Purpose: To summarize the clinical experience of 300 cases using the Sapphire unfloder intraocular lens (IOL) injection system.Methods: After the standard phacoemulsification, an AR40e IOL was implanted using the Sapp...Purpose: To summarize the clinical experience of 300 cases using the Sapphire unfloder intraocular lens (IOL) injection system.Methods: After the standard phacoemulsification, an AR40e IOL was implanted using the Sapphire Unfolder. The involved problems during and after the operation were observed and analyzed.Results:The complications occurred during the operation including the crack at the haptic-optic junction in 2 cases, slight kink in the haptic in 5 cases, IOL clamp into the cartridge in 2 cases, posterior capsular rupture in 2 cases and endothelium damage in the central small area in 4 cases. All the patients recovered successfully with IOLs in good position.Conclusion: IOL implantation with the Sapphire Unfolder led to no serious complications and got the satisfactory results.展开更多
Objective: To evaluate the clinical results of implantation of foldable intraocular lens inmultiple types of cataract.Methods: This retrospective study comprised 162 eyes of 148 patients undergoingphacoemulsification ...Objective: To evaluate the clinical results of implantation of foldable intraocular lens inmultiple types of cataract.Methods: This retrospective study comprised 162 eyes of 148 patients undergoingphacoemulsification and implantation of foldable intraocular lens, some of whom under-went combined pars plana vitrectomy or trabeculectomy or silicone oil removal. Theperiod of follow-up was from 3 months to 17 months.Results: There is slight reaction postoperatively in all cases. The postoperative uncorrectedvisual acuites was from 0. 05 to 1.2, patient with 0.6 or above acuity were 70.98%. Aneodymium: YAG capsulotomy was required in 5 eyes. Posterior capsule ruptured in 1eyes, and a PMMA intraocular lens was implanted in ciliary sulcus. In one eye, a lenswas removed because of recurrence of retina detachment.Conclusions: The application of foldable intraocular lens in multiple types of cataract issafe, and there is a slight postoperative reaction. less complications , and fast visualacuity recovery.展开更多
文摘Purpose: To summarize the clinical experience of 300 cases using the Sapphire unfloder intraocular lens (IOL) injection system.Methods: After the standard phacoemulsification, an AR40e IOL was implanted using the Sapphire Unfolder. The involved problems during and after the operation were observed and analyzed.Results:The complications occurred during the operation including the crack at the haptic-optic junction in 2 cases, slight kink in the haptic in 5 cases, IOL clamp into the cartridge in 2 cases, posterior capsular rupture in 2 cases and endothelium damage in the central small area in 4 cases. All the patients recovered successfully with IOLs in good position.Conclusion: IOL implantation with the Sapphire Unfolder led to no serious complications and got the satisfactory results.
文摘Objective: To evaluate the clinical results of implantation of foldable intraocular lens inmultiple types of cataract.Methods: This retrospective study comprised 162 eyes of 148 patients undergoingphacoemulsification and implantation of foldable intraocular lens, some of whom under-went combined pars plana vitrectomy or trabeculectomy or silicone oil removal. Theperiod of follow-up was from 3 months to 17 months.Results: There is slight reaction postoperatively in all cases. The postoperative uncorrectedvisual acuites was from 0. 05 to 1.2, patient with 0.6 or above acuity were 70.98%. Aneodymium: YAG capsulotomy was required in 5 eyes. Posterior capsule ruptured in 1eyes, and a PMMA intraocular lens was implanted in ciliary sulcus. In one eye, a lenswas removed because of recurrence of retina detachment.Conclusions: The application of foldable intraocular lens in multiple types of cataract issafe, and there is a slight postoperative reaction. less complications , and fast visualacuity recovery.