BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guide...BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guided coaxial core needle biopsy(CNB)not only procures sufficient tissue to help clarify the diagnosis,but reduces the incidence of puncture-related complications.CASE SUMMARY A 41-year-old female,with a history of pulmonary tuberculosis,was admitted to our hospital with multiple indeterminate splenic lesions.Gray-scale ultrasono-graphy demonstrated splenomegaly with numerous well-defined hypoechoic ma-sses.Abdominal contrast-enhanced computed tomography(CT)showed an en-larged spleen with multiple irregular-shaped,peripherally enhancing,hypodense lesions.Positron emission CT revealed numerous abnormal hyperglycemia foci.These imaging findings strongly indicated the possibility of infectious disease as the primary concern,with neoplastic lesions requiring exclusion.To obtain the precise pathological diagnosis,the US-guided coaxial CNB of the spleen was ca-rried out.The patient did not express any discomfort during the procedure.CONCLUSION Percutaneous US-guided coaxial CNB is an excellent and safe option for obtaining precise splenic tissue samples,as it significantly enhances sample yield for exact pathological analysis with minimum trauma to the spleen parenchyma and sur-rounding tissue.展开更多
AIM: To evaluate the diagnostic accuracy of histological evaluation of pancreatic tissue samples obtained by a modified method for recovering and processing the endoscopic ultrasound (EUS)-guided fine needle aspira...AIM: To evaluate the diagnostic accuracy of histological evaluation of pancreatic tissue samples obtained by a modified method for recovering and processing the endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) material in the differential diagnosis of pancreatic solid masses. METHODS: Sixty-two consecutive patients with pancreatic masses were prospectively studied. EUS was performed by the linear scanning Pentax FG-38UX echoendoscope. Three FNAs (22G needle) were carried out during each procedure. The materials obtained with first and second punctures were processed for cytological study. Haterials of the third puncture were recovered into 10% formol solution by careful injection of saline solution through the needle, and processed for histological study. RESULTS: Length of the core specimen obtained for histological analysis was 6.5±5.3 mm (range 1-22 mm). Cytological and histological samples were considered as adequate in 51 (82.3%) and 52 cases (83.9%), respectively. Overall sensitivity of both pancreatic cytology and histology for diagnosis of malignancy was 68.4%. Conbary to cytology, histology was able to diagnose tumours other than adenocarcinomas, and all cases of inflammatory masses. Combination of cytology and histology allowed obtaining an adequate sample in 56 cases (90.3%), with a global sensitivity of 84.21%, specificity of 100% and an overall accuracy of 90.32%. The complication rate was 1.6%.CONCLUSION: Adequate pancreatic core specimens for histological examination can be obtained by EUS-guided FNA. This technique is mainly useful for the diagnosis of different types of pancreatic tumours and evaluation of benign diseases.展开更多
Fine needle aspiration (FNA) is currently the standard of care for sampling pancreatic solid masses by using endoscopic ultrasound (EUS).The accuracy of the technique is reported to be high,especially if coupled with ...Fine needle aspiration (FNA) is currently the standard of care for sampling pancreatic solid masses by using endoscopic ultrasound (EUS).The accuracy of the technique is reported to be high,especially if coupled with the rapid on site evaluation (ROSE),and it has a high safety profile.However,FNA presents some limitations,such as the small amount of tissue that can be collected and the inability of obtaining a core tissue with intact histological architecture,which is relevant to perform immunohistochemical analysis,molecular profiling and,therefore,targeted therapies.Moreover,the presence of the ROSE by an expert cytopathologist is very important to maximize the diagnostic yield of FNA technique;however,it is not widely available,especially in small centers.Hence,the introduction of EUS fine needle biopsy (FNB) with a new generation of needles,which show a high safety profile too and a satisfying diagnostic accuracy even in the absence of ROSE,could be the key to overcome the limitations of FNA.However,FNB has not yet shown diagnostic superiority over FNA.Considering all the technical aspects of FNA and FNB,the different types of needle currently available,comparisons in term of diagnostic yield,and the different techniques of sampling,a tailored approach should be used in order to determine the needle that is most appropriate for the different specific scenarios.展开更多
Objective:To evaluate the efficacy and safety of percutaneous core needle biopsy(PCNB)using ultrasound(US)-guided and contrast-enhanced ultrasound(CEUS)-guided procedures for anterior mediastinal masses(AMMs).Methods:...Objective:To evaluate the efficacy and safety of percutaneous core needle biopsy(PCNB)using ultrasound(US)-guided and contrast-enhanced ultrasound(CEUS)-guided procedures for anterior mediastinal masses(AMMs).Methods:In total,284 consecutive patients(166 men,118 women;mean age,43.0±18.4 years)who underwent PCNB for AMMs were enrolled.Patients were divided into the US-guided group(n=133)and the CEUS-guided group(n=151).PCNB was performed using a core needle(16-gauge or 18-gauge).Internal necrosis,diagnostic yield,and diagnostic accuracy were compared between the two groups.Results:The predominant final diagnosis of the cases in this study was thymoma(29.7%),lymphoma(20.5%),thymic carcinoma(13.3%),and germ cell tumour(13.3%),respectively.There was no significant difference in patient age,sex,number of percutaneous biopsies,or display rate of internal necrosis on conventional US between the two groups.The rate of internal necrosis of the lesions was significantly higher after contrast agent injection(72.2%vs.41.7%;P<0.001).The CEUS-guided group had a higher diagnostic yield than the US-guided group(100%vs.89.5%,P<0.001).There was no significant difference between the diagnostic accuracy of the CEUSguided and US-guided groups(97.3%vs.97.4%;P=1.000).None of the patients experienced adverse reactions or complications after US-guided or CEUS-guided PCNB.Conclusions:CEUS-guided PCNB can improve the diagnostic yield by optimizing the biopsy procedure.展开更多
BACKGROUND Establishing a diagnosis of pancreatic cystic lesions(PCLs)preoperatively still remains challenging.Recently,endoscopic ultrasound(EUS)-through-the-needle biopsy(EUS-TTNB)using microforceps in PCLs has been...BACKGROUND Establishing a diagnosis of pancreatic cystic lesions(PCLs)preoperatively still remains challenging.Recently,endoscopic ultrasound(EUS)-through-the-needle biopsy(EUS-TTNB)using microforceps in PCLs has been made available.AIM To assess the efficacy and safety of EUS-TTNB in the diagnosis of PCLs.METHODS We retrospectively collected data of patients with PCLs who underwent both EUS-fine-needle aspiration(FNA)for cytology and EUS-TTNB at our institution since 2016.EUS-FNA for cytology was followed by EUS-TTNB in the same session.Evaluation of the cyst location,primary diagnosis,adverse events,and comparison between the cytologic fluid analyses and histopathology was performed.Technical success of EUS-TTNB was defined as visible tissue present after biopsy.Clinical success was defined as the presence of a specimen adequate to make a histologic or cytologic diagnosis.RESULTS A total of 56 patients(mean age 66.9±11.7,53.6%females)with PCLs were enrolled over the study period.The mean cyst size was 28.8 mm(12-85 mm).The EUS-TTNB procedure was technically successful in all patients(100%).The clinical success rate using EUS-TTNB was much higher than standard EUS-FNA,respectively 80.4%(45/56)vs 25%(14/56).Adverse events occurred in 2 patients(3.6%)who developed mild pancreatitis that resolved with medical therapy.Using TTNB specimens,23 of 32 cases(71.9%)with intraductal papillary mucinous neoplasm were further differentiated into gastric type(19 patients)and pancreaticobiliary type(4 patients)based on immunochemical staining.CONCLUSION EUS-TTNB for PCLs was technically feasible and had a favorable safety profile.Furthermore,the diagnostic yield for PCLs was much higher with EUS-TTNB than standard EUS-FNA cytology and fluid carcinoembryonic antigen.EUSTTNB should be considered as an adjunct to EUS-FNA and cytologic analysis in the diagnosis and management of PCLs.展开更多
Endoscopic ultrasound tissue acquisition,in the form of both fine needle aspiration(EUS-FNA)and fine needle biopsy(EUS-FNB),is utilized for pancreatic mass lesions,subepithelial lesions,and lymph node biopsy.Both proc...Endoscopic ultrasound tissue acquisition,in the form of both fine needle aspiration(EUS-FNA)and fine needle biopsy(EUS-FNB),is utilized for pancreatic mass lesions,subepithelial lesions,and lymph node biopsy.Both procedures are safe and yield high diagnostic value.Despite its high diagnostic yield,EUS-FNA has potential limitations associated with cytological aspirations,including inability to determine histologic architecture,and a small quantitative sample for further immunohistochemical staining.EUS-FNB,with its larger core biopsy needle,was designed to overcome these potential limitations.However,it remains unclear which technique should be used and for which lesions.Comparative trials are plagued by heterogeneity at every stage of comparison;including variable needles used,and different definitions of endpoints,which therefore limit generalizability.Thus,we present a review of prospective trials,systematic reviews,and meta-analyses on studies examining EUS-FNA vs EUSFNB.Prospective comparative trials of EUS-FNA vs EUS-FNB primarily focus on pancreatic mass lesions,and yield conflicting results in terms of demonstrating the superiority of one method.However,consistent among trials is the potential for diagnosis with fewer passes,and a larger quantity of sample achieved for next generation sequencing.With regard to subepithelial lesions and lymph node biopsy,fewer prospective trials exist,and larger prospective studies are necessary.Based on the available literature,we would recommend EUS-FNB for peri-hepatic lymph nodes.展开更多
BACKGROUND While endoscopic ultrasound(EUS)-guided fine needle aspiration(FNA)is considered a preferred technique for tissue sampling for solid lesions,fine needle biopsy(FNB)has recently been developed.AIM To compare...BACKGROUND While endoscopic ultrasound(EUS)-guided fine needle aspiration(FNA)is considered a preferred technique for tissue sampling for solid lesions,fine needle biopsy(FNB)has recently been developed.AIM To compare the accuracy of FNB vs FNA in determining the diagnosis of solid lesions.METHODS A retrospective,multi-center study of EUS-guided tissue sampling using FNA vs FNB needles.Measured outcomes included diagnostic test characteristics(i.e.,sensitivity,specificity,accuracy),use of rapid on-site evaluation(ROSE),and adverse events.Subgroup analyses were performed by type of lesion and diagnostic yield with or without ROSE.A multivariable logistic regression was also performed.RESULTS A total of 1168 patients with solid lesions(n=468 FNA;n=700 FNB)underwent EUS-guided sampling.Mean age was 65.02±12.13 years.Overall,sensitivity,specificity and accuracy were superior for FNB vs FNA(84.70%vs 74.53%;99.29%vs 96.62%;and 87.62%vs 81.55%,respectively;P<0.001).On subgroup analyses,sensitivity,specificity,and accuracy of FNB alone were similar to FNA+ROSE[(81.66%vs 86.45%;P=0.142),(100%vs 100%;P=1.00)and(88.40%vs 85.43%;P=0.320].There were no difference in diagnostic yield of FNB alone vs FNB+ROSE(P>0.05).Multivariate analysis showed no significant predictor for better accuracy.On subgroup analyses,FNB was superior to FNA for non-pancreatic lesions;however,there was no difference between the techniques among pancreatic lesions.One adverse event was reported in each group.CONCLUSION FNB is superior to FNA with equivalent diagnostic test characteristics compared to FNA+ROSE in the diagnosis of non-pancreatic solid lesions.Our results suggest that EUS-FNB may eliminate the need of ROSE and should be employed as a first-line method in the diagnosis of solid lesions.展开更多
BACKGROUND Endoscopic ultrasound-guided fine needle biopsy(EUS-FNB)has emerged as a safe,efficacious alternative to fine needle aspiration(FNA)for tissue acquisition.EUS-FNB is reported to have higher diagnostic yield...BACKGROUND Endoscopic ultrasound-guided fine needle biopsy(EUS-FNB)has emerged as a safe,efficacious alternative to fine needle aspiration(FNA)for tissue acquisition.EUS-FNB is reported to have higher diagnostic yield while preserving specimen tissue architecture.However,data on the optimal method of EUS-FNB specimen processing is limited.AIM To evaluate EUS-FNB with specimen processing as histology vs EUS-FNA cytology with regards to diagnostic yield and specimen adequacy.METHODS All EUS-FNA and EUS-FNB performed at our institution from July 1,2016,to January 31,2018,were retrospectively analyzed.We collected data on demographics,EUS findings,pathology,clinical outcomes,and procedural complications in two periods,July 2016 through March 2017,and April 2017 through January 2018,with predominant use of FNB in the second data collection time period.FNA specimens were processed as cytology with cell block technique and reviewed by a cytopathologist;FNB specimens were fixed in formalin,processed for histopathologic analysis and immunohistochemical staining,and reviewed by an anatomic pathologist.Final diagnosis was based on surgical pathology when available,repeat biopsy or imaging,and length of clinical follow up.RESULTS One hundred six EUS-FNA and EUS-FNB procedures were performed.FNA alone was performed in 17 patients;in 56 patients,FNB alone was done;and in 33 patients,both FNA and FNB were performed.For all indications,diagnostic yield was 47.1%(8/17)in FNA alone cases,85.7%(48/56)in FNB alone cases,and 84.8%(28/33)in cases where both FNA and FNB were performed(P=0.0039).Specimens were adequate for pathologic evaluation in 52.9%(9/17)of FNA alone cases,in 89.3%(50/56)of FNB alone cases,and 84.8%(28/33)in cases where FNA with FNB were performed(P=0.0049).Tissue could not be aspirated for cytology in 10.0%(5/50)of cases where FNA was done,while in 3.4%(3/89)of FNB cases,tissue could not be obtained for histology.In patients who underwent FNA with FNB,there was a statistically significant difference in both specimen adequacy(P=0.0455)and diagnostic yield(P=0.0455)between the FNA and FNB specimens(processed correspondingly as cytology or histology).CONCLUSION EUS-FNB has a higher diagnostic yield and specimen adequacy than EUS-FNA.In our experience,specimen processing as histology may have contributed to the overall increased diagnostic yield of EUS-FNB.展开更多
Endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNA) is a useful procedure that enables reliable pathological diagnoses of pancreatobiliary diseases, subepithelial lesions, and swollen lymph nodes. In ...Endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNA) is a useful procedure that enables reliable pathological diagnoses of pancreatobiliary diseases, subepithelial lesions, and swollen lymph nodes. In recent years, a pathological diagnosis based on EUS-FNA has made it possible to provide accurate treatment methods not only in these fields, but also in respiratory organs and otorhinolaryngology. This review discusses the latest topics pertaining to EUS-FNA as well as procedural tips.展开更多
Objective:To explore the significance of ultrasound and ultrasound-guided coarse needle biopsy in the clinical diagnosis of breast cancer patients in pregnancy.Methods:A total of 10 patients with breast cancer in preg...Objective:To explore the significance of ultrasound and ultrasound-guided coarse needle biopsy in the clinical diagnosis of breast cancer patients in pregnancy.Methods:A total of 10 patients with breast cancer in pregnancy were selected to study from October 2018 to October 2019 in our hospital,who were given preoperative ultrasound results and ultrasound-guided coarse-needle biopsy histopathology,and the results were analyzed.Results:All the 10 patients showed thickening of the mammary gland body,appeared to pick up disorderly situation,most of the dilated catheter,including 8 patients with solid hypoechoic mass,irregular shape,and“crab foot”edge burr.The corresponding aspect ratio value was greater than 1.The other 2 patients presented with cystic mixed masses with poor boundary definition,irregular shape,and mostly accompanied by posterior echo enhancement.Conclusion:Simple ultrasound diagnosis for patients with breast cancer during pregnancy has some errors,and should be used in combination with ultrasound-guided coarse needle biopsy operation.This method has a high clinical diagnosis rate and significant clinical application value,so it is worth promoting.展开更多
BACKGROUND Rectal subepithelial lesions(SELs) are commonly seen in endoscopic examination, generally manifested as bumps with a smooth surface. Precise preoperative diagnoses for rectal SELs are difficult because abno...BACKGROUND Rectal subepithelial lesions(SELs) are commonly seen in endoscopic examination, generally manifested as bumps with a smooth surface. Precise preoperative diagnoses for rectal SELs are difficult because abnormal tissues are not easily to be obtained by regular endoscopic forceps biopsy. Traditional guidance modalities of preoperative biopsy, including endoscopic ultrasound, computed tomography, and transabdominal ultrasound, are often unsatisfactory. An updated, safe, and effective biopsy guidance method is required. We herein report a new biopsy guidance modality—endorectal ultrasound(ERUS) combined with contrastenhanced ultrasound(CEUS).CASE SUMMARY A 32-year-old woman complained of a mass inside the rectovaginal space for 9 years, which became enlarged within 1 year. A rectal SEL detected by endoscopy was suspected to be a gastrointestinal stromal tumor or exophytic uterine fibroid. Pathological diagnosis was difficult because of unsuccessful transabdominal core needle biopsy with insufficient tissues, as well as vaginal hemorrhage. A second biopsy was suggested after multiple disciplinary treatment discussion, which referred to a transperineal core needle biopsy(CNB) guided by ERUS combined with CEUS. Adequate samples were procured and rectal gastrointestinal stromal tumor was proved to be the pathological diagnosis. Imatinib was recommended for first-line therapy by multiple disciplinary treatment discussion. After the tumor shrunk, resection of the rectal gastrointestinal stromal tumor was performed through the posterior vaginal wall. Adjuvant therapy was applied and no recurrence or metastasis has been found by the last follow-up on December 13, 2019.CONCLUSION Transperineal CNB guided by ERUS and CEUS is a safe and effective preoperative biopsy of rectal SELs yet with some limitations.展开更多
Background: Core needle biopsy (CNB) under ultrasound guidance is an accepted standard of care for the diagnosis of breast lesions. It is safe, cost-effective and minimally invasive compared with surgical excision. Ob...Background: Core needle biopsy (CNB) under ultrasound guidance is an accepted standard of care for the diagnosis of breast lesions. It is safe, cost-effective and minimally invasive compared with surgical excision. Objective: The aim of this study was to evaluate the CNB’s results regarding the procedure, complications, histopathological findings and their correlation with the imaging data and surgical histopathological findings. Method: A cross-sectional prospective and descriptive study of a consecutive series of ultrasound-guided CNB of breast lesions in women conduced from January 2015 to December 2016 at the Sylvanus Olympio university hospital of Lomé, in Togo. Results: There were 72 CNB performed under ultrasound guidance in women;from which 54 were retained for the study. The mean age was 44.9 years ± 9.8. 11.1% had a family history of breast cancer. Lesions were most often palpable (90.7%). They were located in the left breast in 54.7%. Lesions were categorized probably malignant or malignant (Birads 4 and 5) in 70.4% and probably benign (Birads 3) in 29.6%. Their mean size was 24.8 mm ± 7.6 at ultrasound. There were no major complications during the procedure. One CNB (1.9%) considered inconclusive was repeated. Histologically, invasive ductal carcinoma (61.1%) was the most common lesion. Fifty-three women underwent surgical procedure and histopathological confirmation. Ultrasound-guided CNB had a sensitivity of 97.5%, specificity of 100%, positive predictive value of 100%, negative predictive value of 92.8%, and an overall diagnostic accuracy of 98.1%. Breast Imaging Reporting and Data System (Birads) categorization had a sensitivity of 94.8%, specificity of 100%, positive predictive value of 100%, negative predictive value of 87.4%, and diagnostic accuracy of 96.2%. Conclusion: Ultrasound guided CNB represent accurate methods for the characterization of breast lesions, with high values of diagnostic accuracy, sensitivity, specificity and negative predictive value. It does not involve a major complication, even in tropical environments.展开更多
Since its initial report in 1992,endoscopic ultrasoundguided fine needle aspiration(EUS-FNA) has now been incorporated into the diagnostic and staging algorithm for the evaluation of benign and malignant diseases of t...Since its initial report in 1992,endoscopic ultrasoundguided fine needle aspiration(EUS-FNA) has now been incorporated into the diagnostic and staging algorithm for the evaluation of benign and malignant diseases of the gastrointestinal tract and of adjacent organs.Its introduction constitutes a major breakthrough in the endoscopic field and has gradually transformed EUS from a pure imaging modality into a more interventional procedure.In addition,the possibility of collecting samples,providing a definitive cytological and/or histological evidence of the presence of malignancy,has strongly contributed to changing EUS from a subjective,highly operator dependant procedure into a more objective one.This article will review the instrumentation,technique and the most important clinical applications of EUS-FNA.展开更多
AIM To compare the aspiration needle(AN) and core biopsy needle(PC) in endoscopic ultrasound-guided fine needle aspiration(EUS-FNA) of abdominal masses.METHODS Consecutive patients referred for EUS-FNA were included i...AIM To compare the aspiration needle(AN) and core biopsy needle(PC) in endoscopic ultrasound-guided fine needle aspiration(EUS-FNA) of abdominal masses.METHODS Consecutive patients referred for EUS-FNA were included in this prospective single-center trial. Each patient underwent a puncture of the lesion with both standard 22-gauge(G) AN(Echo Tip Ultra; Cook Medical, Bloomington, Indiana, United States) and the novel 22 G PC(Echo Tip Pro Core; Cook Medical, Bloomington, Indiana, United States) in a randomized fashion; histology was attempted in the PC group only. The main study endpoint was the overall diagnostic accuracy, including the contribution of histology to the final diagnosis. Secondary outcome measures included material adequacy, number of needle passes, and complications.RESULTS Fifty six consecutive patients(29 men; mean age 68 years) with pancreatic lesions(n = 38), lymphadenopathy(n = 13), submucosal tumors(n = 4), or others lesions(n = 1) underwent EUS-FNA using both of the needles in a randomized order. AN and PC reached similar overall results for diagnostic accuracy(AN: 88.9 vs PC: 96.1, P = 0.25), specimen adequacy(AN: 96.4% vs PC: 91.1%, P = 0.38), mean number of passes(AN: 1.5 vs PC: 1.7, P = 0.14), mean cellularity score(AN: 1.7 vs PC: 1.1, P = 0.058), and complications(none). A diagnosis on the basis of histology was achieved in the PC group in 36(64.3%) patients, and in 2 of those as the sole modality. In patients with available histology the mean cellularity score was higher for AN(AN: 1.7 vs PC: 1.0, P = 0.034); no other differences were of statistical significance.CONCLUSION Both needles achieved high overall diagnostic yields and similar performance characteristics for cytological diagnosis; histological analysis was only possible in 2/3 of cases with the new needle.展开更多
Since its introduction,endoscopic ultrasound(EUS)guided fine needle aspiration and fine needle biopsy have become an indispensable tool for the diagnosis of lesions within the gastrointestinal tract and surrounding or...Since its introduction,endoscopic ultrasound(EUS)guided fine needle aspiration and fine needle biopsy have become an indispensable tool for the diagnosis of lesions within the gastrointestinal tract and surrounding organs.It has proved to be an effective diagnostic method with high accuracy and low complication rates.Several factors can influence the accuracy and the diagnostic yield of this procedure including experience of the endosonographer,availability of onsite cytopathology services,the method of cytopathology preparation,the location and physical characteristics of the lesion,sampling techniques and the type and size of the needle used.In this review we will outline the recent studies evaluating EUS-guided tissue acquisition and will provide practical recommendations to maximize tissue yield.展开更多
BACKGROUND Reverse bevel(RB)needle is widely used for endoscopic ultrasound fine needle biopsy(EUS-FNB).A 3-plane symmetrical needle with Franseen geometry(FG)has recently become available.AIM To compare the clinical ...BACKGROUND Reverse bevel(RB)needle is widely used for endoscopic ultrasound fine needle biopsy(EUS-FNB).A 3-plane symmetrical needle with Franseen geometry(FG)has recently become available.AIM To compare the clinical efficacy of FG to that of RB needle.METHODS A retrospective cohort study of all adult patients who underwent EUS-FNB for solid and mixed lesions either with 22G RB needle or 22G FG needle between January 2016 and February 2019 was undertaken.All cytology slides were reviewed by an independent gastrointestinal cytopathologist blinded to the needle used and the initial cytology report.The primary and secondary outcomes were to assess the sample adequacy using Euro-cytology criteria and the number of cell clusters,respectively.RESULTS Two hundred and twenty six procedures were included in the study.RB needle was used in 128 procedures and FG needle in 98 procedures.The baseline characteristics of both groups were comparable.On multivariable analysis,FG needle(P=0.02)and location of the lesion(P<0.01)were independently associated with adequate tissue.Further,the use of FG needle(P=0.04)and the size of the lesion(P=0.02)were independently associated with acquisition of increased number of cell clusters.CONCLUSION FG needle is superior to RB needle in acquiring adequate tissue and attaining higher number of cell clusters for solid and mixed lesions.展开更多
AIM To compare the accuracy of endoscopic ultra-sonography(EUS) 19 G core biopsies and 22 G core biopsies in diagnosing the correct etiology for a solid mass.METHODS Articles were searched in Medline, Pub Med, and Ovi...AIM To compare the accuracy of endoscopic ultra-sonography(EUS) 19 G core biopsies and 22 G core biopsies in diagnosing the correct etiology for a solid mass.METHODS Articles were searched in Medline, Pub Med, and Ovid journals. Pooling was conducted by both fixed and random effects models. RESULTS Initial search identified 4460 reference articles for 19 G and 22 G, of these 670 relevant articles were selected and reviewed. Data was extracted from 6 studies for 19G(n = 289) and 16 studies for 22G(n = 592) which met the inclusion criteria. EUS 19 G core biopsies had a pooled sensitivity of 91.6%(95%CI: 87.1-95.0) and pooled specificity of 95.9%(95%CI: 88.6-99.2), whereas EUS 22 G had a pooled sensitivity of 83.3%(95%CI: 79.7-86.6) and pooled specificity of 64.3%(95%CI: 54.7-73.1). The positive likelihood ratio of EUS 19 G core biopsies was 9.08(95%CI: 1.12-73.66) and EUS 22 G core biopsies was 1.99(95%CI: 1.09-3.66).The negative likelihood ratio of EUS 19 G core biopsies was 0.12(95%CI: 0.07-0.24) and EUS 22 G core biopsies was 0.25(95%CI: 0.14-0.41). The diagnostic odds ratio was 84.74(95%CI: 18.31-392.26) for 19 G core biopsies and 10.55(95% CI: 3.29-33.87) for 22 G needles. CONCLUSION EUS 19 G core biopsies have an excellent diagnostic value and seem to be better than EUS 22 G biopsies in detecting the correct etiology for a solid mass.展开更多
Backgrounds:Percutaneous ultrasound(US)and endoscopic ultrasound(EUS)-guided pancreatic biopsies are widely accepted in the diagnosis of pancreatic diseases.Studies comparing the diagnostic performance of US-and EUS-g...Backgrounds:Percutaneous ultrasound(US)and endoscopic ultrasound(EUS)-guided pancreatic biopsies are widely accepted in the diagnosis of pancreatic diseases.Studies comparing the diagnostic performance of US-and EUS-guided pancreatic biopsies are lacking.This study aimed to evaluate and compare the diagnostic yields of US-and EUS-guided pancreatic biopsies and identify the risk factors for inconclusive biopsies.Methods:Of the 1074 solid pancreatic lesions diagnosed from January 2017 to February 2021 in our center,275 underwent EUS-guided fine needle aspiration(EUS-FNA),and 799 underwent US-guided core needle biopsy(US-CNB/FNA).The outcomes were inconclusive pathological biopsy,diagnostic accuracy and the need for repeat biopsy.All of the included factors and diagnostic performances of both USCNB/FNA and EUS-FNA were compared,and the independent predictors for the study outcomes were identified.Results:The diagnostic accuracy was 89.8%for EUS-FNA and 95.2%for US-CNB/FNA(P=0.001).Biopsy under EUS guidance[odds ratio(OR)=1.808,95%confidence interval(CI):1.083-3.019;P=0.024],lesion size<2 cm(OR=2.069,95%CI:1.145-3.737;P=0.016),hypoechoic appearance(OR=0.274,95%CI:0.097-0.775;P=0.015)and non-pancreatic ductal adenocarcinoma carcinoma(PDAC)diagnosis(OR=2.637,95%CI:1.563-4.449;P<0.001)were identified as factors associated with inconclusive pathological biopsy.Hypoechoic appearance(OR=0.236,95%CI:0.064-0.869;P=0.030),lesions in the uncinate process of the pancreas(OR=3.506,95%CI:1.831-6.713;P<0.001)and non-PDAC diagnosis(OR=2.622,95%CI:1.278-5.377;P=0.009)were independent predictors for repeat biopsy.Biopsy under EUS guidance(OR=2.024,95%CI:1.195-3.429;P=0.009),lesions in the uncinate process of the pancreas(OR=1.776,95%CI:1.014-3.108;P=0.044)and hypoechoic appearance(OR=0.127,95%CI:0.047-0.347;P<0.001)were associated with diagnostic accuracy.Conclusions:In conclusion,both percutaneous US-and EUS-guided biopsies of solid pancreatic lesions are safe and effective;though the diagnostic accuracy of EUS-FNA is inferior to US-CNB/FNA.A tailored pancreatic biopsy should be considered a part of the management algorithm for the diagnosis of solid pancreatic disease.展开更多
BACKGROUND Endoscopic ultrasound-guided fine needle aspiration or biopsy(EUS-FNA or FNB)has become a popular method for diagnosing various lesions of the gastrointestinal tract and surrounding tissue due to the accura...BACKGROUND Endoscopic ultrasound-guided fine needle aspiration or biopsy(EUS-FNA or FNB)has become a popular method for diagnosing various lesions of the gastrointestinal tract and surrounding tissue due to the accuracy and safety.To the best of our knowledge,no case report of severe infection after EUS-FNB of a solid lesion in the spleen has been described.Herein,we report a rare case of septic shock after EUS-FNB of a splenic mass.CASE SUMMARY A 45-year-old male patient presented to the outpatient clinic due to an incidentally detected splenic mass.A definitive diagnosis could not be established based on the abdominal magnetic resonance imaging.EUS of the spleen showed a 6 cm-sized,relatively well-demarcated,heterogeneous mass,and EUS-FNB with a 22G needle was performed.Ten days after the procedure patient developed septic shock and a splenic abscess was identified.Blood culture revealed growth of Granulicatella adiacens.After the treatment with antibiotics the patient underwent surgical resection,and the pathological examination showed diffuse large B-cell lymphoma.The patient received chemotherapy and he is in complete remission.CONCLUSION Infection of a splenic mass after EUS-FNB is a rare complication and prophylactic antibiotics might be considered.展开更多
Liver biopsy(LB)is an essential tool in diagnosing,evaluating and managing various diseases of the liver.As such,histopathological results are critical as they establish or aid in diagnosis,provide information on prog...Liver biopsy(LB)is an essential tool in diagnosing,evaluating and managing various diseases of the liver.As such,histopathological results are critical as they establish or aid in diagnosis,provide information on prognosis,and guide the appropriate selection of medical therapy for patients.Indications for LB include evaluation of persistent elevation of liver chemistries of unclear etiology,diagnosis of chronic liver diseases such as Wilson's disease,autoimmune hepatitis,small duct primary sclerosing cholangitis,work up of fever of unknown origin,amyloidosis and more.Traditionally,methods of acquiring liver tissue have included percutaneous LB(PCLB),transjugular LB(TJLB)or biopsy taken surgically via laparotomy or laparoscopy.However,traditional methods of LB may be inferior to newer methods.Additionally,PCLB and TJLB carry higher risks of adverse events and complications.More recently,endoscopic ultrasound guided LB(EUS-LB)has evolved as an alternative method of tissue sampling that has proven to be safe and effective,with limited adverse events.Compared to PC and TJ routes,EUS-LB may also have a greater diagnostic yield of tissue,be superior for a targeted approach of focal lesions,provide higher quality images and allow for greater patient comfort.These advantages have contributed to the increased use of EUS-LB as a technique for obtaining liver tissue.Herein,we provide a review of the recent evidence of EUS-LB for liver disease.展开更多
文摘BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guided coaxial core needle biopsy(CNB)not only procures sufficient tissue to help clarify the diagnosis,but reduces the incidence of puncture-related complications.CASE SUMMARY A 41-year-old female,with a history of pulmonary tuberculosis,was admitted to our hospital with multiple indeterminate splenic lesions.Gray-scale ultrasono-graphy demonstrated splenomegaly with numerous well-defined hypoechoic ma-sses.Abdominal contrast-enhanced computed tomography(CT)showed an en-larged spleen with multiple irregular-shaped,peripherally enhancing,hypodense lesions.Positron emission CT revealed numerous abnormal hyperglycemia foci.These imaging findings strongly indicated the possibility of infectious disease as the primary concern,with neoplastic lesions requiring exclusion.To obtain the precise pathological diagnosis,the US-guided coaxial CNB of the spleen was ca-rried out.The patient did not express any discomfort during the procedure.CONCLUSION Percutaneous US-guided coaxial CNB is an excellent and safe option for obtaining precise splenic tissue samples,as it significantly enhances sample yield for exact pathological analysis with minimum trauma to the spleen parenchyma and sur-rounding tissue.
文摘AIM: To evaluate the diagnostic accuracy of histological evaluation of pancreatic tissue samples obtained by a modified method for recovering and processing the endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) material in the differential diagnosis of pancreatic solid masses. METHODS: Sixty-two consecutive patients with pancreatic masses were prospectively studied. EUS was performed by the linear scanning Pentax FG-38UX echoendoscope. Three FNAs (22G needle) were carried out during each procedure. The materials obtained with first and second punctures were processed for cytological study. Haterials of the third puncture were recovered into 10% formol solution by careful injection of saline solution through the needle, and processed for histological study. RESULTS: Length of the core specimen obtained for histological analysis was 6.5±5.3 mm (range 1-22 mm). Cytological and histological samples were considered as adequate in 51 (82.3%) and 52 cases (83.9%), respectively. Overall sensitivity of both pancreatic cytology and histology for diagnosis of malignancy was 68.4%. Conbary to cytology, histology was able to diagnose tumours other than adenocarcinomas, and all cases of inflammatory masses. Combination of cytology and histology allowed obtaining an adequate sample in 56 cases (90.3%), with a global sensitivity of 84.21%, specificity of 100% and an overall accuracy of 90.32%. The complication rate was 1.6%.CONCLUSION: Adequate pancreatic core specimens for histological examination can be obtained by EUS-guided FNA. This technique is mainly useful for the diagnosis of different types of pancreatic tumours and evaluation of benign diseases.
文摘Fine needle aspiration (FNA) is currently the standard of care for sampling pancreatic solid masses by using endoscopic ultrasound (EUS).The accuracy of the technique is reported to be high,especially if coupled with the rapid on site evaluation (ROSE),and it has a high safety profile.However,FNA presents some limitations,such as the small amount of tissue that can be collected and the inability of obtaining a core tissue with intact histological architecture,which is relevant to perform immunohistochemical analysis,molecular profiling and,therefore,targeted therapies.Moreover,the presence of the ROSE by an expert cytopathologist is very important to maximize the diagnostic yield of FNA technique;however,it is not widely available,especially in small centers.Hence,the introduction of EUS fine needle biopsy (FNB) with a new generation of needles,which show a high safety profile too and a satisfying diagnostic accuracy even in the absence of ROSE,could be the key to overcome the limitations of FNA.However,FNB has not yet shown diagnostic superiority over FNA.Considering all the technical aspects of FNA and FNB,the different types of needle currently available,comparisons in term of diagnostic yield,and the different techniques of sampling,a tailored approach should be used in order to determine the needle that is most appropriate for the different specific scenarios.
基金supported by the Natural Scienceof Shanghai“Science and Technology Innovation Action Plan”(Grant No.20ZR1452800)Clinical Research Plan of SHDC(Grant No.SHDC2020CR1031B)Shanghai Municipal Key Clinical Specialty of China(Grant No.shslczdzk03501)。
文摘Objective:To evaluate the efficacy and safety of percutaneous core needle biopsy(PCNB)using ultrasound(US)-guided and contrast-enhanced ultrasound(CEUS)-guided procedures for anterior mediastinal masses(AMMs).Methods:In total,284 consecutive patients(166 men,118 women;mean age,43.0±18.4 years)who underwent PCNB for AMMs were enrolled.Patients were divided into the US-guided group(n=133)and the CEUS-guided group(n=151).PCNB was performed using a core needle(16-gauge or 18-gauge).Internal necrosis,diagnostic yield,and diagnostic accuracy were compared between the two groups.Results:The predominant final diagnosis of the cases in this study was thymoma(29.7%),lymphoma(20.5%),thymic carcinoma(13.3%),and germ cell tumour(13.3%),respectively.There was no significant difference in patient age,sex,number of percutaneous biopsies,or display rate of internal necrosis on conventional US between the two groups.The rate of internal necrosis of the lesions was significantly higher after contrast agent injection(72.2%vs.41.7%;P<0.001).The CEUS-guided group had a higher diagnostic yield than the US-guided group(100%vs.89.5%,P<0.001).There was no significant difference between the diagnostic accuracy of the CEUSguided and US-guided groups(97.3%vs.97.4%;P=1.000).None of the patients experienced adverse reactions or complications after US-guided or CEUS-guided PCNB.Conclusions:CEUS-guided PCNB can improve the diagnostic yield by optimizing the biopsy procedure.
文摘BACKGROUND Establishing a diagnosis of pancreatic cystic lesions(PCLs)preoperatively still remains challenging.Recently,endoscopic ultrasound(EUS)-through-the-needle biopsy(EUS-TTNB)using microforceps in PCLs has been made available.AIM To assess the efficacy and safety of EUS-TTNB in the diagnosis of PCLs.METHODS We retrospectively collected data of patients with PCLs who underwent both EUS-fine-needle aspiration(FNA)for cytology and EUS-TTNB at our institution since 2016.EUS-FNA for cytology was followed by EUS-TTNB in the same session.Evaluation of the cyst location,primary diagnosis,adverse events,and comparison between the cytologic fluid analyses and histopathology was performed.Technical success of EUS-TTNB was defined as visible tissue present after biopsy.Clinical success was defined as the presence of a specimen adequate to make a histologic or cytologic diagnosis.RESULTS A total of 56 patients(mean age 66.9±11.7,53.6%females)with PCLs were enrolled over the study period.The mean cyst size was 28.8 mm(12-85 mm).The EUS-TTNB procedure was technically successful in all patients(100%).The clinical success rate using EUS-TTNB was much higher than standard EUS-FNA,respectively 80.4%(45/56)vs 25%(14/56).Adverse events occurred in 2 patients(3.6%)who developed mild pancreatitis that resolved with medical therapy.Using TTNB specimens,23 of 32 cases(71.9%)with intraductal papillary mucinous neoplasm were further differentiated into gastric type(19 patients)and pancreaticobiliary type(4 patients)based on immunochemical staining.CONCLUSION EUS-TTNB for PCLs was technically feasible and had a favorable safety profile.Furthermore,the diagnostic yield for PCLs was much higher with EUS-TTNB than standard EUS-FNA cytology and fluid carcinoembryonic antigen.EUSTTNB should be considered as an adjunct to EUS-FNA and cytologic analysis in the diagnosis and management of PCLs.
文摘Endoscopic ultrasound tissue acquisition,in the form of both fine needle aspiration(EUS-FNA)and fine needle biopsy(EUS-FNB),is utilized for pancreatic mass lesions,subepithelial lesions,and lymph node biopsy.Both procedures are safe and yield high diagnostic value.Despite its high diagnostic yield,EUS-FNA has potential limitations associated with cytological aspirations,including inability to determine histologic architecture,and a small quantitative sample for further immunohistochemical staining.EUS-FNB,with its larger core biopsy needle,was designed to overcome these potential limitations.However,it remains unclear which technique should be used and for which lesions.Comparative trials are plagued by heterogeneity at every stage of comparison;including variable needles used,and different definitions of endpoints,which therefore limit generalizability.Thus,we present a review of prospective trials,systematic reviews,and meta-analyses on studies examining EUS-FNA vs EUSFNB.Prospective comparative trials of EUS-FNA vs EUS-FNB primarily focus on pancreatic mass lesions,and yield conflicting results in terms of demonstrating the superiority of one method.However,consistent among trials is the potential for diagnosis with fewer passes,and a larger quantity of sample achieved for next generation sequencing.With regard to subepithelial lesions and lymph node biopsy,fewer prospective trials exist,and larger prospective studies are necessary.Based on the available literature,we would recommend EUS-FNB for peri-hepatic lymph nodes.
基金the Research Ethics Committee from Partners Human Research(Protocol No.2003P001665).
文摘BACKGROUND While endoscopic ultrasound(EUS)-guided fine needle aspiration(FNA)is considered a preferred technique for tissue sampling for solid lesions,fine needle biopsy(FNB)has recently been developed.AIM To compare the accuracy of FNB vs FNA in determining the diagnosis of solid lesions.METHODS A retrospective,multi-center study of EUS-guided tissue sampling using FNA vs FNB needles.Measured outcomes included diagnostic test characteristics(i.e.,sensitivity,specificity,accuracy),use of rapid on-site evaluation(ROSE),and adverse events.Subgroup analyses were performed by type of lesion and diagnostic yield with or without ROSE.A multivariable logistic regression was also performed.RESULTS A total of 1168 patients with solid lesions(n=468 FNA;n=700 FNB)underwent EUS-guided sampling.Mean age was 65.02±12.13 years.Overall,sensitivity,specificity and accuracy were superior for FNB vs FNA(84.70%vs 74.53%;99.29%vs 96.62%;and 87.62%vs 81.55%,respectively;P<0.001).On subgroup analyses,sensitivity,specificity,and accuracy of FNB alone were similar to FNA+ROSE[(81.66%vs 86.45%;P=0.142),(100%vs 100%;P=1.00)and(88.40%vs 85.43%;P=0.320].There were no difference in diagnostic yield of FNB alone vs FNB+ROSE(P>0.05).Multivariate analysis showed no significant predictor for better accuracy.On subgroup analyses,FNB was superior to FNA for non-pancreatic lesions;however,there was no difference between the techniques among pancreatic lesions.One adverse event was reported in each group.CONCLUSION FNB is superior to FNA with equivalent diagnostic test characteristics compared to FNA+ROSE in the diagnosis of non-pancreatic solid lesions.Our results suggest that EUS-FNB may eliminate the need of ROSE and should be employed as a first-line method in the diagnosis of solid lesions.
基金Supported by the National Center for Advancing Translational Sciences through University of California,Los Angeles Clinical and Translational Science Institute Grant,No.UL1TR001881-01.
文摘BACKGROUND Endoscopic ultrasound-guided fine needle biopsy(EUS-FNB)has emerged as a safe,efficacious alternative to fine needle aspiration(FNA)for tissue acquisition.EUS-FNB is reported to have higher diagnostic yield while preserving specimen tissue architecture.However,data on the optimal method of EUS-FNB specimen processing is limited.AIM To evaluate EUS-FNB with specimen processing as histology vs EUS-FNA cytology with regards to diagnostic yield and specimen adequacy.METHODS All EUS-FNA and EUS-FNB performed at our institution from July 1,2016,to January 31,2018,were retrospectively analyzed.We collected data on demographics,EUS findings,pathology,clinical outcomes,and procedural complications in two periods,July 2016 through March 2017,and April 2017 through January 2018,with predominant use of FNB in the second data collection time period.FNA specimens were processed as cytology with cell block technique and reviewed by a cytopathologist;FNB specimens were fixed in formalin,processed for histopathologic analysis and immunohistochemical staining,and reviewed by an anatomic pathologist.Final diagnosis was based on surgical pathology when available,repeat biopsy or imaging,and length of clinical follow up.RESULTS One hundred six EUS-FNA and EUS-FNB procedures were performed.FNA alone was performed in 17 patients;in 56 patients,FNB alone was done;and in 33 patients,both FNA and FNB were performed.For all indications,diagnostic yield was 47.1%(8/17)in FNA alone cases,85.7%(48/56)in FNB alone cases,and 84.8%(28/33)in cases where both FNA and FNB were performed(P=0.0039).Specimens were adequate for pathologic evaluation in 52.9%(9/17)of FNA alone cases,in 89.3%(50/56)of FNB alone cases,and 84.8%(28/33)in cases where FNA with FNB were performed(P=0.0049).Tissue could not be aspirated for cytology in 10.0%(5/50)of cases where FNA was done,while in 3.4%(3/89)of FNB cases,tissue could not be obtained for histology.In patients who underwent FNA with FNB,there was a statistically significant difference in both specimen adequacy(P=0.0455)and diagnostic yield(P=0.0455)between the FNA and FNB specimens(processed correspondingly as cytology or histology).CONCLUSION EUS-FNB has a higher diagnostic yield and specimen adequacy than EUS-FNA.In our experience,specimen processing as histology may have contributed to the overall increased diagnostic yield of EUS-FNB.
文摘Endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNA) is a useful procedure that enables reliable pathological diagnoses of pancreatobiliary diseases, subepithelial lesions, and swollen lymph nodes. In recent years, a pathological diagnosis based on EUS-FNA has made it possible to provide accurate treatment methods not only in these fields, but also in respiratory organs and otorhinolaryngology. This review discusses the latest topics pertaining to EUS-FNA as well as procedural tips.
文摘Objective:To explore the significance of ultrasound and ultrasound-guided coarse needle biopsy in the clinical diagnosis of breast cancer patients in pregnancy.Methods:A total of 10 patients with breast cancer in pregnancy were selected to study from October 2018 to October 2019 in our hospital,who were given preoperative ultrasound results and ultrasound-guided coarse-needle biopsy histopathology,and the results were analyzed.Results:All the 10 patients showed thickening of the mammary gland body,appeared to pick up disorderly situation,most of the dilated catheter,including 8 patients with solid hypoechoic mass,irregular shape,and“crab foot”edge burr.The corresponding aspect ratio value was greater than 1.The other 2 patients presented with cystic mixed masses with poor boundary definition,irregular shape,and mostly accompanied by posterior echo enhancement.Conclusion:Simple ultrasound diagnosis for patients with breast cancer during pregnancy has some errors,and should be used in combination with ultrasound-guided coarse needle biopsy operation.This method has a high clinical diagnosis rate and significant clinical application value,so it is worth promoting.
基金Supported by National Natural Science Foundation of China,No. 81101061Sichuan Science and Technology Planning Project,China,No. 2017JY0074。
文摘BACKGROUND Rectal subepithelial lesions(SELs) are commonly seen in endoscopic examination, generally manifested as bumps with a smooth surface. Precise preoperative diagnoses for rectal SELs are difficult because abnormal tissues are not easily to be obtained by regular endoscopic forceps biopsy. Traditional guidance modalities of preoperative biopsy, including endoscopic ultrasound, computed tomography, and transabdominal ultrasound, are often unsatisfactory. An updated, safe, and effective biopsy guidance method is required. We herein report a new biopsy guidance modality—endorectal ultrasound(ERUS) combined with contrastenhanced ultrasound(CEUS).CASE SUMMARY A 32-year-old woman complained of a mass inside the rectovaginal space for 9 years, which became enlarged within 1 year. A rectal SEL detected by endoscopy was suspected to be a gastrointestinal stromal tumor or exophytic uterine fibroid. Pathological diagnosis was difficult because of unsuccessful transabdominal core needle biopsy with insufficient tissues, as well as vaginal hemorrhage. A second biopsy was suggested after multiple disciplinary treatment discussion, which referred to a transperineal core needle biopsy(CNB) guided by ERUS combined with CEUS. Adequate samples were procured and rectal gastrointestinal stromal tumor was proved to be the pathological diagnosis. Imatinib was recommended for first-line therapy by multiple disciplinary treatment discussion. After the tumor shrunk, resection of the rectal gastrointestinal stromal tumor was performed through the posterior vaginal wall. Adjuvant therapy was applied and no recurrence or metastasis has been found by the last follow-up on December 13, 2019.CONCLUSION Transperineal CNB guided by ERUS and CEUS is a safe and effective preoperative biopsy of rectal SELs yet with some limitations.
文摘Background: Core needle biopsy (CNB) under ultrasound guidance is an accepted standard of care for the diagnosis of breast lesions. It is safe, cost-effective and minimally invasive compared with surgical excision. Objective: The aim of this study was to evaluate the CNB’s results regarding the procedure, complications, histopathological findings and their correlation with the imaging data and surgical histopathological findings. Method: A cross-sectional prospective and descriptive study of a consecutive series of ultrasound-guided CNB of breast lesions in women conduced from January 2015 to December 2016 at the Sylvanus Olympio university hospital of Lomé, in Togo. Results: There were 72 CNB performed under ultrasound guidance in women;from which 54 were retained for the study. The mean age was 44.9 years ± 9.8. 11.1% had a family history of breast cancer. Lesions were most often palpable (90.7%). They were located in the left breast in 54.7%. Lesions were categorized probably malignant or malignant (Birads 4 and 5) in 70.4% and probably benign (Birads 3) in 29.6%. Their mean size was 24.8 mm ± 7.6 at ultrasound. There were no major complications during the procedure. One CNB (1.9%) considered inconclusive was repeated. Histologically, invasive ductal carcinoma (61.1%) was the most common lesion. Fifty-three women underwent surgical procedure and histopathological confirmation. Ultrasound-guided CNB had a sensitivity of 97.5%, specificity of 100%, positive predictive value of 100%, negative predictive value of 92.8%, and an overall diagnostic accuracy of 98.1%. Breast Imaging Reporting and Data System (Birads) categorization had a sensitivity of 94.8%, specificity of 100%, positive predictive value of 100%, negative predictive value of 87.4%, and diagnostic accuracy of 96.2%. Conclusion: Ultrasound guided CNB represent accurate methods for the characterization of breast lesions, with high values of diagnostic accuracy, sensitivity, specificity and negative predictive value. It does not involve a major complication, even in tropical environments.
文摘Since its initial report in 1992,endoscopic ultrasoundguided fine needle aspiration(EUS-FNA) has now been incorporated into the diagnostic and staging algorithm for the evaluation of benign and malignant diseases of the gastrointestinal tract and of adjacent organs.Its introduction constitutes a major breakthrough in the endoscopic field and has gradually transformed EUS from a pure imaging modality into a more interventional procedure.In addition,the possibility of collecting samples,providing a definitive cytological and/or histological evidence of the presence of malignancy,has strongly contributed to changing EUS from a subjective,highly operator dependant procedure into a more objective one.This article will review the instrumentation,technique and the most important clinical applications of EUS-FNA.
文摘AIM To compare the aspiration needle(AN) and core biopsy needle(PC) in endoscopic ultrasound-guided fine needle aspiration(EUS-FNA) of abdominal masses.METHODS Consecutive patients referred for EUS-FNA were included in this prospective single-center trial. Each patient underwent a puncture of the lesion with both standard 22-gauge(G) AN(Echo Tip Ultra; Cook Medical, Bloomington, Indiana, United States) and the novel 22 G PC(Echo Tip Pro Core; Cook Medical, Bloomington, Indiana, United States) in a randomized fashion; histology was attempted in the PC group only. The main study endpoint was the overall diagnostic accuracy, including the contribution of histology to the final diagnosis. Secondary outcome measures included material adequacy, number of needle passes, and complications.RESULTS Fifty six consecutive patients(29 men; mean age 68 years) with pancreatic lesions(n = 38), lymphadenopathy(n = 13), submucosal tumors(n = 4), or others lesions(n = 1) underwent EUS-FNA using both of the needles in a randomized order. AN and PC reached similar overall results for diagnostic accuracy(AN: 88.9 vs PC: 96.1, P = 0.25), specimen adequacy(AN: 96.4% vs PC: 91.1%, P = 0.38), mean number of passes(AN: 1.5 vs PC: 1.7, P = 0.14), mean cellularity score(AN: 1.7 vs PC: 1.1, P = 0.058), and complications(none). A diagnosis on the basis of histology was achieved in the PC group in 36(64.3%) patients, and in 2 of those as the sole modality. In patients with available histology the mean cellularity score was higher for AN(AN: 1.7 vs PC: 1.0, P = 0.034); no other differences were of statistical significance.CONCLUSION Both needles achieved high overall diagnostic yields and similar performance characteristics for cytological diagnosis; histological analysis was only possible in 2/3 of cases with the new needle.
文摘Since its introduction,endoscopic ultrasound(EUS)guided fine needle aspiration and fine needle biopsy have become an indispensable tool for the diagnosis of lesions within the gastrointestinal tract and surrounding organs.It has proved to be an effective diagnostic method with high accuracy and low complication rates.Several factors can influence the accuracy and the diagnostic yield of this procedure including experience of the endosonographer,availability of onsite cytopathology services,the method of cytopathology preparation,the location and physical characteristics of the lesion,sampling techniques and the type and size of the needle used.In this review we will outline the recent studies evaluating EUS-guided tissue acquisition and will provide practical recommendations to maximize tissue yield.
基金We thank the colleagues of Department of Pathology in Queen’s Medical Centre, Nottingham for their help in specimen slides retrieval.
文摘BACKGROUND Reverse bevel(RB)needle is widely used for endoscopic ultrasound fine needle biopsy(EUS-FNB).A 3-plane symmetrical needle with Franseen geometry(FG)has recently become available.AIM To compare the clinical efficacy of FG to that of RB needle.METHODS A retrospective cohort study of all adult patients who underwent EUS-FNB for solid and mixed lesions either with 22G RB needle or 22G FG needle between January 2016 and February 2019 was undertaken.All cytology slides were reviewed by an independent gastrointestinal cytopathologist blinded to the needle used and the initial cytology report.The primary and secondary outcomes were to assess the sample adequacy using Euro-cytology criteria and the number of cell clusters,respectively.RESULTS Two hundred and twenty six procedures were included in the study.RB needle was used in 128 procedures and FG needle in 98 procedures.The baseline characteristics of both groups were comparable.On multivariable analysis,FG needle(P=0.02)and location of the lesion(P<0.01)were independently associated with adequate tissue.Further,the use of FG needle(P=0.04)and the size of the lesion(P=0.02)were independently associated with acquisition of increased number of cell clusters.CONCLUSION FG needle is superior to RB needle in acquiring adequate tissue and attaining higher number of cell clusters for solid and mixed lesions.
文摘AIM To compare the accuracy of endoscopic ultra-sonography(EUS) 19 G core biopsies and 22 G core biopsies in diagnosing the correct etiology for a solid mass.METHODS Articles were searched in Medline, Pub Med, and Ovid journals. Pooling was conducted by both fixed and random effects models. RESULTS Initial search identified 4460 reference articles for 19 G and 22 G, of these 670 relevant articles were selected and reviewed. Data was extracted from 6 studies for 19G(n = 289) and 16 studies for 22G(n = 592) which met the inclusion criteria. EUS 19 G core biopsies had a pooled sensitivity of 91.6%(95%CI: 87.1-95.0) and pooled specificity of 95.9%(95%CI: 88.6-99.2), whereas EUS 22 G had a pooled sensitivity of 83.3%(95%CI: 79.7-86.6) and pooled specificity of 64.3%(95%CI: 54.7-73.1). The positive likelihood ratio of EUS 19 G core biopsies was 9.08(95%CI: 1.12-73.66) and EUS 22 G core biopsies was 1.99(95%CI: 1.09-3.66).The negative likelihood ratio of EUS 19 G core biopsies was 0.12(95%CI: 0.07-0.24) and EUS 22 G core biopsies was 0.25(95%CI: 0.14-0.41). The diagnostic odds ratio was 84.74(95%CI: 18.31-392.26) for 19 G core biopsies and 10.55(95% CI: 3.29-33.87) for 22 G needles. CONCLUSION EUS 19 G core biopsies have an excellent diagnostic value and seem to be better than EUS 22 G biopsies in detecting the correct etiology for a solid mass.
基金supported by grants from The Development Project of National Major Scientific Research Instrument(82027803)National Natural Science Foundation of China(81971623)Key Project of Natural Science Foundation of Zhejiang Province(LZ20H180001)。
文摘Backgrounds:Percutaneous ultrasound(US)and endoscopic ultrasound(EUS)-guided pancreatic biopsies are widely accepted in the diagnosis of pancreatic diseases.Studies comparing the diagnostic performance of US-and EUS-guided pancreatic biopsies are lacking.This study aimed to evaluate and compare the diagnostic yields of US-and EUS-guided pancreatic biopsies and identify the risk factors for inconclusive biopsies.Methods:Of the 1074 solid pancreatic lesions diagnosed from January 2017 to February 2021 in our center,275 underwent EUS-guided fine needle aspiration(EUS-FNA),and 799 underwent US-guided core needle biopsy(US-CNB/FNA).The outcomes were inconclusive pathological biopsy,diagnostic accuracy and the need for repeat biopsy.All of the included factors and diagnostic performances of both USCNB/FNA and EUS-FNA were compared,and the independent predictors for the study outcomes were identified.Results:The diagnostic accuracy was 89.8%for EUS-FNA and 95.2%for US-CNB/FNA(P=0.001).Biopsy under EUS guidance[odds ratio(OR)=1.808,95%confidence interval(CI):1.083-3.019;P=0.024],lesion size<2 cm(OR=2.069,95%CI:1.145-3.737;P=0.016),hypoechoic appearance(OR=0.274,95%CI:0.097-0.775;P=0.015)and non-pancreatic ductal adenocarcinoma carcinoma(PDAC)diagnosis(OR=2.637,95%CI:1.563-4.449;P<0.001)were identified as factors associated with inconclusive pathological biopsy.Hypoechoic appearance(OR=0.236,95%CI:0.064-0.869;P=0.030),lesions in the uncinate process of the pancreas(OR=3.506,95%CI:1.831-6.713;P<0.001)and non-PDAC diagnosis(OR=2.622,95%CI:1.278-5.377;P=0.009)were independent predictors for repeat biopsy.Biopsy under EUS guidance(OR=2.024,95%CI:1.195-3.429;P=0.009),lesions in the uncinate process of the pancreas(OR=1.776,95%CI:1.014-3.108;P=0.044)and hypoechoic appearance(OR=0.127,95%CI:0.047-0.347;P<0.001)were associated with diagnostic accuracy.Conclusions:In conclusion,both percutaneous US-and EUS-guided biopsies of solid pancreatic lesions are safe and effective;though the diagnostic accuracy of EUS-FNA is inferior to US-CNB/FNA.A tailored pancreatic biopsy should be considered a part of the management algorithm for the diagnosis of solid pancreatic disease.
文摘BACKGROUND Endoscopic ultrasound-guided fine needle aspiration or biopsy(EUS-FNA or FNB)has become a popular method for diagnosing various lesions of the gastrointestinal tract and surrounding tissue due to the accuracy and safety.To the best of our knowledge,no case report of severe infection after EUS-FNB of a solid lesion in the spleen has been described.Herein,we report a rare case of septic shock after EUS-FNB of a splenic mass.CASE SUMMARY A 45-year-old male patient presented to the outpatient clinic due to an incidentally detected splenic mass.A definitive diagnosis could not be established based on the abdominal magnetic resonance imaging.EUS of the spleen showed a 6 cm-sized,relatively well-demarcated,heterogeneous mass,and EUS-FNB with a 22G needle was performed.Ten days after the procedure patient developed septic shock and a splenic abscess was identified.Blood culture revealed growth of Granulicatella adiacens.After the treatment with antibiotics the patient underwent surgical resection,and the pathological examination showed diffuse large B-cell lymphoma.The patient received chemotherapy and he is in complete remission.CONCLUSION Infection of a splenic mass after EUS-FNB is a rare complication and prophylactic antibiotics might be considered.
文摘Liver biopsy(LB)is an essential tool in diagnosing,evaluating and managing various diseases of the liver.As such,histopathological results are critical as they establish or aid in diagnosis,provide information on prognosis,and guide the appropriate selection of medical therapy for patients.Indications for LB include evaluation of persistent elevation of liver chemistries of unclear etiology,diagnosis of chronic liver diseases such as Wilson's disease,autoimmune hepatitis,small duct primary sclerosing cholangitis,work up of fever of unknown origin,amyloidosis and more.Traditionally,methods of acquiring liver tissue have included percutaneous LB(PCLB),transjugular LB(TJLB)or biopsy taken surgically via laparotomy or laparoscopy.However,traditional methods of LB may be inferior to newer methods.Additionally,PCLB and TJLB carry higher risks of adverse events and complications.More recently,endoscopic ultrasound guided LB(EUS-LB)has evolved as an alternative method of tissue sampling that has proven to be safe and effective,with limited adverse events.Compared to PC and TJ routes,EUS-LB may also have a greater diagnostic yield of tissue,be superior for a targeted approach of focal lesions,provide higher quality images and allow for greater patient comfort.These advantages have contributed to the increased use of EUS-LB as a technique for obtaining liver tissue.Herein,we provide a review of the recent evidence of EUS-LB for liver disease.