A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic ...A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic loading were tested to study the static behavior of this new type of joint.The main variable parameters for the five joint specimens were the longitudinal reinforcement ratio and the joint type.The experimental results designated that the magnitude of extension of the longitudinal reinforcement is the most important factor that influenced the moment-rotation characteristic of the new type of joint.The concrete slabs could resist 3.8%-19.1% of the total shear load applied to the cross-sections near the beam-to-column connection.The edge stiffened elements,such as the flange of the lipped I-section thin-walled steel beam,were capable of having considerable inelastic deformation capacity although they had comparatively large width-to-thickness ratios.The shear failure of the concrete cantilever edge strip must be taken into account in practical design because it has significant influence on the anchorage of the longitudinal reinforcement in the new type of external joints.展开更多
An experimental study on concrete filled steel tube columns with rectangular section subjected to compressionflexure-torsion combined action has been carried out. The failure modes and load-deformation hysteretic rela...An experimental study on concrete filled steel tube columns with rectangular section subjected to compressionflexure-torsion combined action has been carried out. The failure modes and load-deformation hysteretic relations were obtained. Based on the principles of classical material mechanics, the relations between the torsion curvature of the section and the shear strain of the fiber on the section were established. Then the strain distribution on the rectangular section of concrete filled steel tube columns subjected to torsion was analyzed. The three-dimensional refined finite element model was also built, in order to make the precision verification. The matrix forms of the relation between the torsion curvature of the section and the shear strain of the fiber on the section were derived, and introduced into the fiber beam model considering nonlinear torsion effect on the section. The comparison between test results and calculation results showed that the fiber beam model considering nonlinear torsion effect had high modeling efficiency and solution precision for predicting the torsion behavior of concrete filled steel tube columns with rectangular sections, and was suitable for analyzing the dynamic response of various structures subjected to the combined cyclic load caused by the earthquake load.展开更多
基金Sponsored by the National Natural Science Foundation of China (Grant No.50478027)
文摘A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic loading were tested to study the static behavior of this new type of joint.The main variable parameters for the five joint specimens were the longitudinal reinforcement ratio and the joint type.The experimental results designated that the magnitude of extension of the longitudinal reinforcement is the most important factor that influenced the moment-rotation characteristic of the new type of joint.The concrete slabs could resist 3.8%-19.1% of the total shear load applied to the cross-sections near the beam-to-column connection.The edge stiffened elements,such as the flange of the lipped I-section thin-walled steel beam,were capable of having considerable inelastic deformation capacity although they had comparatively large width-to-thickness ratios.The shear failure of the concrete cantilever edge strip must be taken into account in practical design because it has significant influence on the anchorage of the longitudinal reinforcement in the new type of external joints.
文摘An experimental study on concrete filled steel tube columns with rectangular section subjected to compressionflexure-torsion combined action has been carried out. The failure modes and load-deformation hysteretic relations were obtained. Based on the principles of classical material mechanics, the relations between the torsion curvature of the section and the shear strain of the fiber on the section were established. Then the strain distribution on the rectangular section of concrete filled steel tube columns subjected to torsion was analyzed. The three-dimensional refined finite element model was also built, in order to make the precision verification. The matrix forms of the relation between the torsion curvature of the section and the shear strain of the fiber on the section were derived, and introduced into the fiber beam model considering nonlinear torsion effect on the section. The comparison between test results and calculation results showed that the fiber beam model considering nonlinear torsion effect had high modeling efficiency and solution precision for predicting the torsion behavior of concrete filled steel tube columns with rectangular sections, and was suitable for analyzing the dynamic response of various structures subjected to the combined cyclic load caused by the earthquake load.