特高压(ultra high voltage,UHV)换流站阀厅的金属屋面系统在风荷载作用下易发生屋面表层风揭事故。为深入探讨该类建筑屋面的风压极值特性,基于风洞试验分别探讨了大气边界层(atmospheric-boundary-layer,ABL)风、壁面射流、均匀湍流... 特高压(ultra high voltage,UHV)换流站阀厅的金属屋面系统在风荷载作用下易发生屋面表层风揭事故。为深入探讨该类建筑屋面的风压极值特性,基于风洞试验分别探讨了大气边界层(atmospheric-boundary-layer,ABL)风、壁面射流、均匀湍流三种风场作用下的屋面风压特性,比较了平均风剖面、风速、风向、湍流强度等因素对屋面风压的影响。结果表明:阀厅屋盖迎风前缘负风压最大,且控制风向角在45°左右;壁面射流风场下平均风压系数与脉动风压系数均超过大气边界层风场的结果;风速对阀厅屋盖的负风压系数均值和极值影响较小,而湍流度对风压系数的极值影响较大;大气边界风场时,JGJ/T 481—2019《屋盖结构风荷载标准》的最不利风压系数建议值偏于安全;而在壁面射流风场下,阀厅屋盖全风向最不利风压系数在所有区域都大于JGJ/T 481—2019的建议值,设计中应加以重视。 展开更多
关键词 特高压(uhv)换流站阀厅屋盖 大气边界层(ABL)风 壁面射流 均匀湍流 极值风压系数
下载PDF
级联多端特高压直流控制保护系统配置及策略
19
作者 张庆武 徐莹 +3 位作者 沈天骄 高子健 肖建民 唐俊 《电网技术》 EI CSCD 北大核心 2024年第4期1799-1807,I0104,共10页
该文针对金上直流工程主回路拓扑结构与运行方式的特点,设计了送端分址级联多端特高压直流控制保护系统的配置方案;提出送端分站的高、低压换流器的电压平衡控制方案,根据送端两站间通信条件,切换采用附加电压平衡控制的触发角协调控制... 该文针对金上直流工程主回路拓扑结构与运行方式的特点,设计了送端分址级联多端特高压直流控制保护系统的配置方案;提出送端分站的高、低压换流器的电压平衡控制方案,根据送端两站间通信条件,切换采用附加电压平衡控制的触发角协调控制和串联两换流器一个定电压、另一个定电流的控制策略;基于送端分站级联拓扑,研究了其直流保护功能配置方案,并提出针对送端站1内的极区/换流器区故障或者送端两站之间直流线路永久故障的快速清除方法。基于控制保护工程样机的RTDS闭环仿真结果表明,该级联多端特高压直流控制保护系统可以满足实际工程应用的要求。 展开更多
关键词 特高压直流输电 级联多端特高压直流 送端级联直流 控制保护系统 功能配置
下载PDF
混合级联特高压直流功率损失计算方法研究
20
作者 刘凯 赵文强 +1 位作者 侍乔明 王永平 《电力电子技术》 2024年第6期50-53,60,共5页
混合级联特高压直流(UHVDC)在降低直流换相失败风险的同时提升了直流输电的灵活性,但由于LCC与VSC混合拓扑导致不同阀组闭锁后健全阀组的功率传输能力存在不确定性,影响了直流功率损失准确计算。此处提出了一种适用于混合级联UHVDC的功... 混合级联特高压直流(UHVDC)在降低直流换相失败风险的同时提升了直流输电的灵活性,但由于LCC与VSC混合拓扑导致不同阀组闭锁后健全阀组的功率传输能力存在不确定性,影响了直流功率损失准确计算。此处提出了一种适用于混合级联UHVDC的功率损失计算方法。直流控制系统以极为单位计算阀组闭锁后的直流功率并发送安控系统计算直流功率损失,设计了合理接口与数据处理方式保证阀组单次及相继故障直流功率损失计算的准确性。最后通过试验,验证了所提方法的正确性与有效性。 展开更多
关键词 混合级联特高压直流 功率损失计算 控制系统
下载PDF
上一页 1 2 90 下一页 到第
使用帮助 返回顶部