期刊文献+
共找到4,634篇文章
< 1 2 232 >
每页显示 20 50 100
Determination of Oleuropein in Cosmetics by Ultra Performance Liquid Chromatography-Triple Quadrupole Tandem Mass Spectrometry
1
作者 Pan Lijing Chen Weiwei Yuan Minjia 《China Detergent & Cosmetics》 CAS 2023年第4期30-36,共7页
An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracte... An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics. 展开更多
关键词 ultra performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS) OLEUROPEIN COSMETICS
下载PDF
Dimension-Enhanced Ultra-High Performance Liquid Chromatography/Ion Mobility-Quadrupole Time-of-Flight Mass Spectrometry Combined with Intelligent Peak Annotation for the Rapid Characterization of the Multiple Components from Seeds of Descurainia sophia 被引量:1
2
作者 Simiao Wang Xue Li +7 位作者 Boxue Chen Shitong Li Jiali Wang Jing Wang Mingshuo Yang Xiaoyan Xu Hongda Wang Wenzhi Yang 《Phyton-International Journal of Experimental Botany》 SCIE 2022年第3期541-567,共27页
The complex composition of herbal metabolites necessitates the development of powerful analytical techniques aimed to identify the bioactive components.The seeds of Descurainia sophia(SDS)are utilized in China as a co... The complex composition of herbal metabolites necessitates the development of powerful analytical techniques aimed to identify the bioactive components.The seeds of Descurainia sophia(SDS)are utilized in China as a cough and asthma relieving agent.Herein,a dimension-enhanced integral approach,by combining ultra-high performance liquid chromatography/ion mobility-quadrupole time-of-flight mass spectrometry(UHPLC/IMQTOF-MS)and intelligent peak annotation,was developed to rapidly characterize the multicomponents from SDS.Good chromatographic separation was achieved within 38 min on a UPLC CSH C18(2.1×100 mm,1.7μm)column which was eluted by 0.1%formic acid in water(water phase)and acetonitrile(organic phase).Collision-induced dissociation-MS^(2)data were acquired by the data-independent high-definition MS^(E)(HDMS^(E))in both the negative and positive electrospray ionization modes.A major components knockout strategy was applied to improve the characterization of those minor ingredients by enhancing the injection volume.Moreover,a self-built chemistry library was established,which could be matched by the UNIFI software enabling automatic peak annotation of the obtained HDMS^(E)data.As a result of applying the intelligent peak annotation workflows and further confirmation process,a total of 53 compounds were identified or tentatively characterized from the SDS,including 29 flavonoids,one uridine derivative,four glucosides,one lignin,one phenolic compound,and 17 others.Notably,four-dimensional information related to the structure(e.g.,retention time,collision cross section,MS^(1)and MS^(2)data)was obtained for each component by the developed integral approach,and the results would greatly benefit the quality control of SDS. 展开更多
关键词 Descurainia sophia multicomponent characterization ultra-high performance liquid chromatography ion mobility/quadrupole time-of-flight mass spectrometry high-definition MS^(E) flavonoid
下载PDF
Determination of Ten Kinds of Alpha-2 Agonists Residues in Animal Derived Food by UHPLC-Triple Quadrupole/Composite Linear Ion Trap Mass Spectrometry
3
作者 Fang LI Xuemei LI +3 位作者 Xiangang LI Sining LIU Sha LIU Ying WANG 《Plant Diseases and Pests》 2024年第1期28-32,共5页
[Objectives]The paper was to establish an ultra high performance liquid chromatography-quadrupole/linear ion trap complex mass spectrometry for the determination of 10 kinds ofα2-receptor agonists in animal derived f... [Objectives]The paper was to establish an ultra high performance liquid chromatography-quadrupole/linear ion trap complex mass spectrometry for the determination of 10 kinds ofα2-receptor agonists in animal derived food.[Methods]The samples were extracted with sodium carbonate buffer solution and ethyl acetate,and analyzed by mass spectrometry after solid phase extraction and high performance liquid chromatography separation.[Results]Ten kinds ofα2-receptor agonists showed a good linear relationship in the range of 1-100μg/mL,with the average recovery of over 69%and the relative standard deviation less than 8.32%.The detection limit of 10 kinds of α_(2)-receptor agonists was up to 1μg/kg.[Conclusions]The method has good selectivity and strong anti-interference ability,and can meet the requirements of 10 kinds ofα2-receptor agonists residues in animal derived food. 展开更多
关键词 Animal derived food α_(2)-receptor agonist Solid-phase extraction ultra-high performance liquid phase-triple quadrupole/linear ion trap composite mass spectrometry
下载PDF
Lysophosphatidylcholine Biomarkers of Lung Cancer Detected by Ultra-performance Liquid Chromatography Coupled with Quadrupole Time-of-flight Mass Spectrometry
4
作者 DONG Jun CAI Xiao-ming +4 位作者 ZOU Li-juan CHEN Cheng XUE Xing-ya ZHANG Xiu-li LIANG Xin-miao 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第5期750-755,共6页
Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients a... Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients and 34 healthy volunteers were prepared with this approach. With ultra-performance liquid chromatography(UPLC) coupled with quadrupole time-of-flight mass spectrometry(Q-TOF MS) analysis, the samples were investigated in order to find potential disease biomarkers. After data acquisition, orthogonal signal correction partial least squares models were built to differentiate the healthy volunteers from lung cancer patients and to identify metabolites that showed significantly different expression between the two groups. Several metabolite ions were identified as potential biomarkers according to the variable importance in the project(VIP) value in both ion modes. Five lysophosphatidylcholines were further identified as specifically lysoPC 16:0, isomer of lysoPC 16:0, lysoPC 18:0, lysoPC 18:1 and lysoPC 18:2. These results suggest that UPLC coupled with Q-TOF MS is an effective technique for the analysis of plasma metabolites in metabonomic studies. 展开更多
关键词 METABONOMICS Sample preparation ultra-performance liquid chromatography coupled with quadrupoletime-of-flight mass spectrometry(UPLC/Q-TOF MS) Lung cancer Biomarker
下载PDF
Screening for Plant Toxins in Honey and Herbal Beverage by Ultrahigh-Performance Liquid Chromatography-Ion Mobility-Quadrupole Time of Flight Mass Spectrometry
5
作者 Qiaozhen Guo Yi Yang +2 位作者 Jiang Li Bing Shao Jing Zhang 《American Journal of Analytical Chemistry》 2022年第3期108-134,共27页
The standards of plant toxins were separated by a C18 column with gradient elution with 0.1% formic acid/water (V/V) and 0.1% formic acid/acetonitrile (V/V) as mobile phase and acquired by ion mobility-quadrupole time... The standards of plant toxins were separated by a C18 column with gradient elution with 0.1% formic acid/water (V/V) and 0.1% formic acid/acetonitrile (V/V) as mobile phase and acquired by ion mobility-quadrupole time of flight mass spectrometry (IM-QTOF MS) in positive ion mode. A database of 308 plant toxins including retention time, collision cross-section (CCS) and its fragment ions was established. Honey dissolved in water or herbal beverage was extracted by acetonitrile and purified with PSA sorbent, and then acquired by ultrahigh-performance liquid chromatography IM-QTOFMS. The acquired data were processed by comparing with the database we established to confirm the target compounds. The average recoveries for samples at two levels ranged from 60.6% - 120.1%, with relative standard deviation (n = 6) less than 25%. The limit of quantitation for plant toxins ranged from 1 - 20 μg/kg. The developed screening method was used in determination of honey, herbal beverage and honey flavored tea beverage samples. The results showed that berberine was detected in one honey with 1 μg/kg and caffeine was present in some beverages with the concentration from 200 and 5500 μg/kg. This method could meet the requirement for rapid screening of plant toxins in honey and herbal beverage. It can be used for the quality control of honey and herbal beverage in enterprises or quality inspection departments. It also can be used in the rapid screening of food poisoning. 展开更多
关键词 SCREENING Plant Toxins HONEY Herbal Beverage ultrahigh-performance liquid Chromatography ion Mobility-quadrupole time of Flight mass spectrometry
下载PDF
Simultaneous Determination of Bisphenols and Alkylphenols in Water by Solid Phase Extraction and Ultra Performance Liquid Chromatography-tandem Mass Spectrometry 被引量:4
6
作者 SHAN Xiao Mei SHEN Deng Hui +2 位作者 WANG Bing Shuang LU Bei Bei HUANG Fa Yuan 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第6期471-474,共4页
To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry ... To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%. 展开更多
关键词 UPLC BPA Simultaneous Determination of Bisphenols and Alkylphenols in Water by Solid Phase Extraction and ultra performance liquid Chromatography-tandem mass spectrometry mass
下载PDF
Determination of Steroid Hormone Residues in Fish Tissues Using Gel Permeation Chromatography and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry 被引量:3
7
作者 LI Peipei YAN Zhongyong +3 位作者 SUN Xiumei CHEN Si CHEN Yin ZHANG Xiaojun 《Journal of Ocean University of China》 SCIE CAS CSCD 2018年第5期1171-1177,共7页
A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 s... A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues. 展开更多
关键词 ultra performance liquid chromatography-tandem mass spectrometry anabolic hormone gel permeation chromatography fish tissue
下载PDF
Uncertainty Evaluation of Determination of Microcystin MC-LR in Environmental Samples by Solid Phase Extraction-Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry 被引量:1
8
作者 Zhao Bin Zhang Min Zhang Fuhai 《Meteorological and Environmental Research》 CAS 2016年第6期54-57,共4页
To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated first... To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2). 展开更多
关键词 Uncertainty SOLID phase extraction ultra performance liquid CHROMATOGRAPHY TANDEM mass spectrometry MICROCYSTIN MC-LR China
下载PDF
Chemical Components of Achyranthes bidentata Leaves by Ultra High Performance Liquid Chromatography-Mass Spectrometry 被引量:1
9
作者 Haiyang DONG Jinshuo MA Fulin YAN 《Medicinal Plant》 CAS 2019年第4期16-19,共4页
[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical c... [Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical components of A. bidentata leaves were rapidly analyzed using the ultra high performance liquid chromatography-time of flight-high resolution mass spectrometry (UHPLC-TOF-MS).[Results] Thirty eight chemical compounds were identified in samples of A. bidentata leaves collected from Wen County of Henan Province, in which seven chemical compounds had the relative content higher than 5%, linoleic acid reached 25.7% and inokosterone A reached 13.8%.[Conclusions] A. bidentata leaves contain many kinds of chemical compounds. This study is expected to provide a certain basis for further extraction of linoleic acid and inokosterone A. 展开更多
关键词 Achyranthes bidentata LEAVES ultra high performance liquid chromatography-mass spectrometry (UHPLC-MS) Chemical components Inokosterone
下载PDF
Simultaneous Determination of Ultraviolet Absorbers and Antibacterial Agents in Textiles by Ultra-High Performance Liquid Chromatography/Orbitrap High Resolution Mass Spectrometry 被引量:1
10
作者 Chengyun Wang Tangtang Xie +2 位作者 Rong Xu Junfeng Lin Lixia Li 《World Journal of Engineering and Technology》 2017年第1期1-18,共18页
This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile sampl... This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles. 展开更多
关键词 ultra-High performance liquid Chromatography/Orbitrap High Resolution mass spectrometry Benzotriazoleultraviolet ABSORBERS Isothiazolinone Tric-losan 4-Chloro-3 5-Dimethyl Phenol
下载PDF
Rapid Determination of Three Kinds of Microcystins in Environmental Water Samples by Disk SPE-Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
11
作者 Zhao Bin Zhang Min Zhang Fuhai 《Meteorological and Environmental Research》 CAS 2016年第5期62-64,68,共4页
A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established.... A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples. 展开更多
关键词 Disk SOLID-PHASE extraction COLUMN ultra performance liquid chromatography-tandem mass spectrometry Environmental water sample MICROCYSTINS Lake Chao China
下载PDF
Determination of thyreostats in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry
12
作者 Lech RODZIEWICZ Jolanta MASLOWIECKA +1 位作者 Anna SADOWSKA Halina CAR 《色谱》 CAS CSCD 北大核心 2017年第10期1048-1054,共7页
Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC... Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine. 展开更多
关键词 ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) thyreostats (TSs) URINE
下载PDF
A Validated Liquid Chromatography-Mass Spectrometry Method for the Detection and Quantification of Oxidative Metabolites of 2,2',4,4'-Tetrabromodiphenyl Ether in Rat Hepatic Microsomes 被引量:1
13
作者 Sarah Catherine Moffatt Patrick Robert Edwards +1 位作者 András Szeitz Stelvio Mario Bandiera 《American Journal of Analytical Chemistry》 2011年第3期352-362,共11页
In the present study, we developed and validated an analytical method using ultra performance liquid chromatography-mass spectrometry (UPLC/MS) for the quantitative determination of 2,2',4,4'-tetrabromodipheny... In the present study, we developed and validated an analytical method using ultra performance liquid chromatography-mass spectrometry (UPLC/MS) for the quantitative determination of 2,2',4,4'-tetrabromodiphenyl ether (BDE-47) metabolism by rat hepatic microsomes. BDE-47 is a brominated flame retardant that was widely used in a variety of consumer products and has subsequently been identified as a ubiquitous environmental contaminant. Hydroxy-bromodiphenyl ethers (OH-BDEs) were isolated from rat hepatic microsomes by liquid-liquid extraction. Chromatographic separation was achieved by UPLC on a C18 column with gradient elution using a mobile phase consisting of methanol and water, each containing 0.1% formic acid, at a flow rate of 0.2 mL/min. Detection and quantification were performed using a mass spectrometer in single ion recording mode with negative electrospray ionization. The UPLC/MS method was validated for linearity, limit of quantification (LOQ), accuracy, precision and recovery. The weighted calibration curves (1/X2) were linear over a concentration range of 5 - 250 nM with LOQ values between 5 nM and 50 nM for the individual OH-BDEs. Intra- and inter- day accuracy (%DEV) and precision (%RSD) values ranged from –11.7% to 9.5% and 5.9% to 16.5%, respectively. Recovery values of 70% to 90% were obtained for all OH-BDEs. The validated method allowed us to successfully analyze metabolite formation following incubation of BDE-47 with hepatic microsomes prepared from phenobarbital-treated rats. Results demonstrate that the UPLC/MS method has sufficient sensitivity and reproducibility to fully characterize the in vitro metabolism of BDE-47 and possibly other PBDEs. 展开更多
关键词 BDE-47 HEPATIC Metabolism Polybrominated DIPHENYL ETHERS RAT HEPATIC MICROSOMES ultra performance liquid Chromatography-mass spectrometry
下载PDF
GLOBAL ANALYSIS OF THE METABOLITES OF CURCUMIN IN RATS BY ULTRA PERFORMANCE LIQUID CHROMATOGRAPHY COUPLED WITH QUADRUPOLE TIME OF-FLIGHT TANDEM MASS SPECTROMETRY
14
作者 Feng Qiu Tianyi Qiu +2 位作者 Yang Yu Liqin Ding Xinchi Feng 《World Journal of Traditional Chinese Medicine》 2015年第4期100-101,共2页
Curcumin,a safe natural yellow pigment with a wide range of pharmacological activities,is used both in herbal drugs and as a food coloring agents.Studies have shown that curcumin would suffer from extensive metabolism... Curcumin,a safe natural yellow pigment with a wide range of pharmacological activities,is used both in herbal drugs and as a food coloring agents.Studies have shown that curcumin would suffer from extensive metabolism in vivoand the predominant metabolic pathways are reduction and conjugation.In order to comprehensively study the metabolism and enrich the metabolic profile of cxurcumin in vivo,we carried out this research.A systematic method with highly sensitive UPLC-Q/TOF-MS was established to analyze different biological samples of rats after 展开更多
关键词 GLOBAL ANALYSIS OF THE METABOLITES OF CURCUMIN IN RATS BY ultra performance liquid CHROMATOGRAPHY COUPLED WITH quadrupole TIME OF-FLIGHT TANDEM mass spectrometry
原文传递
UHPLC-Quadrupole/Orbitrap MS同步检测十字花科植物中的游离氨基酸 被引量:1
15
作者 沈丽 王超 +1 位作者 陈静 杨雪 《分析测试学报》 CAS CSCD 北大核心 2017年第9期1093-1098,共6页
采用超高效液相色谱-四极杆/静电场轨道阱高分辨质谱联用技术(UHPLC-Quadrupole/Orbitrap MS)结合柱前衍生法建立了可同时测定28种游离氨基酸的分析方法,并对十字花科植物中的游离氨基酸进行检测和分析。样品用超纯水提取后,经6-氨基喹... 采用超高效液相色谱-四极杆/静电场轨道阱高分辨质谱联用技术(UHPLC-Quadrupole/Orbitrap MS)结合柱前衍生法建立了可同时测定28种游离氨基酸的分析方法,并对十字花科植物中的游离氨基酸进行检测和分析。样品用超纯水提取后,经6-氨基喹啉基-N-羟基琥珀酰亚胺基甲酸酯(AQC)衍生,采用Waters BEH C18柱作为色谱柱,以pH 5.0乙酸铵缓冲溶液和80%乙腈水溶液作为流动相进行梯度洗脱。质谱检测器采用电喷雾离子源,在正离子模式下进行检测。实验结果表明,十字花科植物中含有25种以上游离氨基酸,其中包括人体必需的8种氨基酸。25种氨基酸在线性范围内相关性良好,平均加标回收率为80.5%~104.4%,相对标准偏差为0.6%~4.4%。不同氨基酸检测灵敏度不同,定量下限为0.01~1.45μmol/L。该方法杂质干扰小,分析速度快,灵敏度高,适用于植物样品中游离氨基酸的同步检测。 展开更多
关键词 超高效液相色谱 高分辨质谱 游离氨基酸 十字花科植物
下载PDF
Study of Serum Metabonomics and Formula-Pattern Correspondence in Coronary Heart Disease Patients Diagnosed as Phlegm or Blood Stasis Pattern Based on Ultra Performance Liquid Chromatography Mass Spectrometry 被引量:13
16
作者 LU Xiao-yan XU Hao +1 位作者 ZHAO Tie LI Geng 《Chinese Journal of Integrative Medicine》 SCIE CAS CSCD 2018年第12期905-911,共7页
Objectives: To study the characteristics of serum metabonomics in coronary heart disease (CHD) patients diagnosed as phlegm or blood stasis pattern and explore effects of formula-pattern correspondence treatment. M... Objectives: To study the characteristics of serum metabonomics in coronary heart disease (CHD) patients diagnosed as phlegm or blood stasis pattern and explore effects of formula-pattern correspondence treatment. Methods: A total of 102 stable CHD patients were enrolled and divided into phlegm group (P group, n=52) and blood stasis group (BS group, n=50) according to pattern identification. Gualou Xiebai Banxia Decoction (瓜萎薤白半夏汤, GXBD) and Xuefu Zhuyu Decoction (血府逐瘀汤, XZD) were used as drug interventions. Relevant indicators of metabonomics were observed by ultra performance liquid chromatography mass spectrometry (UPLC-MS) and pattern recognition. Results: Levels of amino acids and phosphatidylethanolamine (PE) in the CHD group were much higher than those in healthy control group, while the levels of unsaturated fatty acids, sphingosine, Lyso, phosphatidylcholine (PC) were significantly lower (P〈0.01). Most of the differential metabolites between the CHD and the healthy groups were also common metabolites of phlegm and blood stasis. 7(Z), 10(Z)- hexadecadienoic acid and DPA were decreased in the P group and increased in the BS group. According to the quantity of retraced metabolites, improvement in metabonomics by formula-pattern correspondence was superior to that without correspondence in the BS group. Based on the varieties of metabolites, GXBD could improve the levels of docosapentaenoic acid (DPA), sphingomyelin (SM) (d34:1), and L-Lactic acid and XZD could ameliorate the levels of sphingosine and Vit E in the P group, in the BS group, GXBD could improve vitamin E level and XZD could make improvements in the levels of octadecanoic acid, phosphoglycerol, and SM (d34:1). Conclusions: Phlegm and blood stasis in CHD patients present specific differential metabolites, and share common metabolites. Remarkable differences have been displayed in pathological properties and severity of phlegm and blood stasis. Patients with phlegm are more likely to have lipid metabolism disorders. However, in patients with blood stasis, problems mainly lie in glucose, protein and fat metabolism and the injury of vascular cell membrane is relatively severe. The metabolic disorder is more complicated in blood stasis pattem than that in phlegm pattem. Compared with non-correspondence, improvement of differential metabolites is more comprehensive and targeted in formulapattern correspondence with a better effect. 展开更多
关键词 ultra performance liquid chromatography mass spectrometry METABONOMICS phlegm/stasis pattern in coronary heart disease disease-pattern combination formula-pattern correspondence
原文传递
Detecting N-nitrosamines in water treatment plants and distribution systems in China using ultra-performance liquid chromatography-tandem mass spectrometry 被引量:11
17
作者 Chengkun WANG Xiaojian ZHANG +1 位作者 Jun WANG Chao CHEN 《Frontiers of Environmental Science & Engineering》 SCIE EI CAS CSCD 2012年第6期770-777,共8页
N-nitrosodimethylamine (NDMA) and several other N-nitrosamines have been detected as disinfection by-products in drinking waters in many countries around the world. An ultra-performance liquid chromatography- tandem... N-nitrosodimethylamine (NDMA) and several other N-nitrosamines have been detected as disinfection by-products in drinking waters in many countries around the world. An ultra-performance liquid chromatography- tandem mass spectrometry method with solid phase extraction sample preparation was developed to study the occurrence of N-nitrosamines in several water treatment plants and distribution systems in China. Isotope labeled N-nitrosodi-n-propylamine-dl4 (NDPA-dl4) was selected as the internal standard for quantification. The solid phase extraction procedures including pH, enrichment process and MS/MS parameters including capillary voltage, cone gas flow, cone voltage, collision energy were optimized to give average recoveries of 26% to 112% for nine N- nitrosamine species. The instrument detection limits were estimated to range from 0.5 to 5μg.L-1 for the nine N- nitrosamine species. NDMA and several other N-nitrosa- mines were found at fairly high concentrations in several water treatment plants and distribution systems. NDMA was found in all locations, and the highest concentrations in cities B, G, T, and W were 3.0, 35.7, 21.3, and 19.7 ng. L 1, respectively. A wide range of N-nitrosamines concentrations and species were observed in different locations. Higher concentrations of N-nitrosamines were detected in distribution systems that were further away from the treatment plants, suggesting that the contact time between the residual disinfectant and natural organic matter may play an important role in the formation of these compounds. 展开更多
关键词 N-NITROSAMINES water treatment plant distri-bution system ultra-performance liquid chromatography-tandem mass spectrometry
原文传递
Simultaneous Determination of Six Compounds in Rat Plasma by Ultra-Performance Liquid Chromatography with Tandem Mass Spectrometry: Application in the Pharmacokinetic Study of Qing Gan-Shu Yu-Fang 被引量:1
18
作者 Hai Jiang A-Jiao Houa +10 位作者 Yan-Yan Zhang Wen-Jing Man Liu Yang Yong-Hai Meng Xin-Yue Guo Song Wang Jia-Xu Zhang Bing-You Yang Qiu-Hong Wang Kelvin Chan Hai-Xue Kuang 《World Journal of Traditional Chinese Medicine》 2019年第4期250-259,共10页
A rapid and high selective ultra-performance liquid chromatography(UPLC)with tandem mass spectrometry method for simultaneous determination of six compounds including albiflorin,paeoniflorin,picroside I,picroside II,s... A rapid and high selective ultra-performance liquid chromatography(UPLC)with tandem mass spectrometry method for simultaneous determination of six compounds including albiflorin,paeoniflorin,picroside I,picroside II,saikosaponin A,and saikosaponin D in rat plasma was developed and validated using butyl p-hydroxybenzoate as an internal standard.One-step direct protein precipitation with acetonitrile was used to extract the compounds from the rat plasma samples.Chromatographic separation was achieved using an ACQUITY UPLC BEH C18 column(100 mm×2.1 mm,1.7μm)at a flow rate of 0.4 m L/min,using gradient mode containing 0.1%formic acid in water and acetonitrile were used as the Mobile phase A and B.Electrospray ionization in negative ion mode and multiple reaction monitoring were used to identify and quantify active components.Calibration curves showed good linearity(R^2>0.9908)over a wide concentration range for all compounds.The intra-and interday precision(relative standard deviation)ranged 2.4%–7.0%and 2.6%–8.0%,respectively.The accuracy(relative error)was from-13.0%to 13.2%at all quality control levels.The recovery ranged from 81.1%to 92.5%.The validated method was successfully applied to pharmacokinetic study in rats after oral administration of Qing Gan-Shu Yu-Fang.The results show that one can draw a conclusion that these six active ingredients can be quickly absorbed and play a pharmacodynamic role rapidly in vivo. 展开更多
关键词 PHARMACOKINETICS traditional Chinese medicine prescriptions ultra-performance liquid chromatography with tandem mass spectrometry
原文传递
Analysis of hydroxylated polybrominated diphenyl ethers in plant samples using ultra performance liquid chromatography-mass spectrometry
19
作者 WANG Sen WU Tong +3 位作者 HUANG HongLin PING Hua LU AnXiang ZHANG ShuZhen 《Science China Chemistry》 SCIE EI CAS 2011年第11期1782-1788,共7页
A method was developed for the analysis of hydroxylated brominated diphenyl ethers (OH-PBDEs) in plant samples using an ultra performance liquid chromatography-triple quadrupole mass spectrometer (UPLC-ESI-MS/MS) in n... A method was developed for the analysis of hydroxylated brominated diphenyl ethers (OH-PBDEs) in plant samples using an ultra performance liquid chromatography-triple quadrupole mass spectrometer (UPLC-ESI-MS/MS) in negative mode. Plant samples were extracted and cleaned up through florisil column, resolved on a 100 mm C18 column with linear gradient elution and detected by mass spectrometry in multiple reaction monitoring (MRM) mode. The method provided good recoveries rang- ing from 68.2% to 94.6%, relative standard deviation (RSD) in the range of 3.2% - 9.1%, and limits of quantification (LOQ) defined as the signal-to-noise ratio of 10 of 0.3-2.1 ng/g. It allowed a fast separation and sensitive quantification of the isomers and homologues of seven OH-PBDE congeners 2′-OH-BDE-3, 3′-OH-BDE-7, 4′-OH-BDE-17, 3′-OH-BDE-28, 3-OH-BDE-47, 5-OH-BDE-47 and 6-OH-BDE-47. The method was successfully applied to identify and quantify the formation of hydroxylat- ed metabolites in alfalfa exposed to BDE-209. Five OH-PBDEs were detected in plant tissues, and more congeners were found in roots than in shoots. To our knowledge, this work represents the first attempt to validate UPLC-MS/MS method to quantify OH-PBDEs in plant samples without derivatization. 展开更多
关键词 OH-PBDE plant extraction ultra performance liquid chromatography mass spectrometry
原文传递
Rapid Determination of Tetrodotoxin in Human Plasma by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
20
作者 CHEN Weizhu ZHANG Yiping +3 位作者 SUN Jipeng XIE Quanling HONG Zhuan YI Ruizao 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2018年第6期905-911,共7页
A sensitive analytical method was developed to determine tetrodotoxin(TTX) in human plasma samples using protein precipitation, followed by ultra performance liquid chromatography(UPLC) analysis coupled with tande... A sensitive analytical method was developed to determine tetrodotoxin(TTX) in human plasma samples using protein precipitation, followed by ultra performance liquid chromatography(UPLC) analysis coupled with tandem mass spectrometry(MS/MS) using 11-deoxytetrodotoxin(11-deoxyTTX) as an internal standard. The plasma samples were prepared using protein precipitation prior to being analyzed by UPLC-MSfMS to identify TTX over a zwitterionic-hydrophilic interaction liquid chromatography column. The retention time values of TTX and 11-deoxyTTX were 4.12 and 3.67 min, respectively. TTX and 11-deoxyTTX were monitored and quantitated on the basis of their ion transitions for their respective precursor ions to their product ions(i.e., m/z 320.0→162. l for TTX and m/z 304.0→176.0 for 11-deoxyTTX) in the multiple reaction-monitoring mode. The lower limit of quantification of this method was determined to be 0.0199 ug/mL. This method showed good linearity for plasma samples that contained TTX concentrations in the range of 0.0199--1.99 ng/mL. The specificity, precision, accuracy, matrix effect, and stability characteristics of this method were also examined. The intra-assay precision and accuracy ranged from 1.89% to 6.00% and from 92.21% to 100.00%, whereas the inter-assay precision and accuracy ranged from 0.64% to 7.75% and from 99.38% to 101.26%, respectively. This new method therefore represents a rapid, accurate, reliable, and highly sensitive method for the qualitative and quantitative analyses of a trace amount of TTX in human plasma samples. 展开更多
关键词 Tetrodotoxin(TTX) 11-DeoxyTTX ultra performance liquid chromatography(UPLC)coupled with tandem mass spectrometry(MS/MS) PLASMA Protein precipitation
原文传递
上一页 1 2 232 下一页 到第
使用帮助 返回顶部