DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structu...DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structures upon the aerodynamic and acoustic performance, however they are only limited to the influence of a few parameters on the performance, and practical design of the unit requires more detailed parametric analysis. Three-dimensional computational fluid dynamics(CFD) and computational aerodynamic acoustics(CAA) simulation based on FLUENT solver is used to study the influence of surrounding structures upon the aforementioned properties of the unit. The flow rate and sound pressure level are predicted for different rotating speed, and agree well with the experimental results. The parametric influence of three main surrounding structures(i.e. the heat sink, the bell-mouth type shroud and the outlet grille) upon the aerodynamic performance of the unit is analyzed thoroughly. The results demonstrate that the tip vortex plays a major role in the flow fields near the blade tip and has a great effect on the flow field of the unit. The inlet ring's size and throat's depth of the bell-mouth type shroud, and the through-flow area and configuration of upwind and downwind sections of the outlet grille are the most important factors that affect the aerodynamic performance of the unit. Furthermore, two improved schemes against the existing prototype of the unit are developed, which both can significantly increase the flow rate more than 6 %(i.e. 100 m3·h~(-1)) at given rotating speeds. The inevitable increase of flow noise level when flow rate is increased and the advantage of keeping a lower rotating speed are also discussed. The presented work could be a useful guideline in designing the aerodynamic and acoustic performance of the split air-conditioner in engineering practice.展开更多
China is the largest producer and consumer of hydrochlorofluorocarbons (HCFCs), and the production of HCFC-22 accounts for more than 80% of all HCFCs. This paper concentrates on the residential air-conditioner indus...China is the largest producer and consumer of hydrochlorofluorocarbons (HCFCs), and the production of HCFC-22 accounts for more than 80% of all HCFCs. This paper concentrates on the residential air-conditioner industry and analyzes the environmental benefits of accelerating the phase-out of HCFC-22 in China. According to the comparison of the baseline and phase-out scenarios of HCFC-22, the findings show that using HC-290 (propane) as a refrigerant alternative will directly reduce the greenhouse effect, and indirectly reduce the emission of greenhouse gases due to a reduction in the electricity consumption. The comparison of two scenarios of HC-290 and HFC-410A refrigerant alternatives shows that the use of HC-290 refrigerant will produce significantly higher environmental benefits than the HFC-410A refrigerant.展开更多
HFC-134a is the most important alternative to CFC-12 used in the mobile air-conditioner sector in China. The con- sumption of HFC-134a has been increasing rapidly in recent years. It becomes the most consumed HFC in t...HFC-134a is the most important alternative to CFC-12 used in the mobile air-conditioner sector in China. The con- sumption of HFC-134a has been increasing rapidly in recent years. It becomes the most consumed HFC in the sector. Selecting 2005 as the base line year, future consumption and emission amounts of HFC-134a are estimated through an analysis of a combined scenario: 1) replacement by non-HFC-134a blends, 2) good practice in servicing, 3) technology promotion, and 4) government policies on control of HFC-134a emissions. The analysis shows that HFC-134a consumption and emissions will continue to increase in the next 10 years. The projected HFC-134a consumption will approach 20,150 t and 34,875 t in 2010 and 2015 respectively, while the estimated emission amounts will reach 16,065 t and 30,186 t (i.e., 21 Mt CO2-eq and 39 Mt CO2-eq emissions) correspondingly. Compared with the business-as-usual scenario, the expected emission reductions in 2010 and 2015 will range between 6.7 Mt CO2-eq and 13.0 Mt CO2-eq.展开更多
In order to expand the natural energy and the energy conservation, "the smart PV (photovoltaic power generation) & EV (electric vehicle) system" has been proposed and the effect has been clarified. In the smart...In order to expand the natural energy and the energy conservation, "the smart PV (photovoltaic power generation) & EV (electric vehicle) system" has been proposed and the effect has been clarified. In the smart PV & EV system, it is important that electric vehicles become popular. Therefore, the AI-EV (air-conditioner integrated electric vehicle) has been proposed. In this paper, the AI-EV is designed based on the required car air-conditioner capacity. And, the value of AI-EV is compared with a gasoline vehicle, HV (hybrid vehicle) and EV using the mathematical simulation model As a result, it is clarified that the minimum displacement of the small-engine is 120 cc for AI-EV. In the smart PV & EV system, AI-EV can reduce CO_2 emissions by 20% almost the same as EV. Additionally, AI-EV is able to gain the cruising range more than twice as long as EV.展开更多
Aim: To investigate the effect of air-conditioner exposure on semen quality. Methods: The data came from the healthy male volunteers, aged 22 to 30 years, who went to centers for maternity and children health for prem...Aim: To investigate the effect of air-conditioner exposure on semen quality. Methods: The data came from the healthy male volunteers, aged 22 to 30 years, who went to centers for maternity and children health for premarital physical examination in Shanghai, Henan, Zhejiang and Hebei from December 1998 to February 2000. The sampling size is 304. Results: Among the subjects, 90 (29.6 %) had air-conditioner at home and the rest did not. X2-test and multiple logistic regression analyses showed that, the difference between the exposure and control groups was statistically significant in semen volume, sperm density and proportion of sperm with normal morphology. The three indexes were lower in the exposure group. Conclusion: Air-conditioner exposure possibly influences the semen quality.展开更多
针对联盟链微电网电力交易场景的高吞吐量、高数据安全性及数据透明性的需求,提出一种在贡献值模型下的基于可验证随机函数(Verifiable Random Function,VRF)与基于BLS(Boneh-Lynn-Shacham Threshold Signatures,BLS)门限签名的改进实...针对联盟链微电网电力交易场景的高吞吐量、高数据安全性及数据透明性的需求,提出一种在贡献值模型下的基于可验证随机函数(Verifiable Random Function,VRF)与基于BLS(Boneh-Lynn-Shacham Threshold Signatures,BLS)门限签名的改进实用拜占庭容错共识算法(Contribution Value Model,Verifiable Random Function and Boneh-Lynn-Shacham Threshold Signatures Practical ByzantineFault Tolerance,CVB-PBFT)。CVB-PBFT算法通过贡献值模型筛选高贡献节点参与共识,采用VRF和安全随机函数选举不可预测的主节点,结合节点轮换和检测机制以及BLS签名优化通信流程,显著提高算法的性能和安全性。经实验证明,该算法能够有效防御恶意攻击,降低通信开销,并提升共识效率,满足微电网电力交易对时效性和安全性的要求。展开更多
基金Supported by Program for Changjiang Scholars and Innovative Research Team in University,Ministry of Education of China(PCSIRT)
文摘DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structures upon the aerodynamic and acoustic performance, however they are only limited to the influence of a few parameters on the performance, and practical design of the unit requires more detailed parametric analysis. Three-dimensional computational fluid dynamics(CFD) and computational aerodynamic acoustics(CAA) simulation based on FLUENT solver is used to study the influence of surrounding structures upon the aforementioned properties of the unit. The flow rate and sound pressure level are predicted for different rotating speed, and agree well with the experimental results. The parametric influence of three main surrounding structures(i.e. the heat sink, the bell-mouth type shroud and the outlet grille) upon the aerodynamic performance of the unit is analyzed thoroughly. The results demonstrate that the tip vortex plays a major role in the flow fields near the blade tip and has a great effect on the flow field of the unit. The inlet ring's size and throat's depth of the bell-mouth type shroud, and the through-flow area and configuration of upwind and downwind sections of the outlet grille are the most important factors that affect the aerodynamic performance of the unit. Furthermore, two improved schemes against the existing prototype of the unit are developed, which both can significantly increase the flow rate more than 6 %(i.e. 100 m3·h~(-1)) at given rotating speeds. The inevitable increase of flow noise level when flow rate is increased and the advantage of keeping a lower rotating speed are also discussed. The presented work could be a useful guideline in designing the aerodynamic and acoustic performance of the split air-conditioner in engineering practice.
文摘China is the largest producer and consumer of hydrochlorofluorocarbons (HCFCs), and the production of HCFC-22 accounts for more than 80% of all HCFCs. This paper concentrates on the residential air-conditioner industry and analyzes the environmental benefits of accelerating the phase-out of HCFC-22 in China. According to the comparison of the baseline and phase-out scenarios of HCFC-22, the findings show that using HC-290 (propane) as a refrigerant alternative will directly reduce the greenhouse effect, and indirectly reduce the emission of greenhouse gases due to a reduction in the electricity consumption. The comparison of two scenarios of HC-290 and HFC-410A refrigerant alternatives shows that the use of HC-290 refrigerant will produce significantly higher environmental benefits than the HFC-410A refrigerant.
文摘HFC-134a is the most important alternative to CFC-12 used in the mobile air-conditioner sector in China. The con- sumption of HFC-134a has been increasing rapidly in recent years. It becomes the most consumed HFC in the sector. Selecting 2005 as the base line year, future consumption and emission amounts of HFC-134a are estimated through an analysis of a combined scenario: 1) replacement by non-HFC-134a blends, 2) good practice in servicing, 3) technology promotion, and 4) government policies on control of HFC-134a emissions. The analysis shows that HFC-134a consumption and emissions will continue to increase in the next 10 years. The projected HFC-134a consumption will approach 20,150 t and 34,875 t in 2010 and 2015 respectively, while the estimated emission amounts will reach 16,065 t and 30,186 t (i.e., 21 Mt CO2-eq and 39 Mt CO2-eq emissions) correspondingly. Compared with the business-as-usual scenario, the expected emission reductions in 2010 and 2015 will range between 6.7 Mt CO2-eq and 13.0 Mt CO2-eq.
文摘In order to expand the natural energy and the energy conservation, "the smart PV (photovoltaic power generation) & EV (electric vehicle) system" has been proposed and the effect has been clarified. In the smart PV & EV system, it is important that electric vehicles become popular. Therefore, the AI-EV (air-conditioner integrated electric vehicle) has been proposed. In this paper, the AI-EV is designed based on the required car air-conditioner capacity. And, the value of AI-EV is compared with a gasoline vehicle, HV (hybrid vehicle) and EV using the mathematical simulation model As a result, it is clarified that the minimum displacement of the small-engine is 120 cc for AI-EV. In the smart PV & EV system, AI-EV can reduce CO_2 emissions by 20% almost the same as EV. Additionally, AI-EV is able to gain the cruising range more than twice as long as EV.
文摘Aim: To investigate the effect of air-conditioner exposure on semen quality. Methods: The data came from the healthy male volunteers, aged 22 to 30 years, who went to centers for maternity and children health for premarital physical examination in Shanghai, Henan, Zhejiang and Hebei from December 1998 to February 2000. The sampling size is 304. Results: Among the subjects, 90 (29.6 %) had air-conditioner at home and the rest did not. X2-test and multiple logistic regression analyses showed that, the difference between the exposure and control groups was statistically significant in semen volume, sperm density and proportion of sperm with normal morphology. The three indexes were lower in the exposure group. Conclusion: Air-conditioner exposure possibly influences the semen quality.
文摘针对联盟链微电网电力交易场景的高吞吐量、高数据安全性及数据透明性的需求,提出一种在贡献值模型下的基于可验证随机函数(Verifiable Random Function,VRF)与基于BLS(Boneh-Lynn-Shacham Threshold Signatures,BLS)门限签名的改进实用拜占庭容错共识算法(Contribution Value Model,Verifiable Random Function and Boneh-Lynn-Shacham Threshold Signatures Practical ByzantineFault Tolerance,CVB-PBFT)。CVB-PBFT算法通过贡献值模型筛选高贡献节点参与共识,采用VRF和安全随机函数选举不可预测的主节点,结合节点轮换和检测机制以及BLS签名优化通信流程,显著提高算法的性能和安全性。经实验证明,该算法能够有效防御恶意攻击,降低通信开销,并提升共识效率,满足微电网电力交易对时效性和安全性的要求。