[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical c...[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical components of A. bidentata leaves were rapidly analyzed using the ultra high performance liquid chromatography-time of flight-high resolution mass spectrometry (UHPLC-TOF-MS).[Results] Thirty eight chemical compounds were identified in samples of A. bidentata leaves collected from Wen County of Henan Province, in which seven chemical compounds had the relative content higher than 5%, linoleic acid reached 25.7% and inokosterone A reached 13.8%.[Conclusions] A. bidentata leaves contain many kinds of chemical compounds. This study is expected to provide a certain basis for further extraction of linoleic acid and inokosterone A.展开更多
This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile sampl...This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles.展开更多
Introduction: Conventional metabolite analyses often require manual sample preparation, generating variability of measurements. This study describes a new method to quantify radiometabolites in blood, combining ultra ...Introduction: Conventional metabolite analyses often require manual sample preparation, generating variability of measurements. This study describes a new method to quantify radiometabolites in blood, combining ultra high performance liquid chromatography (UHPLC) and turbulent flow chromatography, an alternative fully automated process allowing analyte’s extraction. Methods: A new radiotracer for dopamine transporter imaging, namely LBT-999, was used to demonstrate the method’s robustness. Matrix effect, Turboflow column loading, linearity, specificity and precision were evaluated with in vitro samples of LBT-999 in human plasma. Radiodetector sensitivity and preliminary evaluation were respectively determined by analysis of calibrated samples of [18F]LBT-999 and blood samples from 4 healthy subjects injected with [18F]LBT-999, withdrawn at 5, 15, 30 and 45 min pi. Results: With three sequential loadings (3 × 100 μL) of the Turboflow column, mean coefficients of variation were 1%, below 2%, 2% and 30.9% for matrix effect, specificity, repeatability and intermediate precision, respectively. Correlation coefficients for linearity were superior to 0.97. Limits of detection and quantification of the radiodetector were fixed at 3 and 9 c/s. Retention times for [18F]LBT-999 and the two radiometabolites detected by radio-UHPLC were 6.5, 4.8 and 9.6 min. Forty-five min after the injection, parent fraction was still predominant with 57.8% ± 25% of the total radioactivity. Conclusions: An innovative approach, allying UHPLC and Turboflow column, was developed and its sensitivity, linearity, specificity and repeatability validated. Preliminary results of the clinical trial are in accordance with literature data, demonstrating its efficiency in radiometabolites quantification.展开更多
Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC...Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine.展开更多
A simultaneous method was successfully established and validated for the separation and determination of bu- prenorphine (BP), its primary metabolite, nor-buprenorphine (NBP) and a proposed co-formulate, naloxone ...A simultaneous method was successfully established and validated for the separation and determination of bu- prenorphine (BP), its primary metabolite, nor-buprenorphine (NBP) and a proposed co-formulate, naloxone (NLX) in human plasma. The method used buprenorphine-d4 (BP-D4), nor-buprenorphine-d3 (NBP-D3), naltrexone (NTX) as internal standards (ISs). 100 μL of plasma sample fortified with the ISs was cleaned up by solid-phase extraction (SPE), and was then separated on a Waters AcquityTM BEH C18 column with gradient elution using methanol and water (containing 0.2% formic) at a flow rate of 0.25 mL·min^-1. The mass spectrometer was used for detection and was operated in the positive electrospray ionization with multiple reaction monitoring (MRM) mode. The three compounds were effectively separated in 5 min. The linear ranges of the compounds were 0.1--25, 0.25--25 and 0.05--25 ng·mL^-1 for BP, NBP and NLX, respectively, with r≥0.9935. The method had high sensitivity (the lim- its of detection were 0.02, 0.1 and 0.01 ng.mL-1 for BP, NBP and NLX, respectively) and high recoveries (≥97.6%). The result was shown to be linear and satisfactorily met current acceptance criteria for validation of bio- analytical method: intra and inter assay precisions within the required limits of ≤25% RSD. The LOQs fulfilled the LOQ requirements: precision≤25% RSD, and was fully validated according to the State Food and Drug Administration (SFDA) regulations. The results demonstrated that ultra-high performance liquid chromatography- tandem mass spectrometer (UPLC-MS/MS) with SPE was a powerful detection tool and contributed to pharmaceutical analysis in biological matrices.展开更多
为探究‘福红’李冷藏过程中初生代谢物组成及动态变化规律,采用超高效液相色谱-串联质谱技术分析3个冷藏阶段果肉初生代谢谱。将‘福红’李置于4℃贮藏,分别于0、30 d和60 d采集果肉样本,采用超高效液相色谱-串联质谱技术进行定性分析...为探究‘福红’李冷藏过程中初生代谢物组成及动态变化规律,采用超高效液相色谱-串联质谱技术分析3个冷藏阶段果肉初生代谢谱。将‘福红’李置于4℃贮藏,分别于0、30 d和60 d采集果肉样本,采用超高效液相色谱-串联质谱技术进行定性分析,采用正交偏最小二乘判别分析等方法筛选差异代谢物,并对差异代谢物进行通路富集分析。结果显示,从‘福红’李果肉中共检测出糖类、有机酸、氨基酸及其衍生物、脂质和核苷酸等573种代谢物。不同冷藏期间‘福红’李果肉代谢物差异显著,其中,30 d vs 0 d存在95种差异代谢物,60 d vs 30 d存在99种差异代谢物,60 d vs 0 d存在173种差异代谢物。通路富集分析显示,‘福红’李冷藏期间亚油酸代谢、不饱和脂肪酸的生物合成、丙酸代谢、硫代谢、嘌呤代谢、核苷酸代谢及半胱氨酸和蛋氨酸代谢等主要代谢通路差异显著。本研究揭示了不同冷藏期间‘福红’李果肉初生代谢物变化规律,可为‘福红’李果实品质评价与采后贮藏研究提供重要理论参考。展开更多
目的比较江西特色炮制技术对升麻化学成分的影响,筛选优质饮片品种。方法采用超高效液相色谱-四极杆-飞行时间串联质谱(ultra performance liquid chromatography-quadrupole-time of flight tandem mass spectrometry,UPLC-Q-TOF-MS)技...目的比较江西特色炮制技术对升麻化学成分的影响,筛选优质饮片品种。方法采用超高效液相色谱-四极杆-飞行时间串联质谱(ultra performance liquid chromatography-quadrupole-time of flight tandem mass spectrometry,UPLC-Q-TOF-MS)技术,在正、负离子模式下分析升麻不同炮制品的化学成分,通过对照品、相对分子质量、质谱裂解规律和文献信息进行鉴定。利用SIMCA-P13.0软件建立升麻各炮制品主成分分析(principal component analysis,PCA)和偏最小二乘法-判别分析(partial least squares discriminant analysis,PLS-DA)模型,获取PCA得分图、PLA-DA得分图和变量重要性投影(variable importance plot,VIP)值,筛选造成升麻炮制前后主要差异的物质基础。利用MetaboAnatyst网页绘图工具,制作得到热图,可更直观地观察升麻化学成分经炮制后的变化趋势。结果鉴定出71个化学成分,PCA显示经不同方法炮制后升麻组间差异性大,PLS-DA筛选出VIP值>1的33个化学成分作为炮制前后差异性的主要化学标记物。其中生品和蜜炙升麻中三萜类含量较高,蜜麸、蜜糠炒升麻中酚酸类物质含量较高,蜜麸升麻中阿魏酸含量较高。结论酚酸类和三萜皂苷类是区分升麻不同炮制品最重要的化合物类别,为江西特色升麻饮片的药效物质基础及优势品种研究提供了依据。展开更多
[目的]建立同时检测配合饲料中64种药物的超高效液相色谱-三重四极杆串联质谱(ultra-high performance liquid chromatography-triple quadrupole tandem mass spectrometry,UHPLC-MS/MS)法,提高非法添加物的检测效率。[方法]采用Waters...[目的]建立同时检测配合饲料中64种药物的超高效液相色谱-三重四极杆串联质谱(ultra-high performance liquid chromatography-triple quadrupole tandem mass spectrometry,UHPLC-MS/MS)法,提高非法添加物的检测效率。[方法]采用Waters HSS T3型色谱柱(2.1 mm×100 mm,1.8μm)进行分离,流动相A为0.1%甲酸水溶液,流动相B为含0.1%甲酸的乙腈溶液,梯度洗脱,流速为0.40 mL/min,进样量为2μL;采用电喷雾离子源正离子扫描模式进行检测,多反应监测模式进行信号采集。比较4种样品提取溶剂以及2种固相萃取柱处理对目标药物的回收率,确定样品前处理的最佳方法。利用建立的UHPLC-MS/MS法对宁夏回族自治区不同来源的100批次配合饲料样品进行64种药物检测。[结果]配合饲料样品均质后,用含0.2%甲酸的乙腈水溶液(乙腈∶水=8∶2,V/V)提取,利用Oasis PRiME HLB型固相萃取柱对样品净化,多数目标药物的回收率在60%以上。64种药物在浓度为5.0~200.0μg/L的范围内线性关系良好,相关系数(R)均大于0.99;不同药物的定量限在5.0~10.0μg/kg;阳性添加5.0、20.0、50.0μg/kg 3个浓度的平均回收率在41.00%~120.49%,批内相对标准偏差(RSD)在0.54%~15.94%,批间RSD在1.25%~13.64%。在100个批次的配合饲料样品中均未检出目标药物。[结论]建立的UHPLC-MS/MS法线性关系良好、回收率高、精密度好,具有较高的重现性和较好的可操作性,可用于配合饲料中非法添加64种药物的筛查。展开更多
基金Supported by Key Scientific and Technological Research Project in Higher Education Institutions of Henan Province(17A350002)Project of National Natural Science Foundation of China(81172953)
文摘[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical components of A. bidentata leaves were rapidly analyzed using the ultra high performance liquid chromatography-time of flight-high resolution mass spectrometry (UHPLC-TOF-MS).[Results] Thirty eight chemical compounds were identified in samples of A. bidentata leaves collected from Wen County of Henan Province, in which seven chemical compounds had the relative content higher than 5%, linoleic acid reached 25.7% and inokosterone A reached 13.8%.[Conclusions] A. bidentata leaves contain many kinds of chemical compounds. This study is expected to provide a certain basis for further extraction of linoleic acid and inokosterone A.
文摘This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles.
文摘Introduction: Conventional metabolite analyses often require manual sample preparation, generating variability of measurements. This study describes a new method to quantify radiometabolites in blood, combining ultra high performance liquid chromatography (UHPLC) and turbulent flow chromatography, an alternative fully automated process allowing analyte’s extraction. Methods: A new radiotracer for dopamine transporter imaging, namely LBT-999, was used to demonstrate the method’s robustness. Matrix effect, Turboflow column loading, linearity, specificity and precision were evaluated with in vitro samples of LBT-999 in human plasma. Radiodetector sensitivity and preliminary evaluation were respectively determined by analysis of calibrated samples of [18F]LBT-999 and blood samples from 4 healthy subjects injected with [18F]LBT-999, withdrawn at 5, 15, 30 and 45 min pi. Results: With three sequential loadings (3 × 100 μL) of the Turboflow column, mean coefficients of variation were 1%, below 2%, 2% and 30.9% for matrix effect, specificity, repeatability and intermediate precision, respectively. Correlation coefficients for linearity were superior to 0.97. Limits of detection and quantification of the radiodetector were fixed at 3 and 9 c/s. Retention times for [18F]LBT-999 and the two radiometabolites detected by radio-UHPLC were 6.5, 4.8 and 9.6 min. Forty-five min after the injection, parent fraction was still predominant with 57.8% ± 25% of the total radioactivity. Conclusions: An innovative approach, allying UHPLC and Turboflow column, was developed and its sensitivity, linearity, specificity and repeatability validated. Preliminary results of the clinical trial are in accordance with literature data, demonstrating its efficiency in radiometabolites quantification.
文摘Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine.
文摘A simultaneous method was successfully established and validated for the separation and determination of bu- prenorphine (BP), its primary metabolite, nor-buprenorphine (NBP) and a proposed co-formulate, naloxone (NLX) in human plasma. The method used buprenorphine-d4 (BP-D4), nor-buprenorphine-d3 (NBP-D3), naltrexone (NTX) as internal standards (ISs). 100 μL of plasma sample fortified with the ISs was cleaned up by solid-phase extraction (SPE), and was then separated on a Waters AcquityTM BEH C18 column with gradient elution using methanol and water (containing 0.2% formic) at a flow rate of 0.25 mL·min^-1. The mass spectrometer was used for detection and was operated in the positive electrospray ionization with multiple reaction monitoring (MRM) mode. The three compounds were effectively separated in 5 min. The linear ranges of the compounds were 0.1--25, 0.25--25 and 0.05--25 ng·mL^-1 for BP, NBP and NLX, respectively, with r≥0.9935. The method had high sensitivity (the lim- its of detection were 0.02, 0.1 and 0.01 ng.mL-1 for BP, NBP and NLX, respectively) and high recoveries (≥97.6%). The result was shown to be linear and satisfactorily met current acceptance criteria for validation of bio- analytical method: intra and inter assay precisions within the required limits of ≤25% RSD. The LOQs fulfilled the LOQ requirements: precision≤25% RSD, and was fully validated according to the State Food and Drug Administration (SFDA) regulations. The results demonstrated that ultra-high performance liquid chromatography- tandem mass spectrometer (UPLC-MS/MS) with SPE was a powerful detection tool and contributed to pharmaceutical analysis in biological matrices.
文摘为探究‘福红’李冷藏过程中初生代谢物组成及动态变化规律,采用超高效液相色谱-串联质谱技术分析3个冷藏阶段果肉初生代谢谱。将‘福红’李置于4℃贮藏,分别于0、30 d和60 d采集果肉样本,采用超高效液相色谱-串联质谱技术进行定性分析,采用正交偏最小二乘判别分析等方法筛选差异代谢物,并对差异代谢物进行通路富集分析。结果显示,从‘福红’李果肉中共检测出糖类、有机酸、氨基酸及其衍生物、脂质和核苷酸等573种代谢物。不同冷藏期间‘福红’李果肉代谢物差异显著,其中,30 d vs 0 d存在95种差异代谢物,60 d vs 30 d存在99种差异代谢物,60 d vs 0 d存在173种差异代谢物。通路富集分析显示,‘福红’李冷藏期间亚油酸代谢、不饱和脂肪酸的生物合成、丙酸代谢、硫代谢、嘌呤代谢、核苷酸代谢及半胱氨酸和蛋氨酸代谢等主要代谢通路差异显著。本研究揭示了不同冷藏期间‘福红’李果肉初生代谢物变化规律,可为‘福红’李果实品质评价与采后贮藏研究提供重要理论参考。
文摘目的比较江西特色炮制技术对升麻化学成分的影响,筛选优质饮片品种。方法采用超高效液相色谱-四极杆-飞行时间串联质谱(ultra performance liquid chromatography-quadrupole-time of flight tandem mass spectrometry,UPLC-Q-TOF-MS)技术,在正、负离子模式下分析升麻不同炮制品的化学成分,通过对照品、相对分子质量、质谱裂解规律和文献信息进行鉴定。利用SIMCA-P13.0软件建立升麻各炮制品主成分分析(principal component analysis,PCA)和偏最小二乘法-判别分析(partial least squares discriminant analysis,PLS-DA)模型,获取PCA得分图、PLA-DA得分图和变量重要性投影(variable importance plot,VIP)值,筛选造成升麻炮制前后主要差异的物质基础。利用MetaboAnatyst网页绘图工具,制作得到热图,可更直观地观察升麻化学成分经炮制后的变化趋势。结果鉴定出71个化学成分,PCA显示经不同方法炮制后升麻组间差异性大,PLS-DA筛选出VIP值>1的33个化学成分作为炮制前后差异性的主要化学标记物。其中生品和蜜炙升麻中三萜类含量较高,蜜麸、蜜糠炒升麻中酚酸类物质含量较高,蜜麸升麻中阿魏酸含量较高。结论酚酸类和三萜皂苷类是区分升麻不同炮制品最重要的化合物类别,为江西特色升麻饮片的药效物质基础及优势品种研究提供了依据。