期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Point-of-care ultrasound in diagnosis and management of congestive nephropathy
1
作者 Michael Turk Thomas Robertson Abhilash Koratala 《World Journal of Critical Care Medicine》 2023年第2期53-62,共10页
Congestive nephropathy is kidney dysfunction caused by the impact of elevated venous pressures on renal hemodynamics.As a part of cardiorenal syndrome,the diagnosis is usually made based on history and physical examin... Congestive nephropathy is kidney dysfunction caused by the impact of elevated venous pressures on renal hemodynamics.As a part of cardiorenal syndrome,the diagnosis is usually made based on history and physical examination,with findings such as jugular venous distension,a third heart sound,and vital signs as supporting findings.More recently,however,these once though objective measures have come under scrutiny for their accuracy.At the same time,bedside ultrasound has increased in popularity and is routinely being used by clinicians to take some of the guess work out of making the diagnosis of volume overload and venous congestion.In this mini-review,we will discuss some of the traditional methods used to measure venous congestion,describe the role of point-of-care ultrasound and how it can ameliorate a clinician’s evaluation,and offer a description of venous excess ultrasound score,a relatively novel scoring technique used to objectively quantify congestion.While there is a paucity of published large scale clinical trials evaluating the potential benefit of ultrasonography in venous congestion compared to gold standard invasive measurements,more study is underway to solidify the role of this objective measure in daily clinical practice. 展开更多
关键词 ultrasound Point-of-care ultrasonography Doppler Venous excess ultrasound score Congestion Hemodynamics Heart failure NEPHROLOGY
下载PDF
Ultrasound Guidance and Nerve Stimulation Combined Versus Nerve Stimulation alone for Lumbar Plexus Block:A Randomized Controlled Trial 被引量:3
2
作者 Jing-yu XIAO Yan FANG +4 位作者 Yao YU Jian LI Ya-ru LUO Yong LIU Wei MEI 《Current Medical Science》 SCIE CAS 2020年第6期1182-1190,共9页
A nerve stimulation-guided lumbar plexus block is a well-established technique.It is not clear whether ultrasound guidance has additional value for this deep block technique.This study aimed to examine whether ultraso... A nerve stimulation-guided lumbar plexus block is a well-established technique.It is not clear whether ultrasound guidance has additional value for this deep block technique.This study aimed to examine whether ultrasound guidance using a paramedian transverse scan through the intertransverse space(PMTS-ITS)approach in combination with nerve stimulation reduces the onset time of a complete sensory block.Forty-four patients who were scheduled to undergo arthroscopic knee surgery with an ultrasound visibility score(UVS)of≥10 for the lumbar plexus were enrolled and randomly allocated to the ultrasound guidance with nerve stimulation group(group U-N)or nerve stimulation group(group N)in this prospective,randomized,parallel-group,active-controlled study.The primary outcome was the onset time of a complete sensory block.The results showed that the onset time of a complete sensory block to pinprick and cold was 10(10–40)min and 10(10–40)min in group U-N,respectively,and 30(10–40)min and 20(10–40)min in group N(P=0.005,P=0.004),respectively.The performance time was 658±87 s in group U-N and 528±97 s in group N(P<0.001).There was no(0%)patient who required 5 or more needle passes in group U-N and 6(27.3%)in group N(P=0.028).The block failure rate was 9.1%in group U-N and 31.8%in group N(P>0.05).In conclusion,ultrasound guidance using the PMTS-ITS approach in combination with nerve stimulation led to a faster onset of a complete sensory block than nerve stimulation alone for a lumbar plexus block in patients with a UVS≥10.Ultrasound guidance with nerve stimulation significantly decreased the number of patients who required 5 or more needle passes. 展开更多
关键词 lumbar plexus block ultrasound guidance nerve stimulation ultrasound visibility score
下载PDF
Predictive Score for Pulmonary Ultrasound and Factors Associated to Mortality and Hospitalization during the Covid-19 Pandemic 被引量:1
3
作者 Leandro Seoane Adrian Ruggiero +5 位作者 Anabela Martinelli Cristian Noriega Martin Diana Menendez Marcelo Rodriguez Natalia Cano Lourdes Posadas 《Open Journal of Emergency Medicine》 2022年第4期210-219,共10页
Pulmonary ultrasound is a non-invasive bedside resource that has showed to be useful for the assessment of patients presenting with respiratory insufficiency as well as the diagnosis of several pleural and other pulmo... Pulmonary ultrasound is a non-invasive bedside resource that has showed to be useful for the assessment of patients presenting with respiratory insufficiency as well as the diagnosis of several pleural and other pulmonary pathologies. The pulmonary ultrasound score (LUS) is a semi quantitative scale that measures the loss of pulmonary aeration cause by many pathologic conditions. Our primary objective was to describe factors associated to death and hospitalization in patients aged 16 or older that were admitted to the emergency department (ED) with signs or symptoms of COVID-19 infection through the diagnosis of viral pneumonia with pulmonary ultrasound (PU). It was a cohort retrospective study through a one-year period. Emergency physicians performed lung ultrasounds and calculated LUS. Results: 672 patients suspected of COVID-19 infection with a PU finding of viral pneumonia were included. 495 patients had a positive COVID-19 PCR test, 73.6% of the population. 258 patients presented with high probability of COVID-19 pneumonia following the patterns in PU. 55% were male with a median age of 45 years old. The average LUS score at admission was 8. Global hospitalization rate was 51.5%, 7.5% were admitted to the ICU. Patients with a LUS > 10 had a mortality of 6%, and patients admitted to the ICU had a 50% mortality rate. They presented with an average LUS score at admission of 15.2. Conclusions: LUS was a good predictor of death, hospitalization to general ward or ICU of patients with COVID-19 admitted from the emergency department. 展开更多
关键词 Pulmonary ultrasound COVID-19 Pulmonary ultrasound Score Emergency Physicians Viral Pneumonia
下载PDF
Bedside cardiopulmonary ultrasonography evaluates lung water content in very low-weight preterm neonates with patent ductus arteriosus 被引量:2
4
作者 Li-Fang Yu Chen-Ke Xu +3 位作者 Min Zhao Lin Niu Xian-Mei Huang Zhi-Qun Zhang 《World Journal of Clinical Cases》 SCIE 2021年第8期1827-1834,共8页
BACKGROUND Patent ductus arteriosus(PDA)is a common congenital heart abnormality in preterm neonates with a high incidence in neonates with very low birth weights.When PDA persists,interstitial lung water content incr... BACKGROUND Patent ductus arteriosus(PDA)is a common congenital heart abnormality in preterm neonates with a high incidence in neonates with very low birth weights.When PDA persists,interstitial lung water content increases,which could lead to abnormal circulation hemodynamics and pulmonary edema.It is important to perform early and reliable assessment of lung water content in very low-weight preterm neonates with persistent PDA.AIM To evaluate the role of bedside cardiopulmonary ultrasonography in the lung water content assessment in very low-weight preterm neonates with persistent PDA.METHODS From January 2018 to March 2020,69 very low-weight preterm neonates with echocardiography-confirmed PDA were selected as the PDA group.At the same time,89 very low-weight preterm neonates without PDA were randomly selected as the control group.All neonates underwent echocardiography and 6-segment lung ultrasonography on the fourth day after birth.The clinical characteristics and main ultrasonography results were compared between the two groups.Pearson’s analysis was used to analyze the correlation between lung ultrasonography score(LUS)and other related clinical and ultrasonography results in all neonates.In the PDA group,PDA diameters were recorded,and the correlation with LUS and left atrium to aortic(LA/AO)dimension ratio were also analyzed.LA/AO ratio is one of the ultrasonic diagnostic criteria for hemodynamically significant PDA.When the ratio is≥1.5,it suggests the possibility of hemodynamic changes in persistent PDA.A receiver operating characteristic curve was established using the sensitivity of LUS to predict the hemodynamic changes in neonates with PDA as the ordinate and 1-specificity as the abscissa.RESULTS A total of 158 neonates were enrolled in this study,including 69 in the PDA group and 89 in the control group.There were no statistical differences in sex,gestational age,birth weight,ventilator dependence,hospitalization length and left ventricular ejection fraction between the two groups(P>0.05).The LUS and LA/AO ratio in the PDA group were higher than those in the control group(P<0.05),but there was no difference of LUS in neonates with or without use of the ventilator(t=0.58,P=0.16).In all cases,LUS was negatively correlated with gestational age(r=-0.28,P<0.01)and birth weight(r=-0.36,P<0.01),while positively correlated with the LA/AO ratio(r=0.27,P<0.01).In the PDA group,PDA diameter was positively correlated with the LA/AO ratio(r=0.39,P<0.01)and LUS(r=0.31,P<0.01).Receiver operating characteristic results showed that LUS had the moderate accuracy for predicting hemodynamic changes in PDA(area under the curve=0.741;sensitivity=93.75%;specificity=50.94%).CONCLUSION Bedside cardiopulmonary ultrasonography can evaluate lung content in neonates with PDA and predict the possibility of hemodynamic changes in persistent PDA. 展开更多
关键词 Patent ductus arteriosus CARDIOPULMONARY ULTRASONOGRAPHY Lung ultrasound score Very low-weight neonates PRETERM
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部