期刊文献+
共找到60,906篇文章
< 1 2 250 >
每页显示 20 50 100
Seeing beneath the surface:Harnessing point-of-care ultrasound for internal jugular vein evaluation 被引量:1
1
作者 Vichayut Chayapinun Abhilash Koratala Taweevat Assavapokee 《World Journal of Cardiology》 2024年第2期73-79,共7页
Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to... Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to conditions such as liver disease or abdominal surgery.While many clinicians are familiar with visually assessing jugular venous pressure through the internal jugular vein,this method lacks sensitivity.The utilization of POCUS significantly enhances the visualization of the vein,leading to a more accurate identification.It has been demonstrated that combining IJV POCUS with physical examination enhances the specificity of RAP estimation.This review aims to provide a comprehensive summary of the various sonographic techniques available for estimating RAP from the internal jugular vein,drawing upon existing data. 展开更多
关键词 Point-of-care ultrasound Bedside ultrasound Internal jugular vein Right atrial pressure Central venous pressure
下载PDF
Evaluation of hand infections in the emergency department using point-of-care ultrasound
2
作者 David Ahmad Haidar David Mintz +2 位作者 Brandon M Wubben Omar Rizvi Srikar Adhikari 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第4期283-288,共6页
BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient mana... BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient management.METHODS:We conducted a retrospective review of patients who presented to two urban academic EDs with clinical presentations concerning for skin and soft tissue infections(SSTI)of the hand between December 2015 and December 2021.Two trained POCUS fellowship physicians reviewed an ED POCUS database for POCUS examinations of the hand.We then reviewed patients’electronic health records(EHR)for demographic characteristics,history,physical examination findings,ED course,additional imaging studies,consultations,impact of POCUS on patient care and final disposition.RESULTS:We included a total of 50 cases(28 male,22 female)in the final analysis.The most common presenting symptoms and exam findings were pain(100%),swelling(90%),and erythema(74%).The most common sonographic findings were edema(76%),soft tissue swelling(78%),and fluid surrounding the tendon(57%).POCUS was used in medical decision making 68%of the time(n=34),with the use of POCUS leading to changes in management 38%of the time(n=19).POCUS use led to early antibiotic use(11/19),early consultation(10/19),and led to the performance of a required procedure(8/19).The POCUS diagnosis was consistent with the discharge diagnosis of flexor tenosynovitis 8/12 times,abscess 12/16 times,and cellulitis 14/20 times.CONCLUSION:POCUS is beneficial for evaluating of hand infections that present to the ED and can be used as an important part of medical decision making to expedite patient care. 展开更多
关键词 ultrasound Point-of-care ultrasound CELLULITIS ABSCESS Flexor tenosynovitis
下载PDF
Is endoscopic ultrasound a promising technique in the diagnosis and treatment of liver diseases?
3
作者 Enver Zerem Željko Puljiz +3 位作者 Boris Zdilar Suad Kunosic Admir Kurtcehajic Omar Zerem 《World Journal of Gastroenterology》 SCIE CAS 2024年第22期2920-2922,共3页
Percutaneous ultrasound has been a longstanding method in the diagnostics and interventional procedures of liver diseases.In some countries,its use is restricted to radiologists,limiting access for other clinicians,su... Percutaneous ultrasound has been a longstanding method in the diagnostics and interventional procedures of liver diseases.In some countries,its use is restricted to radiologists,limiting access for other clinicians,such as gastroenterologists.Endoscopic ultrasound,as a novel technique,plays a crucial role in diagnosis and treatment of digestive diseases.However,its use is sometimes recommended for conditions where no clear advantage over percutaneous ultrasound exists,leaving the impression that clinicians sometimes resort to an endoscopic approach due to the unavailability of percutaneous options. 展开更多
关键词 Endoscopic ultrasound Percutaneous ultrasound Liver biopsy Fine needle aspiration Focal liver lesion Liver abscess drainage
下载PDF
Dynamic contrast enhanced ultrasound in differential diagnosis of hepatocellular carcinoma: A systematic review and meta-analysis
4
作者 Giorgio Esposto Paolo Santini +5 位作者 Fabrizio Termite Linda Galasso Irene Mignini Maria Elena Ainora Antonio Gasbarrini Maria Assunta Zocco 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第6期2804-2815,共12页
BACKGROUND Non-invasive differential diagnosis between hepatocellular carcinoma(HCC)and other liver cancer(i.e.cholangiocarcinoma or metastasis)is highly challenging and definitive diagnosis still relies on histologic... BACKGROUND Non-invasive differential diagnosis between hepatocellular carcinoma(HCC)and other liver cancer(i.e.cholangiocarcinoma or metastasis)is highly challenging and definitive diagnosis still relies on histological exam.The patterns of enhancement and wash-out of liver nodules can be used to stratify the risk of malignancy only in cirrhotic patients and HCC frequently shows atypical features.Dynamic contrast-enhanced ultrasound(DCEUS)with standardized software could help to overcome these obstacles,providing functional and quantitative parameters and potentially improving accuracy in the evaluation of tumor perfusion.AIM To explore clinical evidence regarding the application of DCEUS in the differential diagnosis of liver nodules.METHODS A comprehensive literature search of clinical studies was performed to identify the parameters of DCEUS that could relate to histological diagnosis.In accordance with the study protocol,a qualitative and quantitative analysis of the evidence was planned.RESULTS Rise time was significantly higher in HCC patients with a standardized mean difference(SMD)of 0.83(95%CI:0.48-1.18).Similarly,other statistically significant parameters were mean transit time local with a SMD of 0.73(95%CI:0.20-1.27),peak enhancement with a SMD of 0.37(95%CI:0.03-0.70),area wash-in area under the curve with a SMD of 0.47(95%CI:0.13-0.81),wash-out area under the curve with a SMD of 0.55(95%CI:0.21-0.89)and wash-in and wash-out area under the curve with SMD of 0.51(95%CI:0.17-0.85).SMD resulted not significant in fall time and wash-in rate,but the latter presented a trend towards greater values in HCC compared to intrahepatic cholangiocarcinoma.CONCLUSION DCEUS could improve non-invasive diagnosis of HCC,leading to less liver biopsy and early treatment.This quantitative analysis needs to be applied on larger cohorts to confirm these preliminary results. 展开更多
关键词 Dynamic contrast enhanced ultrasound Hepatocellular carcinoma Intracellular cholangiocarcinoma Quantitative ultrasound Liver cancer Time-intensity curve
下载PDF
Automatic detection of breast lesions in automated 3D breast ultrasound with cross-organ transfer learning
5
作者 Lingyun BAO Zhengrui HUANG +7 位作者 Zehui LIN Yue SUN Hui CHEN You LI Zhang LI Xiaochen YUAN Lin XU Tao TAN 《虚拟现实与智能硬件(中英文)》 EI 2024年第3期239-251,共13页
Background Deep convolutional neural networks have garnered considerable attention in numerous machine learning applications,particularly in visual recognition tasks such as image and video analyses.There is a growing... Background Deep convolutional neural networks have garnered considerable attention in numerous machine learning applications,particularly in visual recognition tasks such as image and video analyses.There is a growing interest in applying this technology to diverse applications in medical image analysis.Automated three dimensional Breast Ultrasound is a vital tool for detecting breast cancer,and computer-assisted diagnosis software,developed based on deep learning,can effectively assist radiologists in diagnosis.However,the network model is prone to overfitting during training,owing to challenges such as insufficient training data.This study attempts to solve the problem caused by small datasets and improve model detection performance.Methods We propose a breast cancer detection framework based on deep learning(a transfer learning method based on cross-organ cancer detection)and a contrastive learning method based on breast imaging reporting and data systems(BI-RADS).Results When using cross organ transfer learning and BIRADS based contrastive learning,the average sensitivity of the model increased by a maximum of 16.05%.Conclusion Our experiments have demonstrated that the parameters and experiences of cross-organ cancer detection can be mutually referenced,and contrastive learning method based on BI-RADS can improve the detection performance of the model. 展开更多
关键词 Breast ultrasound Automated 3D breast ultrasound Breast cancers Deep learning Transfer learning Convolutional neural networks Computer-aided diagnosis Cross organ learning
下载PDF
Point-of-care ultrasonography spotlight:Could venous excess ultrasound serve as a shared language for internists and intensivists?
6
作者 Anosh Aslam Khan Hasham Saeed +3 位作者 Ibtehaj Ul Haque Ayman Iqbal Doantrang Du Abhilash Koratala 《World Journal of Critical Care Medicine》 2024年第2期126-136,共11页
Point-of-care ultrasonography(POCUS),particularly venous excess ultrasound(VExUS)is emerging as a valuable bedside tool to gain real-time hemodynamic insights.This modality,derived from hepatic vein,portal vein,and in... Point-of-care ultrasonography(POCUS),particularly venous excess ultrasound(VExUS)is emerging as a valuable bedside tool to gain real-time hemodynamic insights.This modality,derived from hepatic vein,portal vein,and intrarenal vessel Doppler patterns,offers a scoring system for dynamic venous congestion assessment.Such an assessment can be crucial in effective management of patients with heart failure exacerbation.It facilitates diagnosis,quantification of congestion,prognostication,and monitoring the efficacy of decongestive therapy.As such,it can effectively help to manage cardiorenal syndromes in various clinical settings.Extended or eVExUS explores additional veins,potentially broadening its applications.While VExUS demonstrates promising outcomes,challenges persist,particularly in cases involving renal and liver parenchymal disease,arrhythmias,and situations of pressure and volume overload overlap.Proficiency in utilizing spectral Doppler is pivotal for clinicians to effectively employ this tool.Hence,the integration of POCUS,especially advanced applications like VExUS,into routine clinical practice necessitates enhanced training across medical specialties. 展开更多
关键词 Point-of-care ultrasonography ultrasound Venous excess ultrasound Doppler Congestion Heart failure
下载PDF
Use of endoscopic ultrasound-guided gallbladder drainage as a rescue approach in cases of unsuccessful biliary drainage
7
作者 Alessandro Fugazza Kareem Khalaf +10 位作者 Katarzyna M Pawlak Marco Spadaccini Matteo Colombo Marta Andreozzi Marco Giacchetto Silvia Carrara Chiara Ferrari Cecilia Binda Benedetto Mangiavillano Andrea Anderloni Alessandro Repici 《World Journal of Gastroenterology》 SCIE CAS 2024年第1期70-78,共9页
This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally ... This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally invasive and effective technique for drainage in patients with acute cholecystitis with high risk of surgery.The procedure has demonstrated impressive technical and clinical success rates with low rates of adverse events,making it a safe and effective option for appropriate candidates.Furthermore,EUS-GBD can also serve as a rescue option for patients who have failed endoscopic retrograde cholangiopancreatography or EUS biliary drainage for relief of jaundice in malignant biliary stricture.However,patient selection is critical for the success of EUS-GBD,and proper patient selection and risk assessment are important to ensure the safety and efficacy of the procedure.As the field continues to evolve and mature,ongoing research will further refine our understanding of the benefits and limitations of EUS-GBD,ultimately leading to improved outcomes for patients. 展开更多
关键词 Endoscopic ultrasound-guided gallbladder drainage Gallbladder drainage Acute cholecystitis Malignant obstruction Interventional endoscopic ultrasound Lumen-apposing metal stents
下载PDF
Percutaneous ultrasound-guided coaxial core needle biopsy for the diagnosis of multiple splenic lesions: A case report
8
作者 Sha-Hong Pu Wu-Yong-Ga Bao +2 位作者 Zhen-Peng Jiang Rui Yang Qiang Lu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第2期616-621,共6页
BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guide... BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guided coaxial core needle biopsy(CNB)not only procures sufficient tissue to help clarify the diagnosis,but reduces the incidence of puncture-related complications.CASE SUMMARY A 41-year-old female,with a history of pulmonary tuberculosis,was admitted to our hospital with multiple indeterminate splenic lesions.Gray-scale ultrasono-graphy demonstrated splenomegaly with numerous well-defined hypoechoic ma-sses.Abdominal contrast-enhanced computed tomography(CT)showed an en-larged spleen with multiple irregular-shaped,peripherally enhancing,hypodense lesions.Positron emission CT revealed numerous abnormal hyperglycemia foci.These imaging findings strongly indicated the possibility of infectious disease as the primary concern,with neoplastic lesions requiring exclusion.To obtain the precise pathological diagnosis,the US-guided coaxial CNB of the spleen was ca-rried out.The patient did not express any discomfort during the procedure.CONCLUSION Percutaneous US-guided coaxial CNB is an excellent and safe option for obtaining precise splenic tissue samples,as it significantly enhances sample yield for exact pathological analysis with minimum trauma to the spleen parenchyma and sur-rounding tissue. 展开更多
关键词 SPLEEN Splenic disease ultrasound BIOPSY ultrasound-guided coaxial core needle biopsy Case report
下载PDF
Multiparametric ultrasound as a new concept of assessment of liver tissue damage
9
作者 Angela Peltec Ioan Sporea 《World Journal of Gastroenterology》 SCIE CAS 2024年第12期1663-1669,共7页
Liver disease accounts for approximately 2 million deaths per year worldwide.All chronic liver diseases(CLDs),whether of toxic,genetic,autoimmune,or infectious origin,undergo typical histological changes in the struct... Liver disease accounts for approximately 2 million deaths per year worldwide.All chronic liver diseases(CLDs),whether of toxic,genetic,autoimmune,or infectious origin,undergo typical histological changes in the structure of the tissue.These changes may include the accumulation of extracellular matrix material,fats,triglycerides,or tissue scarring.Noninvasive methods for diagnosing CLD,such as conventional B-mode ultrasound(US),play a significant role in diagnosis.Doppler US,when coupled with B-mode US,can be helpful in evaluating the hemodynamics of hepatic vessels and detecting US findings associated with hepatic decompensation.US elastography can assess liver stiffness,serving as a surrogate marker for liver fibrosis.It is important to note that interpreting these values should not rely solely on a histological classification.Contrast-enhanced US(CEUS)provides valuable information on tissue perfusion and enables excellent differentiation between benign and malignant focal liver lesions.Clinical evaluation,the etiology of liver disease,and the patient current comorbidities all influence the interpretation of liver stiffness measurements.These measurements are most clinically relevant when interpreted as a probability of compensated advanced CLD.B-mode US offers a subjective estimation of fatty infiltration and has limited sensitivity for mild steatosis.The controlled attenuation parameter requires a dedicated device,and cutoff values are not clearly defined.Quan-titative US parameters for liver fat estimation include the attenuation coefficient,backscatter coefficient,and speed of sound.These parameters offer the advantage of providing fat quantification alongside B-mode evaluation and other US parameters.Multiparametric US(MPUS)of the liver introduces a new concept for complete noninvasive diagnosis.It encourages examiners to utilize the latest features of an US machine,including conventional B-mode,liver stiffness evaluation,fat quantification,dispersion imaging,Doppler US,and CEUS for focal liver lesion characterization.This comprehensive approach allows for diagnosis in a single examination,providing clinicians worldwide with a broader perspective and becoming a cornerstone in their diagnostic arsenal.MPUS,in the hands of skilled clinicians,becomes an invaluable predictive tool for diagnosing,staging,and monitoring CLD. 展开更多
关键词 Multiparametric ultrasound ultrasound-based elastography Liver stiffness Noninvasive diagnostic test for chronic liver disease Liver steatosis assessment Portal hypertension evaluation
下载PDF
Past,present,and future perspectives of ultrasound-guided ablation of liver tumors:Where could artificial intelligence lead interventional oncology?
10
作者 Paola Tombesi Andrea Cutini +6 位作者 Valentina Grasso Francesca Di Vece Ugo Politti Eleonora Capatti Florence Labb Stefano Petaccia Sergio Sartori 《Artificial Intelligence in Cancer》 2024年第1期1-12,共12页
The first ablation procedures for small hepatocellular carcinomas were percutaneous ethanol injection under ultrasound(US)guidance.Later,radiofrequency ablation was shown to achieve larger coagulation areas than percu... The first ablation procedures for small hepatocellular carcinomas were percutaneous ethanol injection under ultrasound(US)guidance.Later,radiofrequency ablation was shown to achieve larger coagulation areas than percutaneous ethanol injection and became the most used ablation technique worldwide.In the past decade,microwave ablation systems have achieved larger ablation areas than radiofrequency ablation,suggesting that the 3-cm barrier could be broken in the treatment of liver tumors.Likewise,US techniques to guide percutaneous ablation have seen important progress.Contrast-enhanced US(CEUS)can define and target the tumor better than US and can assess the size of the ablation area after the procedure,which allows immediate retreatment of the residual tumor foci.Furthermore,fusion imaging fuses real-time US images with computed tomography or magnetic resonance imaging with significant improvements in detecting and targeting lesions with low conspicuity on CEUS.Recently,software powered by artificial intelligence has been developed to allow three-dimensional segmentation and reconstruction of the anatomical structures,aiding in procedure planning,assessing ablation completeness,and targeting the residual viable foci with greater precision than CEUS.Hopefully,this could lead to the ablation of tumors up to 5-7 cm in size. 展开更多
关键词 Artificial intelligence Fusion imaging Percutaneous thermal ablation Microwave ablation Radiofrequency ablation ultrasound Contrast-enhanced ultrasound
下载PDF
The Application Value of Ultrasound Imaging in the Differential Diagnosis of Benign and Malignant Breast Nodules of BI-RADS 3 and Above
11
作者 Dongmei Chen 《Proceedings of Anticancer Research》 2024年第2期53-58,共6页
Objective:To explore the diagnostic value of ultrasound imaging for breast nodules of breast imaging-reporting and data system(BI-RADS)category 3 and above.Methods:From June 2021 to July 2022,163 patients with breast ... Objective:To explore the diagnostic value of ultrasound imaging for breast nodules of breast imaging-reporting and data system(BI-RADS)category 3 and above.Methods:From June 2021 to July 2022,163 patients with breast nodules of BI-RADS 3 or above were selected as the research subjects.After pathological diagnosis,24 cases were malignant breast nodules of BI-RADS 3 or above,while 139 cases were benign breast nodules of BI-RADS 3 or above.The diagnosis rate of malignant and benign breast nodules of BI-RADS 3 or above,including 95%CI,was observed and analyzed.Results:The malignant and benign detection rates of conventional ultrasound were 88.63%and 75.00%,respectively,and the malignant and benign detection rates of ultrasound imaging were 93.18%and 87.50%,respectively,with 95%CIs greater than 0.7.Conclusion:Ultrasound imaging can help improve the diagnostic accuracy of benign and malignant breast nodules of BI-RADS 3 and above and reduce the misdiagnosis rate. 展开更多
关键词 ultrasound ultrasound imaging Breast imaging-reporting and data system(BI-RADS)category 3 and above Diagnosis
下载PDF
Endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction in Mexico
12
作者 Massiel Madelin Rosario-Morel Rodrigo Soto-Solis +5 位作者 Katia Picazo-Ferrera Miriam Idalia Torres-Ruiz JoséAlberto Estradas-Trujillo Mario Alberto Gallardo-Ramírez Gerardo Akram Darwich-del Moral Luis Ariel Waller-González 《World Journal of Surgical Procedures》 2024年第3期15-20,共6页
BACKGROUND Endoscopic ultrasound-guided gastroenterostomy(EUS-GE)has recently emerged as an alternative treatment for gastric outlet obstruction(GOO)in selected patients.AIM To report the initial experience of EUS-GE ... BACKGROUND Endoscopic ultrasound-guided gastroenterostomy(EUS-GE)has recently emerged as an alternative treatment for gastric outlet obstruction(GOO)in selected patients.AIM To report the initial experience of EUS-GE in patients with GOO.METHODS This study was a retrospective,observational,multicenter study in which the data from 10 patients who underwent EUS-GE due to GOO between September 2021 and May 2023 were collected.We analyzed technical success,clinical success,adverse events,and survival.Technical success was defined as adequate positioning and deployment of the stent.Clinical success was defined as the patient’s ability to tolerate oral intake without vomiting 7 d after the procedure.Postprocedural adverse events were recorded.RESULTS Eleven procedures in 10 patients with GOO were included.The mean age of the patients was 67.5 years(range:56-77 years).Malignant GOO was present in 9 patients.Technical success was achieved in 9/11 procedures(82%).Among them,clinical success was achieved in 9 patients(100%).Adverse events occurred in 1 patient(9%).The median survival was 3 months(n=7;range:1-8 months).CONCLUSION EUS-GE is a feasible therapeutic option in the treatment of GOO. 展开更多
关键词 Endoscopic ultrasound-guided gastroenterostomy Gastric outlet obstruction Lumen apposing metal stent Interventional endoscopic ultrasound GASTROJEJUNOSTOMY Duodenal stenting
下载PDF
Diagnostic and therapeutic role of endoscopic ultrasound in liver diseases:A systematic review and meta-analysis 被引量:2
13
作者 Eyad Gadour Abeer Awad +3 位作者 Zeinab Hassan Khalid Jebril Shrwani Bogdan Miutescu Hussein Hassan Okasha 《World Journal of Gastroenterology》 SCIE CAS 2024年第7期742-758,共17页
BACKGROUND In hepatology,the clinical use of endoscopic ultrasound(EUS)has experienced a notable increase in recent times.These applications range from the diagnosis to the treatment of various liver diseases.Therefor... BACKGROUND In hepatology,the clinical use of endoscopic ultrasound(EUS)has experienced a notable increase in recent times.These applications range from the diagnosis to the treatment of various liver diseases.Therefore,this systematic review summarizes the evidence for the diagnostic and therapeutic roles of EUS in liver diseases.AIM To examine and summarize the current available evidence of the possible roles of the EUS in making a suitable diagnosis in liver diseases as well as the therapeutic accuracy and efficacy.METHODS PubMed,Medline,Cochrane Library,Web of Science,and Google Scholar databases were extensively searched until October 2023.The methodological quality of the eligible articles was assessed using the Newcastle-Ottawa scale or Cochrane Risk of Bias tool.In addition,statistical analyses were performed using the Comprehensive Meta-Analysis software.RESULTS Overall,45 articles on EUS were included(28 on diagnostic role and 17 on therapeutic role).Pooled analysis demonstrated that EUS diagnostic tests had an accuracy of 92.4%for focal liver lesions(FLL)and 96.6%for parenchymal liver diseases.EUS-guided liver biopsies with either fine needle aspiration or fine needle biopsy had low complication rates when sampling FLL and parenchymal liver diseases(3.1%and 8.7%,respectively).Analysis of data from four studies showed that EUS-guided liver abscess had high clinical(90.7%)and technical success(90.7%)without significant complications.Similarly,EUS-guided interventions for the treatment of gastric varices(GV)have high technical success(98%)and GV obliteration rate(84%)with few complications(15%)and rebleeding events(17%).CONCLUSION EUS in liver diseases is a promising technique with the potential to be considered a first-line therapeutic and diagnostic option in selected cases. 展开更多
关键词 Focal liver lesion Liver abscess drainage Fine needle aspiration Gastric varices Endoscopic ultrasound
下载PDF
Novel approach of ultrasound-guided lateral recess block for a patient with lateral recess stenosis: A case report 被引量:1
14
作者 Jiao Yang Xin-Ling Li Qing-Bing Li 《World Journal of Clinical Cases》 SCIE 2024年第5期1010-1017,共8页
BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultraso... BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultrasound-guided Lateral recess block(LRB)are limited,this is probably because there is no recognized standard method for ultrasound scanning.This study aimed to evaluate the effect of ultrasound-guided LRB in patients with lateral recess stenosis(LRS).CASE SUMMARY A 65-year-old patient complained of low back pain accompanied occasionally by pain and numbness in the left lower limb.Physical examination showed ten-derness on the spinous process and paraspinal muscles from L1 to S1,extensor hallucis longus and tibialis anterior weakness(muscle strength:4-),and a positive straight leg raising test in the left lower limb(60°).Magnetic resonance imaging showed L4–L5 disc degeneration with left LRS and nerve root entrapment.Subsequently,the patient was diagnosed with LRS.This patient was treated with a novel ultrasound-guided LRB approach.The patient’s symptoms significantly improved without any complications at 1 wk postoperatively and at the 3-month follow-up.CONCLUSION This is the first report on the LRS treatment with ultrasound-guided LRB from the contralateral spinous process along the inner side of the articular process by out-plane technique.Further studies are expected to investigate the efficacy and safety of ultrasound-guided LRB for patients with LRS. 展开更多
关键词 Lateral recess stenosis ultrasound Lateral recess block Real-time visualization Low back pain Case report
下载PDF
Ultrasound Scanning Competencies in Midwifery Education in Zambia: Findings from a Desk Review and Needs Assessment
15
作者 Mutinke Zulu Sebean Mayimbo Patricia Katowa-Mukwato 《Health》 2024年第6期535-552,共18页
Introduction: Ultrasound is an essential component of antenatal care. Midwives provide most of the antenatal care but they do not perform ultrasound as it has been beyond their scope of practice. This leaves many wome... Introduction: Ultrasound is an essential component of antenatal care. Midwives provide most of the antenatal care but they do not perform ultrasound as it has been beyond their scope of practice. This leaves many women in Low and Middle-Income Countries without access to ultrasound scanning. The aim of this study was to identify competencies in ultrasound scanning in midwifery education. Methods: A desk review and needs assessment were conducted between July and October 2023. Articles and curricula on the internet, Google scholar and PubMed were searched for content on ultrasound scanning competencies. A Google form consisting of 20 questions was administered via email and WhatsApp to 135 participants. Descriptive statistics were used to analyse data. Results: The desk review showed that it is feasible to train midwives in ultrasound scanning. The training programs for midwives in obstetric ultrasound were conducted for 1 week to 3 months with most of them running for 4 weeks. Content included introduction to general principles of ultrasound, physics, basic knowledge in embryology, obstetrics, anatomy, measuring foetal biometry, estimating amniotic fluid and gestational age. Experts like sonographers trained midwives. Theory and hands on were the teaching methods used. Written and practical assessments were conducted. Needs assessment revealed that majority of participants 71 (53%) knew about basic ultrasound training for midwives. All participants (100%) said it is necessary to train midwives in basic ultrasound scan in Zambia. Some content should include, anatomy, measuring foetal biometry, assessing amniotic fluid level, and gestational age determination. Most participants 91 (67%) suggested that the appropriate duration of training is 4 - 6 weeks. Conclusion: Empowering every midwife with ultrasound scanning skills will enable early detection of any abnormality among pregnant women and prompt intervention to save lives. 展开更多
关键词 ultrasound Scanning Midwifery Education Competencies
下载PDF
Clinical Study of Double Contrast-Enhanced Ultrasound Combined with Dye Method and Marker Placement to Identify and Locate Sentinel Lymph Nodes in Patients with Breast Cancer
16
作者 Dayan Yang Lini Gao 《Advances in Breast Cancer Research》 CAS 2024年第3期49-58,共10页
Objective: To explore the value of percutaneous ultrasonography combined with transvenous ultrasonography for accurate localization of sentinel lymph nodes and diagnosis of metastatic lymph nodes in patients with brea... Objective: To explore the value of percutaneous ultrasonography combined with transvenous ultrasonography for accurate localization of sentinel lymph nodes and diagnosis of metastatic lymph nodes in patients with breast cancer. Methods: 18 cases of patients with breast cancer attending the Hainan General Hospital from May 2022 to June 2024 who were proposed to undergo axillary lymph node dissection were selected, and the ultrasonographic agent was injected subcutaneously through the areola on the 1st day before the operation, and the marker localization of the manifestation of the Sentinel lymph nodes and draw the lymphatic vessel alignment for drainage on the body surface, and record the manifestation of SLN by conventional ultrasound and dual ultrasonography. At the time of surgery, intraoperative melphalan localization was used to identify the SLN, the difference between the number of ultrasound and melphalan localization was observed, and resection was performed for pathological examination to determine whether they were metastatic or not. Results: There were 8 metastatic lymph nodes and 18 non-metastatic lymph nodes among 31 SLN. A total of 62 SLN were localized by intraoperative melphalan, of which 31 were consistent with ultrasound localization and 31 were not identified by ultrasound. The diagnostic sensitivity of SLN metastasis diagnosed by transcutaneous ultrasonography was 62.50%, specificity was 91.30%, positive predictive value was 71.43%, negative predictive value 87.50%, accuracy was 83.87%, and the AUC was 0.769;the diagnostic sensitivityof transvenous ultrasonography diagnosed was 75.00%, specificity was 75.00%, and the accuracy was 83.87%, 75.00%, specificity 91.30%, positive predictive value 75.00%, negative predictive value 91.30%, accuracy 87.10%, AUC 0.832;dual ultrasonography diagnostic sensitivity 87.50%, specificity 91.30%, positive predictive value 77.78%, negative predictive value 95.45%, accuracy 90.32%. The AUC was 0.894. Conclusion: Transcutaneous ultrasonography combined with transvenous ultrasonography can accurately localize sentinel lymph nodes and improve the sensitivity and accuracy of the diagnosis of metastatic SLN. 展开更多
关键词 Sentinel Lymph Nodes Breast Cancer ultrasound ULTRASONOGRAPHY Axillary Lymph Nodes
下载PDF
Quick and easy assessment of sarcopenia in cirrhosis: Can ultrasound be the solution?
17
作者 Francesca Campani Tancredi Vincenzo Li Cavoli +3 位作者 Umberto Arena Fabio Marra Erica Nicola Lynch Claudia Campani 《World Journal of Gastroenterology》 SCIE CAS 2024年第17期2287-2293,共7页
Cirrhosis is frequently associated with sarcopenia,with reported rates of over 80%in patients with decompensated alcohol-related liver disease.Sarcopenia nega-tively impacts the prognosis of cirrhotic patients and aff... Cirrhosis is frequently associated with sarcopenia,with reported rates of over 80%in patients with decompensated alcohol-related liver disease.Sarcopenia nega-tively impacts the prognosis of cirrhotic patients and affects the response to treatment of patients with hepatocellular carcinoma(HCC).For these reasons,identifying an easy-to-perform method to assess sarcopenia in is a key element in the optimization of care in this patient population.Assessment of muscle mass by computed tomography is considered the standard of care for the diagnosis of sarcopenia,but exposure to radiation and high costs limit its application in this setting,especially for repeated assessments.We believe that ultrasound,a cheap and harmless technique also used for HCC screening in cirrhotic patients,could have an expanding role in the diagnosis and follow-up of sarcopenia in these patients. 展开更多
关键词 SARCOPENIA ultrasound CIRRHOSIS Hepatocellular carcinoma Computed tomography
下载PDF
Suppression of low-frequency ultrasound broadband vibration using star-shaped single-phase metamaterials
18
作者 Rui Zhao Jian Zheng +4 位作者 Jin Guo Yunbo Shi Hengzhen Feng Jun Tang Jun Liu 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第4期217-224,共8页
In order to suppress the low-frequency ultrasound vibration in the broadband range of 20 k Hz—100 k Hz,this paper proposes and discusses an acoustic metamaterial with low-frequency ultrasound vibration attenuation pr... In order to suppress the low-frequency ultrasound vibration in the broadband range of 20 k Hz—100 k Hz,this paper proposes and discusses an acoustic metamaterial with low-frequency ultrasound vibration attenuation properties,which is configured by hybrid arc and sharp-angle convergent star-shaped lattices.The effect of the dispersion relation and the bandgap characteristic for the scatterers in star-shaped are simulated and analyzed.The target bandgap width is extended by optimizing the geometry parameters of arc and sharp-angle convergent lattices.The proposed metamaterial configured by optimized hybrid lattices exhibits remarkable broad bandgap characteristics by bandgap complementarity,and the simulation results verify a 99%vibration attenuation amplitude can be obtained in the frequency of20 k Hz—100 k Hz.After the fabrication of the proposed hybrid configurational star-shaped metamaterial by 3D printing technique,the transmission loss experiments are performed,and the experimental results indicate that the fabricated metamaterial has the characteristics of broadband vibration attenuation and an amplitude greater than 85%attenuation for the target frequency.These results demonstrate that the hybrid configurational star-shaped metamaterials can effectively widen the bandgap and realize high efficiency attenuation,which has capability for the vibration attenuation in the application of highprecise equipment. 展开更多
关键词 Star-shaped metamaterials BROADBAND Vibration attenuation Low-frequency ultrasound vibration Transmission loss
下载PDF
Added value of ratio of cross diameters of the appendix in ultrasound diagnosis of acute appendicitis
19
作者 Feng-Wa Gu Si-Ze Wu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第1期21-28,共8页
BACKGROUND The maximum outer diameter(MOD)of the appendix is an essential parameter for diagnosing acute appendicitis,but there is space for improvement in ultrasound(US)diagnostic performance.AIM To investigate wheth... BACKGROUND The maximum outer diameter(MOD)of the appendix is an essential parameter for diagnosing acute appendicitis,but there is space for improvement in ultrasound(US)diagnostic performance.AIM To investigate whether combining the ratio of the cross diameters(RATIO)of the appendix with MOD of the appendix can enhance the diagnostic performance of acute appendicitis.METHODS A retrospective study was conducted,and medical records of 233 patients with acute appendicitis and 112 patients with a normal appendix were reviewed.The MOD and RATIO of the appendix were calculated and tested for their diagnostic performance of acute appendicitis,both individually and in combination.RESULTS The RATIO for a normal appendix was 1.32±0.16,while for acute appendicitis it was 1.09±0.07.The cut-off value for RATIO was determined to be≤1.18.The area under the receiver operating characteristic curve(AUC)for diagnosing acute appendicitis using RATIO≤1.18 and MOD>6 mm was 0.870 and 0.652,respectively.There was a significant difference in AUC between RATIO≤1.18 and MOD>6 mm(P<0.0001).When comparing the combination of RATIO≤1.18 and MOD>6 mm with MOD>6 mm alone,the combination showed increased specificity,positive predictive value(PPV),and AUC.However,the sensitivity and negative predictive value decreased.CONCLUSION Combining RATIO of the appendix≤1.18 and MOD>6 mm can significantly improve the specificity,PPV,and AUC in the US diagnosis of acute appendicitis. 展开更多
关键词 Acute appendicitis DIAMETER RATIO Diagnosis ultrasound
下载PDF
Contribution and Relevance of Transfontanellar Ultrasound in Newborns in Ouagadougou: Multicentre Study on 1000 Cases
20
作者 Ouedraogo Pakisba Ali Ouedraogo Nina-Astrid +7 位作者 Somé Milckisédek Judickael Dabire Stive Arnauld Tankoano Ida Aida Napon Aischa Madina Nikiema Zakari Diallo Ousseini Lougue Sorgho Leonie Claudine Cisse Rabiou 《Open Journal of Radiology》 2024年第2期64-73,共10页
Objectives: To demonstrate the contribution and relevance of ETFs through the study of 1000 examination reports carried out in the medical imaging departments of the OUAGADOUGOU CHU. Material and method: Analytical de... Objectives: To demonstrate the contribution and relevance of ETFs through the study of 1000 examination reports carried out in the medical imaging departments of the OUAGADOUGOU CHU. Material and method: Analytical descriptive study with retrospective collection, extended from 1st January 2020 to 1st January 2022. Results: Of the 1000 transfontanellar ultrasound reports, the mean age of patients was 7.61 +/ 7.5 days, with extremes of zero and 28 days. Sex was specified in 989 cases. Males accounted for 54.49% and females for 45.51%. 555 transfontanellar ultrasound were performed in 2020. 441 in 2021 and 4 in 2022. 61.9% of transfontanellar ultrasound were performed at the Bogodogo University Hospital, 205 at Charles de Gaulle and 176 at Tengandogo. Indications for transfontanellar ultrasound were dominated by neonatal distress (65.8%), followed by convulsions (10.2%) and prematurity (9.1%). Transfontanellar ultrasound was normal in 570 cases (57%) and abnormal in 430 cases (43%). Abnormalities were dominated by haemorrhage and ischaemic lesions in 66.28% (285) and 21.63% (93) of cases respectively. In the group of normal transfontanellar ultrasound, neonatal distress represented 59.65% of indications and prematurity 10.7% of indications. As for abnormal transfontanellar ultrasound, neonatal suffering accounted for 73.95% of indications and convulsions for 12.56%. The average age ofpatients with an abnormal transfontanellar ultrasound was 8.74 days +/ 7.89 days. The indication for investigations was relevant in 42.2% of cases and irrelevant in 57.8%;of the transfontanellar ultrasound with relevant indications, 0.71 were normal and 99.29 abnormal;of the transfontanellar ultrasound with irrelevant indications, the transfontanellar ultrasound was normal in 98.1% and abnormal in 1.9%. Conclusion: Transfontanellar ultrasound is an important part of ultrasound in current practice. Haemorrhage, anoxic-ischaemic lesions and hydrocephalus are the most frequent pathologies found by this technique in newborns. Whether or not the examinations were normal depended on the appropriateness of the prescription. 展开更多
关键词 Transfontanellar ultrasound Neonatal Distress RELEVANCE
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部