期刊文献+
共找到491篇文章
< 1 2 25 >
每页显示 20 50 100
The Application Value of Ultrasound Imaging in the Differential Diagnosis of Benign and Malignant Breast Nodules of BI-RADS 3 and Above
1
作者 Dongmei Chen 《Proceedings of Anticancer Research》 2024年第2期53-58,共6页
Objective:To explore the diagnostic value of ultrasound imaging for breast nodules of breast imaging-reporting and data system(BI-RADS)category 3 and above.Methods:From June 2021 to July 2022,163 patients with breast ... Objective:To explore the diagnostic value of ultrasound imaging for breast nodules of breast imaging-reporting and data system(BI-RADS)category 3 and above.Methods:From June 2021 to July 2022,163 patients with breast nodules of BI-RADS 3 or above were selected as the research subjects.After pathological diagnosis,24 cases were malignant breast nodules of BI-RADS 3 or above,while 139 cases were benign breast nodules of BI-RADS 3 or above.The diagnosis rate of malignant and benign breast nodules of BI-RADS 3 or above,including 95%CI,was observed and analyzed.Results:The malignant and benign detection rates of conventional ultrasound were 88.63%and 75.00%,respectively,and the malignant and benign detection rates of ultrasound imaging were 93.18%and 87.50%,respectively,with 95%CIs greater than 0.7.Conclusion:Ultrasound imaging can help improve the diagnostic accuracy of benign and malignant breast nodules of BI-RADS 3 and above and reduce the misdiagnosis rate. 展开更多
关键词 ultrasound ultrasound imaging breast imaging-reporting and data system(bi-rads)category 3 and above Diagnosis
下载PDF
Ovarian-adnexal reporting and data system ultrasound evaluation and pathological characteristics of ovarian collision tumor
2
作者 Chan Yin Yong Wang +3 位作者 Zhi-Hui Fei Li-Hong Sun Wei-Ai Zhou Heng Li 《World Journal of Clinical Cases》 SCIE 2024年第22期4932-4939,共8页
BACKGROUND Collision tumor are neoplasms,including two histologically distinct tumors that coexist in the same mass without histological admixture.The incidence of collision tumor is low and is rare clinically.AIM To ... BACKGROUND Collision tumor are neoplasms,including two histologically distinct tumors that coexist in the same mass without histological admixture.The incidence of collision tumor is low and is rare clinically.AIM To investigate ultrasound images and application of ovarian-adnexal reporting and data system(O-RADS)to evaluate the risk and pathological characteristics of ovarian collision tumor.METHODS This study retrospectively analyzed 17 cases of ovarian collision tumor diagnosed pathologically from January 2020 to December 2023.All clinical features,ultrasound images and histopathological features were collected and analyzed.The O-RADS score was used for classification.The O-RADS score was determined by two senior doctors in the gynecological ultrasound group.Lesions with O-RADS score of 1-3 were classified as benign tumors,and lesions with O-RADS score of 4 or 5 were classified as malignant tumors.RESULTS There were 17 collision tumors detected in 16 of 6274 patients who underwent gynecological surgery.The average age of 17 women with ovarian collision tumor was 36.7 years(range 20-68 years),in whom,one occurred bilaterally and the rest occurred unilaterally.The average tumor diameter was 10 cm,of which three were 2-5 cm,11 were 5-10 cm,and three were>10 cm.Five(29.4%)tumors with O-RADS score 3 were endometriotic cysts with fibroma/serous cystadenoma,and unilocular or multilocular cysts contained a small number of parenchymal components.Eleven(64.7%)tumors had an O-RADS score of 4,including two in category 4A,six in category 4B,and three in category 4C;all of which were multilocular cystic tumors with solid components or multiple papillary components.One(5.9%)tumor had an O-RADS score of 5.This case was a solid mass,and a small amount of pelvic effusion was detected under ultrasound.The pathology was high-grade serous cystic cancer combined with cystic mature teratoma.There were nine(52.9%)tumors with elevated serum carbohydrate antigen(CA)125 and two(11.8%)with elevated serum CA19-9.Histological and pathological results showed that epithelial-cell-derived tumors combined with other tumors were the most common,which was different from previous results.CONCLUSION The ultrasound images of ovarian collision tumor have certain specificity,but diagnosis by preoperative ultrasound is difficult.The combination of epithelial and mesenchymal cell tumors is one of the most common types of ovarian collision tumor.The O-RADS score of ovarian collision tumor is mostly≥4,which can sensitively detect malignant tumors. 展开更多
关键词 Ovarian collision tumor Ovarian-adnexal reporting and data system Epithelial tumor Serous cystadenoma ultrasound images
下载PDF
Contrast-enhanced ultrasound improved performance of breast imaging reporting and data system evaluation of critical breast lesions 被引量:18
3
作者 Jun Luo Ji-Dong Chen +6 位作者 Qing Chen Lin-Xian Yue Guo Zhou Cheng Lan Yi Li Chi-Hua Wu Jing-Qiao Lu 《World Journal of Radiology》 CAS 2016年第6期610-617,共8页
AIM: To determine whether contrast-enhanced ultrasound(CEUS) can improve the precision of breast imaging reporting and data system(BI-RADS) categorization. METHODS: A total of 230 patients with 235 solid breast lesion... AIM: To determine whether contrast-enhanced ultrasound(CEUS) can improve the precision of breast imaging reporting and data system(BI-RADS) categorization. METHODS: A total of 230 patients with 235 solid breast lesions classified as BI-RADS 4 on conventional ultrasound were evaluated. CEUS was performed within one week before core needle biopsy or surgical resection and a revised BI-RADS classification was assigned based on 10 CEUS imaging characteristics. Receiver operating characteristic curve analysis was then conducted to evaluate the diagnostic performance of CEUS-based BI-RADS assignment with pathological examination as reference criteria. RESULTS: The CEUS-based BI-RADS evaluation classified 116/235(49.36%) lesions into category 3, 20(8.51%), 13(5.53%) and 12(5.11%) lesions into categories 4A, 4B and 4C, respectively, and 74(31.49%) into category 5. Selecting CEUS-based BI-RADS category 4A as an appropriate cut-off gave sensitivity and specificity values of 85.4% and 87.8%, respectively, for the diagnosisof malignant disease. The cancer-to-biopsy yield was 73.11% with CEUS-based BI-RADS 4A selected as the biopsy threshold compared with 40.85% otherwise, while the biopsy rate was only 42.13% compared with 100% otherwise. Overall, only 4.68% of invasive cancers were misdiagnosed.CONCLUSION: This pilot study suggests that evaluation of BI-RADS 4 breast lesions with CEUS results in reduced biopsy rates and increased cancer-to-biopsy yields. 展开更多
关键词 breast imaging reporting and data system CONTRAST-ENHANCED ultrasound BIOPSY False POSITIVE BIOPSY
下载PDF
Predictive model for contrast-enhanced ultrasound of the breast: Is it feasible in malignant risk assessment of breast imaging reporting and data system 4 lesions? 被引量:10
4
作者 Jun Luo Ji-Dong Chen +6 位作者 Qing Chen Lin-Xian Yue Guo Zhou Cheng Lan Yi Li Chi-Hua Wu Jing-Qiao Lu 《World Journal of Radiology》 CAS 2016年第6期600-609,共10页
AIM: To build and evaluate predictive models for contrast-enhanced ultrasound(CEUS) of the breast to distinguish between benign and malignant lesions. METHODS: A total of 235 breast imaging reporting and data system(B... AIM: To build and evaluate predictive models for contrast-enhanced ultrasound(CEUS) of the breast to distinguish between benign and malignant lesions. METHODS: A total of 235 breast imaging reporting and data system(BI-RADS) 4 solid breast lesions were imaged via CEUS before core needle biopsy or surgical resection. CEUS results were analyzed on 10 enhancing patterns to evaluate diagnostic performance of three benign and three malignant CEUS models, with pathological results used as the gold standard. A logistic regression model was developed basing on the CEUS results, and then evaluated with receiver operating curve(ROC). RESULTS: Except in cases of enhanced homogeneity, the rest of the 9 enhancement appearances were statistically significant(P < 0.05). These 9 enhancement patterns were selected in the final step of the logistic regression analysis, with diagnostic sensitivity and specificity of 84.4% and 82.7%, respectively, and the area under the ROC curve of 0.911. Diagnostic sensitivity, specificity, and accuracy of the malignant vs benign CEUS models were 84.38%, 87.77%, 86.38% and 86.46%, 81.29% and 83.40%, respectively. CONCLUSION: The breast CEUS models can predict risk of malignant breast lesions more accurately, decrease false-positive biopsy, and provide accurate BIRADS classification. 展开更多
关键词 breast CONTRAST-ENHANCED ultrasound Qualitative analysis breast imaging reporting and data system PREDICTIVE model
下载PDF
Contrast-enhanced ultrasound Liver Imaging Reporting and Data System:Lights and shadows in hepatocellular carcinoma and cholangiocellular carcinoma diagnosis 被引量:6
5
作者 Gianpaolo Vidili Marco Arru +13 位作者 Giuliana Solinas Diego Francesco Calvisi Pierluigi Meloni Assunta Sauchella Davide Turilli Claudio Fabio Antonio Cossu Giordano Madeddu Sergio Babudieri Maria Assunta Zocco Giovanni Iannetti Enza Di Lembo Alessandro Palmerio Delitala Roberto Manetti 《World Journal of Gastroenterology》 SCIE CAS 2022年第27期3488-3502,共15页
BACKGROUND Contrast-enhanced ultrasound(CEUS)is considered a secondary examination compared to computed tomography(CT)and magnetic resonance imaging(MRI)in the diagnosis of hepatocellular carcinoma(HCC),due to the ris... BACKGROUND Contrast-enhanced ultrasound(CEUS)is considered a secondary examination compared to computed tomography(CT)and magnetic resonance imaging(MRI)in the diagnosis of hepatocellular carcinoma(HCC),due to the risk of misdiagnosing intrahepatic cholangiocarcinoma(ICC).The introduction of CEUS Liver Imaging Reporting and Data System(CEUS LI-RADS)might overcome this limitation.Even though data from the literature seems promising,its reliability in real-life context has not been well-established yet.AIM To test the accuracy of CEUS LI-RADS for correctly diagnosing HCC and ICC in cirrhosis.METHODS CEUS LI-RADS class was retrospectively assigned to 511 nodules identified in 269 patients suffering from liver cirrhosis.The diagnostic standard for all nodules was either biopsy(102 nodules)or CT/MRI(409 nodules).Common diagnostic accuracy indexes such as sensitivity,specificity,positive predictive value(PPV),and negative predictive value(NPV)were assessed for the following associations:CEUS LR-5 and HCC;CEUS LR-4 and 5 merged class and HCC;CEUS LR-M and ICC;and CEUS LR-3 and malignancy.The frequency of malignant lesions in CEUS LR-3 subgroups with different CEUS patterns was also determined.Inter-rater agreement for CEUS LI-RADS class assignment and for major CEUS pattern identification was evaluated.RESULTS CEUS LR-5 predicted HCC with a 67.6%sensitivity,97.7%specificity,and 99.3%PPV(P<0.001).The merging of LR-4 and 5 offered an improved 93.9%sensitivity in HCC diagnosis with a 94.3%specificity and 98.8%PPV(P<0.001).CEUS LR-M predicted ICC with a 91.3%sensitivity,96.7%specificity,and 99.6%NPV(P<0.001).CEUS LR-3 predominantly included benign lesions(only 28.8%of malignancies).In this class,the hypo-hypo pattern showed a much higher rate of malignant lesions(73.3%)than the iso-iso pattern(2.6%).Inter-rater agreement between internal raters for CEUS-LR class assignment was almost perfect(n=511,k=0.94,P<0.001),while the agreement among raters from separate centres was substantial(n=50,k=0.67,P<0.001).Agreement was stronger for arterial phase hyperenhancement(internal k=0.86,P<2.7×10-214;external k=0.8,P<0.001)than washout(internal k=0.79,P<1.6×10-202;external k=0.71,P<0.001).CONCLUSION CEUS LI-RADS is effective but can be improved by merging LR-4 and 5 to diagnose HCC and by splitting LR-3 into two subgroups to differentiate iso-iso nodules from other patterns. 展开更多
关键词 Contrast-enhanced ultrasound Liver imaging reporting and data System Hepatocellular carcinoma Intrahepatic cholangiocarcinoma CIRRHOSIS Contrast-enhanced ultrasound LIVER
下载PDF
Interobserver agreement for contrast-enhanced ultrasound of liver imaging reporting and data system:A systematic review and metaanalysis 被引量:2
6
作者 Jun Li Ming Chen +7 位作者 Zi-Jing Wang Shu-Gang Li Meng Jiang Long Shi Chun-Li Cao Tian Sang Xin-Wu Cui Christoph F Dietrich 《World Journal of Clinical Cases》 SCIE 2020年第22期5589-5602,共14页
BACKGROUND Hepatocellular carcinoma is the most common primary liver malignancy.From the results of previous studies,Liver Imaging Reporting and Data System(LIRADS)on contrast-enhanced ultrasound(CEUS)has shown satisf... BACKGROUND Hepatocellular carcinoma is the most common primary liver malignancy.From the results of previous studies,Liver Imaging Reporting and Data System(LIRADS)on contrast-enhanced ultrasound(CEUS)has shown satisfactory diagnostic value.However,a unified conclusion on the interobserver stability of this innovative ultrasound imaging has not been determined.The present metaanalysis examined the interobserver agreement of CEUS LI-RADS to provide some reference for subsequent related research.AIM To evaluate the interobserver agreement of LI-RADS on CEUS and analyze the sources of heterogeneity between studies.METHODS Relevant papers on the subject of interobserver agreement on CEUS LI-RADS published before March 1,2020 in China and other countries were analyzed.The studies were filtered,and the diagnostic criteria were evaluated.The selected references were analyzed using the“meta”and“metafor”packages of R software version 3.6.2.RESULTS Eight studies were ultimately included in the present analysis.Meta-analysis results revealed that the summary Kappa value of included studies was 0.76[95%confidence interval,0.67-0.83],which shows substantial agreement.Higgins I2 statistics also confirmed the substantial heterogeneity(I2=91.30%,95%confidence interval,85.3%-94.9%,P<0.01).Meta-regression identified the variables,including the method of patient enrollment,method of consistency testing,and patient race,which explained the substantial study heterogeneity.CONCLUSION CEUS LI-RADS demonstrated overall substantial interobserver agreement,but heterogeneous results between studies were also obvious.Further clinical investigations should consider a modified recommendation about the experimental design. 展开更多
关键词 Contrast-enhanced ultrasound Liver imaging reporting and data system Interobserver agreement Systematic review DIAGNOSIS META-ANALYSIS
下载PDF
2013年版超声BI-RADS出版10年:回顾与展望 被引量:1
7
作者 卫旻炎 周建桥 《肿瘤影像学》 2024年第1期13-19,共7页
自2013年美国放射学会出版第二版乳腺影像报告和数据系统(Breast Imaging Reporting and Data System,BI-RADS)后,乳腺超声的临床实践与科学研究均从中获益。本文总结了2013年版超声BI-RADS出版这10年间,乳腺超声影像技术临床应用与革... 自2013年美国放射学会出版第二版乳腺影像报告和数据系统(Breast Imaging Reporting and Data System,BI-RADS)后,乳腺超声的临床实践与科学研究均从中获益。本文总结了2013年版超声BI-RADS出版这10年间,乳腺超声影像技术临床应用与革新、存在的问题与面临的挑战及未来的发展机遇,以期为临床诊治、指南推广与应用提供帮助。 展开更多
关键词 乳腺超声 乳腺影像报告和数据系统 超声 弹性成像 人工智能
下载PDF
自动乳腺容积超声成像在BI-RADS4A类乳腺结节诊断中的价值 被引量:1
8
作者 刘晓琳 陈铃 +1 位作者 陈欣欣 梁伟翔 《国际医药卫生导报》 2024年第9期1469-1473,共5页
目的探讨自动乳腺容积超声成像(ABUS)在乳腺影像报告和数据系统(BI-RADS)4A类乳腺结节良、恶性诊断中的应用价值。方法回顾性分析广东省中医院2018年1月至2022年9月经ABUS发现乳腺BI-RADS 4A类结节的202例女性患者,共216个乳腺结节[结... 目的探讨自动乳腺容积超声成像(ABUS)在乳腺影像报告和数据系统(BI-RADS)4A类乳腺结节良、恶性诊断中的应用价值。方法回顾性分析广东省中医院2018年1月至2022年9月经ABUS发现乳腺BI-RADS 4A类结节的202例女性患者,共216个乳腺结节[结节最大径(17.92±11.60)mm],年龄23~72岁。患者均接受ABUS、常规超声、乳腺X线摄影,并根据美国放射学会(ACR)建立的2013年版BI-RADS进行分类,以术后病理结果作为金标准,分析3种检查方法的诊断效能。计数资料的比较采用χ^(2)检验或Fisher确切概率法。结果经手术病理证实,178个结节为良性,38个结节为恶性,ABUS、常规超声、乳腺X线摄影诊断BI-RADS 4A类结节的恶性构成比分别为17.59%(38/216)、12.94%(22/170)、19.61%(10/51),3种检查诊断BI-RADS 4A类结节的恶性构成比进行组间比较(ABUS与常规超声、ABUS与X线、常规超声与X线),差异均无统计学意义(χ^(2)=1.568、0.114、1.408,均P>0.05)。结论ABUS对BI-RADS 4A类乳腺结节的诊断效能与常规超声、乳腺X线摄影相仿,ABUS在早期乳腺癌筛查中有一定临床价值,有利于基层单位乳腺疾病筛查及疾病分级管理。 展开更多
关键词 乳腺结节病 自动乳腺容积超声成像 乳腺影像报告和数据系统 诊断
下载PDF
超声造影联合年龄在乳腺BI-RADS 4类结节再分类中的应用价值
9
作者 陈芮 周鸿 +2 位作者 翟蓓 杨兴洲 赵宇心 《成都医学院学报》 CAS 2024年第3期415-418,共4页
目的 探讨超声造影联合年龄在乳腺影像学报告及数据系统(BI-RADS)4类结节再分类中的应用价值。方法 收集成都市第三人民医院常规超声分类为BI-RADS 4类,且经过超声造影评分并有病理结果的116个乳腺结节患者的临床资料。以病理诊断为金标... 目的 探讨超声造影联合年龄在乳腺影像学报告及数据系统(BI-RADS)4类结节再分类中的应用价值。方法 收集成都市第三人民医院常规超声分类为BI-RADS 4类,且经过超声造影评分并有病理结果的116个乳腺结节患者的临床资料。以病理诊断为金标准,构建受试者工作特征(ROC)曲线,计算超声造影评分及年龄诊断乳腺良恶性结节的最佳截断值,并分析其诊断价值。利用超声造影评分及年龄的最佳截断值,对116个BI-RADS 4类结节重新进行分类调整。结果 通过绘制ROC曲线得到超声造影评分的最佳截断值为3.5分,年龄的最佳截断值为50.5岁。超声造影评分的ROC曲线下面积为0.887,其诊断乳腺结节良恶性的敏感性及特异性分别为80.8%、96.7%;年龄的ROC曲线下面积为0.793,其诊断乳腺结节良恶性的敏感性及特异性分别为73.1%、85.6%。BI-RADS 4类结节经超声造影评分联合年龄临界值重新调整后,59个结节降为3类,病理结果均为良性;11个结节升为4c类,病理结果均为恶性。结论 超声造影评分联合年龄对BI-RADS 4类结节进行重新分类后可有效提高乳腺结节诊断的准确性,能为临床诊疗提供参考。 展开更多
关键词 乳腺结节 bi-rads分类 超声造影 年龄
下载PDF
多模态超声校正BI-RADS 4类乳腺肿块的价值
10
作者 黄思 肖耀成 +3 位作者 金林原 张敏 李建 张艳芬 《分子影像学杂志》 2024年第1期52-56,共5页
目的 探讨乳腺自动容积成像(ABVS)、超声弹性评分(UES)及两者联合在校正乳腺影像报告和数据系统分级(BI-RADS) 4类乳腺肿块BI-RADS分级中的应用价值。方法 收集我院经常规超声诊断为BI-RADS 4类的乳腺肿块患者109例,共113个肿块。经ABVS... 目的 探讨乳腺自动容积成像(ABVS)、超声弹性评分(UES)及两者联合在校正乳腺影像报告和数据系统分级(BI-RADS) 4类乳腺肿块BI-RADS分级中的应用价值。方法 收集我院经常规超声诊断为BI-RADS 4类的乳腺肿块患者109例,共113个肿块。经ABVS及UES校正BI-RADS分级后,与病理结果对比,绘制ROC曲线,比较常规超声、ABVS、UES、ABVS联合UES诊断BI-RADS 4类乳腺肿块的差异。结果 109例患者113个肿块中包含良性78个,恶性35个,ABVS联合UES校正后的敏感度、特异性、准确性、ROC曲线下面积分别为94.29%、93.59%、93.80%、0.975。结论 ABVS联合UES有助于提高BI-RADS 4类肿块的总体诊断效能。两者联合诊断可以取长补短,提高诊断率。 展开更多
关键词 乳腺自动容积成像 超声弹性评分 常规超声 乳腺影像报告和数据系统分级 乳腺肿块
下载PDF
超声新技术辅助诊断BI-RADS 4类病变的应用进展
11
作者 李嘉泓 林鹏基 +4 位作者 吴天祺 薛明松 陈庭威 梁伟翔 刘韬 《中国介入影像与治疗学》 北大核心 2024年第1期52-55,共4页
乳腺影像-报告和数据系统(BI-RADS)4类良、恶性病变的常规超声表现存在一定重叠,易致不必要的穿刺或延误治疗;准确判断乳腺病变性质可为临床决策提供可靠参考。本文围绕应用自动乳腺全容积扫描、超微血管成像、超声弹性成像、超声造影... 乳腺影像-报告和数据系统(BI-RADS)4类良、恶性病变的常规超声表现存在一定重叠,易致不必要的穿刺或延误治疗;准确判断乳腺病变性质可为临床决策提供可靠参考。本文围绕应用自动乳腺全容积扫描、超微血管成像、超声弹性成像、超声造影及人工智能等超声新技术辅助诊断BI-RADS 4类病变的研究进展进行综述。 展开更多
关键词 乳腺肿瘤 超声检查 乳腺影像报告和数据系统
下载PDF
Sonazoid超声造影在BI-RADS 4类乳腺结节诊疗中的应用价值研究
12
作者 王瑞琦 马晓娟 段鹤立 《中国医学装备》 2024年第5期74-78,共5页
目的:探讨Sonazoid超声造影定性与定量分析在诊断乳腺影像报告和数据系统(BI-RADS)4类乳腺病变中的临床应用价值。方法:收集2022年4月至2023年4月于成都市第一人民医院行穿刺活检或手术的乳腺病变患者53例(53个病灶均为BI-RADS4类)。根... 目的:探讨Sonazoid超声造影定性与定量分析在诊断乳腺影像报告和数据系统(BI-RADS)4类乳腺病变中的临床应用价值。方法:收集2022年4月至2023年4月于成都市第一人民医院行穿刺活检或手术的乳腺病变患者53例(53个病灶均为BI-RADS4类)。根据乳腺结节病理结果将患者分为良性组(34例)和恶性组(19例)。所有患者在穿刺活检或者手术前均已行Sonazoid超声造影(CEUS)检查,比较良性组和恶性组乳腺结节造影定性与定量指标之间的差异,选取具有统计学差异的指标纳入回归方程,分别绘制受试者工作特征(ROC)曲线,获得ROC曲线下面积(AUC)。使用Sonoliver软件将造影时乳腺结节与周围正常组织的增强强度差异编码成直观的彩色图像,生成动态血管模型(DVP)参数图,分析在乳腺良、恶性结节中图像颜色的差异。结果:乳腺结节的Sonazoid超声造影定性指标观察中,恶性组乳腺结节多表现为增强范围扩大[13例(占68.4%)],不均匀增强[14例(占73.7%)],周围有穿支血流[12例(占63.2%)],与良性组比较差异均有统计学意义(x^(2)=10.268、9.642、5.717,P<0.05);乳腺结节的Sonazoid超声造影定量指标观察中,恶性组乳腺结节造影的上升时间(RT)、平均渡越时间(m TT)时长小于良性组,差异有统计学意义(Z=-1.985、-2.272,P<0.05)。将上述指标纳入多因素分析,分别建立定性、定量指标预测恶性结节的回归方程,定性、定量分析的ROC曲线下面积分别为0.723、0.902,定性分析结果优于定量分析,差异有统计学意义(Z=-1.965,P<0.05)。在DVP参数图像中,良性组34例结节中有23例(占67.6%)结节表现为病灶,感兴趣区域(ROI)内大部分呈较单调的红、黄色填充;恶性组19例中有15例(占78.9%)结节的ROI内呈紊乱不规则分散或团块状的斑片状红黄色填充。结论:Sonazoid超声造影能够鉴别乳腺BI-RADS 4类结节的良恶性,定性指标的诊断效能优于定量指标。 展开更多
关键词 乳腺病变 示卓安(Sonazoid)造影剂 超声造影(CEUS) 乳腺影像报告和数据系统(bi-rads)4类
下载PDF
基于超声BI-RADS分类对不同病理类型乳房肿块诊断的结果分析
13
作者 赵云峰 高风丽 《世界复合医学》 2024年第2期85-88,共4页
目的分析基于超声乳腺影像报告和数据系统(Breast Imaging Reporting and Data System,BI-RADS)分类对不同病理类型乳腺肿块诊断的结果。方法方便选取2022年3月—2023年8月在枣庄市台儿庄区人民医院和济南市平阴县中医医院进行检查的74... 目的分析基于超声乳腺影像报告和数据系统(Breast Imaging Reporting and Data System,BI-RADS)分类对不同病理类型乳腺肿块诊断的结果。方法方便选取2022年3月—2023年8月在枣庄市台儿庄区人民医院和济南市平阴县中医医院进行检查的74例女性患者为研究对象。以病理检查为金标准,经病理证实乳腺肿块共80个,采用kappa检验分析超声检查与病理结果的一致性。结果病理结果显示,良性肿块61个,恶性肿块19个(kappa值为0.710,P<0.01)。超声BI-RADS分类诊断的灵敏度、特异度、准确度分别为96.72%、84.21%、93.75%。超声BI-RADS对良性肿瘤的诊断符合率均≥85.71%,而对恶性肿瘤诊断中,符合率最低时为75.00%。结论虽然不同病理类型乳腺肿块的超声诊断符合率较高,但在实际操作过程中仍然存在漏诊误诊等情况,故需要临床医师了解超声检查的不足,对超声诊断质量做好把控。 展开更多
关键词 超声检查 超声乳腺影像报告和数据系统分类 病理类型 乳腺肿块 诊断结果
下载PDF
超声人工智能辅助诊断系统在最大径≤2 cm的BI-RADS 4类乳腺结节诊断中的应用价值
14
作者 陈蕊 吴墅 +2 位作者 郭佳 郭芳琪 赵佳琦 《海军军医大学学报》 CAS CSCD 北大核心 2024年第5期592-598,共7页
目的探讨超声人工智能(AI)辅助诊断系统对最大径≤2 cm的乳腺影像报告与数据系统(BI-RADS)4类乳腺结节的诊断价值。方法回顾性分析2020年5月至2022年10月于上海中医药大学附属曙光医院进行超声检查并诊断为BI-RADS 4类乳腺结节的204例... 目的探讨超声人工智能(AI)辅助诊断系统对最大径≤2 cm的乳腺影像报告与数据系统(BI-RADS)4类乳腺结节的诊断价值。方法回顾性分析2020年5月至2022年10月于上海中医药大学附属曙光医院进行超声检查并诊断为BI-RADS 4类乳腺结节的204例患者共210个最大径≤2 cm结节的二维超声图像。以术后病理结果为金标准,评价常规超声和AI系统(风险评分值阈值设为0.65、0.70)对最大径≤2 cm的BI-RADS 4类乳腺结节良恶性的诊断效能。结果210个乳腺结节中良性结节94个,恶性结节116个。高年资超声医师常规超声检查诊断乳腺结节良恶性的灵敏度为92.24%,特异度为75.53%,准确度为84.76%;AI系统(阈值0.65)诊断乳腺结节良恶性的灵敏度为92.24%,特异度为71.28%,准确度为82.86%;AI系统(阈值0.70)诊断乳腺结节良恶性的灵敏度为90.52%,特异度为79.79%,准确度为85.71%。AI系统(阈值0.70)诊断BI-RADS 4a类结节的准确度高于常规超声和AI系统(阈值0.65)(79.41%vs 77.94%、75.00%)。高年资超声医师通过常规超声对最大径≤1 cm的结节诊断准确度最高,为86.36%,AI系统(阈值0.65)及AI系统(阈值0.70)准确度分别为81.82%、84.09%。结论超声AI辅助诊断系统可辅助鉴别诊断最大径≤2 cm的BI-RADS 4类乳腺结节的良恶性。 展开更多
关键词 超声检查 人工智能 计算机辅助诊断系统 乳腺肿瘤 乳腺影像报告与数据系统
下载PDF
超微血流成像技术鉴别BI-RADS 4类乳腺微小结节良恶性诊断价值
15
作者 邹慧娴 朱容娟 黎海芳 《影像技术》 CAS 2024年第4期75-80,共6页
目的:探究乳腺影像报告和数据系统(BI-RADS)4类乳腺微小结节应用超微血流成像(SMI)技术良恶性鉴别诊断价值。方法:选取2023年5月至2023年10月在深河人民医院收治的患者60例,这些患者术前均经彩色多普勒超声诊断为BI-RADS 4类乳腺微小结... 目的:探究乳腺影像报告和数据系统(BI-RADS)4类乳腺微小结节应用超微血流成像(SMI)技术良恶性鉴别诊断价值。方法:选取2023年5月至2023年10月在深河人民医院收治的患者60例,这些患者术前均经彩色多普勒超声诊断为BI-RADS 4类乳腺微小结节,所有患者均在本院进行SMI检查,以病理活检结果作为金标准,评估彩色多普勒超声与SMI技术在辅助诊断乳腺微小结节良恶性方面的价值,特别是对血流情况的评估,分析两种方法对乳腺微小结节良恶性诊断价值。结果:根据病理结果将患者分为良性组36例和恶性组24例。经SMI技术对BI-RADS 4类乳腺微小结节进行分级调整,其中良性病例有24例因血流较少而降至3类,3例因血流丰富而提高至5类;恶性病例有1例因血流较少而降至3类,16例因血流丰富而提高至5类;超声及SMI技术检测良、恶性病灶组间血流级别分布差异比较,从统计学角度分析,差异具有统计学意义(P<0.05);彩色多普勒超声法检测60例患者中有36.67%(良性6例、恶性16例)为血流丰富者,而SMI法中有63.33%(良性19例、恶性19例)为血流丰富者,相比较明显增多,从统计学角度分析,差异具有统计学意义(χ^(2)=8.533,P=0.003);彩色多普勒技术鉴别乳腺微小结节良恶性的敏感度为75.00%,特异度为83.33%。而SMI的敏感度为83.33%,特异度为91.67%,从统计学角度分析,差异具有统计学意义(P<0.05)。结论:BI-RADS 4类乳腺微小结节应用SMI技术良恶性鉴别诊断价值较高,值得临床应用。 展开更多
关键词 乳腺影像报告和数据系统 乳腺微小结节 超微血流成像技术 良恶性 鉴别诊断
下载PDF
高频彩色多普勒超声联合BI-RADS分级在临床鉴别诊断良恶性乳腺结节中的应用价值
16
作者 张秀丽 《中外医学研究》 2024年第11期58-61,共4页
目的:探讨高频彩色多普勒超声联合乳腺成像报告和数据系统(BI-RADS)分级在临床鉴别诊断良恶性乳腺结节中的应用价值。方法:选择2022年1月—2023年6月漳州市第二医院收治的197例乳腺结节患者作为研究对象。所有患者均完成高频彩色多普勒... 目的:探讨高频彩色多普勒超声联合乳腺成像报告和数据系统(BI-RADS)分级在临床鉴别诊断良恶性乳腺结节中的应用价值。方法:选择2022年1月—2023年6月漳州市第二医院收治的197例乳腺结节患者作为研究对象。所有患者均完成高频彩色多普勒超声检查,以BI-RADS分级标准进行分级,将病理学检查作为金标准,分析高频彩色多普勒超声联合BI-RADS分级对恶性乳腺结节的诊断效能。结果:病理学检查结果显示,在197例乳腺结节患者中,有58例为恶性结节,139例为良性结节;高频彩色多普勒超声联合BI-RADS分级诊断恶性乳腺结节的敏感度为93.10%(54/58),特异度为61.87%(86/139),准确度为71.07%(140/197),阳性预测值为50.47%(54/107),阴性预测值为95.56%(86/90)。恶性乳腺结节血管收缩期最大流速(Vsmax)、血管舒张期最低流速(Vdmin)高于良性乳腺结节,差异有统计学意义(P<0.05);恶性乳腺结节的结节血供丰富、结节内部回声低占比高于良性乳腺结节,结节形态规则、结节边界清晰占比低于良性乳腺结节,差异有统计学意义(P<0.05)。结论:高频彩色多普勒超声联合BI-RADS分级在临床鉴别诊断良恶性乳腺结节中的应用价值较高。 展开更多
关键词 乳腺结节 高频彩色多普勒超声 乳腺成像报告和数据系统分级
下载PDF
乳腺癌患者病理类型与超声BI-RADS分级、声像图表现的关系分析
17
作者 刘亚君 《实用癌症杂志》 2024年第8期1353-1355,共3页
目的分析乳腺癌患者超声乳腺影像报告和数据系统(BI-RADS)分级、声像图表现与病理类型的关系。方法回顾性分析87例乳腺包块患者(87个包块)的有关资料,所有患者均行超声检查,并行BI-RADS分级,穿刺活检或术后病理检查证实包块性质,统计分... 目的分析乳腺癌患者超声乳腺影像报告和数据系统(BI-RADS)分级、声像图表现与病理类型的关系。方法回顾性分析87例乳腺包块患者(87个包块)的有关资料,所有患者均行超声检查,并行BI-RADS分级,穿刺活检或术后病理检查证实包块性质,统计分析超声诊断与病理检查结果。结果超声BI-RADS分级显示,87例包块患者中,共检出49例恶性病变(4a级、4b级、4c级、5级),38例良性病变(3级)。病理检查结果显示,87例乳腺包块患者共检出87个包块,其中恶性病变共50例,主要包括浸润性导管癌31例,导管原位癌12例,浸润性微乳头状癌7例;良性病变共37例,主要包括乳腺增生结节23例,纤维腺瘤12例,其他2例。以病理检查为“金标准”,超声BI-RADS分级检查的灵敏度为96.00%(48/50)、特异度为97.30%(36/37)、准确度为96.55%(84/87);kappa检验显示:超声BI-RADS分级检查结果与病理检查结果的一致性极好(kappa值=0.930,P=0.000);恶性病变直径≥2 cm、钙化、边界不清、纵横比≥1、后方回声逐渐衰减、血流(PSV>20 cm/s,RI>0.70)的占比均高于良性病变,差异有统计学意义(P<0.05)。结论超声BI-RADS分级与声像图表现结合应用,可提高乳腺包块的定性诊断,精准地判定乳腺包块的良恶性,进而提高乳腺癌的检出准确性,为临床提供可靠的依据。 展开更多
关键词 乳腺癌 病理分型 乳腺影像报告和数据系统 声像图表现
下载PDF
数字乳腺体层合成技术对超声诊断为BI-RADS 3、4类乳腺病变的应用价值
18
作者 黎绮玲 黄泽鑫 《影像研究与医学应用》 2024年第5期22-25,共4页
目的:探讨数字乳腺体层合成(DBT)联合二维图像(SM)对超声诊断为乳腺影像报告与数据系统(BI-RADS)3、4类女性乳腺病变的应用价值。方法:回顾性分析2023年3月—10月深圳市福田区妇幼保健院超声诊断为BI-RADS3、4类的100例女性患者,全部均... 目的:探讨数字乳腺体层合成(DBT)联合二维图像(SM)对超声诊断为乳腺影像报告与数据系统(BI-RADS)3、4类女性乳腺病变的应用价值。方法:回顾性分析2023年3月—10月深圳市福田区妇幼保健院超声诊断为BI-RADS3、4类的100例女性患者,全部均进行全数字化乳腺X线摄影(FFDM)和DBT,并合成SM,对FFDM、DBT+SM两种图像进行分析,由2位医师分别记录不同类型乳腺病变的检出情况,病变的影像学征象及BI-RADS分类结果。结果:FFDM与DBT+SM两种图像的BI-RADS分类差异有统计学意义(P<0.05)。FFDM与DBT+SM两种图像对肿块型病灶检出率差异具有统计学意义(P <0.05)。DBT+SM检查诊断BI-RADS 3、4类乳腺病变准确率、灵敏度、特异度均高于FFDM检查。DBT+SM对结构扭曲病灶检出的数量多。对于钙化型病灶、非对称致密病灶、相关征象检出率及对肿块边缘、钙化形态的显示,两种图像差异无统计学意义(P> 0.05)。结论:DBT+SM较FFDM在超声诊断为BI-RADS3、4类女性乳腺病变中具有较高的诊断价值,特别是在显示肿块型病变、结构扭曲方面具备优势。 展开更多
关键词 数字乳腺体层合成 超声 女性 乳腺影像报告与数据系统
下载PDF
超声乳腺影像与BI-RADS分级在女性乳腺癌筛查中的应用价值体会
19
作者 冒琴 《智慧健康》 2024年第6期12-15,共4页
目的 探讨超声乳腺影像及BI-RADS分级在女性乳腺癌筛查中的应用价值。方法 从在2022年5月—2022年9月年龄在35~64岁在本院进行乳腺筛查的2656例女性患者中,选取乳腺肿块BI-RADS评分Ⅲ-Ⅴ级的80例超声图像进行分析。其中,BI-RADS分类Ⅳa... 目的 探讨超声乳腺影像及BI-RADS分级在女性乳腺癌筛查中的应用价值。方法 从在2022年5月—2022年9月年龄在35~64岁在本院进行乳腺筛查的2656例女性患者中,选取乳腺肿块BI-RADS评分Ⅲ-Ⅴ级的80例超声图像进行分析。其中,BI-RADS分类Ⅳa级及以上的病例共10例。BI-RADS分类Ⅳa级及以上的病例均经过穿刺活检或直接手术切除进行最终诊断。结果 在80例乳腺肿块病例中,共诊断出乳腺癌5例和乳腺纤维瘤5例。其中,BI-RADS分类Ⅲ级病例中,恶性肿块占10%。而在BI-RADS分类Ⅳa级及以上的病例中,恶性肿块占50%。结论 通过本研究,我们发现超声乳腺影像报告及BI-RADS分级在判断乳腺肿块的良恶性中具有较高的应用价值。在评估乳腺肿块时,BI-RADS分类能够较为准确地区分恶性肿块和良性肿块。此外,超声影像报告提供了肿块形态、回声特征等详细信息,有助于医生进行进一步的诊断判断。在筛查乳腺癌并提供早期干预方面,超声乳腺影像报告和BI-RADS分级为医生提供了重要的参考依据。 展开更多
关键词 超声乳腺影像报告 bi-rads分级 女性乳腺癌 筛查
下载PDF
Effect of training on resident inter-reader agreement with American College of Radiology Thyroid Imaging Reporting and Data System
20
作者 Yang Du Meredith Bara +6 位作者 Prayash Katlariwala Roger Croutze Katrin Resch Jonathan Porter Medica Sam Mitchell P Wilson Gavin Low 《World Journal of Radiology》 2022年第1期19-29,共11页
BACKGROUND The American College of Radiology Thyroid Imaging Reporting and Data System(ACR TI-RADS)was introduced to standardize the ultrasound characterization of thyroid nodules.Studies have shown that ACR-TIRADS re... BACKGROUND The American College of Radiology Thyroid Imaging Reporting and Data System(ACR TI-RADS)was introduced to standardize the ultrasound characterization of thyroid nodules.Studies have shown that ACR-TIRADS reduces unnecessary biopsies and improves consistency of imaging recommendations.Despite its widespread adoption,there are few studies to date assessing the inter-reader agreement amongst radiology trainees with limited ultrasound experience.We hypothesize that in PGY-4 radiology residents with no prior exposure to ACR TIRADS,a statistically significant improvement in inter-reader reliability can be achieved with a one hour training session.AIM To evaluate the inter-reader agreement of radiology residents in using ACR TIRADS before and after training.METHODS A single center retrospective cohort study evaluating 50 thyroid nodules in 40 patients of varying TI-RADS levels was performed.Reference standard TI-RADS scores were established through a consensus panel of three fellowship-trained staff radiologists with between 1 and 14 years of clinical experience each.Three PGY-4 radiology residents(trainees)were selected as blinded readers for this study.Each trainee had between 4 to 5 mo of designated ultrasound training.No trainee had received specialized TI-RADS training prior to this study.Each of the readers independently reviewed the 50 testing cases and assigned a TI-RADS score to each case before and after TI-RADS training performed 6 wk apart.Fleiss kappa was used to measure the pooled inter-reader agreement.The relative diagnostic performance of readers,pre-and post-training,when compared against the reference standard.RESULTS There were 33 females and 7 males with a mean age of 56.6±13.6 years.The mean nodule size was 19±14 mm(range from 5 to 63 mm).A statistically significant superior inter-reader agreement was found on the post-training assessment compared to the pre-training assessment for the following variables:1.“Shape”(k of 0.09[slight]pre-training vs 0.67[substantial]post-training,P<0.001),2.“Echogenic foci”(k of 0.28[fair]pre-training vs 0.45[moderate]post-training,P=0.004),3.‘TI-RADS level’(k of 0.14[slight]pre-training vs 0.36[fair]post-training,P<0.001)and 4.‘Recommendations’(k of 0.36[fair]pre-training vs 0.50[moderate]post-training,P=0.02).No significant differences between the preand post-training assessments were found for the variables'composition','echogenicity'and'margins'.There was a general trend towards improved pooled sensitivity with TI-RADS levels 1 to 4 for the post-training assessment while the pooled specificity was relatively high(76.6%-96.8%)for all TI-RADS level.CONCLUSION Statistically significant improvement in inter-reader agreement in the assigning TI-RADS level and recommendations after training is observed.Our study supports the use of dedicated ACR TI-RADS training in radiology residents. 展开更多
关键词 Thyroid Thyroid nodule American College of Radiology Thyroid imaging reporting and data System Inter-reader agreement ultrasound
下载PDF
上一页 1 2 25 下一页 到第
使用帮助 返回顶部