Aim: To determine if there are different penile hemodynamic patterns between sildenafil non-responders and responders by using color Doppler ultrasonography. Methods: A total of 69 erectile dysfunction (ED) patien...Aim: To determine if there are different penile hemodynamic patterns between sildenafil non-responders and responders by using color Doppler ultrasonography. Methods: A total of 69 erectile dysfunction (ED) patients aged 22-79 years were enrolled into the present study. Thirty-eight (55.1%) men with ED who did not respond to four attempts of treatment with 100 mg sildenafil after re-education were classified as sildenafil non-responders. A com- bination of three vasodilator drugs, 1.25 mg papaverine, 0.4 mg phentolamine and 5 ug prostaglandin E1, was given by intracavernous injection before penile Doppler ultrasonography was carried out. The erectile response to intracavernous injection and vascular parameters including peak systolic velocity (PSV), resistance index (RI), end diastolic velocity (EDV) and cavernosa artery diameter (CD) were measured and the results between sildenafil nonresponders and responders were compared. Results: No statistical difference in vascular parameters measured by Doppler ultrasonography studies between non-responders and responders was noted. Sildenafil non-responders had a poorer penile rigidity response to intracavernous injection than responders (P 〈 0.05). Among patients with adequate PSV (〉 30 cm/s) and abnormal EDV (〉 5 cm/s), individuals in the non-responder group had fewer positive responses to intracavernous vasodilator injection than in the responder group (35.3% vs. 72.2%, P 〈 0.05). Advanced age and comorbidity with diabetes mellitus were significantly associated with sildenafil non-response (P 〈 0.05). Conclusion: Sildenafil non-responders were characterized by a poorer penile rigidity response to intracavernous injection and had an associated impaired veno-occlusive mechanism. Advanced age and comorbidity with diabetes mellitus were two common factors associated with non-response.展开更多
AIM: To estimate the detectability of anomalous connection in pancreatobiliary disease (ACPBD) cases, measuring gallbladder wall blood flow (GWBF).METHODS: In the retrospective study, we enrolled 42subjects with gallb...AIM: To estimate the detectability of anomalous connection in pancreatobiliary disease (ACPBD) cases, measuring gallbladder wall blood flow (GWBF).METHODS: In the retrospective study, we enrolled 42subjects with gallbladder wall thickening. GWBF velocity was determined as an average value of the peak velocity of color signals on the gallbladder wall, three times in each case. Based on the findings on endoscopic ultrasonography (EUS) or endoscopic retrograde cholangiopancreatography (ERCP), the 42 subjects were divided into 11 cases with ACPBD and 31 cases without ACPBD. In the prospective study, the subjects were 92 cases with gallbladder wall thickening. Using the cut-off level of the flow velocity obtained in the retrospective study, the usefulness of measuring GWBF velocity in diagnosing ACPBD was evaluated.RESULTS: In the retrospective study, imaging of GWBF was obtained in 40 of the 42 subjects. The mean GWBF velocity of the ACPBD cases was 29.4±3.9 cm/s(mean±SD), which was significantly different (P<0.0001;95% CI 5.48-13.2) from that of the without ACPBD cases(20.1±5.9 cm/s). Based on this result, we prepared a receiver operating characteristic curve, and the cut-off level appropriate for diagnosing ACPBD was estimated to be 25 cm/s. In the prospective study, GWBF was detected in 86 of the 92 subjects. Based on the EUS or ERCP findings, the 92 subjects were divided into 15 cases with ACPBD and 77 cases without ACPBD. When a cut-off level of 25 cm/s was employed, ACPBD could be diagnosed with a sensitivity of 87.0% (13/15) and a specificity of87.3% (62/71).CONCLUSION: Measurement of GWBF velocity, which is less invasive and provides objective values, is very useful for diagnosing ACPBD prior to the development of malignant tumors in cases with gallbladder wall thickening.展开更多
Objective: To observe the sonographic and hemodynamic features of hypoechoic hypertrophic lesions and hypoechoic cancer lesions in the hypertrophic prostate inner glands, in order to raise the accuracy of early diagno...Objective: To observe the sonographic and hemodynamic features of hypoechoic hypertrophic lesions and hypoechoic cancer lesions in the hypertrophic prostate inner glands, in order to raise the accuracy of early diagnosis rate for prostate cancer. Methods: 31 cases of hypoechoic hypertrophic lesions and 18 cases of hypoechoic cancer lesions in the hypertrophic prostate inner glands were observed by transrectal ultrasonography and comparatively analyze the shape, edge and the systolic peak velocity (Vs) , resistance index (RI) and pulsatility index (PI) of the lesions. Results: In contrast with hypertrophic group, the cancer group presented irregular shape and unclear edge, and obviously higher Vs, RI and PI. Conclusion: The sonographic appearance and Vs. RI. PI have important value in distinguishing hypoechoic hypertrophic lesions and hypoechoic cancer lesions in the hypertrophic prostate inner glands.展开更多
Objective: To evaluate the value of identifying and diagnosing mammary carcinoma and non-lactation mastitis lump (NLM) by multicolor Doppler ultrasonography. Methods: We compared and analyzed the examination results o...Objective: To evaluate the value of identifying and diagnosing mammary carcinoma and non-lactation mastitis lump (NLM) by multicolor Doppler ultrasonography. Methods: We compared and analyzed the examination results of 69 cases of mammary carcinoma proved by surgical pathology and 22 cases of NLM before surgery by multicolor Doppler ultra-sonography. Results: The detection rates of mammary carcinoma and NLM focus by ultrasonic examining were 100%. The shape, envelope, foul line, blood stream between sound and image of two diseases were similar. Of the two diseases, the representation with slight calcification in lump, lower echo in low echo, bloodstream distribution and resistance were different. Conclusion: By analyzing the sound and image representation of mammary lump, we find color Doppler ultrasonography has significant value in identifying and diagnosing mammary carcinoma and non-lactation mastitis lump.展开更多
OBJECTIVE: To assess the value of color Doppler ultrasonography in monitoring normal orthotopic liver transplantation and postoperative complications. METHODS: Forty-one patients after orthotopic liver transplantation...OBJECTIVE: To assess the value of color Doppler ultrasonography in monitoring normal orthotopic liver transplantation and postoperative complications. METHODS: Forty-one patients after orthotopic liver transplantation were examined by using color Doppler flow imaging to observe the hepatic blood flow and change of ultrasonography of the hepatic parenchyma and bile duct. The measured indexes included maximum blood flow velocity, time-average blood flow velocity (TAV), resistance index (RI) and diameter of the bile duct. RESULTS: Among 41 patients, 17 (41.5%) suffered from liver transplant rejection. Of the 17 patients, 13 (76.4%) showed decrease of TAV of the portal vein, 15 (88.25%) low-amplitude single-phase serrated wave or negative biphasic wave of the hepatic vein, 9 (52.9%) increased hepatic arterial RI, and 5 (29.4%) slightly dilated bile duct. Sonography showed disappearance of the hepatic artery blood flow around the portal vein in 5 (12.2%) of the 41 patients with hepatic artery thrombosis in the postoperative period. Slight dilatation of the intrahepatic bile duct was found in 3 (7.3%) of the 41 patients in the early postoperational period and it normalized within 2 weeks. Ultrasonography of 20 patients (48.8%) revealed a visible dilatation of the intrahepatic bile duct, which was worsening gradually. The causes of bile duct dilatation included biliary stricture in 2 patients (10%), stone in 15 patients (75%) and others in 3 patients (15%). CONCLUSIONS: Color Doppler ultrasonography is valuable for monitoring normal liver transplantation and postoperative complications.展开更多
Graves’ disease, as known today, is an autoimmune, diffuse, chronic disease of thyroid gland, as described by Robert Graves in 1835. It presents genetic predisposition and unknown etiology evidence, which is influenc...Graves’ disease, as known today, is an autoimmune, diffuse, chronic disease of thyroid gland, as described by Robert Graves in 1835. It presents genetic predisposition and unknown etiology evidence, which is influenced in its development by several factors, including environment (dietary iodine intake, stress, drugs and infections). The disease is characterized by one or more changes: hyperthyroidism, goiter, ophthalmopathy, skin changes and pretibial myxedema, around 5% less common, and other symptoms 90% to 95%. One of the most relevant clinical practice aspects in Graves’ disease patients management is to distinguish Graves’ disease in initial phase, from other types of destructive thyrotoxicosis, in addition to evaluate therapeutic methods and efficient follow up, as well as predict early recurrence or remission of disease. Scintigraphy with pertechnetate (99 mTc) and TSH levels dosage are considered the choice for this purpose. However, they present some technical difficulties, as they are not widely available and have contraindications. In this scenario, thyroid color-flow doppler ultrasonography (US Doppler) presents a viable alternative, as a widely available, low cost, non-invasive and radiation free method, providing initial diagnosis and patients with Graves’ disease follow up. In adittion, this method is used in differential diagnosis with other causes of thyrotoxicosis in the early stage.展开更多
Objective To evaluate color Doppler ultrasonography (CDU) appearances of renal vein thrombosis (RVT) and its diagnostic value.Methods Ten patients with RVT were analyzed retrospectively. Renal structure, distributions...Objective To evaluate color Doppler ultrasonography (CDU) appearances of renal vein thrombosis (RVT) and its diagnostic value.Methods Ten patients with RVT were analyzed retrospectively. Renal structure, distributions of intrarenal flow signals, echogenicity, and flow fullness in main renal veins were observed with CDU. Resistance index (RI) was recorded from the waveforms of segmental or interlobar renal artery.Results Ten kidneys in nine patients were confirmed to have thrombus within the main renal veins, and one patient was confirmed to have thrombus within the small intrarenal veins. The appearances of the main renal vein thrombosis included full of solid echogenicity or strip echogenicity and complete or partial filling defect within the main renal veins, and absent or a few intrarenal venous flow signals in 70% of kidneys involved. The appearances of intrarenal vein thrombosis included obscure renal structure and no venous flow signal within the involved part of the kidneys. Reverse diastolic flow in the intrarenal artery had only a sensitivity of 36% (4/11); in other 7 kidneys without intrarenal arterial reverse diastolic flow, increased RI (mean, 0.84; range, 0.74-0.96) was found.Conclusion CDU is helpful for rapid clinical diagnosis and follow-up of RVT, and therefore can be the first imaging modality of choice for RVT.展开更多
One hundred and four cases of breast disease were examined by color Doppler ultrasonography (CDUS). Malignant lesions were rich in blood blow signal and 56% of +++-++++grade while benign lesions had little blood flow ...One hundred and four cases of breast disease were examined by color Doppler ultrasonography (CDUS). Malignant lesions were rich in blood blow signal and 56% of +++-++++grade while benign lesions had little blood flow signal展开更多
Purpose To analyze the sources of errors and discuss the techniques to eliminate pitfalls in detecting deep vein thrombosis (DVT) of the proximal lower extremities with color duplex ultrasonography (CDUS). Methods Six...Purpose To analyze the sources of errors and discuss the techniques to eliminate pitfalls in detecting deep vein thrombosis (DVT) of the proximal lower extremities with color duplex ultrasonography (CDUS). Methods Sixty-eight cases with initial and repeat venous CDUS of the proximal lower extremities were retrospectively reviewed. The repeat was done within 24 hours after initial CDUS scanning. Comparing repeated images to initial ones, the pitfalls and sources of error in CDUS of the proximal lower extremities were discussed. Results In total 68 repeat studies, there were 62 results as same as initials and 4 cases of false negative DVT and 2 cases of false positive DVT. Conclusion Venous CDUS in detecting DVT is observer dependent. Some pitfalls and errors can be eliminated and corrected with proper scan techniques. CDUS is the most valuable imaging modality for assessing suspected DVT in the proximal lower extremities.展开更多
Renal artery stenosis as a complication from radiation therapy is not common, but it is life threatening and needs to be corrected urgently in order to prevent renal failure even losing kidney. The diagnostic criteria...Renal artery stenosis as a complication from radiation therapy is not common, but it is life threatening and needs to be corrected urgently in order to prevent renal failure even losing kidney. The diagnostic criteria of renal artery stenosis in the adults by color duplex ultrasonography have been established, which may play an important role in screening radiation induced renal artery stenosis.展开更多
AIM: To estimate the characteristics of Color Doppler findings and the results of hepatic radionuclide angiography (HRA) in secondary Hodgkin's hepatic lymphoma. METHODS: The research included patients with a dia...AIM: To estimate the characteristics of Color Doppler findings and the results of hepatic radionuclide angiography (HRA) in secondary Hodgkin's hepatic lymphoma. METHODS: The research included patients with a diagnosis of Hodgkin's lymphoma with metastatic focal lesions in the liver and controls. Morphologic characteristics of focal liver lesions and hemodynamic parameters were examined by pulsed and Color Doppler in the portal, hepatic and splenic veins were examined. Hepatic perfusion index (HPI) estimated by HRA was calculated. was observed. Lesions were mostly hypoechoic and mixed, solitary or multiple. Some of the patients presented with dilated splenic veins and hepatofugal blood flow. A pulse wave was registered in the centre and at the margins of lymphoma. The average velocity of the pulse wave was higher at the margins (P 〉 0.05). A continuous venous wave was found only at the margins of lymphoma. There was no linear correlation between lymphoma size and velocity of pulse and continuous wave (r = 390, P 〈 0.01). HPI was significantly lower in patients with lymphomas than in controls (P 〈 0.05), pointing out increased arterial perfusion in comparison to portal perfusion. CONCLUSION: Color Doppler ultrasonography is a sensitive method for the detection of neovascularization in Hodgkin's hepatic lymphoma and estimation of its intensity. Hepatic radionuclide angiography can additionally help in the assesment of vascularisation of liver lesions.展开更多
Background Laparoscopic splenectomy (LS) is currently the standard approach for resection of a normal-sized spleen. However, this method becomes technical challenge in cases of splenomegaly due to intraoperative hem...Background Laparoscopic splenectomy (LS) is currently the standard approach for resection of a normal-sized spleen. However, this method becomes technical challenge in cases of splenomegaly due to intraoperative hemorrhage. A complete understanding of the splenic vessel anatomy is important to facilitate the difficult laparoscopic procedure. In this retrospective study, we examined the role of color Doppler flow imaging (CDFI) in splenic vessel anatomy and evaluated its value for LS. Methods Forty-eight patients who underwent splenectomy for various hematologic and autoimmune disorders from May 2004 to December 2007 were enrolled in this study. Twenty-three patients underwent preoperative CDFI examination that included examination of the anatomic type of splenic pedicle, the adjacent relationship between the splenic vessel and pancreas, and spleen size (CDFI group). In the remaining 25 patients, ultrasonic inspections of the splenic vessel were not performed (non-CDFI group). Laparoscopic splenectomies in the CDFI group were performed in accordance with the information provided by the preoperative CDFI in each patient. In the non-CDFI group, LS was performed according to the conventional method. In the CDFI group, the constituent ratios of the above-mentioned parameters by CDFI were compared with those recorded during LS using the chi square test. The effectiveness of the technique on surgery in both groups was compared with an independent sample Student's ttest. Results All laparoscopic splenectomies in both groups were performed successfully. However, 2 cases in the non-CDFI group were converted to LS with the assistance of micro-incision because the branches of the splenic vein were inadvertently torn. Two anatomic types of splenic pedicle and four different adjacent relationships between the splenic vessel and pancreas were detected by CDFI. About 80% of spleens fit the criteria of megalosplenia. There were no statistically significant differences between the constituent ratios of the parameters by CDFI and those by intraoperative telerecording in the CDFI group (χ^2=0.383, 1.072, 0.119, P=0.536, 0.784, 0.730). However, statistically significant differences were observed in the operative time ((158.70±42.51) minutes vs (200.65±47.89) minutes, P=0.003), intraoperative blood loss ((55.87±17.36) ml vs (101.83±62.21) ml, P=0.001), and recovery time of gastrointestinal function ((24.39±8.88) hours vs (30.60±9.45) hours, P=0.024) between the groups. Conclusions The individual operative route and schedule can be successfully determined on the basis of various kinds of reproducible anatomic frameworks of the spleen provided by preoperative CDFI. This technique facilitates the surgical procedure, shortens the operative time, reduces intraoperative blood loss and decreases the risk of LS in splenomegaly cases.展开更多
文摘Aim: To determine if there are different penile hemodynamic patterns between sildenafil non-responders and responders by using color Doppler ultrasonography. Methods: A total of 69 erectile dysfunction (ED) patients aged 22-79 years were enrolled into the present study. Thirty-eight (55.1%) men with ED who did not respond to four attempts of treatment with 100 mg sildenafil after re-education were classified as sildenafil non-responders. A com- bination of three vasodilator drugs, 1.25 mg papaverine, 0.4 mg phentolamine and 5 ug prostaglandin E1, was given by intracavernous injection before penile Doppler ultrasonography was carried out. The erectile response to intracavernous injection and vascular parameters including peak systolic velocity (PSV), resistance index (RI), end diastolic velocity (EDV) and cavernosa artery diameter (CD) were measured and the results between sildenafil nonresponders and responders were compared. Results: No statistical difference in vascular parameters measured by Doppler ultrasonography studies between non-responders and responders was noted. Sildenafil non-responders had a poorer penile rigidity response to intracavernous injection than responders (P 〈 0.05). Among patients with adequate PSV (〉 30 cm/s) and abnormal EDV (〉 5 cm/s), individuals in the non-responder group had fewer positive responses to intracavernous vasodilator injection than in the responder group (35.3% vs. 72.2%, P 〈 0.05). Advanced age and comorbidity with diabetes mellitus were significantly associated with sildenafil non-response (P 〈 0.05). Conclusion: Sildenafil non-responders were characterized by a poorer penile rigidity response to intracavernous injection and had an associated impaired veno-occlusive mechanism. Advanced age and comorbidity with diabetes mellitus were two common factors associated with non-response.
文摘AIM: To estimate the detectability of anomalous connection in pancreatobiliary disease (ACPBD) cases, measuring gallbladder wall blood flow (GWBF).METHODS: In the retrospective study, we enrolled 42subjects with gallbladder wall thickening. GWBF velocity was determined as an average value of the peak velocity of color signals on the gallbladder wall, three times in each case. Based on the findings on endoscopic ultrasonography (EUS) or endoscopic retrograde cholangiopancreatography (ERCP), the 42 subjects were divided into 11 cases with ACPBD and 31 cases without ACPBD. In the prospective study, the subjects were 92 cases with gallbladder wall thickening. Using the cut-off level of the flow velocity obtained in the retrospective study, the usefulness of measuring GWBF velocity in diagnosing ACPBD was evaluated.RESULTS: In the retrospective study, imaging of GWBF was obtained in 40 of the 42 subjects. The mean GWBF velocity of the ACPBD cases was 29.4±3.9 cm/s(mean±SD), which was significantly different (P<0.0001;95% CI 5.48-13.2) from that of the without ACPBD cases(20.1±5.9 cm/s). Based on this result, we prepared a receiver operating characteristic curve, and the cut-off level appropriate for diagnosing ACPBD was estimated to be 25 cm/s. In the prospective study, GWBF was detected in 86 of the 92 subjects. Based on the EUS or ERCP findings, the 92 subjects were divided into 15 cases with ACPBD and 77 cases without ACPBD. When a cut-off level of 25 cm/s was employed, ACPBD could be diagnosed with a sensitivity of 87.0% (13/15) and a specificity of87.3% (62/71).CONCLUSION: Measurement of GWBF velocity, which is less invasive and provides objective values, is very useful for diagnosing ACPBD prior to the development of malignant tumors in cases with gallbladder wall thickening.
文摘Objective: To observe the sonographic and hemodynamic features of hypoechoic hypertrophic lesions and hypoechoic cancer lesions in the hypertrophic prostate inner glands, in order to raise the accuracy of early diagnosis rate for prostate cancer. Methods: 31 cases of hypoechoic hypertrophic lesions and 18 cases of hypoechoic cancer lesions in the hypertrophic prostate inner glands were observed by transrectal ultrasonography and comparatively analyze the shape, edge and the systolic peak velocity (Vs) , resistance index (RI) and pulsatility index (PI) of the lesions. Results: In contrast with hypertrophic group, the cancer group presented irregular shape and unclear edge, and obviously higher Vs, RI and PI. Conclusion: The sonographic appearance and Vs. RI. PI have important value in distinguishing hypoechoic hypertrophic lesions and hypoechoic cancer lesions in the hypertrophic prostate inner glands.
文摘Objective: To evaluate the value of identifying and diagnosing mammary carcinoma and non-lactation mastitis lump (NLM) by multicolor Doppler ultrasonography. Methods: We compared and analyzed the examination results of 69 cases of mammary carcinoma proved by surgical pathology and 22 cases of NLM before surgery by multicolor Doppler ultra-sonography. Results: The detection rates of mammary carcinoma and NLM focus by ultrasonic examining were 100%. The shape, envelope, foul line, blood stream between sound and image of two diseases were similar. Of the two diseases, the representation with slight calcification in lump, lower echo in low echo, bloodstream distribution and resistance were different. Conclusion: By analyzing the sound and image representation of mammary lump, we find color Doppler ultrasonography has significant value in identifying and diagnosing mammary carcinoma and non-lactation mastitis lump.
文摘OBJECTIVE: To assess the value of color Doppler ultrasonography in monitoring normal orthotopic liver transplantation and postoperative complications. METHODS: Forty-one patients after orthotopic liver transplantation were examined by using color Doppler flow imaging to observe the hepatic blood flow and change of ultrasonography of the hepatic parenchyma and bile duct. The measured indexes included maximum blood flow velocity, time-average blood flow velocity (TAV), resistance index (RI) and diameter of the bile duct. RESULTS: Among 41 patients, 17 (41.5%) suffered from liver transplant rejection. Of the 17 patients, 13 (76.4%) showed decrease of TAV of the portal vein, 15 (88.25%) low-amplitude single-phase serrated wave or negative biphasic wave of the hepatic vein, 9 (52.9%) increased hepatic arterial RI, and 5 (29.4%) slightly dilated bile duct. Sonography showed disappearance of the hepatic artery blood flow around the portal vein in 5 (12.2%) of the 41 patients with hepatic artery thrombosis in the postoperative period. Slight dilatation of the intrahepatic bile duct was found in 3 (7.3%) of the 41 patients in the early postoperational period and it normalized within 2 weeks. Ultrasonography of 20 patients (48.8%) revealed a visible dilatation of the intrahepatic bile duct, which was worsening gradually. The causes of bile duct dilatation included biliary stricture in 2 patients (10%), stone in 15 patients (75%) and others in 3 patients (15%). CONCLUSIONS: Color Doppler ultrasonography is valuable for monitoring normal liver transplantation and postoperative complications.
文摘Graves’ disease, as known today, is an autoimmune, diffuse, chronic disease of thyroid gland, as described by Robert Graves in 1835. It presents genetic predisposition and unknown etiology evidence, which is influenced in its development by several factors, including environment (dietary iodine intake, stress, drugs and infections). The disease is characterized by one or more changes: hyperthyroidism, goiter, ophthalmopathy, skin changes and pretibial myxedema, around 5% less common, and other symptoms 90% to 95%. One of the most relevant clinical practice aspects in Graves’ disease patients management is to distinguish Graves’ disease in initial phase, from other types of destructive thyrotoxicosis, in addition to evaluate therapeutic methods and efficient follow up, as well as predict early recurrence or remission of disease. Scintigraphy with pertechnetate (99 mTc) and TSH levels dosage are considered the choice for this purpose. However, they present some technical difficulties, as they are not widely available and have contraindications. In this scenario, thyroid color-flow doppler ultrasonography (US Doppler) presents a viable alternative, as a widely available, low cost, non-invasive and radiation free method, providing initial diagnosis and patients with Graves’ disease follow up. In adittion, this method is used in differential diagnosis with other causes of thyrotoxicosis in the early stage.
文摘Objective To evaluate color Doppler ultrasonography (CDU) appearances of renal vein thrombosis (RVT) and its diagnostic value.Methods Ten patients with RVT were analyzed retrospectively. Renal structure, distributions of intrarenal flow signals, echogenicity, and flow fullness in main renal veins were observed with CDU. Resistance index (RI) was recorded from the waveforms of segmental or interlobar renal artery.Results Ten kidneys in nine patients were confirmed to have thrombus within the main renal veins, and one patient was confirmed to have thrombus within the small intrarenal veins. The appearances of the main renal vein thrombosis included full of solid echogenicity or strip echogenicity and complete or partial filling defect within the main renal veins, and absent or a few intrarenal venous flow signals in 70% of kidneys involved. The appearances of intrarenal vein thrombosis included obscure renal structure and no venous flow signal within the involved part of the kidneys. Reverse diastolic flow in the intrarenal artery had only a sensitivity of 36% (4/11); in other 7 kidneys without intrarenal arterial reverse diastolic flow, increased RI (mean, 0.84; range, 0.74-0.96) was found.Conclusion CDU is helpful for rapid clinical diagnosis and follow-up of RVT, and therefore can be the first imaging modality of choice for RVT.
文摘One hundred and four cases of breast disease were examined by color Doppler ultrasonography (CDUS). Malignant lesions were rich in blood blow signal and 56% of +++-++++grade while benign lesions had little blood flow signal
文摘Purpose To analyze the sources of errors and discuss the techniques to eliminate pitfalls in detecting deep vein thrombosis (DVT) of the proximal lower extremities with color duplex ultrasonography (CDUS). Methods Sixty-eight cases with initial and repeat venous CDUS of the proximal lower extremities were retrospectively reviewed. The repeat was done within 24 hours after initial CDUS scanning. Comparing repeated images to initial ones, the pitfalls and sources of error in CDUS of the proximal lower extremities were discussed. Results In total 68 repeat studies, there were 62 results as same as initials and 4 cases of false negative DVT and 2 cases of false positive DVT. Conclusion Venous CDUS in detecting DVT is observer dependent. Some pitfalls and errors can be eliminated and corrected with proper scan techniques. CDUS is the most valuable imaging modality for assessing suspected DVT in the proximal lower extremities.
文摘Renal artery stenosis as a complication from radiation therapy is not common, but it is life threatening and needs to be corrected urgently in order to prevent renal failure even losing kidney. The diagnostic criteria of renal artery stenosis in the adults by color duplex ultrasonography have been established, which may play an important role in screening radiation induced renal artery stenosis.
基金Supported by The grant of the Republic of Science of Serbia (M145033,Chief investigatior:Professor Vladimir Obradovic)
文摘AIM: To estimate the characteristics of Color Doppler findings and the results of hepatic radionuclide angiography (HRA) in secondary Hodgkin's hepatic lymphoma. METHODS: The research included patients with a diagnosis of Hodgkin's lymphoma with metastatic focal lesions in the liver and controls. Morphologic characteristics of focal liver lesions and hemodynamic parameters were examined by pulsed and Color Doppler in the portal, hepatic and splenic veins were examined. Hepatic perfusion index (HPI) estimated by HRA was calculated. was observed. Lesions were mostly hypoechoic and mixed, solitary or multiple. Some of the patients presented with dilated splenic veins and hepatofugal blood flow. A pulse wave was registered in the centre and at the margins of lymphoma. The average velocity of the pulse wave was higher at the margins (P 〉 0.05). A continuous venous wave was found only at the margins of lymphoma. There was no linear correlation between lymphoma size and velocity of pulse and continuous wave (r = 390, P 〈 0.01). HPI was significantly lower in patients with lymphomas than in controls (P 〈 0.05), pointing out increased arterial perfusion in comparison to portal perfusion. CONCLUSION: Color Doppler ultrasonography is a sensitive method for the detection of neovascularization in Hodgkin's hepatic lymphoma and estimation of its intensity. Hepatic radionuclide angiography can additionally help in the assesment of vascularisation of liver lesions.
文摘Background Laparoscopic splenectomy (LS) is currently the standard approach for resection of a normal-sized spleen. However, this method becomes technical challenge in cases of splenomegaly due to intraoperative hemorrhage. A complete understanding of the splenic vessel anatomy is important to facilitate the difficult laparoscopic procedure. In this retrospective study, we examined the role of color Doppler flow imaging (CDFI) in splenic vessel anatomy and evaluated its value for LS. Methods Forty-eight patients who underwent splenectomy for various hematologic and autoimmune disorders from May 2004 to December 2007 were enrolled in this study. Twenty-three patients underwent preoperative CDFI examination that included examination of the anatomic type of splenic pedicle, the adjacent relationship between the splenic vessel and pancreas, and spleen size (CDFI group). In the remaining 25 patients, ultrasonic inspections of the splenic vessel were not performed (non-CDFI group). Laparoscopic splenectomies in the CDFI group were performed in accordance with the information provided by the preoperative CDFI in each patient. In the non-CDFI group, LS was performed according to the conventional method. In the CDFI group, the constituent ratios of the above-mentioned parameters by CDFI were compared with those recorded during LS using the chi square test. The effectiveness of the technique on surgery in both groups was compared with an independent sample Student's ttest. Results All laparoscopic splenectomies in both groups were performed successfully. However, 2 cases in the non-CDFI group were converted to LS with the assistance of micro-incision because the branches of the splenic vein were inadvertently torn. Two anatomic types of splenic pedicle and four different adjacent relationships between the splenic vessel and pancreas were detected by CDFI. About 80% of spleens fit the criteria of megalosplenia. There were no statistically significant differences between the constituent ratios of the parameters by CDFI and those by intraoperative telerecording in the CDFI group (χ^2=0.383, 1.072, 0.119, P=0.536, 0.784, 0.730). However, statistically significant differences were observed in the operative time ((158.70±42.51) minutes vs (200.65±47.89) minutes, P=0.003), intraoperative blood loss ((55.87±17.36) ml vs (101.83±62.21) ml, P=0.001), and recovery time of gastrointestinal function ((24.39±8.88) hours vs (30.60±9.45) hours, P=0.024) between the groups. Conclusions The individual operative route and schedule can be successfully determined on the basis of various kinds of reproducible anatomic frameworks of the spleen provided by preoperative CDFI. This technique facilitates the surgical procedure, shortens the operative time, reduces intraoperative blood loss and decreases the risk of LS in splenomegaly cases.