期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Conventional endoscopic retrograde cholangiopancreaticography vs the Olympus V-scope system 被引量:1
1
作者 Martin Raithel Andreas Ngel +5 位作者 Jürgen Maiss Dane Wildner Alexander Fritzkarl Hagel Sandra Braun Hiwot Diebel Eckhart Georg Hahn 《World Journal of Gastroenterology》 SCIE CAS 2013年第12期1936-1942,共7页
AIM: To compare the new Olympus V-scope (VS) to conventional endoscopic retrograde cholangiopancreati-cography (ERCP). METHODS: Forty-nine patients with previous endoscopic papillotomy who were admitted for interventi... AIM: To compare the new Olympus V-scope (VS) to conventional endoscopic retrograde cholangiopancreati-cography (ERCP). METHODS: Forty-nine patients with previous endoscopic papillotomy who were admitted for interventional ERCP for one of several reasons were included in this single-centre, prospective randomized study. Consecutive patients were randomized to either the VS group or to the conventional ERCP group. ERCP-nave patients who had not undergone papillotomy were excluded. The main study parameters were interventional examination time, X-ray time and dose, and premedication dose (all given below as the median, range) and were investigated in addition to each patient's clinical outcome and complications. Subjective scores to assess each procedure were also provided by the physicians and endoscopy assistants who carried out the procedures. A statistical analysis was carried out using the Wilcoxon rank-sum test.RESULTS: Twenty-five patients with 50 interventions were examined with the VS ERCP technique, and 24 patients with 47 interventions were examined using the conventional ERCP technique. There were no significant differences between the two groups regarding the age, sex, indications, degree of ERCP difficulty, or interventions performed. The main study parameters in the VS group showed a nonsignificant trend towards a shorter interventional examination time (29 min, 5-50 min vs 31 min, 7-90 min, P = 0.28), shorter X-ray time (5.8 min, 0.6-14.1 min vs 6.1 min, 1.6-18.8 min, P = 0.48), and lower X-ray dose (1351 cGy/m2 , 159-5039 cGy/m2 vs 1296 cGy/m2 , 202.2-6421 cGy/m 2 , P = 0.34). A nonsignificant trend towards fewer adverse events occurred in the VS group as compared with the conventional ERCP group (cholangitis: 12% vs 16%, P = 0.12; pain: 4% vs 12.5%, P = 0.33; post-ERCP pancreatitis: 4% vs 12.5%, P = 0.14). In addition, there were no statistically significant differences in assessment by the physicians and endoscopy assistants using subjective questionnaires.CONCLUSION: ERCP using the short-guidewire V-system did not significantly improve ERCP performance or patient outcomes, but it may reduce and simplify the ERCP procedure in difficult settings. 展开更多
关键词 ENDOSCOPIC RETROGRADE cholangiopancre-aticography Short GUIDEWIRE ENDOSCOPIC RETROGRADE cholangiopancreaticography SYSTEM X-ray protection v-scope Bile duct stenosis
下载PDF
“(V+O_1)+O_2”结构流行区域和原因新探 被引量:1
2
作者 陈艳阳 《惠州学院学报》 2008年第2期52-55,共4页
"(V+O1)+O2"(动宾组合+宾语)结构是20世纪80年代以后使用日渐增多的一种语法现象,它在其特定的流行区域里,因其独特的语用价值而得以存在、使用和广泛流行。
关键词 (V+O1)+O2 流行区域 语用价值
下载PDF
句域的对称性与动词补语并移假设
3
作者 程杰 《广东外语外贸大学学报》 2009年第6期38-42,共5页
"动词补语并移假设"能够统一地解释双宾结构和与格结构中句域的不对称现象,也能解释与格转移结构、外置结构和倒装结构中的句域对称现象。在这几类结构的推导过程中,Spec-VP位置的成分与VP-Comp位置的成分会构成两种结构关系... "动词补语并移假设"能够统一地解释双宾结构和与格结构中句域的不对称现象,也能解释与格转移结构、外置结构和倒装结构中的句域对称现象。在这几类结构的推导过程中,Spec-VP位置的成分与VP-Comp位置的成分会构成两种结构关系:在基础生成的结构中,前者单向成分统制后者;但在动词补语并移发生后,后者单向成分统制前者。因此,两个结构位置上的成分之辖域可能互相涵盖,产生对称现象。这种解释的可行性进一步表明了"动词补语并移假设"的合理性。 展开更多
关键词 动词补语并移 辖域 对称
下载PDF
应用全范围仿真机的核电站仪控软件设计验证 被引量:6
4
作者 孙远志 张洋 庞智 《计算机仿真》 CSCD 北大核心 2014年第4期147-150,272,共5页
核电站的安全特性要求数字化仪控系统软件必须具备极高的可靠性,但由于计算机软件的特殊性,要及时发现某些设计缺陷和逻辑错误,必须依赖特殊工况或人为的破坏性试验,这样做的代价是极高的。提供了一种验证方法,即基于核电站全范围仿真机... 核电站的安全特性要求数字化仪控系统软件必须具备极高的可靠性,但由于计算机软件的特殊性,要及时发现某些设计缺陷和逻辑错误,必须依赖特殊工况或人为的破坏性试验,这样做的代价是极高的。提供了一种验证方法,即基于核电站全范围仿真机,利用高精度的仿真模型,设计各种安全验证试验,通过模拟核电站的突发工况,验证仪控软件在这种突发工况下的安全性和可靠性;并在"数字化控制系统是不安全的"假设条件下,进行各项非常规操作,以验证仪控软件的逻辑和规程中的不安全因素。通过一个"汽机故障引发的非计划停堆事故"试验,找出了设计中可能存在的缺陷,并给出了改进意见。结果表明,基于全范围仿真机的仪控软件设计验证是可行的。 展开更多
关键词 数字化仪控系统 核电站全范围仿真机 软件验证
下载PDF
基于3KEYMASTER软件的核电站6.6kV系统仿真研究 被引量:6
5
作者 罗朋 刘鸿 +1 位作者 吴先荣 吴帆 《计算机时代》 2016年第4期6-8,共3页
核电站的全范围模拟机中电气系统数量庞大,系统数据接口之间的传输要保证实时准确。为了实现核电站中的6.6k V系统的准确仿真模拟,以阳江核电站为研究对象,通过在3KEYMASTER仿真平台上搭建与实际机组相一致的6.6k V系统,并添加了故障仿... 核电站的全范围模拟机中电气系统数量庞大,系统数据接口之间的传输要保证实时准确。为了实现核电站中的6.6k V系统的准确仿真模拟,以阳江核电站为研究对象,通过在3KEYMASTER仿真平台上搭建与实际机组相一致的6.6k V系统,并添加了故障仿真模型。研究表明,在3KEYMASTER仿真平台上搭建的6.6k V仿真系统能够满足设计要求。 展开更多
关键词 核电站 3KEYMASTER 6.6k V 全范围模拟机
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部