Introduction: Ultrasound is an essential component of antenatal care. Midwives provide most of the antenatal care but they do not perform ultrasound as it has been beyond their scope of practice. This leaves many wome...Introduction: Ultrasound is an essential component of antenatal care. Midwives provide most of the antenatal care but they do not perform ultrasound as it has been beyond their scope of practice. This leaves many women in Low and Middle-Income Countries without access to ultrasound scanning. The aim of this study was to identify competencies in ultrasound scanning in midwifery education. Methods: A desk review and needs assessment were conducted between July and October 2023. Articles and curricula on the internet, Google scholar and PubMed were searched for content on ultrasound scanning competencies. A Google form consisting of 20 questions was administered via email and WhatsApp to 135 participants. Descriptive statistics were used to analyse data. Results: The desk review showed that it is feasible to train midwives in ultrasound scanning. The training programs for midwives in obstetric ultrasound were conducted for 1 week to 3 months with most of them running for 4 weeks. Content included introduction to general principles of ultrasound, physics, basic knowledge in embryology, obstetrics, anatomy, measuring foetal biometry, estimating amniotic fluid and gestational age. Experts like sonographers trained midwives. Theory and hands on were the teaching methods used. Written and practical assessments were conducted. Needs assessment revealed that majority of participants 71 (53%) knew about basic ultrasound training for midwives. All participants (100%) said it is necessary to train midwives in basic ultrasound scan in Zambia. Some content should include, anatomy, measuring foetal biometry, assessing amniotic fluid level, and gestational age determination. Most participants 91 (67%) suggested that the appropriate duration of training is 4 - 6 weeks. Conclusion: Empowering every midwife with ultrasound scanning skills will enable early detection of any abnormality among pregnant women and prompt intervention to save lives.展开更多
Alzheimer’s disease is a common neurodegenerative disorder defined by decreased reasoning abilities,memory loss,and cognitive deterioration.The presence of the blood-brain barrier presents a major obstacle to the dev...Alzheimer’s disease is a common neurodegenerative disorder defined by decreased reasoning abilities,memory loss,and cognitive deterioration.The presence of the blood-brain barrier presents a major obstacle to the development of effective drug therapies for Alzheimer’s disease.The use of ultrasound as a novel physical modulation approach has garnered widespread attention in recent years.As a safe and feasible therapeutic and drug-delivery method,ultrasound has shown promise in improving cognitive deficits.This article provides a summary of the application of ultrasound technology for treating Alzheimer’s disease over the past 5 years,including standalone ultrasound treatment,ultrasound combined with microbubbles or drug therapy,and magnetic resonance imaging-guided focused ultrasound therapy.Emphasis is placed on the benefits of introducing these treatment methods and their potential mechanisms.We found that several ultrasound methods can open the blood-brain barrier and effectively alleviate amyloid-βplaque deposition.We believe that ultrasound is an effective therapy for Alzheimer’s disease,and this review provides a theoretical basis for future ultrasound treatment methods.展开更多
AIM: To evaluate the diagnostic value of B-scan ultrasound and explore the cytological characteristics of patients with vitreoretinal lymphoma(VRL) and primary central nervous system lymphoma(PCNSL).METHODS: The clini...AIM: To evaluate the diagnostic value of B-scan ultrasound and explore the cytological characteristics of patients with vitreoretinal lymphoma(VRL) and primary central nervous system lymphoma(PCNSL).METHODS: The clinical data and pathologic specimens from patients with VRL diagnosed at the North Huashan Hospital from 2016 to 2017 were retrospectively reviewed. The patients were diagnosed by slit lamp ophthalmoscopy, B-scan ultrasound, cytology of the vitreous, which was obtained by vitrectomy, and cytokine measurements of interleukin(IL)-10 and IL-6.RESULTS: Twenty-six eyes(19.4%) out of 134 eyes of 67 patients(47 men and 20 women) with PCNSL were diagnosed with VRL by B-scan ultrasound, and 14 eyes(10.4%) were diagnosed by slit lamp ophthalmoscopy. Twenty-four eyes(17.9%) of 17 patients were confirmed as having VRL with cytology. No difference in the association between intracranial lesion location and ocular involvement was found. VRL patients had higher levels of vitreous IL-10 and IL-10/IL-6 when compared with macular hole cases, but the difference was not statistically significant.CONCLUSION: A total of 25.4% of the PCNSL patients had VRL, B-scan ultrasound examination had characteristic features and is recommended over slit lamp ophthalmoscopy for the screening diagnosis of PCNSL with intraocular involvement. Moreover, the cytological and immunohistochemical analyses performed after 25-gauge diagnostic vitrectomy were accurate diagnostic techniques.展开更多
High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound ...High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound imaging system. In this study, we utilized a linear servo with high noise tolerance and a novel multi-depth expression method to overcome those issues in developed high-speed image system. B-mode image of the chicken phantom by 25 MHz transducer shows the resolution of lateral and axial resolutions are up to 123 μm and 59 μm respectively. In addition, the experiment demonstrates that the axial resolution and depth of field (DOF) can be improved by time gain compensation(TGC) and multi-depth method. The results indicate that the proposed system could achieve over 24 fps for 1 mm scan distance and 100 lines per frame. In the future, the developed system is potential for other clinical applications such as ophthalmology and dermatology.展开更多
Background: Some researchers have suggested that when Naegle’s rule (NR) and Dubowitz score (DS) are combined, it could out-perform obstetric ultrasound scan (USS). Others still believe that obstetric USS alone is st...Background: Some researchers have suggested that when Naegle’s rule (NR) and Dubowitz score (DS) are combined, it could out-perform obstetric ultrasound scan (USS). Others still believe that obstetric USS alone is still effective relative to the combination of NR rule and DS in assessing the gestational age (GA) of babies. Objectives: To determine and compare the GA of babies using obstetric USS, NR and DS;and to provide relevant public health information on obstetric USS in the 21st century. Methods: Subjects were selected using systematic random sampling and the GA of babies was determined using obstetric USS, NR, and DS. Statistical package for social science (SPSS) statistical software version 16, Illinois, Chicago USA was used for all data analysis. Results: Eightyfive mother-baby pairs were studied. Forty-four babies (52%) were males and 41 (48%) females. Sixty four (75%) were term with a mean (SD) BW of 3.02 (0.59) at 95%CI (2.89 -?3.14) kg. The overall mean GA of the babies was 38.49 (2.89) at 95%CI (38.14 -?38.85) weeks. The mean GA using obstetric USS, NR and DS were 38.52 (1.98) at 95%CI (38.14 -?38.99), 38.09 (4.13) at 95%CI (37.20-?38.99) and 38.82 (2.02) at 95%CI (38.39 -?39.26), but comparison of these means was not significant (p = 0.256). Combined mean GA by NR and DS was 38.46 (3.26) at 95%CI (37.96 -?38.95). Comparing this mean with mean GA obtained by obstetric USS was also not significant (p = 0.885). Conclusion: The GA assessments by Obstetric USS, NR and DS were all reliable, and Obstetric USS performed effectively relative to combined NR and DS.展开更多
Morbid Adherent Placenta (MAP)/Placenta Accreta Spectrum (PAS) is a serious diagnosis which has a risk of complications. Ultrasound scan helps in early diagnosis and has great value in further confirmation and follow ...Morbid Adherent Placenta (MAP)/Placenta Accreta Spectrum (PAS) is a serious diagnosis which has a risk of complications. Ultrasound scan helps in early diagnosis and has great value in further confirmation and follow up. Observed new clinical sign and associated clinical triad are discussed here.展开更多
This paper presents a flexible and high speed digital scan converter (DSC) with the ability to handle high frequency ultrasound imaging in real-time. The characteristics in imaging system such as focus length of trans...This paper presents a flexible and high speed digital scan converter (DSC) with the ability to handle high frequency ultrasound imaging in real-time. The characteristics in imaging system such as focus length of transducer, the swing radius and sampling length etc. could be changed easily in compliance with the researcher's application based on this flexible digital scan converter. Linear interpolation is employed to achieve the coordinate transformations algorithm. Custom-built software is programmed to preliminarily handle the algorithm according to different ultrasound imaging applications. High performance FPGA will implement high speed interpolation calculation based on the preliminary data which are stored in the DDR2 SDRAM from the software. 64 bit 66 MHz PCI is employed to accomplish high speed data transmission. Experiment has shown that more than 500 frame rate could be achieved based on this high speed digital scan converter. The designed flexible and high speed digital scan converter could be used in current FPGA based high frequency ultrasound imaging system.展开更多
·AIM: To evaluate the accuracy of 20 MHz immersion Bscan ultrasonography in observing lens and to investigate the value of this noninvasive preoperative diagnosis method in alkali burn eyes.·METHODS: It was ...·AIM: To evaluate the accuracy of 20 MHz immersion Bscan ultrasonography in observing lens and to investigate the value of this noninvasive preoperative diagnosis method in alkali burn eyes.·METHODS: It was a comparative study. Fifty-six cases(56 eyes) of alkali burn eyes were examined by ultrasound biomicroscopy(UBM) and immersion 20 MHz B-scan ultrasonography from June 2011 to April 2013,the images were analyzed, and the ultrasonographic diagnosis compared with the operation results.·RESULTS: In 56 alkali burn eyes examined by UBM, the lens were not detected in 16 eyes; the IOL could be detected in 2 eyes; the anterior lens capsule surface or/and the front lens could be detected in 18 eyes, and lens opacification in 3 eyes of them; suspected abnormal lens were detected in the other 20 eyes. In all the same eyes examined by immersion 20 MHz B-scan ultrasonography,the lens were not detected in 16 eyes; the IOL could be detected in 2 eyes; 24 abnormal lens(opacity, lens expansion, shrinkage) and 14 normal lens were found.Compared with the intraoperative findings, the diagnostic accordance rate of the immersion 20 MHz B-scan appearance of lens was 100%(56/56), which was significantly higher than examined by UBM 57.14%(32/56)(χ2=30.55, P =0.0000).·CONCLUSION: Immersion 20 MHz B-scan ultrasonography can observe the lens accurately in alkali burn eyes. It has important clinical value to combine with UBM in eyes of alkali burn.展开更多
A rare differential diagnosis for severe abdominal pain is acute epiploic appendagitis. Its symptoms resemble those of acute diverticulitis, acute appendicitis, or omental infarction quite a bit. The primary imaging m...A rare differential diagnosis for severe abdominal pain is acute epiploic appendagitis. Its symptoms resemble those of acute diverticulitis, acute appendicitis, or omental infarction quite a bit. The primary imaging method used for diagnosis is computed tomography (CT). We are describing the case of a 27-year-old guy who underwent an abdominal ultrasonography after complaining of severe left lower quadrant abdominal pain. It identified an oval and non-compressible hyperechoic mass in the left iliac fossa. The mass was surrounded by a hypoechoic rim and there was no color Doppler signal. In the absence of CT, radiologists must be able to diagnose acute epiploic appendagitis on ultrasound in order to avoid unnecessary hospital admission, pricey laboratory tests, antibiotic treatment, and unnecessary surgery. In this instance, the patient was spared from ionization exposure from a potential CT scan and other invasive treatments including surgery with associated costs because of the reliable ultrasound diagnosis of epiploic appendagitis. After receiving conservative medical treatment, the patient was placed under surveillance and then discharged.展开更多
AIM To study the usefulness of orbital ultrasonography in the diagnosis of papilledema.METHODS Fifty patients who were referred to the neurophthalmology clinic and clinically suspected to have papilledema were selecte...AIM To study the usefulness of orbital ultrasonography in the diagnosis of papilledema.METHODS Fifty patients who were referred to the neurophthalmology clinic and clinically suspected to have papilledema were selected. Thorough, clinical examination with slitlamp biomicroscopy and visual acuity assessment was done. These patients underwent ultrasonography to demonstrate the crescent sign. The patients were further evaluated with the neurologist and magnetic resonance imaging(MRI) thus confirming the diagnosis of papilledema. The results of our ultrasonographic evaluation were correlated with final diagnosis after thorough clinical evaluation, imaging and the neurologist's opinion.RESULTS Out of 50 patients diagnosed having papilledema on MRI, 46(92%) showed crescent sign on B scan ultrasonography. Headache was most common presenting complaint in 47(94%) and idiopathic intracranial hypertension was most common underlying cause of papilledema in 30(60%) cases.CONCLUSION"Crescent sign" seen on ultrasonography is a sensitive tool for diagnosis of papilledema. It is cost effective, less cumbersome and effective tool to differentiatebetween papilledema and pseudo papilledema before subjecting the patients to costly investigations like MRI. A positive crescent sign should always be followed by MRI to find out the cause of papilledema.展开更多
Objective: The aim of the study was to discuss the value of ultrasound examination in the diagnosis of fetal gastric teratoma. Methods: We retrospectively analyzed 2 cases with fetal gastric teratoma in our hospital (...Objective: The aim of the study was to discuss the value of ultrasound examination in the diagnosis of fetal gastric teratoma. Methods: We retrospectively analyzed 2 cases with fetal gastric teratoma in our hospital (Department of Gynecology and Obstetrics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China). It involved clinical, ultrasonic, X-ray, CT and MRI, biochemical, pathological, karyotype and immunohistochemical data. Results: There both were hybrid echo masses in the abdominal of the fetus with the sonography and the ultrasound features which mostly like the teratomas. Two cases were dead after induced abortion. The pathological results of the mass were gastric immature teratoma in one, and stomach mature teratoma in another. Conclusion: Fetal gastric teratoma is rarely seen and easily be misdiagnosed in clinic. The diagnosis depends finally on pathological examination. Ultrasound scan as the easy and direct method is helpful to clew the diagnosis of fetal gastric teratoma.展开更多
Purpose: To compare the results by B-scan ultrasonography and findings in pars plana vitrectomy, and assess the diagnostic value of B-scan ultrasonography in endophthalmitis.Methods: Thirty eyes of 30 subjects diagnos...Purpose: To compare the results by B-scan ultrasonography and findings in pars plana vitrectomy, and assess the diagnostic value of B-scan ultrasonography in endophthalmitis.Methods: Thirty eyes of 30 subjects diagnosed as endophthalmitis were selected, who undergone preoperative B-scan ultrasonography. The result of pars plana vitrectomy was recorded. The above two results were compared.Results: On the evaluation of vitreous and retinal states in the patients with endophthal-mitis, the sensitivity of ultrasound was 90%~100%, and the specificity was 79%~100%. Poorer preoperative visual acuity was related with retinal detachment and retinal dissolution. The preoperative visual acuity in eyes with local vitreous opacity was better than with diffuse vitreous opacity.Conclusion: Comparison of the results of B-scan ultrasonography and the findings in pars plana vitrectomy showed B-scan ultrasonography is highly sensitive,specific, and is very helpful in the evaluation of endophthalmitis. B-scan ultrasonography can not only supply much information in the diagnosis of endophthalmitis but also inspect its trends and changes, which is helpful in the selection of treatment and planning the time of surgery.展开更多
Background: The objective of this study was to assess the additional yield of US and CT following a “negative” initial MIBI-scintigraphy (MIBI) in patients with primary hyperparathyroidism. Methods: Prospective data...Background: The objective of this study was to assess the additional yield of US and CT following a “negative” initial MIBI-scintigraphy (MIBI) in patients with primary hyperparathyroidism. Methods: Prospective data were collected regarding 100 consecutive patients, preferentially undergoing a minimally invasive parathyroidectomy (MIP). MIBI was the initial imaging study for localizing a solitary adenoma, followed by US and CT (US/CT) in “MIBI-negative”-patients. Results: Surgery led to normocalcemia in 98 patients (98%) after one operation. Overall 97 patients had solitary parathyroid disease while three patients had multiglandular disease. The sensitivity of imaging increased from 74% for MIBI alone to 92% following subsequent US/CT in “MIBI-negative”-patients. The positive predictive value of a “positive” MIBI was 96% and 76% of a positive US/CT following negative MIBI. The proportion of patients who underwent successful MIP increased from 60 to 72%. Conclusions: MIBI and the combination of US and CT are complementary imaging studies. Additional localization studies after a negative sestamibi scan enhances the number of patients with primary hyperparathyroidism profiting from a minimally invasive approach.展开更多
文摘Introduction: Ultrasound is an essential component of antenatal care. Midwives provide most of the antenatal care but they do not perform ultrasound as it has been beyond their scope of practice. This leaves many women in Low and Middle-Income Countries without access to ultrasound scanning. The aim of this study was to identify competencies in ultrasound scanning in midwifery education. Methods: A desk review and needs assessment were conducted between July and October 2023. Articles and curricula on the internet, Google scholar and PubMed were searched for content on ultrasound scanning competencies. A Google form consisting of 20 questions was administered via email and WhatsApp to 135 participants. Descriptive statistics were used to analyse data. Results: The desk review showed that it is feasible to train midwives in ultrasound scanning. The training programs for midwives in obstetric ultrasound were conducted for 1 week to 3 months with most of them running for 4 weeks. Content included introduction to general principles of ultrasound, physics, basic knowledge in embryology, obstetrics, anatomy, measuring foetal biometry, estimating amniotic fluid and gestational age. Experts like sonographers trained midwives. Theory and hands on were the teaching methods used. Written and practical assessments were conducted. Needs assessment revealed that majority of participants 71 (53%) knew about basic ultrasound training for midwives. All participants (100%) said it is necessary to train midwives in basic ultrasound scan in Zambia. Some content should include, anatomy, measuring foetal biometry, assessing amniotic fluid level, and gestational age determination. Most participants 91 (67%) suggested that the appropriate duration of training is 4 - 6 weeks. Conclusion: Empowering every midwife with ultrasound scanning skills will enable early detection of any abnormality among pregnant women and prompt intervention to save lives.
基金supported by the National Natural Science Foundation of China,Nos.82371886(to JY),81925020(to DM),82202797(to LW),and 82271218(to CZ).
文摘Alzheimer’s disease is a common neurodegenerative disorder defined by decreased reasoning abilities,memory loss,and cognitive deterioration.The presence of the blood-brain barrier presents a major obstacle to the development of effective drug therapies for Alzheimer’s disease.The use of ultrasound as a novel physical modulation approach has garnered widespread attention in recent years.As a safe and feasible therapeutic and drug-delivery method,ultrasound has shown promise in improving cognitive deficits.This article provides a summary of the application of ultrasound technology for treating Alzheimer’s disease over the past 5 years,including standalone ultrasound treatment,ultrasound combined with microbubbles or drug therapy,and magnetic resonance imaging-guided focused ultrasound therapy.Emphasis is placed on the benefits of introducing these treatment methods and their potential mechanisms.We found that several ultrasound methods can open the blood-brain barrier and effectively alleviate amyloid-βplaque deposition.We believe that ultrasound is an effective therapy for Alzheimer’s disease,and this review provides a theoretical basis for future ultrasound treatment methods.
基金Supported by the National Natural Science Foundation of China(No.81700123)the Shanghai Hospital Development Centre(No.16CR2043B)
文摘AIM: To evaluate the diagnostic value of B-scan ultrasound and explore the cytological characteristics of patients with vitreoretinal lymphoma(VRL) and primary central nervous system lymphoma(PCNSL).METHODS: The clinical data and pathologic specimens from patients with VRL diagnosed at the North Huashan Hospital from 2016 to 2017 were retrospectively reviewed. The patients were diagnosed by slit lamp ophthalmoscopy, B-scan ultrasound, cytology of the vitreous, which was obtained by vitrectomy, and cytokine measurements of interleukin(IL)-10 and IL-6.RESULTS: Twenty-six eyes(19.4%) out of 134 eyes of 67 patients(47 men and 20 women) with PCNSL were diagnosed with VRL by B-scan ultrasound, and 14 eyes(10.4%) were diagnosed by slit lamp ophthalmoscopy. Twenty-four eyes(17.9%) of 17 patients were confirmed as having VRL with cytology. No difference in the association between intracranial lesion location and ocular involvement was found. VRL patients had higher levels of vitreous IL-10 and IL-10/IL-6 when compared with macular hole cases, but the difference was not statistically significant.CONCLUSION: A total of 25.4% of the PCNSL patients had VRL, B-scan ultrasound examination had characteristic features and is recommended over slit lamp ophthalmoscopy for the screening diagnosis of PCNSL with intraocular involvement. Moreover, the cytological and immunohistochemical analyses performed after 25-gauge diagnostic vitrectomy were accurate diagnostic techniques.
文摘High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound imaging system. In this study, we utilized a linear servo with high noise tolerance and a novel multi-depth expression method to overcome those issues in developed high-speed image system. B-mode image of the chicken phantom by 25 MHz transducer shows the resolution of lateral and axial resolutions are up to 123 μm and 59 μm respectively. In addition, the experiment demonstrates that the axial resolution and depth of field (DOF) can be improved by time gain compensation(TGC) and multi-depth method. The results indicate that the proposed system could achieve over 24 fps for 1 mm scan distance and 100 lines per frame. In the future, the developed system is potential for other clinical applications such as ophthalmology and dermatology.
文摘Background: Some researchers have suggested that when Naegle’s rule (NR) and Dubowitz score (DS) are combined, it could out-perform obstetric ultrasound scan (USS). Others still believe that obstetric USS alone is still effective relative to the combination of NR rule and DS in assessing the gestational age (GA) of babies. Objectives: To determine and compare the GA of babies using obstetric USS, NR and DS;and to provide relevant public health information on obstetric USS in the 21st century. Methods: Subjects were selected using systematic random sampling and the GA of babies was determined using obstetric USS, NR, and DS. Statistical package for social science (SPSS) statistical software version 16, Illinois, Chicago USA was used for all data analysis. Results: Eightyfive mother-baby pairs were studied. Forty-four babies (52%) were males and 41 (48%) females. Sixty four (75%) were term with a mean (SD) BW of 3.02 (0.59) at 95%CI (2.89 -?3.14) kg. The overall mean GA of the babies was 38.49 (2.89) at 95%CI (38.14 -?38.85) weeks. The mean GA using obstetric USS, NR and DS were 38.52 (1.98) at 95%CI (38.14 -?38.99), 38.09 (4.13) at 95%CI (37.20-?38.99) and 38.82 (2.02) at 95%CI (38.39 -?39.26), but comparison of these means was not significant (p = 0.256). Combined mean GA by NR and DS was 38.46 (3.26) at 95%CI (37.96 -?38.95). Comparing this mean with mean GA obtained by obstetric USS was also not significant (p = 0.885). Conclusion: The GA assessments by Obstetric USS, NR and DS were all reliable, and Obstetric USS performed effectively relative to combined NR and DS.
文摘Morbid Adherent Placenta (MAP)/Placenta Accreta Spectrum (PAS) is a serious diagnosis which has a risk of complications. Ultrasound scan helps in early diagnosis and has great value in further confirmation and follow up. Observed new clinical sign and associated clinical triad are discussed here.
文摘This paper presents a flexible and high speed digital scan converter (DSC) with the ability to handle high frequency ultrasound imaging in real-time. The characteristics in imaging system such as focus length of transducer, the swing radius and sampling length etc. could be changed easily in compliance with the researcher's application based on this flexible digital scan converter. Linear interpolation is employed to achieve the coordinate transformations algorithm. Custom-built software is programmed to preliminarily handle the algorithm according to different ultrasound imaging applications. High performance FPGA will implement high speed interpolation calculation based on the preliminary data which are stored in the DDR2 SDRAM from the software. 64 bit 66 MHz PCI is employed to accomplish high speed data transmission. Experiment has shown that more than 500 frame rate could be achieved based on this high speed digital scan converter. The designed flexible and high speed digital scan converter could be used in current FPGA based high frequency ultrasound imaging system.
基金Supported by National Key Basic Research Program of China(973 Program,No.2013CB967001)National Natural Science Foundation of China(No.81271052,No.31271059)
文摘·AIM: To evaluate the accuracy of 20 MHz immersion Bscan ultrasonography in observing lens and to investigate the value of this noninvasive preoperative diagnosis method in alkali burn eyes.·METHODS: It was a comparative study. Fifty-six cases(56 eyes) of alkali burn eyes were examined by ultrasound biomicroscopy(UBM) and immersion 20 MHz B-scan ultrasonography from June 2011 to April 2013,the images were analyzed, and the ultrasonographic diagnosis compared with the operation results.·RESULTS: In 56 alkali burn eyes examined by UBM, the lens were not detected in 16 eyes; the IOL could be detected in 2 eyes; the anterior lens capsule surface or/and the front lens could be detected in 18 eyes, and lens opacification in 3 eyes of them; suspected abnormal lens were detected in the other 20 eyes. In all the same eyes examined by immersion 20 MHz B-scan ultrasonography,the lens were not detected in 16 eyes; the IOL could be detected in 2 eyes; 24 abnormal lens(opacity, lens expansion, shrinkage) and 14 normal lens were found.Compared with the intraoperative findings, the diagnostic accordance rate of the immersion 20 MHz B-scan appearance of lens was 100%(56/56), which was significantly higher than examined by UBM 57.14%(32/56)(χ2=30.55, P =0.0000).·CONCLUSION: Immersion 20 MHz B-scan ultrasonography can observe the lens accurately in alkali burn eyes. It has important clinical value to combine with UBM in eyes of alkali burn.
文摘A rare differential diagnosis for severe abdominal pain is acute epiploic appendagitis. Its symptoms resemble those of acute diverticulitis, acute appendicitis, or omental infarction quite a bit. The primary imaging method used for diagnosis is computed tomography (CT). We are describing the case of a 27-year-old guy who underwent an abdominal ultrasonography after complaining of severe left lower quadrant abdominal pain. It identified an oval and non-compressible hyperechoic mass in the left iliac fossa. The mass was surrounded by a hypoechoic rim and there was no color Doppler signal. In the absence of CT, radiologists must be able to diagnose acute epiploic appendagitis on ultrasound in order to avoid unnecessary hospital admission, pricey laboratory tests, antibiotic treatment, and unnecessary surgery. In this instance, the patient was spared from ionization exposure from a potential CT scan and other invasive treatments including surgery with associated costs because of the reliable ultrasound diagnosis of epiploic appendagitis. After receiving conservative medical treatment, the patient was placed under surveillance and then discharged.
文摘AIM To study the usefulness of orbital ultrasonography in the diagnosis of papilledema.METHODS Fifty patients who were referred to the neurophthalmology clinic and clinically suspected to have papilledema were selected. Thorough, clinical examination with slitlamp biomicroscopy and visual acuity assessment was done. These patients underwent ultrasonography to demonstrate the crescent sign. The patients were further evaluated with the neurologist and magnetic resonance imaging(MRI) thus confirming the diagnosis of papilledema. The results of our ultrasonographic evaluation were correlated with final diagnosis after thorough clinical evaluation, imaging and the neurologist's opinion.RESULTS Out of 50 patients diagnosed having papilledema on MRI, 46(92%) showed crescent sign on B scan ultrasonography. Headache was most common presenting complaint in 47(94%) and idiopathic intracranial hypertension was most common underlying cause of papilledema in 30(60%) cases.CONCLUSION"Crescent sign" seen on ultrasonography is a sensitive tool for diagnosis of papilledema. It is cost effective, less cumbersome and effective tool to differentiatebetween papilledema and pseudo papilledema before subjecting the patients to costly investigations like MRI. A positive crescent sign should always be followed by MRI to find out the cause of papilledema.
文摘Objective: The aim of the study was to discuss the value of ultrasound examination in the diagnosis of fetal gastric teratoma. Methods: We retrospectively analyzed 2 cases with fetal gastric teratoma in our hospital (Department of Gynecology and Obstetrics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China). It involved clinical, ultrasonic, X-ray, CT and MRI, biochemical, pathological, karyotype and immunohistochemical data. Results: There both were hybrid echo masses in the abdominal of the fetus with the sonography and the ultrasound features which mostly like the teratomas. Two cases were dead after induced abortion. The pathological results of the mass were gastric immature teratoma in one, and stomach mature teratoma in another. Conclusion: Fetal gastric teratoma is rarely seen and easily be misdiagnosed in clinic. The diagnosis depends finally on pathological examination. Ultrasound scan as the easy and direct method is helpful to clew the diagnosis of fetal gastric teratoma.
文摘Purpose: To compare the results by B-scan ultrasonography and findings in pars plana vitrectomy, and assess the diagnostic value of B-scan ultrasonography in endophthalmitis.Methods: Thirty eyes of 30 subjects diagnosed as endophthalmitis were selected, who undergone preoperative B-scan ultrasonography. The result of pars plana vitrectomy was recorded. The above two results were compared.Results: On the evaluation of vitreous and retinal states in the patients with endophthal-mitis, the sensitivity of ultrasound was 90%~100%, and the specificity was 79%~100%. Poorer preoperative visual acuity was related with retinal detachment and retinal dissolution. The preoperative visual acuity in eyes with local vitreous opacity was better than with diffuse vitreous opacity.Conclusion: Comparison of the results of B-scan ultrasonography and the findings in pars plana vitrectomy showed B-scan ultrasonography is highly sensitive,specific, and is very helpful in the evaluation of endophthalmitis. B-scan ultrasonography can not only supply much information in the diagnosis of endophthalmitis but also inspect its trends and changes, which is helpful in the selection of treatment and planning the time of surgery.
文摘Background: The objective of this study was to assess the additional yield of US and CT following a “negative” initial MIBI-scintigraphy (MIBI) in patients with primary hyperparathyroidism. Methods: Prospective data were collected regarding 100 consecutive patients, preferentially undergoing a minimally invasive parathyroidectomy (MIP). MIBI was the initial imaging study for localizing a solitary adenoma, followed by US and CT (US/CT) in “MIBI-negative”-patients. Results: Surgery led to normocalcemia in 98 patients (98%) after one operation. Overall 97 patients had solitary parathyroid disease while three patients had multiglandular disease. The sensitivity of imaging increased from 74% for MIBI alone to 92% following subsequent US/CT in “MIBI-negative”-patients. The positive predictive value of a “positive” MIBI was 96% and 76% of a positive US/CT following negative MIBI. The proportion of patients who underwent successful MIP increased from 60 to 72%. Conclusions: MIBI and the combination of US and CT are complementary imaging studies. Additional localization studies after a negative sestamibi scan enhances the number of patients with primary hyperparathyroidism profiting from a minimally invasive approach.