期刊文献+
共找到4,536篇文章
< 1 2 227 >
每页显示 20 50 100
Simultaneous Determination of 14 β-Receptor Agonists Residues in Mutton by High Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS)
1
作者 Zhe MENG Jianhua WANG +5 位作者 Bo LIU Yuhang GUO Haoshuang DONG Pingyang SHAN Dawei WANG Yajuan SONG 《Agricultural Biotechnology》 CAS 2023年第5期55-58,共4页
[Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-g... [Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-glucuronidase and extracted with 5%acetic acid-acetonitrile(1:99,V/V)solution.An Eclipse plus C 18 column was used for separation,and the MRM mode was used for qualitative analysis,and the external standard method was used for quantitative analysis of matrix standard solutions.[Results]Under the optimal conditions,the retention time of the 14 kinds ofβ-receptor agonists ranged from 1.0 to 9.5 min.When the mass concentration was in the range of 0.05-0.50μg/ml,the linear relationship ofβ-receptor agonists was good,with correlation coefficients(r)≥0.9992.The detection limits of the method were in the range of 0.04-0.87μg/kg,and the quantitative limits were in the range of 0.35-1.86μg/kg.The average recovery values were in the range of 82.8%-108.9%,with RSDs(n=6)in the range of 1.9%-6.7%.[Conclusions]The method is simple,sensitive,reproducible,accurate,and can be used for simultaneous determination of the 14 kinds ofβ-receptor agonist residues in mutton. 展开更多
关键词 MUTTON High performance liquid chromatography-tandem mass spectrometry β-receptor agonist RESIDUE
下载PDF
Determination of Oleuropein in Cosmetics by Ultra Performance Liquid Chromatography-Triple Quadrupole Tandem Mass Spectrometry
2
作者 Pan Lijing Chen Weiwei Yuan Minjia 《China Detergent & Cosmetics》 CAS 2023年第4期30-36,共7页
An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracte... An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics. 展开更多
关键词 ultra performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS) OLEUROPEIN COSMETICS
下载PDF
Simultaneous Determination of Bisphenols and Alkylphenols in Water by Solid Phase Extraction and Ultra Performance Liquid Chromatography-tandem Mass Spectrometry 被引量:4
3
作者 SHAN Xiao Mei SHEN Deng Hui +2 位作者 WANG Bing Shuang LU Bei Bei HUANG Fa Yuan 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第6期471-474,共4页
To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry ... To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%. 展开更多
关键词 UPLC BPA Simultaneous Determination of Bisphenols and Alkylphenols in Water by Solid Phase Extraction and ultra performance liquid chromatography-tandem mass Spectrometry mass
下载PDF
Determination of Steroid Hormone Residues in Fish Tissues Using Gel Permeation Chromatography and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry 被引量:3
4
作者 LI Peipei YAN Zhongyong +3 位作者 SUN Xiumei CHEN Si CHEN Yin ZHANG Xiaojun 《Journal of Ocean University of China》 SCIE CAS CSCD 2018年第5期1171-1177,共7页
A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 s... A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues. 展开更多
关键词 ultra performance liquid chromatography-tandem mass spectrometry anabolic hormone gel permeation chromatography fish tissue
下载PDF
Uncertainty Evaluation of Determination of Microcystin MC-LR in Environmental Samples by Solid Phase Extraction-Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry 被引量:1
5
作者 Zhao Bin Zhang Min Zhang Fuhai 《Meteorological and Environmental Research》 CAS 2016年第6期54-57,共4页
To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated first... To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2). 展开更多
关键词 Uncertainty SOLID phase extraction ultra performance liquid CHROMATOGRAPHY TANDEM mass SPECTROMETRY MICROCYSTIN MC-LR China
下载PDF
Determination of thyreostats in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry
6
作者 Lech RODZIEWICZ Jolanta MASLOWIECKA +1 位作者 Anna SADOWSKA Halina CAR 《色谱》 CAS CSCD 北大核心 2017年第10期1048-1054,共7页
Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC... Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine. 展开更多
关键词 ultra-high performance liquid chromatography-tandem mass SPECTROMETRY (UHPLC-MS/MS) thyreostats (TSs) URINE
下载PDF
Rapid Determination of Three Kinds of Microcystins in Environmental Water Samples by Disk SPE-Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
7
作者 Zhao Bin Zhang Min Zhang Fuhai 《Meteorological and Environmental Research》 CAS 2016年第5期62-64,68,共4页
A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established.... A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples. 展开更多
关键词 Disk SOLID-PHASE extraction COLUMN ultra performance liquid chromatography-tandem mass SPECTROMETRY Environmental water sample MICROCYSTINS Lake Chao China
下载PDF
Determination of Sodium Pentachlorophenoxide Residues in Animal-derived Foods by Ultra-performance Liquid Chromatography-Tandem Mass Spectrometry (UPLC-MS/MS)
8
作者 Chengmei WANG Chunxia CHENG +2 位作者 Guixia YANG Susu ZHANG Xuan QIAN 《Agricultural Biotechnology》 CAS 2022年第2期99-101,105,共4页
[Objectives]This study was conducted to establish an ultra-high performance liquid chromatography-tandem mass spectrometry for the rapid extraction of sodium pentachlorophenoxide from animal-derived food.[Methods]The ... [Objectives]This study was conducted to establish an ultra-high performance liquid chromatography-tandem mass spectrometry for the rapid extraction of sodium pentachlorophenoxide from animal-derived food.[Methods]The samples were extracted with an acetonitrile water solution(8∶2),0.1 mol/L hydrochloric acid and a purification extraction bag with shaking.Centrifugation was performed to obtain supernatants,which were added to purification tubes containing PSA and C_(18) for purification,and then filtered with membranes for determination.Each test solution was separated by a ZORBAX Eclipse plus C_(18) column with acetonitrile and 5 mmol/L ammonium acetate as mobile phases,and determined with electrospray ionization and multiple reaction monitoring.[Results]The method had good linearity in the concentration range of 1.0-50 ng/ml,and the correlation coefficient was 0.9997.The limit of detection was 0.25μg/kg and the limit of quantification was 0.75μg/kg.The recovery was between 87.4%and 112.5%,and the RSD%was between 0.5%and 10.0%.[Conclusions]The method has simple operation and high sensitivity,and is suitable for trace detection of sodium pentachlorophenoxide in large quantities of animal-derived food. 展开更多
关键词 Sodium pentachlorophenoxide ultra-high performance liquid chromatography-tandem mass spectrometry Animal-derived food Trace analysis
下载PDF
An Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry Method for the Quantification of Vancomycin Requiring Only 2 μL of Rabbit Serum
9
作者 Veronika Schmitt Andras Szeitz +1 位作者 Tara L.Klassen Urs O.Hafeli 《American Journal of Analytical Chemistry》 2017年第9期553-563,共11页
A highly sensitive ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed for the quantification of vancomycin (VAN) in low volumes of rabbit serum. For each analysis,... A highly sensitive ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed for the quantification of vancomycin (VAN) in low volumes of rabbit serum. For each analysis, 2 μL rabbit serum was precipitated with methanol that contained the internal standard teicoplanin (TEI). The supernatant was transferred into a 384 well-plate, diluted with water, covered with a pierceable silicone mat and 5 μL was analyzed in positive ionization mode. The UHPLC-MS/MS consisted of an Agilent 1290 Infinity UHPLC system connected to an AB Sciex QTrap&reg;5500 hybrid linear ion-trap triple quadrupole mass spectrometer equipped with a Turbo Spray source. Chromatographic separation was achieved using a Waters Acquity UPLC BEH C18 (1.7 μm, 2.1 mm × 100 mm) column, a VanGuard (1.7 μm, 2.1 × 5 mm) guard column and a mobile phase of water and methanol both containing 5 mM ammonium acetate with 0.1% formic acid. VAN was quantified with multiple reaction monitoring using the transitions of m/z 725.5/144.2, and TEI was monitored at m/z 940.6/316.4. The accuracy, precision, linearity, range and lower limit of quantification (LLOQ) were determined. The accuracy was ≤9.93% and the precision was ≤10.6%. The range was established as 0.1 to 40 μg·mL-1. The LLOQ was 0.1 μg·mL-1 VAN requiring 2 μL of sample with an accuracy of -20.2% and precision of 8.39%. The method was applied successfully to determine the VAN concentrations in rabbit serum after the i.v. administration of VAN via implanted ear catheters. 展开更多
关键词 ultra-High performance liquid chromatography-tandem mass Spectrometry VANCOMYCIN RABBIT SERUM PHARMACOKINETICS
下载PDF
Detection of 36 antibiotics in coastal waters using high performance liquid chromatography-tandem mass spectrometry 被引量:13
10
作者 那广水 顾佳 +4 位作者 葛林科 张蓬 王震 刘春阳 张琳 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2011年第5期1093-1102,共10页
Among pharmaceuticals and personal care products released into the aquatic environment, antibiotics are of particular concern, because of their ubiquity and health effects. Although scientists have recently paid more ... Among pharmaceuticals and personal care products released into the aquatic environment, antibiotics are of particular concern, because of their ubiquity and health effects. Although scientists have recently paid more attention to the threat of antibiotics to coastal ecosystems, researchers have often focused on relatively few antibiotics, because of the absence of suitable analytical methods. We have therefore developed a method for the rapid detection of 36 antibiotic residues in coastal waters, including tetracyclines (TCs), sulfanilamides (SAs), and quinolones (QLs). The method consists of solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis, using electrospray ionization (ESI) in positive mode. The SPE was performed with Oasis HLB and Oasis MCX cartridges. Chromatographic separation on a Cr8 column was achieved using a binary eluent containing methanol and water with 0.1% formic acid. Typical recoveries of the analytes ranged from 67.4% to 109.3% at a fortification level of 100 ng/L. The precision of the method, calculated as relative standard deviation (RSD), was below 14.6% for all the compounds. The limits of detection (LODs) varied from 0.45 pg to 7.97 pg. The method was applied to detemaine the target analytes in coastal waters of the Yellow Sea in Liaoning, China. Among the tested antibiotics, 31 were found in coastal 'waters, with their concentrations between the LOD and 212.5 ng/L. These data indicate that this method is valid for analysis of antibiotics in coastal waters. The study first reports such a large number of antibiotics along the Yellow Sea coast of Liaoning, and should facilitate future comprehensive evaluation of antibiotics in coastal ecosystems 展开更多
关键词 ANTIBIOTICS high performance liquid chromatography-tandem mass spectrometry SOLID-PHASEEXTRACTION coastal waters
下载PDF
Chemical Components of Achyranthes bidentata Leaves by Ultra High Performance Liquid Chromatography-Mass Spectrometry 被引量:1
11
作者 Haiyang DONG Jinshuo MA Fulin YAN 《Medicinal Plant》 CAS 2019年第4期16-19,共4页
[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical c... [Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical components of A. bidentata leaves were rapidly analyzed using the ultra high performance liquid chromatography-time of flight-high resolution mass spectrometry (UHPLC-TOF-MS).[Results] Thirty eight chemical compounds were identified in samples of A. bidentata leaves collected from Wen County of Henan Province, in which seven chemical compounds had the relative content higher than 5%, linoleic acid reached 25.7% and inokosterone A reached 13.8%.[Conclusions] A. bidentata leaves contain many kinds of chemical compounds. This study is expected to provide a certain basis for further extraction of linoleic acid and inokosterone A. 展开更多
关键词 Achyranthes bidentata LEAVES ultra high performance liquid chromatography-mass SPECTROMETRY (UHPLC-MS) Chemical components Inokosterone
下载PDF
Simultaneous Determination of Ultraviolet Absorbers and Antibacterial Agents in Textiles by Ultra-High Performance Liquid Chromatography/Orbitrap High Resolution Mass Spectrometry 被引量:1
12
作者 Chengyun Wang Tangtang Xie +2 位作者 Rong Xu Junfeng Lin Lixia Li 《World Journal of Engineering and Technology》 2017年第1期1-18,共18页
This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile sampl... This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles. 展开更多
关键词 ultra-High performance liquid Chromatography/Orbitrap High Resolution mass Spectrometry Benzotriazoleultraviolet ABSORBERS Isothiazolinone Tric-losan 4-Chloro-3 5-Dimethyl Phenol
下载PDF
Lysophosphatidylcholine Biomarkers of Lung Cancer Detected by Ultra-performance Liquid Chromatography Coupled with Quadrupole Time-of-flight Mass Spectrometry
13
作者 DONG Jun CAI Xiao-ming +4 位作者 ZOU Li-juan CHEN Cheng XUE Xing-ya ZHANG Xiu-li LIANG Xin-miao 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第5期750-755,共6页
Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients a... Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients and 34 healthy volunteers were prepared with this approach. With ultra-performance liquid chromatography(UPLC) coupled with quadrupole time-of-flight mass spectrometry(Q-TOF MS) analysis, the samples were investigated in order to find potential disease biomarkers. After data acquisition, orthogonal signal correction partial least squares models were built to differentiate the healthy volunteers from lung cancer patients and to identify metabolites that showed significantly different expression between the two groups. Several metabolite ions were identified as potential biomarkers according to the variable importance in the project(VIP) value in both ion modes. Five lysophosphatidylcholines were further identified as specifically lysoPC 16:0, isomer of lysoPC 16:0, lysoPC 18:0, lysoPC 18:1 and lysoPC 18:2. These results suggest that UPLC coupled with Q-TOF MS is an effective technique for the analysis of plasma metabolites in metabonomic studies. 展开更多
关键词 METABONOMICS Sample preparation ultra-performance liquid chromatography coupled with quadrupoletime-of-flight mass spectrometry(UPLC/Q-TOF MS) Lung cancer Biomarker
下载PDF
Establishing a protein expression profile database for the normal human pituitary gland using two-dimensional high-performance liquid chromatography combined with LTQ-Orbitrap mass spectrometry 被引量:2
14
作者 Rong Xie Wei Xu +4 位作者 Weimin Bao Hang Liu Luping Chen Yiwen Shen Jianhong Zhu 《Neural Regeneration Research》 SCIE CAS CSCD 2012年第36期2922-2928,共7页
In this study, we selected adult normal pituitary gland tissues from six patients during operations for pituitary microadenomas via the transsphenoidal approach for extended normal pituitary tissue resection around th... In this study, we selected adult normal pituitary gland tissues from six patients during operations for pituitary microadenomas via the transsphenoidal approach for extended normal pituitary tissue resection around the tumor, and analyzed the protein expression of human normal pituitary using two-dimensional high-performance liquid chromatography combined with LTQ-Orbitrap mass spectrometry proteomics technology. The ten most highly expressed proteins in normal human pituitary were: alpha 3 type VI collagen isoform 5 precursor (abundance among tall pituitary proteins 1.30%), fibrinogen beta chain preproprotein (0.99%), vimentin (0.73%), prolactin (0.69%), ATP synthase, H~ transporting and mitochondrial F1 complex beta subunit precursor (0.52%), keratin I (0.49%), growth hormone (0.45%), carbonic anhydrase I (0.40%), heat shock protein 90 kDa I (0.31%), and annexin V (0.30%). Based on the biological function classifications of these proteins, the top three categories by content were neuroendocrine proteins (abundance among all pituitary proteins, 40.1%), catalytic and metabolic proteins (28.3%), and cell signal transduction proteins (9.8%). Based on cell positioning classification, the top three categories were cell organelle (24.5%) membrane (20.8%), and cytoplasm (13.0%). Based on biological process classification, the top three categories of proteins are involved in physiological processes (42.9%), cellular processes (40.4%), and regulation of biological processes (9.1%). Our experimental findings indicate that a protein expression profile database of normal human pituitary can be precisely and efficiently established by proteomics technology. 展开更多
关键词 two-dimensional high-performance liquid chromatography mass spectrum pituitary gland PROTEINS PROTEOMICS hypophyseal tumor physiological function pathological mechanism
下载PDF
Determination of okadaic acid related toxins from shellfish (<i>sinonovacula constricta</i>) by high performance liquid chromatography tandem mass spectrometry
15
作者 Hai-qi Zhang Weicheng Liu +3 位作者 Xin He Li-jun Liang Wenyong Ding Zhong-yang He 《Agricultural Sciences》 2013年第5期1-6,共6页
Consumption of shellfish contaminated with algal toxins produced by marine dinoflagellates can lead to diarrhetic shellfish poisoning (DSP). It was therefore essential that there are analytical techniques to identify ... Consumption of shellfish contaminated with algal toxins produced by marine dinoflagellates can lead to diarrhetic shellfish poisoning (DSP). It was therefore essential that there are analytical techniques to identify and quantify DSP toxins in shellfish. This new methodology could facilitate DSP monitoring and create a means of rapidly responding to incidents threatening public health. In the last years there were different analytical methods for DSP, such as mouse bioassay and LC-FLD. With the development of instrument, Liquid chromatography-mass spectrometry was substituted for other analytical methods with its good sensitivity and selectivity and without derivatization for the determination of DSP. In this report, a high performance liquid chromatogra-phytandem mass spectrometric(HPLC-MS/MS)method was developed for the simultaneous determination of okadaic acid (OA) and dinophysistoxins(DTX1) in Sinonovacula constricta. Optimization of pretreatment experiment was carried out to maximize recoveries and the effectiveness. The analytes were determined under multi-reactions monitoring (MRM) scan type with tandem mass analyzer using negative ion electrospray ionization (-ESI) mode .Finally, the detection and identification of OA and DTX-1 were based upon their retention times (RT) and the fragmentation patterns of their mass spectra. The method of LOQ for the two poisons was 0.02 mg·kg-1.The real sample test showed that this method could be used for sensitive, fast, and accurate determination of the two diarrheic shellfish poisons in shellfish. 展开更多
关键词 Sinonovacula Constricta High performance liquid chromatography-tandem mass Spectrometry Okadaic Acid Dinophysistoxins-1
下载PDF
Detecting N-nitrosamines in water treatment plants and distribution systems in China using ultra-performance liquid chromatography-tandem mass spectrometry 被引量:11
16
作者 Chengkun WANG Xiaojian ZHANG +1 位作者 Jun WANG Chao CHEN 《Frontiers of Environmental Science & Engineering》 SCIE EI CAS CSCD 2012年第6期770-777,共8页
N-nitrosodimethylamine (NDMA) and several other N-nitrosamines have been detected as disinfection by-products in drinking waters in many countries around the world. An ultra-performance liquid chromatography- tandem... N-nitrosodimethylamine (NDMA) and several other N-nitrosamines have been detected as disinfection by-products in drinking waters in many countries around the world. An ultra-performance liquid chromatography- tandem mass spectrometry method with solid phase extraction sample preparation was developed to study the occurrence of N-nitrosamines in several water treatment plants and distribution systems in China. Isotope labeled N-nitrosodi-n-propylamine-dl4 (NDPA-dl4) was selected as the internal standard for quantification. The solid phase extraction procedures including pH, enrichment process and MS/MS parameters including capillary voltage, cone gas flow, cone voltage, collision energy were optimized to give average recoveries of 26% to 112% for nine N- nitrosamine species. The instrument detection limits were estimated to range from 0.5 to 5μg.L-1 for the nine N- nitrosamine species. NDMA and several other N-nitrosa- mines were found at fairly high concentrations in several water treatment plants and distribution systems. NDMA was found in all locations, and the highest concentrations in cities B, G, T, and W were 3.0, 35.7, 21.3, and 19.7 ng. L 1, respectively. A wide range of N-nitrosamines concentrations and species were observed in different locations. Higher concentrations of N-nitrosamines were detected in distribution systems that were further away from the treatment plants, suggesting that the contact time between the residual disinfectant and natural organic matter may play an important role in the formation of these compounds. 展开更多
关键词 N-NITROSAMINES water treatment plant distri-bution system ultra-performance liquid chromatography-tandem mass spectrometry
原文传递
A Validated Liquid Chromatography-Mass Spectrometry Method for the Detection and Quantification of Oxidative Metabolites of 2,2',4,4'-Tetrabromodiphenyl Ether in Rat Hepatic Microsomes 被引量:1
17
作者 Sarah Catherine Moffatt Patrick Robert Edwards +1 位作者 András Szeitz Stelvio Mario Bandiera 《American Journal of Analytical Chemistry》 2011年第3期352-362,共11页
In the present study, we developed and validated an analytical method using ultra performance liquid chromatography-mass spectrometry (UPLC/MS) for the quantitative determination of 2,2',4,4'-tetrabromodipheny... In the present study, we developed and validated an analytical method using ultra performance liquid chromatography-mass spectrometry (UPLC/MS) for the quantitative determination of 2,2',4,4'-tetrabromodiphenyl ether (BDE-47) metabolism by rat hepatic microsomes. BDE-47 is a brominated flame retardant that was widely used in a variety of consumer products and has subsequently been identified as a ubiquitous environmental contaminant. Hydroxy-bromodiphenyl ethers (OH-BDEs) were isolated from rat hepatic microsomes by liquid-liquid extraction. Chromatographic separation was achieved by UPLC on a C18 column with gradient elution using a mobile phase consisting of methanol and water, each containing 0.1% formic acid, at a flow rate of 0.2 mL/min. Detection and quantification were performed using a mass spectrometer in single ion recording mode with negative electrospray ionization. The UPLC/MS method was validated for linearity, limit of quantification (LOQ), accuracy, precision and recovery. The weighted calibration curves (1/X2) were linear over a concentration range of 5 - 250 nM with LOQ values between 5 nM and 50 nM for the individual OH-BDEs. Intra- and inter- day accuracy (%DEV) and precision (%RSD) values ranged from –11.7% to 9.5% and 5.9% to 16.5%, respectively. Recovery values of 70% to 90% were obtained for all OH-BDEs. The validated method allowed us to successfully analyze metabolite formation following incubation of BDE-47 with hepatic microsomes prepared from phenobarbital-treated rats. Results demonstrate that the UPLC/MS method has sufficient sensitivity and reproducibility to fully characterize the in vitro metabolism of BDE-47 and possibly other PBDEs. 展开更多
关键词 BDE-47 HEPATIC Metabolism Polybrominated DIPHENYL ETHERS RAT HEPATIC MICROSOMES ultra performance liquid Chromatography-mass Spectrometry
下载PDF
Rapid Determination of Tetrodotoxin in Human Plasma by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
18
作者 CHEN Weizhu ZHANG Yiping +3 位作者 SUN Jipeng XIE Quanling HONG Zhuan YI Ruizao 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2018年第6期905-911,共7页
A sensitive analytical method was developed to determine tetrodotoxin(TTX) in human plasma samples using protein precipitation, followed by ultra performance liquid chromatography(UPLC) analysis coupled with tande... A sensitive analytical method was developed to determine tetrodotoxin(TTX) in human plasma samples using protein precipitation, followed by ultra performance liquid chromatography(UPLC) analysis coupled with tandem mass spectrometry(MS/MS) using 11-deoxytetrodotoxin(11-deoxyTTX) as an internal standard. The plasma samples were prepared using protein precipitation prior to being analyzed by UPLC-MSfMS to identify TTX over a zwitterionic-hydrophilic interaction liquid chromatography column. The retention time values of TTX and 11-deoxyTTX were 4.12 and 3.67 min, respectively. TTX and 11-deoxyTTX were monitored and quantitated on the basis of their ion transitions for their respective precursor ions to their product ions(i.e., m/z 320.0→162. l for TTX and m/z 304.0→176.0 for 11-deoxyTTX) in the multiple reaction-monitoring mode. The lower limit of quantification of this method was determined to be 0.0199 ug/mL. This method showed good linearity for plasma samples that contained TTX concentrations in the range of 0.0199--1.99 ng/mL. The specificity, precision, accuracy, matrix effect, and stability characteristics of this method were also examined. The intra-assay precision and accuracy ranged from 1.89% to 6.00% and from 92.21% to 100.00%, whereas the inter-assay precision and accuracy ranged from 0.64% to 7.75% and from 99.38% to 101.26%, respectively. This new method therefore represents a rapid, accurate, reliable, and highly sensitive method for the qualitative and quantitative analyses of a trace amount of TTX in human plasma samples. 展开更多
关键词 Tetrodotoxin(TTX) 11-DeoxyTTX ultra performance liquid chromatography(UPLC)coupled with tandem mass spectrometry(MS/MS) PLASMA Protein precipitation
原文传递
超高效液相色谱-串联质谱法同时测定蔬菜中氯酸盐和高氯酸盐 被引量:2
19
作者 邹淼 刘顺鑫 +1 位作者 冯静 韩晓鸥 《化学分析计量》 CAS 2024年第2期62-66,共5页
建立超高效液相色谱-串联质谱法测定蔬菜中氯酸盐和高氯酸盐。样品以少量水稀释分散后,加入乙腈提取,经PRIME HLB小柱净化,用Waters Torus DEA色谱柱(100 mm×2.1 mm,1.7μm)分离,以同位素内标法定量。在各自的线性范围内,氯酸盐、... 建立超高效液相色谱-串联质谱法测定蔬菜中氯酸盐和高氯酸盐。样品以少量水稀释分散后,加入乙腈提取,经PRIME HLB小柱净化,用Waters Torus DEA色谱柱(100 mm×2.1 mm,1.7μm)分离,以同位素内标法定量。在各自的线性范围内,氯酸盐、高氯酸盐的质量浓度与氯酸盐、高氯酸盐和相应同位素内标物的色谱峰面积比线性关系良好,相关系数均大于0.999。氯酸盐的检出限为3.0μg/kg,定量限为10μg/kg,高氯酸盐的检出限为1.5μg/kg,定量限为4.5μg/kg,平均回收率为88.9%~97.1%,相对标准偏差为2.9%~7.4%(n=6)。该方法简便、快速,适用于蔬菜中氯酸盐和高氯酸盐的同时快速检测。 展开更多
关键词 超高效液相色谱-串联质谱 氯酸盐 高氯酸盐 蔬菜
下载PDF
改良QuEChERS技术结合超高效液相色谱-串联质谱法测定水产品中扑草净及其代谢物残留 被引量:1
20
作者 彭婕 穆迎春 +4 位作者 喻亚丽 陈建武 刘婷 何力 甘金华 《食品科学》 EI CAS CSCD 北大核心 2024年第3期185-192,共8页
采用改良QuEChERS技术作为前处理方法,建立了水产品中扑草净及其代谢物残留的超高效液相色谱-串联质谱分析方法。样品用乙腈提取,经增强型脂质去除吸附剂与Cleanert LipoNo组合净化,采用选择反应监测正离子模式测定,内标法定量。结果表... 采用改良QuEChERS技术作为前处理方法,建立了水产品中扑草净及其代谢物残留的超高效液相色谱-串联质谱分析方法。样品用乙腈提取,经增强型脂质去除吸附剂与Cleanert LipoNo组合净化,采用选择反应监测正离子模式测定,内标法定量。结果表明:扑草净及其代谢物在1.0~500 ng/mL质量浓度范围内线性关系良好,确定系数R2大于0.992,方法检出限和定量限分别低至0.20μg/kg和0.50μg/kg,在草鱼、克氏原螯虾和中华绒螯蟹等基质的加标实验中呈现良好的准确度与精密度,平均加标回收率和相对标准偏差分别为74.4%~113.7%和3.17%~11.47%。经内标法校正,5种扑草净及其代谢物在不同水产品中的基质效应不明显。方法实现了水产品中扑草净及其代谢物的识别与定量分析,并通过检测药浴扑草净的克氏原螯虾阳性样品验证了方法的适用性。 展开更多
关键词 超高效液相色谱-串联质谱 水产品 扑草净 代谢物 QUECHERS
下载PDF
上一页 1 2 227 下一页 到第
使用帮助 返回顶部