期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Flexible Power Regulation and Limitation of Voltage Source Inverters under Unbalanced Grid Faults 被引量:2
1
作者 Peng Cheng Kongyuan Li +2 位作者 Chao Wu Jing Ma Limin Jia 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第2期153-161,共9页
This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power osci... This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power oscillations and current distortions are inevitable.In the proposed strategy,the extended power theory is introduced to compute the power feedbacks together with the classical power theory.Based on the combination of the classical and extended power theory,the proposed strategy can achieve the sinusoidal current provision and the flexible regulation between three common targets,i.e.,constant active power,balanced current,and constant reactive power.Meanwhile,the proposed strategy is associated with a power limiter,which is capable to keep the currents under the pre-defined threshold and to compute the maximum apparent power for better utilization of the inverter capacity.With this power limiter,the rated inverter capacity is fully used for both the active and reactive power provisions under unbalanced grid faults.Using the proposed power regulation and limitation,the VSI can avoid overcurrent tripping and flexibly regulate its power under unbalanced grid faults.All the conclusions are verified by the real-time hardware-in-loop tests. 展开更多
关键词 Flexible power regulation Power limiter Voltage source inverter unbalanced faults
下载PDF
Coordinated Control of DFIG Converters to Comply with Reactive Current Requirements in Emerging Grid Codes 被引量:1
2
作者 Yuanzhu Chang Ilhan Kocar +3 位作者 Jiabing Hu Ulas Karaagac Ka Wing Chan Jean Mahseredjian 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第2期502-514,共13页
The doubly-fed induction generator(DFIG)is considered to provide a low-reactance path in the negative-sequence system and naturally comply with requirements on the negative-sequence reactive current in emerging grid c... The doubly-fed induction generator(DFIG)is considered to provide a low-reactance path in the negative-sequence system and naturally comply with requirements on the negative-sequence reactive current in emerging grid codes.This paper shows otherwise and how the control strategy of converters plays a key role in the formation of the active and reactive current components.After investigating the existing control strategies from the perspective of grid code compliance and showing how they fail in addressing emerging requirements on the negative-sequence reactive current,we propose a new coordinated control strategy that complies with reactive current requirements in grid codes in the positive-and negative-sequence systems.The proposed method fully takes advantage of the current and voltage capacities of both the rotor-side converter(RSC)and grid-side converter(GSC),which enables the grid code compliance of the DFIG under unbalanced three-phase voltages due to asymmetrical faults.The mathematical investigations and proposed strategy are validated with detailed simulation models using the Electric Power Research Institute(EPRI)benchmark system.The derived mathematical expressions provide analytical clarifications on the response of the DFIG in the negative-sequence system from the grid perspective. 展开更多
关键词 Doubly-fed induction generator(DFIG) negative sequence short circuit wind turbine generator reactive current space vector unbalanced fault phase lock loop(PLL).
原文传递
Phasor-domain Dynamic Model of Asymmetric Current Injection Controller for Converter-interfaced Generator
3
作者 Victor A.F.Almeida Glauco N.Taranto José M.T.Marinho 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第6期1269-1278,共10页
This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square(RMS)phasor-domain,fundamentalfrequency,three-phase,and dynamic simulation tools.... This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square(RMS)phasor-domain,fundamentalfrequency,three-phase,and dynamic simulation tools.The effectiveness of the proposed controller is assessed with simulations in test systems with high percentage of converter-interfaced generation.The simulations focus on the operation of protection relays that use negative-sequence quantities in their directional elements.This paper also presents and compares two strategies to limit reactive negative-sequence currents,and active and reactive positive-sequence currents.A tutorial test system and a regional system part of the actual Brazilian Interconnected Power System are used to assess the correctness of the proposed controller in three-phase fundamental-frequency RMS dynamic simulations. 展开更多
关键词 Converter-interfaced generator three-phase model power system protection negative-sequence current injection negative-sequence current protection unbalanced fault three-phase root-mean-square(RMS)dynamic simulation
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部