As positioning sensors,edge computation power,and communication technologies continue to develop,a moving agent can now sense its surroundings and communicate with other agents.By receiving spatial information from bo...As positioning sensors,edge computation power,and communication technologies continue to develop,a moving agent can now sense its surroundings and communicate with other agents.By receiving spatial information from both its environment and other agents,an agent can use various methods and sensor types to localize itself.With its high flexibility and robustness,collaborative positioning has become a widely used method in both military and civilian applications.This paper introduces the basic fundamental concepts and applications of collaborative positioning,and reviews recent progress in the field based on camera,LiDAR(Light Detection and Ranging),wireless sensor,and their integration.The paper compares the current methods with respect to their sensor type,summarizes their main paradigms,and analyzes their evaluation experiments.Finally,the paper discusses the main challenges and open issues that require further research.展开更多
This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally ...This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally invasive and effective technique for drainage in patients with acute cholecystitis with high risk of surgery.The procedure has demonstrated impressive technical and clinical success rates with low rates of adverse events,making it a safe and effective option for appropriate candidates.Furthermore,EUS-GBD can also serve as a rescue option for patients who have failed endoscopic retrograde cholangiopancreatography or EUS biliary drainage for relief of jaundice in malignant biliary stricture.However,patient selection is critical for the success of EUS-GBD,and proper patient selection and risk assessment are important to ensure the safety and efficacy of the procedure.As the field continues to evolve and mature,ongoing research will further refine our understanding of the benefits and limitations of EUS-GBD,ultimately leading to improved outcomes for patients.展开更多
The existing indoor fusion positioning methods based on Pedestrian Dead Reckoning(PDR)and geomagnetic technology have the problems of large initial position error,low sensor accuracy,and geomagnetic mismatch.In this s...The existing indoor fusion positioning methods based on Pedestrian Dead Reckoning(PDR)and geomagnetic technology have the problems of large initial position error,low sensor accuracy,and geomagnetic mismatch.In this study,a novel indoor fusion positioning approach based on the improved particle filter algorithm by geomagnetic iterative matching is proposed,where Wi-Fi,PDR,and geomagnetic signals are integrated to improve indoor positioning performances.One important contribution is that geomagnetic iterative matching is firstly proposed based on the particle filter algorithm.During the positioning process,an iterative window and a constraint window are introduced to limit the particle generation range and the geomagnetic matching range respectively.The position is corrected several times based on geomagnetic iterative matching in the location correction stage when the pedestrian movement is detected,which made up for the shortage of only one time of geomagnetic correction in the existing particle filter algorithm.In addition,this study also proposes a real-time step detection algorithm based on multi-threshold constraints to judge whether pedestrians are moving,which satisfies the real-time requirement of our fusion positioning approach.Through experimental verification,the average positioning accuracy of the proposed approach reaches 1.59 m,which improves 33.2%compared with the existing particle filter fusion positioning algorithms.展开更多
Background:To prevent stent migration during endoscopic ultrasound-guided hepaticogastrostomy(EUS-HGS),intra-scope channel release technique is important,but is unfamiliar to non-expert hands.The self-expandable metal...Background:To prevent stent migration during endoscopic ultrasound-guided hepaticogastrostomy(EUS-HGS),intra-scope channel release technique is important,but is unfamiliar to non-expert hands.The self-expandable metal stent(SEMS)is an additional factor to prevent stent migration.However,no compara-tive studies of laser-cut-type and braided-type during EUS-HGS have been reported.The aim of this study was to compare the distance between the intrahepatic bile duct and stomach wall after EUS-HGS among laser-cut-type and braided-type SEMS.Methods:To evaluate stent anchoring function,we measured the distance between the hepatic parenchyma and stomach wall before EUS-HGS,one day after EUS-HGS,and 7 days after EUS-HGS.Also,propensity score matching was performed to create a propensity score for using laser-cut-type group and braided-type group.Results:A total of 142 patients were enrolled in this study.Among them,24 patients underwent EUS-HGS using a laser-cut-type SEMS,and 118 patients underwent EUS-HGS using a braided-type SEMS.EUS-HGS using the laser-cut-type SEMS was mainly performed by non-expert endoscopists(n=21);EUS-HGS using braided-type SEMS was mainly performed by expert endoscopists(n=98).The distance after 1 day was significantly shorter in the laser-cut-type group than that in the braided-type group[2.00(1.70-3.75)vs.6.90(3.72-11.70)mm,P<0.001].In addition,this distance remained significantly shorter in the laser-cut-type group after 7 days.Although these results were similar after propensity score matching analysis,the distance between hepatic parenchyma and stomach after 7 days was increased by 4 mm compared with the distance after 1 day in the braided-type group.On the other hand,in the laser-cut-type group,the distance after 1 day and 7 days was almost the same.Conclusions:EUS-HGS using a laser-cut-type SEMS may be safe to prevent stent migration,even in non-expert hands.展开更多
BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guide...BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guided coaxial core needle biopsy(CNB)not only procures sufficient tissue to help clarify the diagnosis,but reduces the incidence of puncture-related complications.CASE SUMMARY A 41-year-old female,with a history of pulmonary tuberculosis,was admitted to our hospital with multiple indeterminate splenic lesions.Gray-scale ultrasono-graphy demonstrated splenomegaly with numerous well-defined hypoechoic ma-sses.Abdominal contrast-enhanced computed tomography(CT)showed an en-larged spleen with multiple irregular-shaped,peripherally enhancing,hypodense lesions.Positron emission CT revealed numerous abnormal hyperglycemia foci.These imaging findings strongly indicated the possibility of infectious disease as the primary concern,with neoplastic lesions requiring exclusion.To obtain the precise pathological diagnosis,the US-guided coaxial CNB of the spleen was ca-rried out.The patient did not express any discomfort during the procedure.CONCLUSION Percutaneous US-guided coaxial CNB is an excellent and safe option for obtaining precise splenic tissue samples,as it significantly enhances sample yield for exact pathological analysis with minimum trauma to the spleen parenchyma and sur-rounding tissue.展开更多
BACKGROUND Pancreatic ductal leaks complicated by endoscopic ultrasonography-guided tissue sampling(EUS-TS)can manifest as acute pancreatitis.CASE SUMMARY A 63-year-old man presented with persistent abdominal pain and...BACKGROUND Pancreatic ductal leaks complicated by endoscopic ultrasonography-guided tissue sampling(EUS-TS)can manifest as acute pancreatitis.CASE SUMMARY A 63-year-old man presented with persistent abdominal pain and weight loss.Diagnosis:Laboratory findings revealed elevated carbohydrate antigen 19-9(5920 U/mL)and carcinoembryonic antigen(23.7 ng/mL)levels.Magnetic resonance imaging of the pancreas revealed an approximately 3 cm ill-defined space-occupying lesion in the inferior aspect of the head,with severe encasement of the superior mesenteric artery.Pancreatic ductal adenocarcinoma was confirmed after pathological examination of specimens obtained by EUS-TS using the fanning method.Interventions and outcomes:The following day,the patient experienced severe abdominal pain with high amylase(265 U/L)and lipase(1173 U/L)levels.Computed tomography of the abdomen revealed edematous wall thickening of the second portion of the duodenum with adjacent fluid collections and a suspicious leak from either the distal common bile duct or the main pancreatic duct in the head.Endoscopic retrograde cholangiopancreatography revealed dye leakage in the head of the main pancreatic duct.Therefore,a 5F 7 cm linear plastic stent was deployed into the pancreatic duct to divert the pancreatic juice.The patient’s abdominal pain improved immediately after pancreatic stent insertion,and amylase and lipase levels normalized within a week.Neoadjuvant chemotherapy was then initiated.CONCLUSION Using the fanning method in EUS-TS can inadvertently cause damage to the pancreatic duct and may lead to clinically significant pancreatitis.Placing a pancreatic stent may immediately resolve acute pancreatitis and shorten the waiting time for curative therapy.When using the fanning method during EUSTS,ductal structures should be excluded to prevent pancreatic ductal leakage.展开更多
To solve the problem of data fusion for prior information such as track information and train status in train positioning,an adaptive H∞filtering algorithm with combination constraint is proposed,which fuses prior in...To solve the problem of data fusion for prior information such as track information and train status in train positioning,an adaptive H∞filtering algorithm with combination constraint is proposed,which fuses prior information with other sensor information in the form of constraints.Firstly,the train precise track constraint method of the train is proposed,and the plane position constraint and train motion state constraints are analysed.A model for combining prior information with constraints is established.Then an adaptive H∞filter with combination constraints is derived based on the adaptive adjustment method of the robustness factor.Finally,the positioning effect of the proposed algorithm is simulated and analysed under the conditions of a straight track and a curved track.The results show that the positioning accuracy of the algorithm with constrained filtering is significantly better than that of the algorithm without constrained filtering and that the algorithm with constrained filtering can achieve better performance when combined with track and condition information,which can significantly reduce the train positioning error.The effectiveness of the proposed algorithm is verified.展开更多
Accurate positioning is one of the essential requirements for numerous applications of remote sensing data,especially in the event of a noisy or unreliable satellite signal.Toward this end,we present a novel framework...Accurate positioning is one of the essential requirements for numerous applications of remote sensing data,especially in the event of a noisy or unreliable satellite signal.Toward this end,we present a novel framework for aircraft geo-localization in a large range that only requires a downward-facing monocular camera,an altimeter,a compass,and an open-source Vector Map(VMAP).The algorithm combines the matching and particle filter methods.Shape vector and correlation between two building contour vectors are defined,and a coarse-to-fine building vector matching(CFBVM)method is proposed in the matching stage,for which the original matching results are described by the Gaussian mixture model(GMM).Subsequently,an improved resampling strategy is designed to reduce computing expenses with a huge number of initial particles,and a credibility indicator is designed to avoid location mistakes in the particle filter stage.An experimental evaluation of the approach based on flight data is provided.On a flight at a height of 0.2 km over a flight distance of 2 km,the aircraft is geo-localized in a reference map of 11,025 km~2using 0.09 km~2aerial images without any prior information.The absolute localization error is less than 10 m.展开更多
Pancreatic fluid collections(PFCs)result from injury to the pancreas from acute or chronic pancreatitis,surgery,or trauma.Management of these collections has evolved over the last 2 decades.The choice of interventions...Pancreatic fluid collections(PFCs)result from injury to the pancreas from acute or chronic pancreatitis,surgery,or trauma.Management of these collections has evolved over the last 2 decades.The choice of interventions includes percu-taneous,endoscopic,minimally invasive surgery,or a combined approach.Endoscopic drainage is the drainage of PFCs by creating an artificial communication between the collection and gastrointestinal lumen that is maintained by placing a stent across the fistulous tract.In this editorial,we endeavored to update the current status of endoscopic ultrasound-guided drainage of PFCs.展开更多
The development of the fifth-generation(5G)mobile communication systems has entered the commercialization stage.5G has a high data rate,low latency,and high reliability that can meet the basic demands of most industri...The development of the fifth-generation(5G)mobile communication systems has entered the commercialization stage.5G has a high data rate,low latency,and high reliability that can meet the basic demands of most industries and daily life,such as the Internet of Things(IoT),intelligent transportation systems,positioning,and navigation.The continuous progress and development of society have aroused wide concern.Positioning accuracy is the core demand for the applications,especially in complex environments such as airports,warehouses,supermarkets,and basements.However,many factors also affect the accuracy of positioning in those environments,for example,multipath effects,non-line-of-sight,and clock synchronization errors.This paper provides a comprehensive review of the existing works about positioning for the future wireless network and discusses its key techniques and algorithms,as well as the current development and future directions.We first outline the current traditional positioning technologies and algorithms,which are discussed and analyzed with the relevant literature.In addition,we also discuss application scenarios for wireless localization.By comparing different positioning systems,the challenges and future development directions of existing wireless positioning systems are prospected.展开更多
Obtaining precise position of interested emitters passively has wide applications in both civilian and military fields.Different from traditional parameter measurement and direct position determination(DPD)method,rece...Obtaining precise position of interested emitters passively has wide applications in both civilian and military fields.Different from traditional parameter measurement and direct position determination(DPD)method,recently a new passive localization method based on synthetic aper-ture technique,named synthetic aperture positioning(SAP),has been proposed.The method com-pensates for the nonlinear phase produced by relative motion between the moving platform and the emitter,achieving coherent summation of intercepted signals.The SAP can obtain high-resolution and high-precision localization results at a low signal-to-noise ratio.This paper summarizes the research progress of SAP,including localization principles,spaceborne applications,and application scope analysis.Besides,the possible future outlook of SAP is considered.展开更多
Pedestrian positioning system(PPS)using wearable inertial sensors has wide applications towards various emerging fields such as smart healthcare,emergency rescue,soldier positioning,etc.The performance of traditional ...Pedestrian positioning system(PPS)using wearable inertial sensors has wide applications towards various emerging fields such as smart healthcare,emergency rescue,soldier positioning,etc.The performance of traditional PPS is limited by the cumulative error of inertial sensors,complex motion modes of pedestrians,and the low robustness of the multi-sensor collaboration structure.This paper presents a hybrid pedestrian positioning system using the combination of wearable inertial sensors and ultrasonic ranging(H-PPS).A robust two nodes integration structure is developed to adaptively combine the motion data acquired from the single waist-mounted and foot-mounted node,and enhanced by a novel ellipsoid constraint model.In addition,a deep-learning-based walking speed estimator is proposed by considering all the motion features provided by different nodes,which effectively reduces the cumulative error originating from inertial sensors.Finally,a comprehensive data and model dual-driven model is presented to effectively combine the motion data provided by different sensor nodes and walking speed estimator,and multi-level constraints are extracted to further improve the performance of the overall system.Experimental results indicate that the proposed H-PPS significantly improves the performance of the single PPS and outperforms existing algorithms in accuracy index under complex indoor scenarios.展开更多
BACKGROUND Malignant obstructive jaundice(MOJ)is a condition characterized by varying degrees of bile duct stenosis and obstruction,accompanied by the progressive development of malignant tumors,leading to high morbid...BACKGROUND Malignant obstructive jaundice(MOJ)is a condition characterized by varying degrees of bile duct stenosis and obstruction,accompanied by the progressive development of malignant tumors,leading to high morbidity and mortality rates.Currently,the two most commonly employed methods for its management are percutaneous transhepatic bile duct drainage(PTBD)and endoscopic ultrasound-guided biliary drainage(EUS-BD).While both methods have demonstrated favorable outcomes,additional research needs to be performed to determine their relative efficacy.To compare the therapeutic effectiveness of EUS-BD and PTBD in treating MOJ.METHODS This retrospective analysis,conducted between September 2015 and April 2023 at The Third Affiliated Hospital of Soochow University(The First People’s Hospital of Changzhou),involved 68 patients with MOJ.The patients were divided into two groups on the basis of surgical procedure received:EUS-BD subgroup(n=33)and PTBD subgroup(n=35).Variables such as general data,preoperative and postoperative indices,blood routine,liver function indices,myocardial function indices,operative success rate,clinical effectiveness,and complication rate were analyzed and compared between the subgroups.RESULTS In the EUS-BD subgroup,hospital stay duration,bile drainage volume,effective catheter time,and clinical effect-iveness rate were superior to those in the PTBD subgroup,although the differences were not statistically significant(P>0.05).The puncture time for the EUS-BD subgroup was shorter than that for the PTBD subgroup(P<0.05).Postoperative blood routine,liver function index,and myocardial function index in the EUS-BD subgroup were significantly lower than those in the PTBD subgroup(P<0.05).Additionally,the complication rate in the EUS-BD subgroup was lower than in the PTBD subgroup(P<0.05).CONCLUSION EUS-BD may reduce the number of punctures,improve liver and myocardial functions,alleviate traumatic stress,and decrease complication rates in MOJ treatment.展开更多
The observation error model of the underwater acous-tic positioning system is an important factor to influence the positioning accuracy of the underwater target.For the position inconsistency error caused by consideri...The observation error model of the underwater acous-tic positioning system is an important factor to influence the positioning accuracy of the underwater target.For the position inconsistency error caused by considering the underwater tar-get as a mass point,as well as the observation system error,the traditional error model best estimation trajectory(EMBET)with little observed data and too many parameters can lead to the ill-condition of the parameter model.In this paper,a multi-station fusion system error model based on the optimal polynomial con-straint is constructed,and the corresponding observation sys-tem error identification based on improved spectral clustering is designed.Firstly,the reduced parameter unified modeling for the underwater target position parameters and the system error is achieved through the polynomial optimization.Then a multi-sta-tion non-oriented graph network is established,which can address the problem of the inaccurate identification for the sys-tem errors.Moreover,the similarity matrix of the spectral cluster-ing is improved,and the iterative identification for the system errors based on the improved spectral clustering is proposed.Finally,the comprehensive measured data of long baseline lake test and sea test show that the proposed method can accu-rately identify the system errors,and moreover can improve the positioning accuracy for the underwater target positioning.展开更多
In this paper,an antenna array composed of circular array and orthogonal linear array is proposed by using the design of long and short baseline“orthogonal linear array”and the circular array ambiguity resolution de...In this paper,an antenna array composed of circular array and orthogonal linear array is proposed by using the design of long and short baseline“orthogonal linear array”and the circular array ambiguity resolution design of multi-group baseline clustering.The effectiveness of the antenna array in this paper is verified by sufficient simulation and experiment.After the system deviation correction work,it is found that in the L/S/C/X frequency bands,the ambiguity resolution probability is high,and the phase difference system error between each channel is basically the same.The angle measurement error is less than 0.5°,and the positioning error is less than 2.5 km.Notably,as the center frequency increases,calibration consistency improves,and the calibration frequency points become applicable over a wider frequency range.At a center frequency of 11.5 GHz,the calibration frequency point bandwidth extends to 1200 MHz.This combined antenna array deployment holds significant promise for a wide range of applications in contemporary wireless communication systems.展开更多
In patients with liver tumors,the histopathology examination can assist in diagnosis,staging,prognosis,and therapeutic management strategy.Endoscopic ultrasound(EUS)-guided tissue acquisition using fine needle aspirat...In patients with liver tumors,the histopathology examination can assist in diagnosis,staging,prognosis,and therapeutic management strategy.Endoscopic ultrasound(EUS)-guided tissue acquisition using fine needle aspiration(FNA)or more newly fine needle biopsy(FNB)is a well-developed technique in order to evaluate and differentiate the liver masses.The goal of the EUS-FNA or EUS-FNB is to provide an accurate sample for a histopathology examination.Therefore,malignant tumors such as hepatocarcinoma,cholangiocarcinoma and liver metastasis or benign tumors such as liver adenoma,focal hyperplastic nodular tumors and cystic lesions can be accurately diagnosed using EUS-guided tissue acquisition.EUS-FNB using 19 or 22 Ga needle provide longer samples and a higher diagnostic accuracy in patients with liver masses when compared with EUS-FNA.Few data are available on the diagnostic accuracy of EUS-FNB when compared with percutaneously,ultrasound,computer tomography or transjugulary-guided liver biopsies.This review will discuss the EUS-guided tissue acquisition options in patients with liver tumors and its efficacy and safety in providing accurate samples.The results of the last studies comparing EUS-guided liver biopsy with other conventional techniques are presented.The EUS-guided tissue acquisition using FNB can be a suitable technique in suspected liver lesions in order to provide an accurate histopathology diagnosis,especially for those who require endoscopy.展开更多
The near-seabed multichannel seismic exploration systems have yielded remarkable successes in marine geological disaster assessment,marine gas hydrate investigation,and deep-sea mineral exploration owing to their high...The near-seabed multichannel seismic exploration systems have yielded remarkable successes in marine geological disaster assessment,marine gas hydrate investigation,and deep-sea mineral exploration owing to their high vertical and horizontal resolution.However,the quality of deep-towed seismic imaging hinges on accurate source-receiver positioning information.In light of existing technical problems,we propose a novel array geometry inversion method tailored for high-resolution deep-towed multichannel seismic exploration systems.This method is independent of the attitude and depth sensors along a deep-towed seismic streamer,accounting for variations in seawater velocity and seabed slope angle.Our approach decomposes the towed line array into multiline segments and characterizes its geometric shape using the line segment distance and pitch angle.Introducing optimization parameters for seawater velocity and seabed slope angle,we establish an objective function based on the model,yielding results that align with objective reality.Employing the particle swarm optimization algorithm enables synchronous acquisition of optimized inversion results for array geometry and seawater velocity.Experimental validation using theoretical models and practical data verifies that our approach effectively enhances source and receiver positioning inversion accuracy.The algorithm exhibits robust stability and reliability,addressing uncertainties in seismic traveltime picking and complex seabed topography conditions.展开更多
The inhomogeneous sound speed in seawater causes refraction of sound waves,and the elimination of the refraction effect is essential to the accuracy of underwater acoustic positioning.The raytracing method is an indis...The inhomogeneous sound speed in seawater causes refraction of sound waves,and the elimination of the refraction effect is essential to the accuracy of underwater acoustic positioning.The raytracing method is an indispensable tool for effectively handling problems.However,this method has a conflict between localization accuracy and computational quantity.The equivalent sound speed profile(ESSP)method uses a simple sound speed profile(SSP)instead of the actual complex SSP,which can improve positioning precision but with residual error.The residual error is especially non-negligible in deep water and at large beam incidence angles.By analyzing the residual error of the ESSP method through a simulation,an empirical formula of error is presented.The data collected in the sailing circle mode(large incidence angle)of the South China Sea are used for verification.The experiments show that compared to the ESSP method,the improved algorithm has higher positioning precision and is more efficient than the ray-tracing method.展开更多
The development of this technology has favored the advances noted in recent years in the field of precise positioning. It has also paved the way for a wide range of research into the evaluation of their performance an...The development of this technology has favored the advances noted in recent years in the field of precise positioning. It has also paved the way for a wide range of research into the evaluation of their performance and reliability, their potential use in different fields, the improvement of performance and combined systems, etc. Single-frequency GNSS receivers, which for a long time remained the only category of low-cost GNSS receivers, often limited by their level of accuracy (metric) mainly due to their single-frequency nature, have been joined in the last decade by dual-frequency GNSS receivers developed by certain manufacturers of positioning equipment. These receivers now offer possible alternatives to the relatively expensive conventional (topographic quality) or geodetic receivers and. In this study, the performance of these low-cost dual-frequency receivers was evaluated in static and real-time kinematic GNSS positioning modes. Static positioning was carried out on three points with sessions of 2 h and 4 h over three days with antenna swapping (CHC i50, Leica GS14 and Emlid Reach RS2+). Real-time observations were carried out on eleven (11) points in open, poorly open and not at all open environments, in order to assess not only performance but also receiver sensitivity in environments with a high risk of multipath. The results obtained showed an average agreement of 2 cm in planimetry between the low-cost Emlid RS2+ receiver and the Leica GS14 and CHC i50 receivers. The differences in altimetry are nevertheless greater (sometimes up to decimetres for certain points). Real-time positioning results provided an average convergence of around 1 cm on the E, N and H components with the results from the low-cost Emlid Reach RS2+ and Ublox ZED-F9P receivers and the CHC i50 receiver. Analysis of the results obtained has enabled us to highlight the various issues and challenges associated with this new generation of GNSS receivers, with a view to enhancing their appropriation and optimal integration in the professional and research worlds.展开更多
Aiming at the problem that the positioning accuracy of WiFi indoor positioning technology based on location fingerprint has not reached the requirements of practical application, a WiFi indoor positioning and tracking...Aiming at the problem that the positioning accuracy of WiFi indoor positioning technology based on location fingerprint has not reached the requirements of practical application, a WiFi indoor positioning and tracking algorithm combining adaptive affine propagation (AAPC), compressed sensing (CS) and Kalman filter is proposed. In the off-line phase, AAPC algorithm is used to generate clustering fingerprints with optimal clustering effect performance;In the online phase, CS and nearest neighbor algorithm are used for position estimation;Finally, the Kalman filter and physical constraints are combined to perform positioning and tracking. By collecting a large number of real experimental data, it is proved that the developed algorithm has higher positioning accuracy and more accurate trajectory tracking effect.展开更多
基金National Natural Science Foundation of China(Grant No.62101138)Shandong Natural Science Foundation(Grant No.ZR2021QD148)+1 种基金Guangdong Natural Science Foundation(Grant No.2022A1515012573)Guangzhou Basic and Applied Basic Research Project(Grant No.202102020701)for providing funds for publishing this paper。
文摘As positioning sensors,edge computation power,and communication technologies continue to develop,a moving agent can now sense its surroundings and communicate with other agents.By receiving spatial information from both its environment and other agents,an agent can use various methods and sensor types to localize itself.With its high flexibility and robustness,collaborative positioning has become a widely used method in both military and civilian applications.This paper introduces the basic fundamental concepts and applications of collaborative positioning,and reviews recent progress in the field based on camera,LiDAR(Light Detection and Ranging),wireless sensor,and their integration.The paper compares the current methods with respect to their sensor type,summarizes their main paradigms,and analyzes their evaluation experiments.Finally,the paper discusses the main challenges and open issues that require further research.
文摘This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally invasive and effective technique for drainage in patients with acute cholecystitis with high risk of surgery.The procedure has demonstrated impressive technical and clinical success rates with low rates of adverse events,making it a safe and effective option for appropriate candidates.Furthermore,EUS-GBD can also serve as a rescue option for patients who have failed endoscopic retrograde cholangiopancreatography or EUS biliary drainage for relief of jaundice in malignant biliary stricture.However,patient selection is critical for the success of EUS-GBD,and proper patient selection and risk assessment are important to ensure the safety and efficacy of the procedure.As the field continues to evolve and mature,ongoing research will further refine our understanding of the benefits and limitations of EUS-GBD,ultimately leading to improved outcomes for patients.
基金the National Natural Science Foundation of China(Grant No.42271436)the Shandong Provincial Natural Science Foundation,China(Grant Nos.ZR2021MD030,ZR2021QD148).
文摘The existing indoor fusion positioning methods based on Pedestrian Dead Reckoning(PDR)and geomagnetic technology have the problems of large initial position error,low sensor accuracy,and geomagnetic mismatch.In this study,a novel indoor fusion positioning approach based on the improved particle filter algorithm by geomagnetic iterative matching is proposed,where Wi-Fi,PDR,and geomagnetic signals are integrated to improve indoor positioning performances.One important contribution is that geomagnetic iterative matching is firstly proposed based on the particle filter algorithm.During the positioning process,an iterative window and a constraint window are introduced to limit the particle generation range and the geomagnetic matching range respectively.The position is corrected several times based on geomagnetic iterative matching in the location correction stage when the pedestrian movement is detected,which made up for the shortage of only one time of geomagnetic correction in the existing particle filter algorithm.In addition,this study also proposes a real-time step detection algorithm based on multi-threshold constraints to judge whether pedestrians are moving,which satisfies the real-time requirement of our fusion positioning approach.Through experimental verification,the average positioning accuracy of the proposed approach reaches 1.59 m,which improves 33.2%compared with the existing particle filter fusion positioning algorithms.
文摘Background:To prevent stent migration during endoscopic ultrasound-guided hepaticogastrostomy(EUS-HGS),intra-scope channel release technique is important,but is unfamiliar to non-expert hands.The self-expandable metal stent(SEMS)is an additional factor to prevent stent migration.However,no compara-tive studies of laser-cut-type and braided-type during EUS-HGS have been reported.The aim of this study was to compare the distance between the intrahepatic bile duct and stomach wall after EUS-HGS among laser-cut-type and braided-type SEMS.Methods:To evaluate stent anchoring function,we measured the distance between the hepatic parenchyma and stomach wall before EUS-HGS,one day after EUS-HGS,and 7 days after EUS-HGS.Also,propensity score matching was performed to create a propensity score for using laser-cut-type group and braided-type group.Results:A total of 142 patients were enrolled in this study.Among them,24 patients underwent EUS-HGS using a laser-cut-type SEMS,and 118 patients underwent EUS-HGS using a braided-type SEMS.EUS-HGS using the laser-cut-type SEMS was mainly performed by non-expert endoscopists(n=21);EUS-HGS using braided-type SEMS was mainly performed by expert endoscopists(n=98).The distance after 1 day was significantly shorter in the laser-cut-type group than that in the braided-type group[2.00(1.70-3.75)vs.6.90(3.72-11.70)mm,P<0.001].In addition,this distance remained significantly shorter in the laser-cut-type group after 7 days.Although these results were similar after propensity score matching analysis,the distance between hepatic parenchyma and stomach after 7 days was increased by 4 mm compared with the distance after 1 day in the braided-type group.On the other hand,in the laser-cut-type group,the distance after 1 day and 7 days was almost the same.Conclusions:EUS-HGS using a laser-cut-type SEMS may be safe to prevent stent migration,even in non-expert hands.
文摘BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guided coaxial core needle biopsy(CNB)not only procures sufficient tissue to help clarify the diagnosis,but reduces the incidence of puncture-related complications.CASE SUMMARY A 41-year-old female,with a history of pulmonary tuberculosis,was admitted to our hospital with multiple indeterminate splenic lesions.Gray-scale ultrasono-graphy demonstrated splenomegaly with numerous well-defined hypoechoic ma-sses.Abdominal contrast-enhanced computed tomography(CT)showed an en-larged spleen with multiple irregular-shaped,peripherally enhancing,hypodense lesions.Positron emission CT revealed numerous abnormal hyperglycemia foci.These imaging findings strongly indicated the possibility of infectious disease as the primary concern,with neoplastic lesions requiring exclusion.To obtain the precise pathological diagnosis,the US-guided coaxial CNB of the spleen was ca-rried out.The patient did not express any discomfort during the procedure.CONCLUSION Percutaneous US-guided coaxial CNB is an excellent and safe option for obtaining precise splenic tissue samples,as it significantly enhances sample yield for exact pathological analysis with minimum trauma to the spleen parenchyma and sur-rounding tissue.
文摘BACKGROUND Pancreatic ductal leaks complicated by endoscopic ultrasonography-guided tissue sampling(EUS-TS)can manifest as acute pancreatitis.CASE SUMMARY A 63-year-old man presented with persistent abdominal pain and weight loss.Diagnosis:Laboratory findings revealed elevated carbohydrate antigen 19-9(5920 U/mL)and carcinoembryonic antigen(23.7 ng/mL)levels.Magnetic resonance imaging of the pancreas revealed an approximately 3 cm ill-defined space-occupying lesion in the inferior aspect of the head,with severe encasement of the superior mesenteric artery.Pancreatic ductal adenocarcinoma was confirmed after pathological examination of specimens obtained by EUS-TS using the fanning method.Interventions and outcomes:The following day,the patient experienced severe abdominal pain with high amylase(265 U/L)and lipase(1173 U/L)levels.Computed tomography of the abdomen revealed edematous wall thickening of the second portion of the duodenum with adjacent fluid collections and a suspicious leak from either the distal common bile duct or the main pancreatic duct in the head.Endoscopic retrograde cholangiopancreatography revealed dye leakage in the head of the main pancreatic duct.Therefore,a 5F 7 cm linear plastic stent was deployed into the pancreatic duct to divert the pancreatic juice.The patient’s abdominal pain improved immediately after pancreatic stent insertion,and amylase and lipase levels normalized within a week.Neoadjuvant chemotherapy was then initiated.CONCLUSION Using the fanning method in EUS-TS can inadvertently cause damage to the pancreatic duct and may lead to clinically significant pancreatitis.Placing a pancreatic stent may immediately resolve acute pancreatitis and shorten the waiting time for curative therapy.When using the fanning method during EUSTS,ductal structures should be excluded to prevent pancreatic ductal leakage.
基金the National Natural Science Fund of China(61471080)Training Plan for Young Backbone Teachers in Colleges and Universities of Henan Province(2018GGJS171).
文摘To solve the problem of data fusion for prior information such as track information and train status in train positioning,an adaptive H∞filtering algorithm with combination constraint is proposed,which fuses prior information with other sensor information in the form of constraints.Firstly,the train precise track constraint method of the train is proposed,and the plane position constraint and train motion state constraints are analysed.A model for combining prior information with constraints is established.Then an adaptive H∞filter with combination constraints is derived based on the adaptive adjustment method of the robustness factor.Finally,the positioning effect of the proposed algorithm is simulated and analysed under the conditions of a straight track and a curved track.The results show that the positioning accuracy of the algorithm with constrained filtering is significantly better than that of the algorithm without constrained filtering and that the algorithm with constrained filtering can achieve better performance when combined with track and condition information,which can significantly reduce the train positioning error.The effectiveness of the proposed algorithm is verified.
文摘Accurate positioning is one of the essential requirements for numerous applications of remote sensing data,especially in the event of a noisy or unreliable satellite signal.Toward this end,we present a novel framework for aircraft geo-localization in a large range that only requires a downward-facing monocular camera,an altimeter,a compass,and an open-source Vector Map(VMAP).The algorithm combines the matching and particle filter methods.Shape vector and correlation between two building contour vectors are defined,and a coarse-to-fine building vector matching(CFBVM)method is proposed in the matching stage,for which the original matching results are described by the Gaussian mixture model(GMM).Subsequently,an improved resampling strategy is designed to reduce computing expenses with a huge number of initial particles,and a credibility indicator is designed to avoid location mistakes in the particle filter stage.An experimental evaluation of the approach based on flight data is provided.On a flight at a height of 0.2 km over a flight distance of 2 km,the aircraft is geo-localized in a reference map of 11,025 km~2using 0.09 km~2aerial images without any prior information.The absolute localization error is less than 10 m.
文摘Pancreatic fluid collections(PFCs)result from injury to the pancreas from acute or chronic pancreatitis,surgery,or trauma.Management of these collections has evolved over the last 2 decades.The choice of interventions includes percu-taneous,endoscopic,minimally invasive surgery,or a combined approach.Endoscopic drainage is the drainage of PFCs by creating an artificial communication between the collection and gastrointestinal lumen that is maintained by placing a stent across the fistulous tract.In this editorial,we endeavored to update the current status of endoscopic ultrasound-guided drainage of PFCs.
基金supported by the Key Project of Guizhou Science and Technology Support Program,Guizhou Key Science and Support[2021]-001supported by the Key Laboratory of Cognitive Radio and Information Processing,Ministry of Education(Guilin University of Electronic Technology)(CRKL220203)+2 种基金Key Laboratory of Middle Atmosphere and Global Environment Observation(LAGEO)Institute of Atmospheric Physics,Chinese Academy of Sciences(LAGEO-2022-02)Henan Province Key R&D and Promotion Special Project(No.212102210166)“Double First-Class”Discipline Creation Project of Surveying Science and Technology(GCCRC202306).
文摘The development of the fifth-generation(5G)mobile communication systems has entered the commercialization stage.5G has a high data rate,low latency,and high reliability that can meet the basic demands of most industries and daily life,such as the Internet of Things(IoT),intelligent transportation systems,positioning,and navigation.The continuous progress and development of society have aroused wide concern.Positioning accuracy is the core demand for the applications,especially in complex environments such as airports,warehouses,supermarkets,and basements.However,many factors also affect the accuracy of positioning in those environments,for example,multipath effects,non-line-of-sight,and clock synchronization errors.This paper provides a comprehensive review of the existing works about positioning for the future wireless network and discusses its key techniques and algorithms,as well as the current development and future directions.We first outline the current traditional positioning technologies and algorithms,which are discussed and analyzed with the relevant literature.In addition,we also discuss application scenarios for wireless localization.By comparing different positioning systems,the challenges and future development directions of existing wireless positioning systems are prospected.
基金supported in part by the National Science Fund for Excellent Young Scholars(No.62222113)in part by the joint Funds of the National Natural Science Foundation of China(No.U22B2015)+1 种基金in part by the stabilization support of National Radar Signal Processing Laboratory(No.KGJ202203)in part by the Fundamental Research Funds for the Central Universities(No.ZDRC2004).
文摘Obtaining precise position of interested emitters passively has wide applications in both civilian and military fields.Different from traditional parameter measurement and direct position determination(DPD)method,recently a new passive localization method based on synthetic aper-ture technique,named synthetic aperture positioning(SAP),has been proposed.The method com-pensates for the nonlinear phase produced by relative motion between the moving platform and the emitter,achieving coherent summation of intercepted signals.The SAP can obtain high-resolution and high-precision localization results at a low signal-to-noise ratio.This paper summarizes the research progress of SAP,including localization principles,spaceborne applications,and application scope analysis.Besides,the possible future outlook of SAP is considered.
基金supported by the National Natural Science Foundation of China under(Grant No.52175531)in part by the Science and Technology Research Program of Chongqing Municipal Education Commission under Grant(Grant Nos.KJQN202000605 and KJZD-M202000602)。
文摘Pedestrian positioning system(PPS)using wearable inertial sensors has wide applications towards various emerging fields such as smart healthcare,emergency rescue,soldier positioning,etc.The performance of traditional PPS is limited by the cumulative error of inertial sensors,complex motion modes of pedestrians,and the low robustness of the multi-sensor collaboration structure.This paper presents a hybrid pedestrian positioning system using the combination of wearable inertial sensors and ultrasonic ranging(H-PPS).A robust two nodes integration structure is developed to adaptively combine the motion data acquired from the single waist-mounted and foot-mounted node,and enhanced by a novel ellipsoid constraint model.In addition,a deep-learning-based walking speed estimator is proposed by considering all the motion features provided by different nodes,which effectively reduces the cumulative error originating from inertial sensors.Finally,a comprehensive data and model dual-driven model is presented to effectively combine the motion data provided by different sensor nodes and walking speed estimator,and multi-level constraints are extracted to further improve the performance of the overall system.Experimental results indicate that the proposed H-PPS significantly improves the performance of the single PPS and outperforms existing algorithms in accuracy index under complex indoor scenarios.
文摘BACKGROUND Malignant obstructive jaundice(MOJ)is a condition characterized by varying degrees of bile duct stenosis and obstruction,accompanied by the progressive development of malignant tumors,leading to high morbidity and mortality rates.Currently,the two most commonly employed methods for its management are percutaneous transhepatic bile duct drainage(PTBD)and endoscopic ultrasound-guided biliary drainage(EUS-BD).While both methods have demonstrated favorable outcomes,additional research needs to be performed to determine their relative efficacy.To compare the therapeutic effectiveness of EUS-BD and PTBD in treating MOJ.METHODS This retrospective analysis,conducted between September 2015 and April 2023 at The Third Affiliated Hospital of Soochow University(The First People’s Hospital of Changzhou),involved 68 patients with MOJ.The patients were divided into two groups on the basis of surgical procedure received:EUS-BD subgroup(n=33)and PTBD subgroup(n=35).Variables such as general data,preoperative and postoperative indices,blood routine,liver function indices,myocardial function indices,operative success rate,clinical effectiveness,and complication rate were analyzed and compared between the subgroups.RESULTS In the EUS-BD subgroup,hospital stay duration,bile drainage volume,effective catheter time,and clinical effect-iveness rate were superior to those in the PTBD subgroup,although the differences were not statistically significant(P>0.05).The puncture time for the EUS-BD subgroup was shorter than that for the PTBD subgroup(P<0.05).Postoperative blood routine,liver function index,and myocardial function index in the EUS-BD subgroup were significantly lower than those in the PTBD subgroup(P<0.05).Additionally,the complication rate in the EUS-BD subgroup was lower than in the PTBD subgroup(P<0.05).CONCLUSION EUS-BD may reduce the number of punctures,improve liver and myocardial functions,alleviate traumatic stress,and decrease complication rates in MOJ treatment.
基金This work was supported by the National Natural Science Foundation of China(61903086,61903366,62001115)the Natural Science Foundation of Hunan Province(2019JJ50745,2020JJ4280,2021JJ40133)the Fundamentals and Basic of Applications Research Foundation of Guangdong Province(2019A1515110136).
文摘The observation error model of the underwater acous-tic positioning system is an important factor to influence the positioning accuracy of the underwater target.For the position inconsistency error caused by considering the underwater tar-get as a mass point,as well as the observation system error,the traditional error model best estimation trajectory(EMBET)with little observed data and too many parameters can lead to the ill-condition of the parameter model.In this paper,a multi-station fusion system error model based on the optimal polynomial con-straint is constructed,and the corresponding observation sys-tem error identification based on improved spectral clustering is designed.Firstly,the reduced parameter unified modeling for the underwater target position parameters and the system error is achieved through the polynomial optimization.Then a multi-sta-tion non-oriented graph network is established,which can address the problem of the inaccurate identification for the sys-tem errors.Moreover,the similarity matrix of the spectral cluster-ing is improved,and the iterative identification for the system errors based on the improved spectral clustering is proposed.Finally,the comprehensive measured data of long baseline lake test and sea test show that the proposed method can accu-rately identify the system errors,and moreover can improve the positioning accuracy for the underwater target positioning.
文摘In this paper,an antenna array composed of circular array and orthogonal linear array is proposed by using the design of long and short baseline“orthogonal linear array”and the circular array ambiguity resolution design of multi-group baseline clustering.The effectiveness of the antenna array in this paper is verified by sufficient simulation and experiment.After the system deviation correction work,it is found that in the L/S/C/X frequency bands,the ambiguity resolution probability is high,and the phase difference system error between each channel is basically the same.The angle measurement error is less than 0.5°,and the positioning error is less than 2.5 km.Notably,as the center frequency increases,calibration consistency improves,and the calibration frequency points become applicable over a wider frequency range.At a center frequency of 11.5 GHz,the calibration frequency point bandwidth extends to 1200 MHz.This combined antenna array deployment holds significant promise for a wide range of applications in contemporary wireless communication systems.
文摘In patients with liver tumors,the histopathology examination can assist in diagnosis,staging,prognosis,and therapeutic management strategy.Endoscopic ultrasound(EUS)-guided tissue acquisition using fine needle aspiration(FNA)or more newly fine needle biopsy(FNB)is a well-developed technique in order to evaluate and differentiate the liver masses.The goal of the EUS-FNA or EUS-FNB is to provide an accurate sample for a histopathology examination.Therefore,malignant tumors such as hepatocarcinoma,cholangiocarcinoma and liver metastasis or benign tumors such as liver adenoma,focal hyperplastic nodular tumors and cystic lesions can be accurately diagnosed using EUS-guided tissue acquisition.EUS-FNB using 19 or 22 Ga needle provide longer samples and a higher diagnostic accuracy in patients with liver masses when compared with EUS-FNA.Few data are available on the diagnostic accuracy of EUS-FNB when compared with percutaneously,ultrasound,computer tomography or transjugulary-guided liver biopsies.This review will discuss the EUS-guided tissue acquisition options in patients with liver tumors and its efficacy and safety in providing accurate samples.The results of the last studies comparing EUS-guided liver biopsy with other conventional techniques are presented.The EUS-guided tissue acquisition using FNB can be a suitable technique in suspected liver lesions in order to provide an accurate histopathology diagnosis,especially for those who require endoscopy.
基金supported by the special funds of Laoshan Laboratory(No.LSKJ202203604)the National Key Research and Development Program of China(No.2016 YFC0303901).
文摘The near-seabed multichannel seismic exploration systems have yielded remarkable successes in marine geological disaster assessment,marine gas hydrate investigation,and deep-sea mineral exploration owing to their high vertical and horizontal resolution.However,the quality of deep-towed seismic imaging hinges on accurate source-receiver positioning information.In light of existing technical problems,we propose a novel array geometry inversion method tailored for high-resolution deep-towed multichannel seismic exploration systems.This method is independent of the attitude and depth sensors along a deep-towed seismic streamer,accounting for variations in seawater velocity and seabed slope angle.Our approach decomposes the towed line array into multiline segments and characterizes its geometric shape using the line segment distance and pitch angle.Introducing optimization parameters for seawater velocity and seabed slope angle,we establish an objective function based on the model,yielding results that align with objective reality.Employing the particle swarm optimization algorithm enables synchronous acquisition of optimized inversion results for array geometry and seawater velocity.Experimental validation using theoretical models and practical data verifies that our approach effectively enhances source and receiver positioning inversion accuracy.The algorithm exhibits robust stability and reliability,addressing uncertainties in seismic traveltime picking and complex seabed topography conditions.
基金the Natural Science Foundation of Shandong Province of China(No.ZR2022MA051)the China Postdoctoral Science Foundation(No.2020M670891)the SDUST Research Fund(No.2019TDJH103)。
文摘The inhomogeneous sound speed in seawater causes refraction of sound waves,and the elimination of the refraction effect is essential to the accuracy of underwater acoustic positioning.The raytracing method is an indispensable tool for effectively handling problems.However,this method has a conflict between localization accuracy and computational quantity.The equivalent sound speed profile(ESSP)method uses a simple sound speed profile(SSP)instead of the actual complex SSP,which can improve positioning precision but with residual error.The residual error is especially non-negligible in deep water and at large beam incidence angles.By analyzing the residual error of the ESSP method through a simulation,an empirical formula of error is presented.The data collected in the sailing circle mode(large incidence angle)of the South China Sea are used for verification.The experiments show that compared to the ESSP method,the improved algorithm has higher positioning precision and is more efficient than the ray-tracing method.
文摘The development of this technology has favored the advances noted in recent years in the field of precise positioning. It has also paved the way for a wide range of research into the evaluation of their performance and reliability, their potential use in different fields, the improvement of performance and combined systems, etc. Single-frequency GNSS receivers, which for a long time remained the only category of low-cost GNSS receivers, often limited by their level of accuracy (metric) mainly due to their single-frequency nature, have been joined in the last decade by dual-frequency GNSS receivers developed by certain manufacturers of positioning equipment. These receivers now offer possible alternatives to the relatively expensive conventional (topographic quality) or geodetic receivers and. In this study, the performance of these low-cost dual-frequency receivers was evaluated in static and real-time kinematic GNSS positioning modes. Static positioning was carried out on three points with sessions of 2 h and 4 h over three days with antenna swapping (CHC i50, Leica GS14 and Emlid Reach RS2+). Real-time observations were carried out on eleven (11) points in open, poorly open and not at all open environments, in order to assess not only performance but also receiver sensitivity in environments with a high risk of multipath. The results obtained showed an average agreement of 2 cm in planimetry between the low-cost Emlid RS2+ receiver and the Leica GS14 and CHC i50 receivers. The differences in altimetry are nevertheless greater (sometimes up to decimetres for certain points). Real-time positioning results provided an average convergence of around 1 cm on the E, N and H components with the results from the low-cost Emlid Reach RS2+ and Ublox ZED-F9P receivers and the CHC i50 receiver. Analysis of the results obtained has enabled us to highlight the various issues and challenges associated with this new generation of GNSS receivers, with a view to enhancing their appropriation and optimal integration in the professional and research worlds.
文摘Aiming at the problem that the positioning accuracy of WiFi indoor positioning technology based on location fingerprint has not reached the requirements of practical application, a WiFi indoor positioning and tracking algorithm combining adaptive affine propagation (AAPC), compressed sensing (CS) and Kalman filter is proposed. In the off-line phase, AAPC algorithm is used to generate clustering fingerprints with optimal clustering effect performance;In the online phase, CS and nearest neighbor algorithm are used for position estimation;Finally, the Kalman filter and physical constraints are combined to perform positioning and tracking. By collecting a large number of real experimental data, it is proved that the developed algorithm has higher positioning accuracy and more accurate trajectory tracking effect.