AIM: To investigate the value of two-dimensional (2D) and three-dimensional (3D) double contrast-enhanced ultrasonography (DCUS) imaging for evaluation of gas- tric lesions. METHODS: 2D and 3D DCUS imaging wit...AIM: To investigate the value of two-dimensional (2D) and three-dimensional (3D) double contrast-enhanced ultrasonography (DCUS) imaging for evaluation of gas- tric lesions. METHODS: 2D and 3D DCUS imaging with both oral and intravenous administrations of contrast agents was used to assess gastroscopiclly-confirmed gastric lesions in 46 patients with benign and malignant diseases. Initially, liquid-based ultrasound contrast agent (Xinzhang) was given orally at dose of 500-600 mL for conventional ultrasound examination of the gastric lesions, and then a microbubble-based contrast agent (SonoVue) was injected intravenously at dose of 1.2-2.4 mL in bolus fashion to assess the perfusion pattern of the lesions using contrast imaging modes. The parameters derived from time-intensity curves including the arrival time (AT), time to peak (lq-P), peak intensity (PI) and en- hanced intensity (EI) were measured on the 2D DCUS imaging. 3D DCUS of the lesions was acquired to dem- onstrate the value of this imaging mode. RESULTS: There were 22 cases with benign lesions including chronic gastritis (n= 5), gastric ulcer (n = 9), gastric polyps (n = 3), gastric stromal tumors (n = 5), and 24 cases with malignant lesions including gastric cancer (n = 20), gastric cardia carcinoma (n = 3) and post-operative recurrent gastric cancer (n = 1) in the study, The oral contrast-enhanced ultrasonography (CEUS) imaging of the stomach clearly demonstrated the anatomy of the stomach and morphologic features of gastric lesions, With optimal scanning window and imaging display under oral CEUS, intravenous CEUS clearly showed the perfusion of gastric lesions with various characteristic manifestations. Both 2D and 3D DCUS images clearly demonstrated normal gastric wall as a three-layer structure, from the inside out, hypere- choic mucosa, hypoechoic muscularis and hyperechoic serosa, respectively. There were statistical significant differences of AT (8.68±2.06 vs 10.43 ±2.75, P = 0.017), PI (34.64 ± 6.63 vs 29.58 ± 8.22, P = 0.023) and EI (29.72 ± 6.69 vs 22.66 ± 7.01, P = 0.001) between malignant lesions and normal gastric wall. However, no differences of AT, PI and EI between benign lesions and normal gastric wall tissue were found. 3D DCUS could intuitively display morphological features and vascularities of the lesions with multiplanar and volume views. 3D DCUS imaging provided comprehen- sive information complementary to 2D imaging. The crater or wellhead appearances and feeding vessels as well as distorted nourishing vasculature of gastric carcinoma were better seen with 3D imaging than 2D imaging. CONCLUSION: DCUS imaging can simultaneouslydisplay the anatomic and perfusion features of gastric lesions. 3D DCUS can provide additional information to 2D DCUS for evaluation of gastric lesions.展开更多
BACKGROUND Accurate condition assessment is critical for improving the prognosis of neonatal respiratory distress syndrome(RDS),but current assessment methods for RDS pose a cumulative risk of harm to neonates.Thus,a ...BACKGROUND Accurate condition assessment is critical for improving the prognosis of neonatal respiratory distress syndrome(RDS),but current assessment methods for RDS pose a cumulative risk of harm to neonates.Thus,a less harmful method for assessing the health of neonates with RDS is needed.AIM To analyze the relationships between pulmonary ultrasonography and respiratory distress scores,oxygenation index,and chest X-ray grade of neonatal RDS to identify predictors of neonatal RDS severity.METHODS This retrospective study analyzed the medical information of 73 neonates with RDS admitted to the neonatal intensive care unit of Liupanshui Maternal and Child Care Service Center between April and December 2022.The pulmonary ultrasonography score,respiratory distress score,oxygenation index,and chest Xray grade of each newborn before and after treatment were collected.Spearman correlation analysis was performed to determine the relationships among these values and neonatal RDS severity.RESULTS The pulmonary ultrasonography score,respiratory distress score,oxygenation index,and chest X-ray RDS grade of the neonates were significantly lower after treatment than before treatment(P<0.05).Spearman correlation analysis showed that before and after treatment,the pulmonary ultrasonography score of neonates with RDS was positively correlated with the respiratory distress score,oxygenation index,and chest X-ray grade(ρ=0.429–0.859,P<0.05).Receiver operating characteristic curve analysis indicated that pulmonary ultrasonography screening effectively predicted the severity of neonatal RDS(area under the curve=0.805–1.000,P<0.05).CONCLUSION The pulmonary ultrasonography score was significantly associated with the neonatal RDS score,oxygenation index,and chest X-ray grade.The pulmonary ultrasonography score was an effective predictor of neonatal RDS severity.展开更多
This research aimed to examine the diagnostic accuracy and clinical significance of endoscopic ultrasonography(EUS)in the context of small rectal neuroendocrine neoplasms(NENs).A total of 108 patients with rectal sube...This research aimed to examine the diagnostic accuracy and clinical significance of endoscopic ultrasonography(EUS)in the context of small rectal neuroendocrine neoplasms(NENs).A total of 108 patients with rectal subepithelial lesions(SELs)with a diameter of<20 mm were included in the analysis.The diagnosis and depth assessment of EUS was compared to the histology findings.The prevalence of NENs in rectal SELs was 78.7%(85/108).The sensitivity of EUS in detecting rectal NENs was 98.9%(84/85),while the specificity was 52.2%(12/23).Overall,the diagnostic accuracy of EUS in identifying rectal NENs was 88.9%(96/108).The overall accuracy rate for EUS in assessing the depth of invasion in rectal NENs was 92.9%(78/84).Therefore,EUS demonstrates reasonable diagnostic accuracy in detecting small rectal NENs,with good sensitivity but inferior specificity.EUS may also assist physicians in assessing the depth of invasion in small rectal NENs before endoscopic excision.展开更多
BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and ...BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and third for mortality.Knowledge of the invasive depth of the tumor is vital to treatment decisions.AIM To evaluate the diagnostic performance of double contrast-enhanced ultrasonography(DCEUS)for preoperative T staging in patients with GC by comparing with multi-detector computed tomography(MDCT).METHODS This single prospective study enrolled patients with GC confirmed by preoperative gastroscopy from July 2021 to March 2023.Patients underwent DCEUS,including ultrasonography(US)and intravenous contrast-enhanced ultrasonography(CEUS),and MDCT examinations for the assessment of preoperative T staging.Features of GC were identified on DCEUS and criteria developed to evaluate T staging according to the 8th edition of AJCC cancer staging manual.The diagnostic performance of DCEUS was evaluated by comparing it with that of MDCT and surgical-pathological findings were considered as the gold standard.RESULTS A total of 229 patients with GC(80 T1,33 T2,59 T3 and 57 T4)were included.Overall accuracies were 86.9%for DCEUS and 61.1%for MDCT(P<0.001).DCEUS was superior to MDCT for T1(92.5%vs 70.0%,P<0.001),T2(72.7%vs 51.5%,P=0.041),T3(86.4%vs 45.8%,P<0.001)and T4(87.7%vs 70.2%,P=0.022)staging of GC.CONCLUSION DCEUS improved the diagnostic accuracy of preoperative T staging in patients with GC compared with MDCT,and constitutes a promising imaging modality for preoperative evaluation of GC to aid individualized treatment decision-making.展开更多
Intraoperative ultrasonography(IOUS)in hepatobiliary surgery is well known as an essential tool for radical and safe hepatectomies,allowing to perform parenchymal sparing surgery and,as consequence,to expand the surgi...Intraoperative ultrasonography(IOUS)in hepatobiliary surgery is well known as an essential tool for radical and safe hepatectomies,allowing to perform parenchymal sparing surgery and,as consequence,to expand the surgical indications for patients otherwise considered unresectable.Nevertheless,since many years,despite its effectiveness in the study of vascular anatomy of the liver,the gold standard for the assessment of biliary anatomy during surgery is intraoperative cholangiography(IOC),which is used for the validation of preoperative imaging as well as for guiding reconstruction in case of bile duct injury or resection.展开更多
Background: Certain ovarian cancers that were previously common in postmenopausal women are now increasingly observed in women of reproductive age. The research on using β-HCG as a diagnostic biomarker for ovarian ca...Background: Certain ovarian cancers that were previously common in postmenopausal women are now increasingly observed in women of reproductive age. The research on using β-HCG as a diagnostic biomarker for ovarian cancer in women of reproductive age is ongoing. Aim: This study assessed the level of serum β-HCG in non-pregnant women of reproductive age and determined its potential association with suspicious ovarian ultrasonography results. Methods: The study was conducted in Port Harcourt, Nigeria. This study adopted a cross-sectional design on a quota sample of 224 case notes of women aged 18 - 40 years obtained from eight diagnostic centres. A data extraction form was used for data collection. Data analysis employed descriptive statistics, Chi-square, Fisher’s exact test, and Odds Ratio at 95% confidence and 5% significance levels. Results: About 5.8% of the participants exhibited detectable levels of serum β-HCG above 5 IU/L (World Health Organization reference) at a mean concentration of 5.87 (±1.75) IU/L. About 4.0% of the participants had suspicious ovarian lesions identified through ultrasonography. Participants with elevated serum β-HCG levels above the WHO reference were 59 times more likely to have suspicious ovarian lesions (Odds ratio: 59.4, 95%CI: 12.3 - 287.8, p β-HCG level and age (p = 0.041) as well as parity (p Conclusion: Serum β-HCG levels above the WHO reference in non-pregnant women were associated with suspicious ovarian lesions. More rigorous primary research, systematic reviews, and meta-analyses are needed to confirm the findings of this study.展开更多
BACKGROUND It is possible that this condition will lead to urosepsis and progressive deterioration of renal function in the absence of surgical intervention.Several recent clinical studies have shown that multi-tract ...BACKGROUND It is possible that this condition will lead to urosepsis and progressive deterioration of renal function in the absence of surgical intervention.Several recent clinical studies have shown that multi-tract percutaneous nephrolithotomy(MPCNL)has a similar stone free rate(SFR)as standard percutaneous nephrolithotomy(S-PCNL).As a result,M-PCNL was also recommended as a treatment option for staghorn calculi.AIM To examine the perioperative and long-term results of ultrasonography-guided single-and M-PCNL.METHODS This was a retrospective cohort study.Between March 2021 and January 2022,the urology department of our hospital selected patients for the treatment of staghorn calculi using percutaneous nephrolithotomy.The primary outcomes were com plication rate and SFR,and the characteristics of patients,operative parameters,laboratory measurements were also collected.RESULTS In total,345 patients were enrolled in the study(186 in the S-PCNL group and 159 in the M-PCNL group).The SFR in the M-PCNL group was significantly higher than that in the S-PCNL group(P=0.033).Moreover,the incidence rates of hydrothorax(P=0.03)and postoperative infection(P=0.012)were higher in the M-PCNL group than in the S-PCNL group.Logistic regression analysis demonstrated that post-operative white blood cell count(OR=2.57,95%CI:1.90-3.47,P<0.001)and stone size(OR=1.59,95%CI:1.27-2.00,P<0.001)were associated with a higher overall complication rate in the S-PCNL group.Body mass index(OR=1.22,95%CI:1.06-1.40,P=0.004)and stone size(OR=1.70,95%CI:1.35-2.15,P<0.001)were associated with increased overall complications in the M-PCNL group.CONCLUSION Multiple access tracts can facilitate higher SFR while slightly increasing the incidence of acceptable complications.展开更多
BACKGROUND Pancreatic ductal adenocarcinoma(PDAC)is a highly malignant and aggressive tumor,and high Ki-67 expression indicates poor histological differentiation and prognosis.Therefore,one of the challenges in diagno...BACKGROUND Pancreatic ductal adenocarcinoma(PDAC)is a highly malignant and aggressive tumor,and high Ki-67 expression indicates poor histological differentiation and prognosis.Therefore,one of the challenges in diagnosing preoperatively patients with PDAC is predicting the degree of malignancy.Dynamic contrast-enhanced ultrasonography(DCE-US)plays a crucial role in abdominal tumor diagnosis,and can adequately show the microvascular composition within the tumors.However,the relationship between DCE-US and the Ki-67 labelling index remains unclear at the present time.AIM To predict the correlation between Ki-67 expression and the parameters of DCEUS.METHODS Patients with PDAC who underwent DCE-US were retrospectively analyzed.Patients who had received any treatment(radiotherapy or chemotherapy)prior to DCE-US;had incomplete clinical,imaging,or pathologic information;and had poor-quality image analysis were excluded.Correlations between Ki-67 expression and the parameters of DCE-US in patients with PDAC were assessed using Spearman’s rank correlation analysis.The diagnostic performances of these parameters in high Ki-67 expression group were evaluated according to receiver operating characteristic curve.RESULTS Based on the Ki-67 labelling index,30 patients were divided into two groups,i.e.,the high expression group and the low expression group.Among the relative quantitative parameters between the two groups,relative half-decrease time(rHDT),relative peak enhancement,relative wash-in perfusion index and relative wash-in rate were significantly different between two groups(P=0.018,P=0.025,P=0.028,P=0.035,respectively).The DCE-US parameter rHDT was moderately correlated with Ki-67 expression,and rHDT≥1.07 was more helpful in accurately diagnosing high Ki-67 expression,exhibiting a sensitivity and specificity of 53.8%and 94.1%,respectively.CONCLUSION One parameter of DCE-US,rHDT,correlates with high Ki-67 expression.It demonstrates that parameters obtained noninvasively by DCE-US could better predict Ki-67 expression in PDAC preoperatively.展开更多
BACKGROUND The incidence of gastric cancer remains high,and it is the sixth most common cancer and the fourth leading cause of cancer deaths worldwide.Oral contrastenhanced ultrasonography is a simple,non-invasive,and...BACKGROUND The incidence of gastric cancer remains high,and it is the sixth most common cancer and the fourth leading cause of cancer deaths worldwide.Oral contrastenhanced ultrasonography is a simple,non-invasive,and painless method for the diagnosis of gastric tumors.AIM To explore the diagnostic value of oral contrast-enhanced ultrasonography for the detection of gastric tumors.METHODS The screening results based on oral contrast-enhanced ultrasonography and electronic gastroscopy were compared with those of the postoperative pathological examination.RESULTS Among 42 patients with gastric tumors enrolled in the study,the diagnostic accordance rate was 95.2%for oral contrast-enhanced ultrasonography(n=40)and 90.5%for electronic gastroscopy(n=38)compared with postoperative pathological examination.The Kappa value of consistency test with pathological findings was 0.812 for oral contrast-enhanced ultrasonography and 0.718 for electronic gastroscopy,and there was no significant difference between them(P=0.397).For the TNM staging of gastric tumors,the accuracy rate of oral contrast enhanced ultrasonography was 81.9%for the overall T staging and 50%,77.8%,100%,and 100%for T1,T2,T3,and T4 staging,respectively.The sensitivity and specificity were both 100%for stages T3 and T4.The diagnostic accuracy rate of oral contrast-enhanced ultrasonography was 93.8%,80%,100%,and 100%for stages N0,N1-N3,M0,and M1,respectively.CONCLUSION The accordance rate of qualitative diagnosis by oral contrast-enhanced ultrasonography is comparable to that of gastroscopy,and it could be used as the preferred method for the early screening of gastric tumors.展开更多
BACKGROUND Superior mesenteric artery(SMA)syndrome is a rare cause of duodenal obstruction by extrinsic compression between the SMA and the aorta(SMA-Ao).Although the left lateral recumbent position is considered effe...BACKGROUND Superior mesenteric artery(SMA)syndrome is a rare cause of duodenal obstruction by extrinsic compression between the SMA and the aorta(SMA-Ao).Although the left lateral recumbent position is considered effective in the treatment of SMA syndrome,individual variations in the optimal patient position have been noted.In this report,we present two elderly cases of SMA syndrome that exhibited rapid recovery due to ultrasonographic dynamic evaluation of the optimal position for each patient.CASE SUMMARY Case 1:A 90-year-old man with nausea and vomiting.Following diagnosis of SMA syndrome by computed tomography(CT),ultrasonography(US)revealed the SMA-Ao distance in the supine position(4 mm),which slightly improved in the lateral position(5.7–7.0 mm)without the passage of duodenal contents.However,in the sitting position,the SMA-Ao distance was increased to 15 mm accompanied by improved content passage.Additionally,US indicated enhanced passage upon abdominal massage on the right side.By day 2,the patient could eat comfortably with the optimal position and massage.Case 2:An 87-year-old woman with vomiting.After the diagnosis of SMA syndrome and aspiration pneumonia by CT,dynamic US confirmed the optimal position(SMA-Ao distance was improved to 7 mm in forward-bent position,whereas it remained at 5 mm in the supine position).By day 7 when her pneumonia recovered,she could eat with the optimal position.CONCLUSION The optimal position for SMA syndrome varies among individuals.Dynamic US appears to be a valuable tool in improving patient outcomes.展开更多
Point of care ultrasonography(POCUS)has evolved to become the fifth pillar of the conventional physical examination,and use of POCUS protocols have significantly decreased procedure complications and time to diagnose....Point of care ultrasonography(POCUS)has evolved to become the fifth pillar of the conventional physical examination,and use of POCUS protocols have significantly decreased procedure complications and time to diagnose.However,lack of experience in POCUS by preceptors in medical schools and nephrology residency programs are significant barriers to implement a broader use.In rural and low-income areas POCUS may have a transformative effect on health care management.展开更多
Point-of-care ultrasonography(POCUS),particularly venous excess ultrasound(VExUS)is emerging as a valuable bedside tool to gain real-time hemodynamic insights.This modality,derived from hepatic vein,portal vein,and in...Point-of-care ultrasonography(POCUS),particularly venous excess ultrasound(VExUS)is emerging as a valuable bedside tool to gain real-time hemodynamic insights.This modality,derived from hepatic vein,portal vein,and intrarenal vessel Doppler patterns,offers a scoring system for dynamic venous congestion assessment.Such an assessment can be crucial in effective management of patients with heart failure exacerbation.It facilitates diagnosis,quantification of congestion,prognostication,and monitoring the efficacy of decongestive therapy.As such,it can effectively help to manage cardiorenal syndromes in various clinical settings.Extended or eVExUS explores additional veins,potentially broadening its applications.While VExUS demonstrates promising outcomes,challenges persist,particularly in cases involving renal and liver parenchymal disease,arrhythmias,and situations of pressure and volume overload overlap.Proficiency in utilizing spectral Doppler is pivotal for clinicians to effectively employ this tool.Hence,the integration of POCUS,especially advanced applications like VExUS,into routine clinical practice necessitates enhanced training across medical specialties.展开更多
This article delves into the intricate challenges of acute kidney injury(AKI)in cirrhosis,a condition fraught with high morbidity and mortality.The complexities arise from distinguishing between various causes of AKI,...This article delves into the intricate challenges of acute kidney injury(AKI)in cirrhosis,a condition fraught with high morbidity and mortality.The complexities arise from distinguishing between various causes of AKI,particularly hemodynamic AKI,in cirrhotic patients,who experience hemodynamic changes due to portal hypertension.The term"hepatocardiorenal syndrome"is introduced to encapsulate the intricate interplay among the liver,heart,and kidneys.The narrative emphasizes the often-overlooked aspect of cardiac function in AKI assessments in cirrhosis,unveiling the prevalence of cirrhotic cardiomyopathy marked by impaired diastolic function.The conventional empiric approach involving volume expansion and vasopressors for hepatorenal syndrome is critically analyzed,highlighting potential risks and variable patient responses.We advocate for a nuanced algorithm for AKI evaluation in cirrhosis,prominently featuring point-of-care ultrasonography(POCUS).POCUS applications encompass assessing fluid tolerance,detecting venous congestion,and evaluating cardiac function.展开更多
Esophageal tuberculosis(ET)is a relatively rare clinical condition,characterized by often atypical clinical features.The lack of specificity in diagnostic methods,such as esophagogastroduodenoscopy and various imaging...Esophageal tuberculosis(ET)is a relatively rare clinical condition,characterized by often atypical clinical features.The lack of specificity in diagnostic methods,such as esophagogastroduodenoscopy and various imaging techniques,frequently leads to misdiagnosis and inappropriate treatments.Compared to esophagogastroduodenoscopy,endoscopic ultrasonography(EUS)offers a more comprehensive examination of esophageal tuberculosis lesions,including the extent of wall layer involvement and the internal structure characteristics of the lesions.Furthermore,when necessary,endoscopic ultrasonography-guided fine-needle aspiration can be employed to acquire deeper pathological tissue,significantly aiding diagnosis.When combined with the patient’s clinical presentation,endoscopic findings,and pathological features,EUS plays a crucial role in the definitive diagnosis of ET and in the differential diagnosis process.This article meticulously reviews both national and international literature to summarize the relevant features of ET,with a focus on its appearance under EUS,and to highlight the clinical value of EUS in enhancing the diagnosis of ET and in distinguishing it from other conditions.The aim is to offer guidance for the accurate diagnosis of ET.展开更多
BACKGROUND Few systematic comparative studies of the different methods of physical elastography of the spleen are currently available.AIM To compare point shear wave and two-dimensional elastography of the spleen cons...BACKGROUND Few systematic comparative studies of the different methods of physical elastography of the spleen are currently available.AIM To compare point shear wave and two-dimensional elastography of the spleen considering the anatomical location(upper,hilar,and lower pole).METHODS As part of a prospective clinical study,healthy volunteers were examined for splenic elasticity using four different ultrasound devices between May 2015 and April 2017.The devices used for point shear wave elastography were from Siemens(S 3000)and Philips(Epiq 7),and those used for two-dimensional shear wave elastography were from GE(Logiq E9)and Toshiba(Aplio 500).In addition,two different software versions(5.0 and 6.0)were evaluated for the Toshiba ultrasound device(Aplio 500).The study consisted of three arms:A,B,and C.RESULTS In study arm A,200 subjects were evaluated(78 males and 122 females,mean age 27.9±8.1 years).In study arm B,113 subjects were evaluated(38 men and 75 women,mean age 26.0±6.3 years).In study arm C,44 subjects were enrolled.A significant correlation of the shear wave velocities at the upper third of the spleen(r=0.33088,P<0.0001)was demonstrated only for the Philips Epiq 7 device compared to the Siemens Acuson S 3000.In comparisons of the other ultrasound devices(GE,Siemens,Toshiba),no comparable results could be obtained for any anatomical position of the spleen.The influencing factors age,gender,and body mass index did not show a clear correlation with the measured shear wave velocities.CONCLUSION The absolute values of the shear wave elastography measurements of the spleen and the two different elastography methods are not comparable between different manufacturers or models.展开更多
As a kind of subculture, The two-dimensional culture came of age during the 1970s in Japan and spread to China in the 1980s. In China, the culture has become an important economic force and social capital get more and...As a kind of subculture, The two-dimensional culture came of age during the 1970s in Japan and spread to China in the 1980s. In China, the culture has become an important economic force and social capital get more and more attention to it as well. This paper mainly discusses the origin and development of the two-dimensional clothing, and summed up the inherent characteristics and the internal developing law of it, furthermore, on the stage of current situation of two-dimensional economy this paper will conclude the development trend of next days.展开更多
Endoscopic ultrasonography(EUS)represents the combination of endoscopy and intraluminal ultrasonography.This allows use of a high-frequency transducer(5-20 MHz)that,due to the short distance to the target lesion,provi...Endoscopic ultrasonography(EUS)represents the combination of endoscopy and intraluminal ultrasonography.This allows use of a high-frequency transducer(5-20 MHz)that,due to the short distance to the target lesion,provides ultrasonographic images of higher resolution than those obtained from other imaging modalities,including multiple-detector-row-computed tomography,magnetic resonance imaging,and positron emission tomography.EUS is now a widely accepted modality for diagnosing pancreatic diseases.However,the most important limitation of EUS has been the lack of specificity in differentiating between benign and malignant changes.In 1992,EUS-guided fine needle aspiration(FNA)of lesions in the pancreas head was introduced into clinical practice,using a curved linear-array echoendoscope.Since then,EUS has evolved from EUS imaging to EUSFNA and wider applications.Interventional EUS for pancreatic cancer includes EUS-FNA,EUS-guided fine needle injection,EUS-guided biliary drainage and anastomosis,EUS-guided celiac neurolysis,radiofrequency ablation,brachytherapy,and delivery of a growing number of anti-tumor agents.This review focuses on interventional EUS,including EUS-FNA and therapeutic EUS for pancreatic cancer.展开更多
Some theorems of compactly supported non-tensor product form two-dimension Daubechies wavelet were analysed carefully. Compactly supported non-tensor product form two-dimension wavelet was constructed, then non-tensor...Some theorems of compactly supported non-tensor product form two-dimension Daubechies wavelet were analysed carefully. Compactly supported non-tensor product form two-dimension wavelet was constructed, then non-tensor product form two dimension wavelet finite element was used to solve the deflection problem of elastic thin plate. The error order was researched. A numerical example was given at last.展开更多
The adaptive mesh refinement (AMR) method is applied in the 2-D Euler multi-component elasticplastic hydrodynamics code (MEPH2Y). It is applied on detonation. Firstly, the AMR method is described, including a cons...The adaptive mesh refinement (AMR) method is applied in the 2-D Euler multi-component elasticplastic hydrodynamics code (MEPH2Y). It is applied on detonation. Firstly, the AMR method is described, including a conservative spatial interpolation, the time integration methodology with the adapitve time increment and an adaptive computational region method. The advantage of AMR technique is exhibited by numerical examples, including the 1-D C-J detonation and the 2-D implosion ignited from a single point. Results show that AMR can promote the computational efficiency, keeping the accuracy in interesting regions.展开更多
基金Supported by A key medical project in Nanjing Military District of the Chinese People’s Liberation Army,No. 09Z039
文摘AIM: To investigate the value of two-dimensional (2D) and three-dimensional (3D) double contrast-enhanced ultrasonography (DCUS) imaging for evaluation of gas- tric lesions. METHODS: 2D and 3D DCUS imaging with both oral and intravenous administrations of contrast agents was used to assess gastroscopiclly-confirmed gastric lesions in 46 patients with benign and malignant diseases. Initially, liquid-based ultrasound contrast agent (Xinzhang) was given orally at dose of 500-600 mL for conventional ultrasound examination of the gastric lesions, and then a microbubble-based contrast agent (SonoVue) was injected intravenously at dose of 1.2-2.4 mL in bolus fashion to assess the perfusion pattern of the lesions using contrast imaging modes. The parameters derived from time-intensity curves including the arrival time (AT), time to peak (lq-P), peak intensity (PI) and en- hanced intensity (EI) were measured on the 2D DCUS imaging. 3D DCUS of the lesions was acquired to dem- onstrate the value of this imaging mode. RESULTS: There were 22 cases with benign lesions including chronic gastritis (n= 5), gastric ulcer (n = 9), gastric polyps (n = 3), gastric stromal tumors (n = 5), and 24 cases with malignant lesions including gastric cancer (n = 20), gastric cardia carcinoma (n = 3) and post-operative recurrent gastric cancer (n = 1) in the study, The oral contrast-enhanced ultrasonography (CEUS) imaging of the stomach clearly demonstrated the anatomy of the stomach and morphologic features of gastric lesions, With optimal scanning window and imaging display under oral CEUS, intravenous CEUS clearly showed the perfusion of gastric lesions with various characteristic manifestations. Both 2D and 3D DCUS images clearly demonstrated normal gastric wall as a three-layer structure, from the inside out, hypere- choic mucosa, hypoechoic muscularis and hyperechoic serosa, respectively. There were statistical significant differences of AT (8.68±2.06 vs 10.43 ±2.75, P = 0.017), PI (34.64 ± 6.63 vs 29.58 ± 8.22, P = 0.023) and EI (29.72 ± 6.69 vs 22.66 ± 7.01, P = 0.001) between malignant lesions and normal gastric wall. However, no differences of AT, PI and EI between benign lesions and normal gastric wall tissue were found. 3D DCUS could intuitively display morphological features and vascularities of the lesions with multiplanar and volume views. 3D DCUS imaging provided comprehen- sive information complementary to 2D imaging. The crater or wellhead appearances and feeding vessels as well as distorted nourishing vasculature of gastric carcinoma were better seen with 3D imaging than 2D imaging. CONCLUSION: DCUS imaging can simultaneouslydisplay the anatomic and perfusion features of gastric lesions. 3D DCUS can provide additional information to 2D DCUS for evaluation of gastric lesions.
基金Guizhou Provincial Science and Technology Department,Technology Achievement Application and Industrialization Plan,Applied Fundamental Research,No.Qianke Synthetic Fruit[2022]004.
文摘BACKGROUND Accurate condition assessment is critical for improving the prognosis of neonatal respiratory distress syndrome(RDS),but current assessment methods for RDS pose a cumulative risk of harm to neonates.Thus,a less harmful method for assessing the health of neonates with RDS is needed.AIM To analyze the relationships between pulmonary ultrasonography and respiratory distress scores,oxygenation index,and chest X-ray grade of neonatal RDS to identify predictors of neonatal RDS severity.METHODS This retrospective study analyzed the medical information of 73 neonates with RDS admitted to the neonatal intensive care unit of Liupanshui Maternal and Child Care Service Center between April and December 2022.The pulmonary ultrasonography score,respiratory distress score,oxygenation index,and chest Xray grade of each newborn before and after treatment were collected.Spearman correlation analysis was performed to determine the relationships among these values and neonatal RDS severity.RESULTS The pulmonary ultrasonography score,respiratory distress score,oxygenation index,and chest X-ray RDS grade of the neonates were significantly lower after treatment than before treatment(P<0.05).Spearman correlation analysis showed that before and after treatment,the pulmonary ultrasonography score of neonates with RDS was positively correlated with the respiratory distress score,oxygenation index,and chest X-ray grade(ρ=0.429–0.859,P<0.05).Receiver operating characteristic curve analysis indicated that pulmonary ultrasonography screening effectively predicted the severity of neonatal RDS(area under the curve=0.805–1.000,P<0.05).CONCLUSION The pulmonary ultrasonography score was significantly associated with the neonatal RDS score,oxygenation index,and chest X-ray grade.The pulmonary ultrasonography score was an effective predictor of neonatal RDS severity.
基金Supported by Basic and Applied Basic Research Foundation of Guangzhou,No.202201011331National Natural Science Foundation of China,No.82373118Natural Science Foundation of Guangdong Province,No.2023A1515010828.
文摘This research aimed to examine the diagnostic accuracy and clinical significance of endoscopic ultrasonography(EUS)in the context of small rectal neuroendocrine neoplasms(NENs).A total of 108 patients with rectal subepithelial lesions(SELs)with a diameter of<20 mm were included in the analysis.The diagnosis and depth assessment of EUS was compared to the histology findings.The prevalence of NENs in rectal SELs was 78.7%(85/108).The sensitivity of EUS in detecting rectal NENs was 98.9%(84/85),while the specificity was 52.2%(12/23).Overall,the diagnostic accuracy of EUS in identifying rectal NENs was 88.9%(96/108).The overall accuracy rate for EUS in assessing the depth of invasion in rectal NENs was 92.9%(78/84).Therefore,EUS demonstrates reasonable diagnostic accuracy in detecting small rectal NENs,with good sensitivity but inferior specificity.EUS may also assist physicians in assessing the depth of invasion in small rectal NENs before endoscopic excision.
基金This study was reviewed and approved by the Ethics Committee of Sun Yat-sen University Cancer Center(Approval No.B2023-219-03).
文摘BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and third for mortality.Knowledge of the invasive depth of the tumor is vital to treatment decisions.AIM To evaluate the diagnostic performance of double contrast-enhanced ultrasonography(DCEUS)for preoperative T staging in patients with GC by comparing with multi-detector computed tomography(MDCT).METHODS This single prospective study enrolled patients with GC confirmed by preoperative gastroscopy from July 2021 to March 2023.Patients underwent DCEUS,including ultrasonography(US)and intravenous contrast-enhanced ultrasonography(CEUS),and MDCT examinations for the assessment of preoperative T staging.Features of GC were identified on DCEUS and criteria developed to evaluate T staging according to the 8th edition of AJCC cancer staging manual.The diagnostic performance of DCEUS was evaluated by comparing it with that of MDCT and surgical-pathological findings were considered as the gold standard.RESULTS A total of 229 patients with GC(80 T1,33 T2,59 T3 and 57 T4)were included.Overall accuracies were 86.9%for DCEUS and 61.1%for MDCT(P<0.001).DCEUS was superior to MDCT for T1(92.5%vs 70.0%,P<0.001),T2(72.7%vs 51.5%,P=0.041),T3(86.4%vs 45.8%,P<0.001)and T4(87.7%vs 70.2%,P=0.022)staging of GC.CONCLUSION DCEUS improved the diagnostic accuracy of preoperative T staging in patients with GC compared with MDCT,and constitutes a promising imaging modality for preoperative evaluation of GC to aid individualized treatment decision-making.
文摘Intraoperative ultrasonography(IOUS)in hepatobiliary surgery is well known as an essential tool for radical and safe hepatectomies,allowing to perform parenchymal sparing surgery and,as consequence,to expand the surgical indications for patients otherwise considered unresectable.Nevertheless,since many years,despite its effectiveness in the study of vascular anatomy of the liver,the gold standard for the assessment of biliary anatomy during surgery is intraoperative cholangiography(IOC),which is used for the validation of preoperative imaging as well as for guiding reconstruction in case of bile duct injury or resection.
文摘Background: Certain ovarian cancers that were previously common in postmenopausal women are now increasingly observed in women of reproductive age. The research on using β-HCG as a diagnostic biomarker for ovarian cancer in women of reproductive age is ongoing. Aim: This study assessed the level of serum β-HCG in non-pregnant women of reproductive age and determined its potential association with suspicious ovarian ultrasonography results. Methods: The study was conducted in Port Harcourt, Nigeria. This study adopted a cross-sectional design on a quota sample of 224 case notes of women aged 18 - 40 years obtained from eight diagnostic centres. A data extraction form was used for data collection. Data analysis employed descriptive statistics, Chi-square, Fisher’s exact test, and Odds Ratio at 95% confidence and 5% significance levels. Results: About 5.8% of the participants exhibited detectable levels of serum β-HCG above 5 IU/L (World Health Organization reference) at a mean concentration of 5.87 (±1.75) IU/L. About 4.0% of the participants had suspicious ovarian lesions identified through ultrasonography. Participants with elevated serum β-HCG levels above the WHO reference were 59 times more likely to have suspicious ovarian lesions (Odds ratio: 59.4, 95%CI: 12.3 - 287.8, p β-HCG level and age (p = 0.041) as well as parity (p Conclusion: Serum β-HCG levels above the WHO reference in non-pregnant women were associated with suspicious ovarian lesions. More rigorous primary research, systematic reviews, and meta-analyses are needed to confirm the findings of this study.
文摘BACKGROUND It is possible that this condition will lead to urosepsis and progressive deterioration of renal function in the absence of surgical intervention.Several recent clinical studies have shown that multi-tract percutaneous nephrolithotomy(MPCNL)has a similar stone free rate(SFR)as standard percutaneous nephrolithotomy(S-PCNL).As a result,M-PCNL was also recommended as a treatment option for staghorn calculi.AIM To examine the perioperative and long-term results of ultrasonography-guided single-and M-PCNL.METHODS This was a retrospective cohort study.Between March 2021 and January 2022,the urology department of our hospital selected patients for the treatment of staghorn calculi using percutaneous nephrolithotomy.The primary outcomes were com plication rate and SFR,and the characteristics of patients,operative parameters,laboratory measurements were also collected.RESULTS In total,345 patients were enrolled in the study(186 in the S-PCNL group and 159 in the M-PCNL group).The SFR in the M-PCNL group was significantly higher than that in the S-PCNL group(P=0.033).Moreover,the incidence rates of hydrothorax(P=0.03)and postoperative infection(P=0.012)were higher in the M-PCNL group than in the S-PCNL group.Logistic regression analysis demonstrated that post-operative white blood cell count(OR=2.57,95%CI:1.90-3.47,P<0.001)and stone size(OR=1.59,95%CI:1.27-2.00,P<0.001)were associated with a higher overall complication rate in the S-PCNL group.Body mass index(OR=1.22,95%CI:1.06-1.40,P=0.004)and stone size(OR=1.70,95%CI:1.35-2.15,P<0.001)were associated with increased overall complications in the M-PCNL group.CONCLUSION Multiple access tracts can facilitate higher SFR while slightly increasing the incidence of acceptable complications.
文摘BACKGROUND Pancreatic ductal adenocarcinoma(PDAC)is a highly malignant and aggressive tumor,and high Ki-67 expression indicates poor histological differentiation and prognosis.Therefore,one of the challenges in diagnosing preoperatively patients with PDAC is predicting the degree of malignancy.Dynamic contrast-enhanced ultrasonography(DCE-US)plays a crucial role in abdominal tumor diagnosis,and can adequately show the microvascular composition within the tumors.However,the relationship between DCE-US and the Ki-67 labelling index remains unclear at the present time.AIM To predict the correlation between Ki-67 expression and the parameters of DCEUS.METHODS Patients with PDAC who underwent DCE-US were retrospectively analyzed.Patients who had received any treatment(radiotherapy or chemotherapy)prior to DCE-US;had incomplete clinical,imaging,or pathologic information;and had poor-quality image analysis were excluded.Correlations between Ki-67 expression and the parameters of DCE-US in patients with PDAC were assessed using Spearman’s rank correlation analysis.The diagnostic performances of these parameters in high Ki-67 expression group were evaluated according to receiver operating characteristic curve.RESULTS Based on the Ki-67 labelling index,30 patients were divided into two groups,i.e.,the high expression group and the low expression group.Among the relative quantitative parameters between the two groups,relative half-decrease time(rHDT),relative peak enhancement,relative wash-in perfusion index and relative wash-in rate were significantly different between two groups(P=0.018,P=0.025,P=0.028,P=0.035,respectively).The DCE-US parameter rHDT was moderately correlated with Ki-67 expression,and rHDT≥1.07 was more helpful in accurately diagnosing high Ki-67 expression,exhibiting a sensitivity and specificity of 53.8%and 94.1%,respectively.CONCLUSION One parameter of DCE-US,rHDT,correlates with high Ki-67 expression.It demonstrates that parameters obtained noninvasively by DCE-US could better predict Ki-67 expression in PDAC preoperatively.
文摘BACKGROUND The incidence of gastric cancer remains high,and it is the sixth most common cancer and the fourth leading cause of cancer deaths worldwide.Oral contrastenhanced ultrasonography is a simple,non-invasive,and painless method for the diagnosis of gastric tumors.AIM To explore the diagnostic value of oral contrast-enhanced ultrasonography for the detection of gastric tumors.METHODS The screening results based on oral contrast-enhanced ultrasonography and electronic gastroscopy were compared with those of the postoperative pathological examination.RESULTS Among 42 patients with gastric tumors enrolled in the study,the diagnostic accordance rate was 95.2%for oral contrast-enhanced ultrasonography(n=40)and 90.5%for electronic gastroscopy(n=38)compared with postoperative pathological examination.The Kappa value of consistency test with pathological findings was 0.812 for oral contrast-enhanced ultrasonography and 0.718 for electronic gastroscopy,and there was no significant difference between them(P=0.397).For the TNM staging of gastric tumors,the accuracy rate of oral contrast enhanced ultrasonography was 81.9%for the overall T staging and 50%,77.8%,100%,and 100%for T1,T2,T3,and T4 staging,respectively.The sensitivity and specificity were both 100%for stages T3 and T4.The diagnostic accuracy rate of oral contrast-enhanced ultrasonography was 93.8%,80%,100%,and 100%for stages N0,N1-N3,M0,and M1,respectively.CONCLUSION The accordance rate of qualitative diagnosis by oral contrast-enhanced ultrasonography is comparable to that of gastroscopy,and it could be used as the preferred method for the early screening of gastric tumors.
文摘BACKGROUND Superior mesenteric artery(SMA)syndrome is a rare cause of duodenal obstruction by extrinsic compression between the SMA and the aorta(SMA-Ao).Although the left lateral recumbent position is considered effective in the treatment of SMA syndrome,individual variations in the optimal patient position have been noted.In this report,we present two elderly cases of SMA syndrome that exhibited rapid recovery due to ultrasonographic dynamic evaluation of the optimal position for each patient.CASE SUMMARY Case 1:A 90-year-old man with nausea and vomiting.Following diagnosis of SMA syndrome by computed tomography(CT),ultrasonography(US)revealed the SMA-Ao distance in the supine position(4 mm),which slightly improved in the lateral position(5.7–7.0 mm)without the passage of duodenal contents.However,in the sitting position,the SMA-Ao distance was increased to 15 mm accompanied by improved content passage.Additionally,US indicated enhanced passage upon abdominal massage on the right side.By day 2,the patient could eat comfortably with the optimal position and massage.Case 2:An 87-year-old woman with vomiting.After the diagnosis of SMA syndrome and aspiration pneumonia by CT,dynamic US confirmed the optimal position(SMA-Ao distance was improved to 7 mm in forward-bent position,whereas it remained at 5 mm in the supine position).By day 7 when her pneumonia recovered,she could eat with the optimal position.CONCLUSION The optimal position for SMA syndrome varies among individuals.Dynamic US appears to be a valuable tool in improving patient outcomes.
文摘Point of care ultrasonography(POCUS)has evolved to become the fifth pillar of the conventional physical examination,and use of POCUS protocols have significantly decreased procedure complications and time to diagnose.However,lack of experience in POCUS by preceptors in medical schools and nephrology residency programs are significant barriers to implement a broader use.In rural and low-income areas POCUS may have a transformative effect on health care management.
文摘Point-of-care ultrasonography(POCUS),particularly venous excess ultrasound(VExUS)is emerging as a valuable bedside tool to gain real-time hemodynamic insights.This modality,derived from hepatic vein,portal vein,and intrarenal vessel Doppler patterns,offers a scoring system for dynamic venous congestion assessment.Such an assessment can be crucial in effective management of patients with heart failure exacerbation.It facilitates diagnosis,quantification of congestion,prognostication,and monitoring the efficacy of decongestive therapy.As such,it can effectively help to manage cardiorenal syndromes in various clinical settings.Extended or eVExUS explores additional veins,potentially broadening its applications.While VExUS demonstrates promising outcomes,challenges persist,particularly in cases involving renal and liver parenchymal disease,arrhythmias,and situations of pressure and volume overload overlap.Proficiency in utilizing spectral Doppler is pivotal for clinicians to effectively employ this tool.Hence,the integration of POCUS,especially advanced applications like VExUS,into routine clinical practice necessitates enhanced training across medical specialties.
基金Supported by Research funding from KidneyCure and the American Society of Nephrology’s William and Sandra Bennett Clinical Scholars Grant(to Abhilash Koratala).
文摘This article delves into the intricate challenges of acute kidney injury(AKI)in cirrhosis,a condition fraught with high morbidity and mortality.The complexities arise from distinguishing between various causes of AKI,particularly hemodynamic AKI,in cirrhotic patients,who experience hemodynamic changes due to portal hypertension.The term"hepatocardiorenal syndrome"is introduced to encapsulate the intricate interplay among the liver,heart,and kidneys.The narrative emphasizes the often-overlooked aspect of cardiac function in AKI assessments in cirrhosis,unveiling the prevalence of cirrhotic cardiomyopathy marked by impaired diastolic function.The conventional empiric approach involving volume expansion and vasopressors for hepatorenal syndrome is critically analyzed,highlighting potential risks and variable patient responses.We advocate for a nuanced algorithm for AKI evaluation in cirrhosis,prominently featuring point-of-care ultrasonography(POCUS).POCUS applications encompass assessing fluid tolerance,detecting venous congestion,and evaluating cardiac function.
基金This work was supported by Regional Collaborative Innovation Project of Xinjiang Uygur Autonomous Region(2022E02044).
文摘Esophageal tuberculosis(ET)is a relatively rare clinical condition,characterized by often atypical clinical features.The lack of specificity in diagnostic methods,such as esophagogastroduodenoscopy and various imaging techniques,frequently leads to misdiagnosis and inappropriate treatments.Compared to esophagogastroduodenoscopy,endoscopic ultrasonography(EUS)offers a more comprehensive examination of esophageal tuberculosis lesions,including the extent of wall layer involvement and the internal structure characteristics of the lesions.Furthermore,when necessary,endoscopic ultrasonography-guided fine-needle aspiration can be employed to acquire deeper pathological tissue,significantly aiding diagnosis.When combined with the patient’s clinical presentation,endoscopic findings,and pathological features,EUS plays a crucial role in the definitive diagnosis of ET and in the differential diagnosis process.This article meticulously reviews both national and international literature to summarize the relevant features of ET,with a focus on its appearance under EUS,and to highlight the clinical value of EUS in enhancing the diagnosis of ET and in distinguishing it from other conditions.The aim is to offer guidance for the accurate diagnosis of ET.
文摘BACKGROUND Few systematic comparative studies of the different methods of physical elastography of the spleen are currently available.AIM To compare point shear wave and two-dimensional elastography of the spleen considering the anatomical location(upper,hilar,and lower pole).METHODS As part of a prospective clinical study,healthy volunteers were examined for splenic elasticity using four different ultrasound devices between May 2015 and April 2017.The devices used for point shear wave elastography were from Siemens(S 3000)and Philips(Epiq 7),and those used for two-dimensional shear wave elastography were from GE(Logiq E9)and Toshiba(Aplio 500).In addition,two different software versions(5.0 and 6.0)were evaluated for the Toshiba ultrasound device(Aplio 500).The study consisted of three arms:A,B,and C.RESULTS In study arm A,200 subjects were evaluated(78 males and 122 females,mean age 27.9±8.1 years).In study arm B,113 subjects were evaluated(38 men and 75 women,mean age 26.0±6.3 years).In study arm C,44 subjects were enrolled.A significant correlation of the shear wave velocities at the upper third of the spleen(r=0.33088,P<0.0001)was demonstrated only for the Philips Epiq 7 device compared to the Siemens Acuson S 3000.In comparisons of the other ultrasound devices(GE,Siemens,Toshiba),no comparable results could be obtained for any anatomical position of the spleen.The influencing factors age,gender,and body mass index did not show a clear correlation with the measured shear wave velocities.CONCLUSION The absolute values of the shear wave elastography measurements of the spleen and the two different elastography methods are not comparable between different manufacturers or models.
基金This research was financially supported by the National Natural Science Foundation of China (Grant NO. 00000000) and the Fundamental Research Funds for Central University (Grant NO.TD2010-2).
文摘As a kind of subculture, The two-dimensional culture came of age during the 1970s in Japan and spread to China in the 1980s. In China, the culture has become an important economic force and social capital get more and more attention to it as well. This paper mainly discusses the origin and development of the two-dimensional clothing, and summed up the inherent characteristics and the internal developing law of it, furthermore, on the stage of current situation of two-dimensional economy this paper will conclude the development trend of next days.
文摘Endoscopic ultrasonography(EUS)represents the combination of endoscopy and intraluminal ultrasonography.This allows use of a high-frequency transducer(5-20 MHz)that,due to the short distance to the target lesion,provides ultrasonographic images of higher resolution than those obtained from other imaging modalities,including multiple-detector-row-computed tomography,magnetic resonance imaging,and positron emission tomography.EUS is now a widely accepted modality for diagnosing pancreatic diseases.However,the most important limitation of EUS has been the lack of specificity in differentiating between benign and malignant changes.In 1992,EUS-guided fine needle aspiration(FNA)of lesions in the pancreas head was introduced into clinical practice,using a curved linear-array echoendoscope.Since then,EUS has evolved from EUS imaging to EUSFNA and wider applications.Interventional EUS for pancreatic cancer includes EUS-FNA,EUS-guided fine needle injection,EUS-guided biliary drainage and anastomosis,EUS-guided celiac neurolysis,radiofrequency ablation,brachytherapy,and delivery of a growing number of anti-tumor agents.This review focuses on interventional EUS,including EUS-FNA and therapeutic EUS for pancreatic cancer.
文摘Some theorems of compactly supported non-tensor product form two-dimension Daubechies wavelet were analysed carefully. Compactly supported non-tensor product form two-dimension wavelet was constructed, then non-tensor product form two dimension wavelet finite element was used to solve the deflection problem of elastic thin plate. The error order was researched. A numerical example was given at last.
基金Sponsored by the National Natural Science Foundation of China(10676120)Laboratory of Computational Physics Foundation(9140C690101070C69)
文摘The adaptive mesh refinement (AMR) method is applied in the 2-D Euler multi-component elasticplastic hydrodynamics code (MEPH2Y). It is applied on detonation. Firstly, the AMR method is described, including a conservative spatial interpolation, the time integration methodology with the adapitve time increment and an adaptive computational region method. The advantage of AMR technique is exhibited by numerical examples, including the 1-D C-J detonation and the 2-D implosion ignited from a single point. Results show that AMR can promote the computational efficiency, keeping the accuracy in interesting regions.