An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracte...An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics.展开更多
The complex composition of herbal metabolites necessitates the development of powerful analytical techniques aimed to identify the bioactive components.The seeds of Descurainia sophia(SDS)are utilized in China as a co...The complex composition of herbal metabolites necessitates the development of powerful analytical techniques aimed to identify the bioactive components.The seeds of Descurainia sophia(SDS)are utilized in China as a cough and asthma relieving agent.Herein,a dimension-enhanced integral approach,by combining ultra-high performance liquid chromatography/ion mobility-quadrupole time-of-flight mass spectrometry(UHPLC/IMQTOF-MS)and intelligent peak annotation,was developed to rapidly characterize the multicomponents from SDS.Good chromatographic separation was achieved within 38 min on a UPLC CSH C18(2.1×100 mm,1.7μm)column which was eluted by 0.1%formic acid in water(water phase)and acetonitrile(organic phase).Collision-induced dissociation-MS^(2)data were acquired by the data-independent high-definition MS^(E)(HDMS^(E))in both the negative and positive electrospray ionization modes.A major components knockout strategy was applied to improve the characterization of those minor ingredients by enhancing the injection volume.Moreover,a self-built chemistry library was established,which could be matched by the UNIFI software enabling automatic peak annotation of the obtained HDMS^(E)data.As a result of applying the intelligent peak annotation workflows and further confirmation process,a total of 53 compounds were identified or tentatively characterized from the SDS,including 29 flavonoids,one uridine derivative,four glucosides,one lignin,one phenolic compound,and 17 others.Notably,four-dimensional information related to the structure(e.g.,retention time,collision cross section,MS^(1)and MS^(2)data)was obtained for each component by the developed integral approach,and the results would greatly benefit the quality control of SDS.展开更多
[Objectives]The paper was to establish an ultra high performance liquid chromatography-quadrupole/linear ion trap complex mass spectrometry for the determination of 10 kinds ofα2-receptor agonists in animal derived f...[Objectives]The paper was to establish an ultra high performance liquid chromatography-quadrupole/linear ion trap complex mass spectrometry for the determination of 10 kinds ofα2-receptor agonists in animal derived food.[Methods]The samples were extracted with sodium carbonate buffer solution and ethyl acetate,and analyzed by mass spectrometry after solid phase extraction and high performance liquid chromatography separation.[Results]Ten kinds ofα2-receptor agonists showed a good linear relationship in the range of 1-100μg/mL,with the average recovery of over 69%and the relative standard deviation less than 8.32%.The detection limit of 10 kinds of α_(2)-receptor agonists was up to 1μg/kg.[Conclusions]The method has good selectivity and strong anti-interference ability,and can meet the requirements of 10 kinds ofα2-receptor agonists residues in animal derived food.展开更多
Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients a...Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients and 34 healthy volunteers were prepared with this approach. With ultra-performance liquid chromatography(UPLC) coupled with quadrupole time-of-flight mass spectrometry(Q-TOF MS) analysis, the samples were investigated in order to find potential disease biomarkers. After data acquisition, orthogonal signal correction partial least squares models were built to differentiate the healthy volunteers from lung cancer patients and to identify metabolites that showed significantly different expression between the two groups. Several metabolite ions were identified as potential biomarkers according to the variable importance in the project(VIP) value in both ion modes. Five lysophosphatidylcholines were further identified as specifically lysoPC 16:0, isomer of lysoPC 16:0, lysoPC 18:0, lysoPC 18:1 and lysoPC 18:2. These results suggest that UPLC coupled with Q-TOF MS is an effective technique for the analysis of plasma metabolites in metabonomic studies.展开更多
The standards of plant toxins were separated by a C18 column with gradient elution with 0.1% formic acid/water (V/V) and 0.1% formic acid/acetonitrile (V/V) as mobile phase and acquired by ion mobility-quadrupole time...The standards of plant toxins were separated by a C18 column with gradient elution with 0.1% formic acid/water (V/V) and 0.1% formic acid/acetonitrile (V/V) as mobile phase and acquired by ion mobility-quadrupole time of flight mass spectrometry (IM-QTOF MS) in positive ion mode. A database of 308 plant toxins including retention time, collision cross-section (CCS) and its fragment ions was established. Honey dissolved in water or herbal beverage was extracted by acetonitrile and purified with PSA sorbent, and then acquired by ultrahigh-performance liquid chromatography IM-QTOFMS. The acquired data were processed by comparing with the database we established to confirm the target compounds. The average recoveries for samples at two levels ranged from 60.6% - 120.1%, with relative standard deviation (n = 6) less than 25%. The limit of quantitation for plant toxins ranged from 1 - 20 μg/kg. The developed screening method was used in determination of honey, herbal beverage and honey flavored tea beverage samples. The results showed that berberine was detected in one honey with 1 μg/kg and caffeine was present in some beverages with the concentration from 200 and 5500 μg/kg. This method could meet the requirement for rapid screening of plant toxins in honey and herbal beverage. It can be used for the quality control of honey and herbal beverage in enterprises or quality inspection departments. It also can be used in the rapid screening of food poisoning.展开更多
To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry ...To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%.展开更多
A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 s...A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues.展开更多
To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated first...To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).展开更多
[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical c...[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical components of A. bidentata leaves were rapidly analyzed using the ultra high performance liquid chromatography-time of flight-high resolution mass spectrometry (UHPLC-TOF-MS).[Results] Thirty eight chemical compounds were identified in samples of A. bidentata leaves collected from Wen County of Henan Province, in which seven chemical compounds had the relative content higher than 5%, linoleic acid reached 25.7% and inokosterone A reached 13.8%.[Conclusions] A. bidentata leaves contain many kinds of chemical compounds. This study is expected to provide a certain basis for further extraction of linoleic acid and inokosterone A.展开更多
This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile sampl...This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles.展开更多
A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established....A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.展开更多
Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC...Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine.展开更多
In the present study, we developed and validated an analytical method using ultra performance liquid chromatography-mass spectrometry (UPLC/MS) for the quantitative determination of 2,2',4,4'-tetrabromodipheny...In the present study, we developed and validated an analytical method using ultra performance liquid chromatography-mass spectrometry (UPLC/MS) for the quantitative determination of 2,2',4,4'-tetrabromodiphenyl ether (BDE-47) metabolism by rat hepatic microsomes. BDE-47 is a brominated flame retardant that was widely used in a variety of consumer products and has subsequently been identified as a ubiquitous environmental contaminant. Hydroxy-bromodiphenyl ethers (OH-BDEs) were isolated from rat hepatic microsomes by liquid-liquid extraction. Chromatographic separation was achieved by UPLC on a C18 column with gradient elution using a mobile phase consisting of methanol and water, each containing 0.1% formic acid, at a flow rate of 0.2 mL/min. Detection and quantification were performed using a mass spectrometer in single ion recording mode with negative electrospray ionization. The UPLC/MS method was validated for linearity, limit of quantification (LOQ), accuracy, precision and recovery. The weighted calibration curves (1/X2) were linear over a concentration range of 5 - 250 nM with LOQ values between 5 nM and 50 nM for the individual OH-BDEs. Intra- and inter- day accuracy (%DEV) and precision (%RSD) values ranged from –11.7% to 9.5% and 5.9% to 16.5%, respectively. Recovery values of 70% to 90% were obtained for all OH-BDEs. The validated method allowed us to successfully analyze metabolite formation following incubation of BDE-47 with hepatic microsomes prepared from phenobarbital-treated rats. Results demonstrate that the UPLC/MS method has sufficient sensitivity and reproducibility to fully characterize the in vitro metabolism of BDE-47 and possibly other PBDEs.展开更多
Curcumin,a safe natural yellow pigment with a wide range of pharmacological activities,is used both in herbal drugs and as a food coloring agents.Studies have shown that curcumin would suffer from extensive metabolism...Curcumin,a safe natural yellow pigment with a wide range of pharmacological activities,is used both in herbal drugs and as a food coloring agents.Studies have shown that curcumin would suffer from extensive metabolism in vivoand the predominant metabolic pathways are reduction and conjugation.In order to comprehensively study the metabolism and enrich the metabolic profile of cxurcumin in vivo,we carried out this research.A systematic method with highly sensitive UPLC-Q/TOF-MS was established to analyze different biological samples of rats after展开更多
Objectives: To study the characteristics of serum metabonomics in coronary heart disease (CHD) patients diagnosed as phlegm or blood stasis pattern and explore effects of formula-pattern correspondence treatment. M...Objectives: To study the characteristics of serum metabonomics in coronary heart disease (CHD) patients diagnosed as phlegm or blood stasis pattern and explore effects of formula-pattern correspondence treatment. Methods: A total of 102 stable CHD patients were enrolled and divided into phlegm group (P group, n=52) and blood stasis group (BS group, n=50) according to pattern identification. Gualou Xiebai Banxia Decoction (瓜萎薤白半夏汤, GXBD) and Xuefu Zhuyu Decoction (血府逐瘀汤, XZD) were used as drug interventions. Relevant indicators of metabonomics were observed by ultra performance liquid chromatography mass spectrometry (UPLC-MS) and pattern recognition. Results: Levels of amino acids and phosphatidylethanolamine (PE) in the CHD group were much higher than those in healthy control group, while the levels of unsaturated fatty acids, sphingosine, Lyso, phosphatidylcholine (PC) were significantly lower (P〈0.01). Most of the differential metabolites between the CHD and the healthy groups were also common metabolites of phlegm and blood stasis. 7(Z), 10(Z)- hexadecadienoic acid and DPA were decreased in the P group and increased in the BS group. According to the quantity of retraced metabolites, improvement in metabonomics by formula-pattern correspondence was superior to that without correspondence in the BS group. Based on the varieties of metabolites, GXBD could improve the levels of docosapentaenoic acid (DPA), sphingomyelin (SM) (d34:1), and L-Lactic acid and XZD could ameliorate the levels of sphingosine and Vit E in the P group, in the BS group, GXBD could improve vitamin E level and XZD could make improvements in the levels of octadecanoic acid, phosphoglycerol, and SM (d34:1). Conclusions: Phlegm and blood stasis in CHD patients present specific differential metabolites, and share common metabolites. Remarkable differences have been displayed in pathological properties and severity of phlegm and blood stasis. Patients with phlegm are more likely to have lipid metabolism disorders. However, in patients with blood stasis, problems mainly lie in glucose, protein and fat metabolism and the injury of vascular cell membrane is relatively severe. The metabolic disorder is more complicated in blood stasis pattem than that in phlegm pattem. Compared with non-correspondence, improvement of differential metabolites is more comprehensive and targeted in formulapattern correspondence with a better effect.展开更多
N-nitrosodimethylamine (NDMA) and several other N-nitrosamines have been detected as disinfection by-products in drinking waters in many countries around the world. An ultra-performance liquid chromatography- tandem...N-nitrosodimethylamine (NDMA) and several other N-nitrosamines have been detected as disinfection by-products in drinking waters in many countries around the world. An ultra-performance liquid chromatography- tandem mass spectrometry method with solid phase extraction sample preparation was developed to study the occurrence of N-nitrosamines in several water treatment plants and distribution systems in China. Isotope labeled N-nitrosodi-n-propylamine-dl4 (NDPA-dl4) was selected as the internal standard for quantification. The solid phase extraction procedures including pH, enrichment process and MS/MS parameters including capillary voltage, cone gas flow, cone voltage, collision energy were optimized to give average recoveries of 26% to 112% for nine N- nitrosamine species. The instrument detection limits were estimated to range from 0.5 to 5μg.L-1 for the nine N- nitrosamine species. NDMA and several other N-nitrosa- mines were found at fairly high concentrations in several water treatment plants and distribution systems. NDMA was found in all locations, and the highest concentrations in cities B, G, T, and W were 3.0, 35.7, 21.3, and 19.7 ng. L 1, respectively. A wide range of N-nitrosamines concentrations and species were observed in different locations. Higher concentrations of N-nitrosamines were detected in distribution systems that were further away from the treatment plants, suggesting that the contact time between the residual disinfectant and natural organic matter may play an important role in the formation of these compounds.展开更多
A rapid and high selective ultra-performance liquid chromatography(UPLC)with tandem mass spectrometry method for simultaneous determination of six compounds including albiflorin,paeoniflorin,picroside I,picroside II,s...A rapid and high selective ultra-performance liquid chromatography(UPLC)with tandem mass spectrometry method for simultaneous determination of six compounds including albiflorin,paeoniflorin,picroside I,picroside II,saikosaponin A,and saikosaponin D in rat plasma was developed and validated using butyl p-hydroxybenzoate as an internal standard.One-step direct protein precipitation with acetonitrile was used to extract the compounds from the rat plasma samples.Chromatographic separation was achieved using an ACQUITY UPLC BEH C18 column(100 mm×2.1 mm,1.7μm)at a flow rate of 0.4 m L/min,using gradient mode containing 0.1%formic acid in water and acetonitrile were used as the Mobile phase A and B.Electrospray ionization in negative ion mode and multiple reaction monitoring were used to identify and quantify active components.Calibration curves showed good linearity(R^2>0.9908)over a wide concentration range for all compounds.The intra-and interday precision(relative standard deviation)ranged 2.4%–7.0%and 2.6%–8.0%,respectively.The accuracy(relative error)was from-13.0%to 13.2%at all quality control levels.The recovery ranged from 81.1%to 92.5%.The validated method was successfully applied to pharmacokinetic study in rats after oral administration of Qing Gan-Shu Yu-Fang.The results show that one can draw a conclusion that these six active ingredients can be quickly absorbed and play a pharmacodynamic role rapidly in vivo.展开更多
A method was developed for the analysis of hydroxylated brominated diphenyl ethers (OH-PBDEs) in plant samples using an ultra performance liquid chromatography-triple quadrupole mass spectrometer (UPLC-ESI-MS/MS) in n...A method was developed for the analysis of hydroxylated brominated diphenyl ethers (OH-PBDEs) in plant samples using an ultra performance liquid chromatography-triple quadrupole mass spectrometer (UPLC-ESI-MS/MS) in negative mode. Plant samples were extracted and cleaned up through florisil column, resolved on a 100 mm C18 column with linear gradient elution and detected by mass spectrometry in multiple reaction monitoring (MRM) mode. The method provided good recoveries rang- ing from 68.2% to 94.6%, relative standard deviation (RSD) in the range of 3.2% - 9.1%, and limits of quantification (LOQ) defined as the signal-to-noise ratio of 10 of 0.3-2.1 ng/g. It allowed a fast separation and sensitive quantification of the isomers and homologues of seven OH-PBDE congeners 2′-OH-BDE-3, 3′-OH-BDE-7, 4′-OH-BDE-17, 3′-OH-BDE-28, 3-OH-BDE-47, 5-OH-BDE-47 and 6-OH-BDE-47. The method was successfully applied to identify and quantify the formation of hydroxylat- ed metabolites in alfalfa exposed to BDE-209. Five OH-PBDEs were detected in plant tissues, and more congeners were found in roots than in shoots. To our knowledge, this work represents the first attempt to validate UPLC-MS/MS method to quantify OH-PBDEs in plant samples without derivatization.展开更多
A sensitive analytical method was developed to determine tetrodotoxin(TTX) in human plasma samples using protein precipitation, followed by ultra performance liquid chromatography(UPLC) analysis coupled with tande...A sensitive analytical method was developed to determine tetrodotoxin(TTX) in human plasma samples using protein precipitation, followed by ultra performance liquid chromatography(UPLC) analysis coupled with tandem mass spectrometry(MS/MS) using 11-deoxytetrodotoxin(11-deoxyTTX) as an internal standard. The plasma samples were prepared using protein precipitation prior to being analyzed by UPLC-MSfMS to identify TTX over a zwitterionic-hydrophilic interaction liquid chromatography column. The retention time values of TTX and 11-deoxyTTX were 4.12 and 3.67 min, respectively. TTX and 11-deoxyTTX were monitored and quantitated on the basis of their ion transitions for their respective precursor ions to their product ions(i.e., m/z 320.0→162. l for TTX and m/z 304.0→176.0 for 11-deoxyTTX) in the multiple reaction-monitoring mode. The lower limit of quantification of this method was determined to be 0.0199 ug/mL. This method showed good linearity for plasma samples that contained TTX concentrations in the range of 0.0199--1.99 ng/mL. The specificity, precision, accuracy, matrix effect, and stability characteristics of this method were also examined. The intra-assay precision and accuracy ranged from 1.89% to 6.00% and from 92.21% to 100.00%, whereas the inter-assay precision and accuracy ranged from 0.64% to 7.75% and from 99.38% to 101.26%, respectively. This new method therefore represents a rapid, accurate, reliable, and highly sensitive method for the qualitative and quantitative analyses of a trace amount of TTX in human plasma samples.展开更多
文摘An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics.
基金This work was financially supported by the National Key Research and Development Program of China(Grant No.2018YFC1704500)Tianjin Committee of Science and Technology of China(Grant No.21ZYJDJC00080)National Natural Science Foundation of China(Grant No.81872996).
文摘The complex composition of herbal metabolites necessitates the development of powerful analytical techniques aimed to identify the bioactive components.The seeds of Descurainia sophia(SDS)are utilized in China as a cough and asthma relieving agent.Herein,a dimension-enhanced integral approach,by combining ultra-high performance liquid chromatography/ion mobility-quadrupole time-of-flight mass spectrometry(UHPLC/IMQTOF-MS)and intelligent peak annotation,was developed to rapidly characterize the multicomponents from SDS.Good chromatographic separation was achieved within 38 min on a UPLC CSH C18(2.1×100 mm,1.7μm)column which was eluted by 0.1%formic acid in water(water phase)and acetonitrile(organic phase).Collision-induced dissociation-MS^(2)data were acquired by the data-independent high-definition MS^(E)(HDMS^(E))in both the negative and positive electrospray ionization modes.A major components knockout strategy was applied to improve the characterization of those minor ingredients by enhancing the injection volume.Moreover,a self-built chemistry library was established,which could be matched by the UNIFI software enabling automatic peak annotation of the obtained HDMS^(E)data.As a result of applying the intelligent peak annotation workflows and further confirmation process,a total of 53 compounds were identified or tentatively characterized from the SDS,including 29 flavonoids,one uridine derivative,four glucosides,one lignin,one phenolic compound,and 17 others.Notably,four-dimensional information related to the structure(e.g.,retention time,collision cross section,MS^(1)and MS^(2)data)was obtained for each component by the developed integral approach,and the results would greatly benefit the quality control of SDS.
基金Supported by Scientific Research Project of Dalian Customs(2022DK09).
文摘[Objectives]The paper was to establish an ultra high performance liquid chromatography-quadrupole/linear ion trap complex mass spectrometry for the determination of 10 kinds ofα2-receptor agonists in animal derived food.[Methods]The samples were extracted with sodium carbonate buffer solution and ethyl acetate,and analyzed by mass spectrometry after solid phase extraction and high performance liquid chromatography separation.[Results]Ten kinds ofα2-receptor agonists showed a good linear relationship in the range of 1-100μg/mL,with the average recovery of over 69%and the relative standard deviation less than 8.32%.The detection limit of 10 kinds of α_(2)-receptor agonists was up to 1μg/kg.[Conclusions]The method has good selectivity and strong anti-interference ability,and can meet the requirements of 10 kinds ofα2-receptor agonists residues in animal derived food.
基金Supported by the National Natural Science Foundation of China(No.30801513)the Knowledge Innovation Program of Chinese Academy of Sciences(No.KSCX2-YW-R-170)
文摘Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients and 34 healthy volunteers were prepared with this approach. With ultra-performance liquid chromatography(UPLC) coupled with quadrupole time-of-flight mass spectrometry(Q-TOF MS) analysis, the samples were investigated in order to find potential disease biomarkers. After data acquisition, orthogonal signal correction partial least squares models were built to differentiate the healthy volunteers from lung cancer patients and to identify metabolites that showed significantly different expression between the two groups. Several metabolite ions were identified as potential biomarkers according to the variable importance in the project(VIP) value in both ion modes. Five lysophosphatidylcholines were further identified as specifically lysoPC 16:0, isomer of lysoPC 16:0, lysoPC 18:0, lysoPC 18:1 and lysoPC 18:2. These results suggest that UPLC coupled with Q-TOF MS is an effective technique for the analysis of plasma metabolites in metabonomic studies.
文摘The standards of plant toxins were separated by a C18 column with gradient elution with 0.1% formic acid/water (V/V) and 0.1% formic acid/acetonitrile (V/V) as mobile phase and acquired by ion mobility-quadrupole time of flight mass spectrometry (IM-QTOF MS) in positive ion mode. A database of 308 plant toxins including retention time, collision cross-section (CCS) and its fragment ions was established. Honey dissolved in water or herbal beverage was extracted by acetonitrile and purified with PSA sorbent, and then acquired by ultrahigh-performance liquid chromatography IM-QTOFMS. The acquired data were processed by comparing with the database we established to confirm the target compounds. The average recoveries for samples at two levels ranged from 60.6% - 120.1%, with relative standard deviation (n = 6) less than 25%. The limit of quantitation for plant toxins ranged from 1 - 20 μg/kg. The developed screening method was used in determination of honey, herbal beverage and honey flavored tea beverage samples. The results showed that berberine was detected in one honey with 1 μg/kg and caffeine was present in some beverages with the concentration from 200 and 5500 μg/kg. This method could meet the requirement for rapid screening of plant toxins in honey and herbal beverage. It can be used for the quality control of honey and herbal beverage in enterprises or quality inspection departments. It also can be used in the rapid screening of food poisoning.
基金supported by the Preventive medicine and public health research project of Anhui,China(No.2011Y0103)the Natural Science Foundation of Anhui,China(No.11040606M216)
文摘To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%.
基金supported by the Natural Science Foundation of Zhejiang Province,China(No.LY17C200009)the Foundation of Zhejiang Educational Committee(No.Y201328477)
文摘A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues.
文摘To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).
基金Supported by Key Scientific and Technological Research Project in Higher Education Institutions of Henan Province(17A350002)Project of National Natural Science Foundation of China(81172953)
文摘[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical components of A. bidentata leaves were rapidly analyzed using the ultra high performance liquid chromatography-time of flight-high resolution mass spectrometry (UHPLC-TOF-MS).[Results] Thirty eight chemical compounds were identified in samples of A. bidentata leaves collected from Wen County of Henan Province, in which seven chemical compounds had the relative content higher than 5%, linoleic acid reached 25.7% and inokosterone A reached 13.8%.[Conclusions] A. bidentata leaves contain many kinds of chemical compounds. This study is expected to provide a certain basis for further extraction of linoleic acid and inokosterone A.
文摘This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles.
文摘A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.
文摘Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine.
文摘In the present study, we developed and validated an analytical method using ultra performance liquid chromatography-mass spectrometry (UPLC/MS) for the quantitative determination of 2,2',4,4'-tetrabromodiphenyl ether (BDE-47) metabolism by rat hepatic microsomes. BDE-47 is a brominated flame retardant that was widely used in a variety of consumer products and has subsequently been identified as a ubiquitous environmental contaminant. Hydroxy-bromodiphenyl ethers (OH-BDEs) were isolated from rat hepatic microsomes by liquid-liquid extraction. Chromatographic separation was achieved by UPLC on a C18 column with gradient elution using a mobile phase consisting of methanol and water, each containing 0.1% formic acid, at a flow rate of 0.2 mL/min. Detection and quantification were performed using a mass spectrometer in single ion recording mode with negative electrospray ionization. The UPLC/MS method was validated for linearity, limit of quantification (LOQ), accuracy, precision and recovery. The weighted calibration curves (1/X2) were linear over a concentration range of 5 - 250 nM with LOQ values between 5 nM and 50 nM for the individual OH-BDEs. Intra- and inter- day accuracy (%DEV) and precision (%RSD) values ranged from –11.7% to 9.5% and 5.9% to 16.5%, respectively. Recovery values of 70% to 90% were obtained for all OH-BDEs. The validated method allowed us to successfully analyze metabolite formation following incubation of BDE-47 with hepatic microsomes prepared from phenobarbital-treated rats. Results demonstrate that the UPLC/MS method has sufficient sensitivity and reproducibility to fully characterize the in vitro metabolism of BDE-47 and possibly other PBDEs.
基金partly supported by National Natural Science Foundation of China(No.81430095)also by Special National Program on Key Basic Research Project(No.2014CB560706)
文摘Curcumin,a safe natural yellow pigment with a wide range of pharmacological activities,is used both in herbal drugs and as a food coloring agents.Studies have shown that curcumin would suffer from extensive metabolism in vivoand the predominant metabolic pathways are reduction and conjugation.In order to comprehensively study the metabolism and enrich the metabolic profile of cxurcumin in vivo,we carried out this research.A systematic method with highly sensitive UPLC-Q/TOF-MS was established to analyze different biological samples of rats after
基金Supported by the National Natural Science Foundation of China(No.30901891)
文摘Objectives: To study the characteristics of serum metabonomics in coronary heart disease (CHD) patients diagnosed as phlegm or blood stasis pattern and explore effects of formula-pattern correspondence treatment. Methods: A total of 102 stable CHD patients were enrolled and divided into phlegm group (P group, n=52) and blood stasis group (BS group, n=50) according to pattern identification. Gualou Xiebai Banxia Decoction (瓜萎薤白半夏汤, GXBD) and Xuefu Zhuyu Decoction (血府逐瘀汤, XZD) were used as drug interventions. Relevant indicators of metabonomics were observed by ultra performance liquid chromatography mass spectrometry (UPLC-MS) and pattern recognition. Results: Levels of amino acids and phosphatidylethanolamine (PE) in the CHD group were much higher than those in healthy control group, while the levels of unsaturated fatty acids, sphingosine, Lyso, phosphatidylcholine (PC) were significantly lower (P〈0.01). Most of the differential metabolites between the CHD and the healthy groups were also common metabolites of phlegm and blood stasis. 7(Z), 10(Z)- hexadecadienoic acid and DPA were decreased in the P group and increased in the BS group. According to the quantity of retraced metabolites, improvement in metabonomics by formula-pattern correspondence was superior to that without correspondence in the BS group. Based on the varieties of metabolites, GXBD could improve the levels of docosapentaenoic acid (DPA), sphingomyelin (SM) (d34:1), and L-Lactic acid and XZD could ameliorate the levels of sphingosine and Vit E in the P group, in the BS group, GXBD could improve vitamin E level and XZD could make improvements in the levels of octadecanoic acid, phosphoglycerol, and SM (d34:1). Conclusions: Phlegm and blood stasis in CHD patients present specific differential metabolites, and share common metabolites. Remarkable differences have been displayed in pathological properties and severity of phlegm and blood stasis. Patients with phlegm are more likely to have lipid metabolism disorders. However, in patients with blood stasis, problems mainly lie in glucose, protein and fat metabolism and the injury of vascular cell membrane is relatively severe. The metabolic disorder is more complicated in blood stasis pattem than that in phlegm pattem. Compared with non-correspondence, improvement of differential metabolites is more comprehensive and targeted in formulapattern correspondence with a better effect.
文摘N-nitrosodimethylamine (NDMA) and several other N-nitrosamines have been detected as disinfection by-products in drinking waters in many countries around the world. An ultra-performance liquid chromatography- tandem mass spectrometry method with solid phase extraction sample preparation was developed to study the occurrence of N-nitrosamines in several water treatment plants and distribution systems in China. Isotope labeled N-nitrosodi-n-propylamine-dl4 (NDPA-dl4) was selected as the internal standard for quantification. The solid phase extraction procedures including pH, enrichment process and MS/MS parameters including capillary voltage, cone gas flow, cone voltage, collision energy were optimized to give average recoveries of 26% to 112% for nine N- nitrosamine species. The instrument detection limits were estimated to range from 0.5 to 5μg.L-1 for the nine N- nitrosamine species. NDMA and several other N-nitrosa- mines were found at fairly high concentrations in several water treatment plants and distribution systems. NDMA was found in all locations, and the highest concentrations in cities B, G, T, and W were 3.0, 35.7, 21.3, and 19.7 ng. L 1, respectively. A wide range of N-nitrosamines concentrations and species were observed in different locations. Higher concentrations of N-nitrosamines were detected in distribution systems that were further away from the treatment plants, suggesting that the contact time between the residual disinfectant and natural organic matter may play an important role in the formation of these compounds.
基金supported financially by the National Natural Science Foundation of China (Grant No. 81973604, 81803690and 81703684)the Innovative Talents Funding of Heilongjiang University of Chinese Medicine(Grant No.2018RCD25)+8 种基金the National natural science foundation matching project (Grant No. 2018PT02)the National natural Science Foundation Matching Project (Grant No. 2017PT01)the Graduate Innovative Research Project Foundation of Heilongjiang University of Chinese Medicine (Grant No. 2019yjscx013)the Postdoctoral Initial Fund of Heilongjiang Provincethe University Nursing Program for Young Scholars with Creative Talents in Heilongjiang Province (Grant No. UNPYSCT2017215 and UNPYSCT2017219)the Natural Science Foundation of Heilongjiang Province (Grant No. H2015037)the Heilongjiang University of Chinese Medicine Doctoral Innovation Foundation (Grant No. 2014bs05)the Application Technology Research and Development Projects of Harbin Technology Bureau (Grant No. 2014RFQXJ149)Heilongjiang Postdoctoral Scientific Research Developmental Fund (Grant No.LBHQ16210 and LBH-Q17161)
文摘A rapid and high selective ultra-performance liquid chromatography(UPLC)with tandem mass spectrometry method for simultaneous determination of six compounds including albiflorin,paeoniflorin,picroside I,picroside II,saikosaponin A,and saikosaponin D in rat plasma was developed and validated using butyl p-hydroxybenzoate as an internal standard.One-step direct protein precipitation with acetonitrile was used to extract the compounds from the rat plasma samples.Chromatographic separation was achieved using an ACQUITY UPLC BEH C18 column(100 mm×2.1 mm,1.7μm)at a flow rate of 0.4 m L/min,using gradient mode containing 0.1%formic acid in water and acetonitrile were used as the Mobile phase A and B.Electrospray ionization in negative ion mode and multiple reaction monitoring were used to identify and quantify active components.Calibration curves showed good linearity(R^2>0.9908)over a wide concentration range for all compounds.The intra-and interday precision(relative standard deviation)ranged 2.4%–7.0%and 2.6%–8.0%,respectively.The accuracy(relative error)was from-13.0%to 13.2%at all quality control levels.The recovery ranged from 81.1%to 92.5%.The validated method was successfully applied to pharmacokinetic study in rats after oral administration of Qing Gan-Shu Yu-Fang.The results show that one can draw a conclusion that these six active ingredients can be quickly absorbed and play a pharmacodynamic role rapidly in vivo.
基金funded by the National Natural Science Foundation of China (40730740 & 20921063)the National Basic Research Program of China (2009CB421603)
文摘A method was developed for the analysis of hydroxylated brominated diphenyl ethers (OH-PBDEs) in plant samples using an ultra performance liquid chromatography-triple quadrupole mass spectrometer (UPLC-ESI-MS/MS) in negative mode. Plant samples were extracted and cleaned up through florisil column, resolved on a 100 mm C18 column with linear gradient elution and detected by mass spectrometry in multiple reaction monitoring (MRM) mode. The method provided good recoveries rang- ing from 68.2% to 94.6%, relative standard deviation (RSD) in the range of 3.2% - 9.1%, and limits of quantification (LOQ) defined as the signal-to-noise ratio of 10 of 0.3-2.1 ng/g. It allowed a fast separation and sensitive quantification of the isomers and homologues of seven OH-PBDE congeners 2′-OH-BDE-3, 3′-OH-BDE-7, 4′-OH-BDE-17, 3′-OH-BDE-28, 3-OH-BDE-47, 5-OH-BDE-47 and 6-OH-BDE-47. The method was successfully applied to identify and quantify the formation of hydroxylat- ed metabolites in alfalfa exposed to BDE-209. Five OH-PBDEs were detected in plant tissues, and more congeners were found in roots than in shoots. To our knowledge, this work represents the first attempt to validate UPLC-MS/MS method to quantify OH-PBDEs in plant samples without derivatization.
基金Supported by the National Key Research and Development Program of China(No.2016YFF0201104)the Construction of Public Service Platform for Research and Test of Marine Pilot Technology of China(No.Bhsfs009)the Project of Xiamen Southern oceanographic Center,China(No.16PFW008SF15).
文摘A sensitive analytical method was developed to determine tetrodotoxin(TTX) in human plasma samples using protein precipitation, followed by ultra performance liquid chromatography(UPLC) analysis coupled with tandem mass spectrometry(MS/MS) using 11-deoxytetrodotoxin(11-deoxyTTX) as an internal standard. The plasma samples were prepared using protein precipitation prior to being analyzed by UPLC-MSfMS to identify TTX over a zwitterionic-hydrophilic interaction liquid chromatography column. The retention time values of TTX and 11-deoxyTTX were 4.12 and 3.67 min, respectively. TTX and 11-deoxyTTX were monitored and quantitated on the basis of their ion transitions for their respective precursor ions to their product ions(i.e., m/z 320.0→162. l for TTX and m/z 304.0→176.0 for 11-deoxyTTX) in the multiple reaction-monitoring mode. The lower limit of quantification of this method was determined to be 0.0199 ug/mL. This method showed good linearity for plasma samples that contained TTX concentrations in the range of 0.0199--1.99 ng/mL. The specificity, precision, accuracy, matrix effect, and stability characteristics of this method were also examined. The intra-assay precision and accuracy ranged from 1.89% to 6.00% and from 92.21% to 100.00%, whereas the inter-assay precision and accuracy ranged from 0.64% to 7.75% and from 99.38% to 101.26%, respectively. This new method therefore represents a rapid, accurate, reliable, and highly sensitive method for the qualitative and quantitative analyses of a trace amount of TTX in human plasma samples.