期刊文献+
共找到6,069篇文章
< 1 2 250 >
每页显示 20 50 100
Determination of Oleuropein in Cosmetics by Ultra Performance Liquid Chromatography-Triple Quadrupole Tandem Mass Spectrometry
1
作者 Pan Lijing Chen Weiwei Yuan Minjia 《China Detergent & Cosmetics》 CAS 2023年第4期30-36,共7页
An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracte... An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics. 展开更多
关键词 ultra performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS) OLEUROPEIN COSMETICS
下载PDF
Determination of thyreostats in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry
2
作者 Lech RODZIEWICZ Jolanta MASLOWIECKA +1 位作者 Anna SADOWSKA Halina CAR 《色谱》 CAS CSCD 北大核心 2017年第10期1048-1054,共7页
Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC... Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine. 展开更多
关键词 ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) thyreostats (TSs) URINE
下载PDF
Uncertainty Evaluation of Determination of Microcystin MC-LR in Environmental Samples by Solid Phase Extraction-Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry 被引量:1
3
作者 Zhao Bin Zhang Min Zhang Fuhai 《Meteorological and Environmental Research》 CAS 2016年第6期54-57,共4页
To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated first... To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2). 展开更多
关键词 Uncertainty SOLID phase extraction ultra performance liquid chromatography tandem mass spectrometry MICROCYSTIN MC-LR China
下载PDF
Chemical Components of Achyranthes bidentata Leaves by Ultra High Performance Liquid Chromatography-Mass Spectrometry 被引量:1
4
作者 Haiyang DONG Jinshuo MA Fulin YAN 《Medicinal Plant》 CAS 2019年第4期16-19,共4页
[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical c... [Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical components of A. bidentata leaves were rapidly analyzed using the ultra high performance liquid chromatography-time of flight-high resolution mass spectrometry (UHPLC-TOF-MS).[Results] Thirty eight chemical compounds were identified in samples of A. bidentata leaves collected from Wen County of Henan Province, in which seven chemical compounds had the relative content higher than 5%, linoleic acid reached 25.7% and inokosterone A reached 13.8%.[Conclusions] A. bidentata leaves contain many kinds of chemical compounds. This study is expected to provide a certain basis for further extraction of linoleic acid and inokosterone A. 展开更多
关键词 Achyranthes bidentata LEAVES ultra high performance liquid chromatography-mass spectrometry (UHPLC-MS) Chemical components Inokosterone
下载PDF
Simultaneous Determination of Ultraviolet Absorbers and Antibacterial Agents in Textiles by Ultra-High Performance Liquid Chromatography/Orbitrap High Resolution Mass Spectrometry 被引量:1
5
作者 Chengyun Wang Tangtang Xie +2 位作者 Rong Xu Junfeng Lin Lixia Li 《World Journal of Engineering and Technology》 2017年第1期1-18,共18页
This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile sampl... This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles. 展开更多
关键词 ultra-high performance liquid chromatography/Orbitrap high Resolution mass spectrometry Benzotriazoleultraviolet ABSORBERS Isothiazolinone Tric-losan 4-Chloro-3 5-Dimethyl Phenol
下载PDF
Modernization of Chinese herbal compound and the high performance liquid chromatography tandem mass spectrometry (HPLC-MS)
6
作者 LI Wen-lan1,2,3,SUN Zhi1,2,DU Juan1,2(1.Engineering Research Center of natural antineoplastic drugs,Ministry of Education,Harbin 150076,China 2.Center of Research and Development on Life Sciences and Environmental Sciences,Harbin University of Commerce,Harbin 150076,China 3.Institute of Materia Medica and Postdoctoral Programme of Harbin University of Commerce,Harbin 150076,China) 《沈阳药科大学学报》 CAS CSCD 北大核心 2008年第S1期119-119,共1页
Chinese herbal compound is playing an important role on curing human diseases.And it has been a trend that Chinese herbal compound is being used all over the world in 21 century.However,our Chinese herbal compound is ... Chinese herbal compound is playing an important role on curing human diseases.And it has been a trend that Chinese herbal compound is being used all over the world in 21 century.However,our Chinese herbal compound is facing serious challenge for the lack of canonical system of quality criterion for Chinese herbal compound so it has been a urgent problem to set up the quality control standards and reveal therapeutic basis of Chinese herbal compound.In order to give full play to the advantages of Chinese herbal compound,modern scientific and technological is used to research of Chinese herbal compound,especially the high performance liquid chromatography tandem mass spectrometry(HPLC-MS),because it is high sensitive,rapid,and obtain more information.It is very necessary that HPLC-MS is uesed to elucidate the effective components of basic substances of Chinese Herbal Compound,and endow traditional Chinese medicine with modern scientific connotation. 展开更多
关键词 MODERNIZATION of Chinese HERBAL compound the high performance liquid chromatography tandem mass spectrometry(HPLC-MS)
下载PDF
Rapid Determination of Three Kinds of Microcystins in Environmental Water Samples by Disk SPE-Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
7
作者 Zhao Bin Zhang Min Zhang Fuhai 《Meteorological and Environmental Research》 CAS 2016年第5期62-64,68,共4页
A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established.... A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples. 展开更多
关键词 Disk SOLID-PHASE extraction COLUMN ultra performance liquid chromatography-tandem mass spectrometry Environmental water sample MICROCYSTINS Lake Chao China
下载PDF
Determination of okadaic acid related toxins from shellfish (<i>sinonovacula constricta</i>) by high performance liquid chromatography tandem mass spectrometry
8
作者 Hai-qi Zhang Weicheng Liu +3 位作者 Xin He Li-jun Liang Wenyong Ding Zhong-yang He 《Agricultural Sciences》 2013年第5期1-6,共6页
Consumption of shellfish contaminated with algal toxins produced by marine dinoflagellates can lead to diarrhetic shellfish poisoning (DSP). It was therefore essential that there are analytical techniques to identify ... Consumption of shellfish contaminated with algal toxins produced by marine dinoflagellates can lead to diarrhetic shellfish poisoning (DSP). It was therefore essential that there are analytical techniques to identify and quantify DSP toxins in shellfish. This new methodology could facilitate DSP monitoring and create a means of rapidly responding to incidents threatening public health. In the last years there were different analytical methods for DSP, such as mouse bioassay and LC-FLD. With the development of instrument, Liquid chromatography-mass spectrometry was substituted for other analytical methods with its good sensitivity and selectivity and without derivatization for the determination of DSP. In this report, a high performance liquid chromatogra-phytandem mass spectrometric(HPLC-MS/MS)method was developed for the simultaneous determination of okadaic acid (OA) and dinophysistoxins(DTX1) in Sinonovacula constricta. Optimization of pretreatment experiment was carried out to maximize recoveries and the effectiveness. The analytes were determined under multi-reactions monitoring (MRM) scan type with tandem mass analyzer using negative ion electrospray ionization (-ESI) mode .Finally, the detection and identification of OA and DTX-1 were based upon their retention times (RT) and the fragmentation patterns of their mass spectra. The method of LOQ for the two poisons was 0.02 mg·kg-1.The real sample test showed that this method could be used for sensitive, fast, and accurate determination of the two diarrheic shellfish poisons in shellfish. 展开更多
关键词 Sinonovacula Constricta high performance liquid chromatography-tandem mass spectrometry Okadaic Acid Dinophysistoxins-1
下载PDF
Determination of 24 Allergens in Perfume with High Performance Liquid Chromatography Tandem Mass Spectrometry
9
作者 Wang Yujian Liang Zhengang +1 位作者 Fu Lingmei Dong Cunzhu 《China Detergent & Cosmetics》 2019年第1期40-46,共7页
A method of 24 allergens determination in cosmetics were established with high performance liquid chromatography tandem mass spectrometry. The targeted compounds were extracted with acetonitrile and determined with LC... A method of 24 allergens determination in cosmetics were established with high performance liquid chromatography tandem mass spectrometry. The targeted compounds were extracted with acetonitrile and determined with LC-MS/MS (MRM mode) with external method. The linearity between concentrations and peak area ratio was obtained from 1.0~5.0 mg/L. The limits of detection were 1.0 mg/L for the instrument and 5.0 mg/kg for the method respectively. The LOQ was 15.0 mg/L. The average recoveries of 24 allergens were between 85.9% and 110.0% at spiked levels of 5, 10 and 20 mg/kg with relative standard derivation (RSDs) of 5.5%~12.0%(n=10). The method could be used as a reliable means for simultaneous quantitative determination of allergens in cosmetics. 展开更多
关键词 PERFUME allergens FLAVOR high performance liquid chromatography tandem mass spectrometry
下载PDF
GLOBAL ANALYSIS OF THE METABOLITES OF CURCUMIN IN RATS BY ULTRA PERFORMANCE LIQUID CHROMATOGRAPHY COUPLED WITH QUADRUPOLE TIME OF-FLIGHT TANDEM MASS SPECTROMETRY
10
作者 Feng Qiu Tianyi Qiu +2 位作者 Yang Yu Liqin Ding Xinchi Feng 《World Journal of Traditional Chinese Medicine》 2015年第4期100-101,共2页
Curcumin,a safe natural yellow pigment with a wide range of pharmacological activities,is used both in herbal drugs and as a food coloring agents.Studies have shown that curcumin would suffer from extensive metabolism... Curcumin,a safe natural yellow pigment with a wide range of pharmacological activities,is used both in herbal drugs and as a food coloring agents.Studies have shown that curcumin would suffer from extensive metabolism in vivoand the predominant metabolic pathways are reduction and conjugation.In order to comprehensively study the metabolism and enrich the metabolic profile of cxurcumin in vivo,we carried out this research.A systematic method with highly sensitive UPLC-Q/TOF-MS was established to analyze different biological samples of rats after 展开更多
关键词 GLOBAL ANALYSIS OF THE METABOLITES OF CURCUMIN IN RATS BY ultra performance liquid chromatography COUPLED WITH quadrupole TIME OF-FLIGHT tandem mass spectrometry
原文传递
Detecting N-nitrosamines in water treatment plants and distribution systems in China using ultra-performance liquid chromatography-tandem mass spectrometry 被引量:11
11
作者 Chengkun WANG Xiaojian ZHANG +1 位作者 Jun WANG Chao CHEN 《Frontiers of Environmental Science & Engineering》 SCIE EI CAS CSCD 2012年第6期770-777,共8页
N-nitrosodimethylamine (NDMA) and several other N-nitrosamines have been detected as disinfection by-products in drinking waters in many countries around the world. An ultra-performance liquid chromatography- tandem... N-nitrosodimethylamine (NDMA) and several other N-nitrosamines have been detected as disinfection by-products in drinking waters in many countries around the world. An ultra-performance liquid chromatography- tandem mass spectrometry method with solid phase extraction sample preparation was developed to study the occurrence of N-nitrosamines in several water treatment plants and distribution systems in China. Isotope labeled N-nitrosodi-n-propylamine-dl4 (NDPA-dl4) was selected as the internal standard for quantification. The solid phase extraction procedures including pH, enrichment process and MS/MS parameters including capillary voltage, cone gas flow, cone voltage, collision energy were optimized to give average recoveries of 26% to 112% for nine N- nitrosamine species. The instrument detection limits were estimated to range from 0.5 to 5μg.L-1 for the nine N- nitrosamine species. NDMA and several other N-nitrosa- mines were found at fairly high concentrations in several water treatment plants and distribution systems. NDMA was found in all locations, and the highest concentrations in cities B, G, T, and W were 3.0, 35.7, 21.3, and 19.7 ng. L 1, respectively. A wide range of N-nitrosamines concentrations and species were observed in different locations. Higher concentrations of N-nitrosamines were detected in distribution systems that were further away from the treatment plants, suggesting that the contact time between the residual disinfectant and natural organic matter may play an important role in the formation of these compounds. 展开更多
关键词 N-NITROSAMINES water treatment plant distri-bution system ultra-performance liquid chromatography-tandem mass spectrometry
原文传递
Development of a Rapid and Simultaneous Detection Method for Buprenorphine, Norbuprenorphine and Naloxone in Human Plasma Using Ultra-high Performance Liquid Chromatography- tandem Mass Spectrometer with Solid-phase Extraction 被引量:1
12
作者 Guo, Qiaozhen Du, Zhenxia 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2011年第9期1922-1926,共5页
A simultaneous method was successfully established and validated for the separation and determination of bu- prenorphine (BP), its primary metabolite, nor-buprenorphine (NBP) and a proposed co-formulate, naloxone ... A simultaneous method was successfully established and validated for the separation and determination of bu- prenorphine (BP), its primary metabolite, nor-buprenorphine (NBP) and a proposed co-formulate, naloxone (NLX) in human plasma. The method used buprenorphine-d4 (BP-D4), nor-buprenorphine-d3 (NBP-D3), naltrexone (NTX) as internal standards (ISs). 100 μL of plasma sample fortified with the ISs was cleaned up by solid-phase extraction (SPE), and was then separated on a Waters AcquityTM BEH C18 column with gradient elution using methanol and water (containing 0.2% formic) at a flow rate of 0.25 mL·min^-1. The mass spectrometer was used for detection and was operated in the positive electrospray ionization with multiple reaction monitoring (MRM) mode. The three compounds were effectively separated in 5 min. The linear ranges of the compounds were 0.1--25, 0.25--25 and 0.05--25 ng·mL^-1 for BP, NBP and NLX, respectively, with r≥0.9935. The method had high sensitivity (the lim- its of detection were 0.02, 0.1 and 0.01 ng.mL-1 for BP, NBP and NLX, respectively) and high recoveries (≥97.6%). The result was shown to be linear and satisfactorily met current acceptance criteria for validation of bio- analytical method: intra and inter assay precisions within the required limits of ≤25% RSD. The LOQs fulfilled the LOQ requirements: precision≤25% RSD, and was fully validated according to the State Food and Drug Administration (SFDA) regulations. The results demonstrated that ultra-high performance liquid chromatography- tandem mass spectrometer (UPLC-MS/MS) with SPE was a powerful detection tool and contributed to pharmaceutical analysis in biological matrices. 展开更多
关键词 ultra-high performance liquid chromatography-tandem mass spectrometer BUPRENORPHINE naloxone norbuprenorphine human plasma
原文传递
Simultaneous Determination of Six Compounds in Rat Plasma by Ultra-Performance Liquid Chromatography with Tandem Mass Spectrometry: Application in the Pharmacokinetic Study of Qing Gan-Shu Yu-Fang 被引量:1
13
作者 Hai Jiang A-Jiao Houa +10 位作者 Yan-Yan Zhang Wen-Jing Man Liu Yang Yong-Hai Meng Xin-Yue Guo Song Wang Jia-Xu Zhang Bing-You Yang Qiu-Hong Wang Kelvin Chan Hai-Xue Kuang 《World Journal of Traditional Chinese Medicine》 2019年第4期250-259,共10页
A rapid and high selective ultra-performance liquid chromatography(UPLC)with tandem mass spectrometry method for simultaneous determination of six compounds including albiflorin,paeoniflorin,picroside I,picroside II,s... A rapid and high selective ultra-performance liquid chromatography(UPLC)with tandem mass spectrometry method for simultaneous determination of six compounds including albiflorin,paeoniflorin,picroside I,picroside II,saikosaponin A,and saikosaponin D in rat plasma was developed and validated using butyl p-hydroxybenzoate as an internal standard.One-step direct protein precipitation with acetonitrile was used to extract the compounds from the rat plasma samples.Chromatographic separation was achieved using an ACQUITY UPLC BEH C18 column(100 mm×2.1 mm,1.7μm)at a flow rate of 0.4 m L/min,using gradient mode containing 0.1%formic acid in water and acetonitrile were used as the Mobile phase A and B.Electrospray ionization in negative ion mode and multiple reaction monitoring were used to identify and quantify active components.Calibration curves showed good linearity(R^2>0.9908)over a wide concentration range for all compounds.The intra-and interday precision(relative standard deviation)ranged 2.4%–7.0%and 2.6%–8.0%,respectively.The accuracy(relative error)was from-13.0%to 13.2%at all quality control levels.The recovery ranged from 81.1%to 92.5%.The validated method was successfully applied to pharmacokinetic study in rats after oral administration of Qing Gan-Shu Yu-Fang.The results show that one can draw a conclusion that these six active ingredients can be quickly absorbed and play a pharmacodynamic role rapidly in vivo. 展开更多
关键词 PHARMACOKINETICS traditional Chinese medicine prescriptions ultra-performance liquid chromatography with tandem mass spectrometry
原文传递
Rapid Determination of Tetrodotoxin in Human Plasma by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
14
作者 CHEN Weizhu ZHANG Yiping +3 位作者 SUN Jipeng XIE Quanling HONG Zhuan YI Ruizao 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2018年第6期905-911,共7页
A sensitive analytical method was developed to determine tetrodotoxin(TTX) in human plasma samples using protein precipitation, followed by ultra performance liquid chromatography(UPLC) analysis coupled with tande... A sensitive analytical method was developed to determine tetrodotoxin(TTX) in human plasma samples using protein precipitation, followed by ultra performance liquid chromatography(UPLC) analysis coupled with tandem mass spectrometry(MS/MS) using 11-deoxytetrodotoxin(11-deoxyTTX) as an internal standard. The plasma samples were prepared using protein precipitation prior to being analyzed by UPLC-MSfMS to identify TTX over a zwitterionic-hydrophilic interaction liquid chromatography column. The retention time values of TTX and 11-deoxyTTX were 4.12 and 3.67 min, respectively. TTX and 11-deoxyTTX were monitored and quantitated on the basis of their ion transitions for their respective precursor ions to their product ions(i.e., m/z 320.0→162. l for TTX and m/z 304.0→176.0 for 11-deoxyTTX) in the multiple reaction-monitoring mode. The lower limit of quantification of this method was determined to be 0.0199 ug/mL. This method showed good linearity for plasma samples that contained TTX concentrations in the range of 0.0199--1.99 ng/mL. The specificity, precision, accuracy, matrix effect, and stability characteristics of this method were also examined. The intra-assay precision and accuracy ranged from 1.89% to 6.00% and from 92.21% to 100.00%, whereas the inter-assay precision and accuracy ranged from 0.64% to 7.75% and from 99.38% to 101.26%, respectively. This new method therefore represents a rapid, accurate, reliable, and highly sensitive method for the qualitative and quantitative analyses of a trace amount of TTX in human plasma samples. 展开更多
关键词 Tetrodotoxin(TTX) 11-DeoxyTTX ultra performance liquid chromatography(UPLC)coupled with tandem mass spectrometry(MS/MS) PLASMA Protein precipitation
原文传递
An Automatic Solid Phase Extraction and Ultra-Performance Liquid Chromatography Tandem Mass Spectrometry for Determination of Seven Microcystins at Ultra-Trace Levels in Surface Water
15
作者 SHEN Fei XU Yanjuan +1 位作者 WANG Ye CHEN Jing 《Wuhan University Journal of Natural Sciences》 CAS CSCD 2019年第1期30-36,共7页
A method was developed for the detection of seven microcystins(microcystin-LR, RR, YR, LA, LY, LW and LF) in surface water using automatic solid-phase extraction(A-SPE) coupled with ultra-performance liquid chromatogr... A method was developed for the detection of seven microcystins(microcystin-LR, RR, YR, LA, LY, LW and LF) in surface water using automatic solid-phase extraction(A-SPE) coupled with ultra-performance liquid chromatography tandem mass spectrometry(UPLC-MS/MS). The automated solid-phase extraction system was used to extract microcystins(MCs) from water samples. UPLC-MS/MS was used to determine MCs concentrations in just 5 min. Method detection limits were from 0.3 to 0.9 ng/L, microcystin recoveries ranged from 83.8% to 114%, and the relative standard deviation(RSD) varied from 5.6% to 12.5%. This analytical approach was found to be simple, highly sensitive, accurate, which required little manual operation. Additionally, to validate this analytical method, A-SPE+UPLC-MS/MS was applied to characterize the concentration of MCs in Taihu Lake, Wuxi, China. 展开更多
关键词 MICROCYSTINS AUTOMATIC SOLID-PHASE extraction ultra-performance liquid chromatography tandem mass spectrometry(UPLC-MS/MS)
原文传递
Investigations on the degradation of aspartame using high-performance liquid chromatography/tandem mass spectrometry
16
作者 Jie-Ping Sun Qiang Han +1 位作者 Xiao-Qiong Zhang Ming-Yu Ding 《Chinese Chemical Letters》 SCIE CAS CSCD 2014年第9期1259-1264,共6页
Aspartame is a widely used sweetener, the long-term safety of which has been controversial ever since it was accepted for human consumption. It is unstable and can produce some harmful degradation products under certa... Aspartame is a widely used sweetener, the long-term safety of which has been controversial ever since it was accepted for human consumption. It is unstable and can produce some harmful degradation products under certain storage conditions. A high-performance liquid chromatography/tandem mass spectrometry method was developed for the simultaneous analysis of aspartame and its four degradation products, including aspartic acid, phenylalanine, aspartyl-phenylalanine and 5-benzyl-3,6- dioxo-2-piperazieacetic acid in water and in diet soft drinks. Aspartame and its four degradation products were quantified by a matrix matched external standard calibration curve with excellent correlation coefficients. The limits of detection were 0.16-5.8 μg/L, which exhibited higher sensitivity than common methods. This method was rapid, sensitive, specific and capable of eliminating matrix interferences. It was also applied to the study of the degradation of aspartame at various pH and temperatures. The results indicated that aspartame was partly degraded under strong acidic or basic conditions and the extent of degradation increased with increasing temperature. 展开更多
关键词 high-performance liquid chromatography/tandem mass spectrometry ASPARTAME Degradation productsCola
原文传递
超高效液相色谱-串联质谱法同时测定蔬菜中氯酸盐和高氯酸盐 被引量:2
17
作者 邹淼 刘顺鑫 +1 位作者 冯静 韩晓鸥 《化学分析计量》 CAS 2024年第2期62-66,共5页
建立超高效液相色谱-串联质谱法测定蔬菜中氯酸盐和高氯酸盐。样品以少量水稀释分散后,加入乙腈提取,经PRIME HLB小柱净化,用Waters Torus DEA色谱柱(100 mm×2.1 mm,1.7μm)分离,以同位素内标法定量。在各自的线性范围内,氯酸盐、... 建立超高效液相色谱-串联质谱法测定蔬菜中氯酸盐和高氯酸盐。样品以少量水稀释分散后,加入乙腈提取,经PRIME HLB小柱净化,用Waters Torus DEA色谱柱(100 mm×2.1 mm,1.7μm)分离,以同位素内标法定量。在各自的线性范围内,氯酸盐、高氯酸盐的质量浓度与氯酸盐、高氯酸盐和相应同位素内标物的色谱峰面积比线性关系良好,相关系数均大于0.999。氯酸盐的检出限为3.0μg/kg,定量限为10μg/kg,高氯酸盐的检出限为1.5μg/kg,定量限为4.5μg/kg,平均回收率为88.9%~97.1%,相对标准偏差为2.9%~7.4%(n=6)。该方法简便、快速,适用于蔬菜中氯酸盐和高氯酸盐的同时快速检测。 展开更多
关键词 超高效液相色谱-串联质谱 氯酸盐 高氯酸盐 蔬菜
下载PDF
阿莫西林胶囊在中国健康人体内的生物等效性研究 被引量:1
18
作者 卢俊丽 刘婉莹 +7 位作者 李灿霞 黄丽凤 张婵娟 李艳波 雷雨燕 陈露露 欧阳冬生 颜羽 《广西医科大学学报》 CAS 2024年第1期98-103,共6页
目的:研究阿莫西林胶囊在中国健康人体内的生物等效性。方法:以单中心、开放式、随机、双制剂、两周期、两序列交叉试验设计,共48例受试者(空腹试验和餐后试验各24例),口服0.25 g阿莫西林胶囊受试制剂或参比制剂。高效液相色谱—串联质... 目的:研究阿莫西林胶囊在中国健康人体内的生物等效性。方法:以单中心、开放式、随机、双制剂、两周期、两序列交叉试验设计,共48例受试者(空腹试验和餐后试验各24例),口服0.25 g阿莫西林胶囊受试制剂或参比制剂。高效液相色谱—串联质谱(LC-MS/MS)分析方法测定给药后不同时间阿莫西林的血药浓度,并计算主要药代动力学参数,判定两制剂是否等效。结果:空腹试验显示,受试制剂和参比制剂阿莫西林的药物峰浓度(C_(max))分别为(5483.296±1321.102)ng/mL、(5611.291±1659.407)ng/mL,从时间0到t之间血药浓度—时间曲线下面积(AUC_(0-t))分别为(13255.3±1715.7)h·ng/mL、(13115.5±2091.7)h·ng/mL,从0时到无限时间(∞)的血药浓度—时间曲线下面积(AUC_(0-∞))分别为(13329.4±1718.8)h·ng/mL、(13192.7±2107.1)h·ng/mL,达峰时间(T_(max))均为1.38 h。餐后试验显示,受试制剂和参比制剂阿莫西林的C_(max)分别为(4218.072±780.598)ng/mL、(4156.713±877.752)ng/mL,AUC_(0-t)分别为(13073.9±1584.3)h·ng/mL、(12817.8±1575.5)h·ng/mL,AUC_(0-∞)分别为(13166.8±1606.0)h·ng/mL、(12914.8±1587.2)h·ng/mL,T_(max)均为3.00 h。两种试验制剂C_(max)、AUC_(0-t)、AUC_(0-∞)几何均值比值的90%置信区间(CI)均在可接受的生物等效性范围内(80%~125%)。结论:两种阿莫西林胶囊在中国健康志愿者体内吸收速度和吸收程度生物等效。 展开更多
关键词 阿莫西林 生物等效性 药代动力学 高效液相色谱—串联质谱
下载PDF
固相萃取结合高效液相色谱-串联质谱测定胎便中14种全氟和多氟烷基化合物 被引量:1
19
作者 刘超 何安恩 +2 位作者 罗雅丹 黎娟 王亚韡 《环境化学》 CAS CSCD 北大核心 2024年第5期1553-1564,共12页
全氟和多氟烷基化合物(PFASs)是一类人工合成的物质,由于其热稳定、疏水、疏油等优良性质而被广泛使用于生活和生产中.PFASs具有环境持久性、生物累积性、多种毒性等特性,且可以通过胎盘屏障进入到胎儿体内,进而对胎儿健康产生潜在危害... 全氟和多氟烷基化合物(PFASs)是一类人工合成的物质,由于其热稳定、疏水、疏油等优良性质而被广泛使用于生活和生产中.PFASs具有环境持久性、生物累积性、多种毒性等特性,且可以通过胎盘屏障进入到胎儿体内,进而对胎儿健康产生潜在危害.胎便中积累了妊娠期间暴露于胎儿的外源性化合物,可用于监测PFASs对胎儿的宫内暴露特征.本研究基于固相萃取结合高效液相色谱-串联质谱技术,建立了胎便中14种PFASs的分析方法.采用乙腈/水(9∶1,V/V)对0.2 g冻干胎便样品进行超声提取,提取液经Envi-carb和Oasis WAX小柱固相萃取,0.1%氨甲醇洗脱.以10 mmol·L^(−1)乙酸铵水溶液和乙腈作为流动相对目标化合物进行梯度洗脱,采用Acquity UPLC BEH C18色谱柱进行分离,基于多反应监测负离子模式采集,内标法定量.结果表明,在2、5、20 ng·g^(−1)的加标浓度下,14种PFASs的回收率为65%—149%,相对标准偏差为3%—22%,方法检出限(MDLs)为0.001—0.149 ng·g^(−1),方法定量限(MQLs)为0.003—0.495 ng·g^(−1).使用该方法测定了10个胎便样品,ΣPFASs浓度范围为<MDLs—2.49 ng·g^(−1).该方法操作简单、便捷、灵敏度高且定量准确,为系统性研究胎便中PFASs的赋存特征及暴露风险提供了技术基础. 展开更多
关键词 胎便 全氟和多氟烷基化合物 高效液相色谱-串联质谱 固相萃取
下载PDF
环孢素A和他克莫司的高效液相色谱-串联质谱检测及其室内质控评价 被引量:1
20
作者 钟里科 米秀芳 +3 位作者 舒琦 许高奇 何超能 朱俊峰 《医药导报》 北大核心 2024年第2期196-202,共7页
目的建立环孢素A和他克莫司治疗药物监测的高效液相色谱-串联质谱(HPLC-MS/MS)质控方法,应用Westgard多规则理论对质控样品进行评估。方法利用HPLC-MS/MS建立人全血中环孢素A和他克莫司的血药浓度检测方法。对治疗药物监测过程中低、中... 目的建立环孢素A和他克莫司治疗药物监测的高效液相色谱-串联质谱(HPLC-MS/MS)质控方法,应用Westgard多规则理论对质控样品进行评估。方法利用HPLC-MS/MS建立人全血中环孢素A和他克莫司的血药浓度检测方法。对治疗药物监测过程中低、中、高3个浓度水平的质控样品进行统计分析,绘制Levery-Jennings和Z分数质控图,应用Westgard多规则理论进行室内质控评估。结果环孢素A和他克莫司的线性范围分别为10.40~1040.00和0.50~49.50 ng·mL^(-1),定量下限分别为10.40和0.50 ng·mL^(-1),提取回收率分别为108.61%~113.24%和101.99%~109.37%,内标归一化的基质因子分别为106.68%~111.27%和95.70%~97.81%,日内和日间的准确度及精密度均小于15.0%,其他参数也均符合生物样本定量分析要求。Levery-Jennings和Z分数质控图显示,2022年第三季度26组质控样品的检测结果提出警告4次(违反12s规则),未出现失控现象。结论建立的环孢素A和他克莫司治疗药物监测室内质控体系能够有效保障血药浓度检测的准确性。 展开更多
关键词 环孢素A 他克莫司 高效液相色谱-串联质谱 治疗药物监测 Westgard多规则理论 质控图
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部