This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power osci...This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power oscillations and current distortions are inevitable.In the proposed strategy,the extended power theory is introduced to compute the power feedbacks together with the classical power theory.Based on the combination of the classical and extended power theory,the proposed strategy can achieve the sinusoidal current provision and the flexible regulation between three common targets,i.e.,constant active power,balanced current,and constant reactive power.Meanwhile,the proposed strategy is associated with a power limiter,which is capable to keep the currents under the pre-defined threshold and to compute the maximum apparent power for better utilization of the inverter capacity.With this power limiter,the rated inverter capacity is fully used for both the active and reactive power provisions under unbalanced grid faults.Using the proposed power regulation and limitation,the VSI can avoid overcurrent tripping and flexibly regulate its power under unbalanced grid faults.All the conclusions are verified by the real-time hardware-in-loop tests.展开更多
The doubly-fed induction generator(DFIG)is considered to provide a low-reactance path in the negative-sequence system and naturally comply with requirements on the negative-sequence reactive current in emerging grid c...The doubly-fed induction generator(DFIG)is considered to provide a low-reactance path in the negative-sequence system and naturally comply with requirements on the negative-sequence reactive current in emerging grid codes.This paper shows otherwise and how the control strategy of converters plays a key role in the formation of the active and reactive current components.After investigating the existing control strategies from the perspective of grid code compliance and showing how they fail in addressing emerging requirements on the negative-sequence reactive current,we propose a new coordinated control strategy that complies with reactive current requirements in grid codes in the positive-and negative-sequence systems.The proposed method fully takes advantage of the current and voltage capacities of both the rotor-side converter(RSC)and grid-side converter(GSC),which enables the grid code compliance of the DFIG under unbalanced three-phase voltages due to asymmetrical faults.The mathematical investigations and proposed strategy are validated with detailed simulation models using the Electric Power Research Institute(EPRI)benchmark system.The derived mathematical expressions provide analytical clarifications on the response of the DFIG in the negative-sequence system from the grid perspective.展开更多
This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square(RMS)phasor-domain,fundamentalfrequency,three-phase,and dynamic simulation tools....This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square(RMS)phasor-domain,fundamentalfrequency,three-phase,and dynamic simulation tools.The effectiveness of the proposed controller is assessed with simulations in test systems with high percentage of converter-interfaced generation.The simulations focus on the operation of protection relays that use negative-sequence quantities in their directional elements.This paper also presents and compares two strategies to limit reactive negative-sequence currents,and active and reactive positive-sequence currents.A tutorial test system and a regional system part of the actual Brazilian Interconnected Power System are used to assess the correctness of the proposed controller in three-phase fundamental-frequency RMS dynamic simulations.展开更多
基金This work is supported by the National Key Research and Development Program of China under Project 2021YFB2601600。
文摘This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power oscillations and current distortions are inevitable.In the proposed strategy,the extended power theory is introduced to compute the power feedbacks together with the classical power theory.Based on the combination of the classical and extended power theory,the proposed strategy can achieve the sinusoidal current provision and the flexible regulation between three common targets,i.e.,constant active power,balanced current,and constant reactive power.Meanwhile,the proposed strategy is associated with a power limiter,which is capable to keep the currents under the pre-defined threshold and to compute the maximum apparent power for better utilization of the inverter capacity.With this power limiter,the rated inverter capacity is fully used for both the active and reactive power provisions under unbalanced grid faults.Using the proposed power regulation and limitation,the VSI can avoid overcurrent tripping and flexibly regulate its power under unbalanced grid faults.All the conclusions are verified by the real-time hardware-in-loop tests.
文摘The doubly-fed induction generator(DFIG)is considered to provide a low-reactance path in the negative-sequence system and naturally comply with requirements on the negative-sequence reactive current in emerging grid codes.This paper shows otherwise and how the control strategy of converters plays a key role in the formation of the active and reactive current components.After investigating the existing control strategies from the perspective of grid code compliance and showing how they fail in addressing emerging requirements on the negative-sequence reactive current,we propose a new coordinated control strategy that complies with reactive current requirements in grid codes in the positive-and negative-sequence systems.The proposed method fully takes advantage of the current and voltage capacities of both the rotor-side converter(RSC)and grid-side converter(GSC),which enables the grid code compliance of the DFIG under unbalanced three-phase voltages due to asymmetrical faults.The mathematical investigations and proposed strategy are validated with detailed simulation models using the Electric Power Research Institute(EPRI)benchmark system.The derived mathematical expressions provide analytical clarifications on the response of the DFIG in the negative-sequence system from the grid perspective.
基金supported by CNPQ,FAPERJ and Coordenacao de Aperfeicoamento de Pessoal de Nível Superior–Brasil(CAPES)Finance Code 001。
文摘This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square(RMS)phasor-domain,fundamentalfrequency,three-phase,and dynamic simulation tools.The effectiveness of the proposed controller is assessed with simulations in test systems with high percentage of converter-interfaced generation.The simulations focus on the operation of protection relays that use negative-sequence quantities in their directional elements.This paper also presents and compares two strategies to limit reactive negative-sequence currents,and active and reactive positive-sequence currents.A tutorial test system and a regional system part of the actual Brazilian Interconnected Power System are used to assess the correctness of the proposed controller in three-phase fundamental-frequency RMS dynamic simulations.