In this study an indirect adaptive sliding mode control (SMC) based on a fuzzy logic scheme is proposed to strengthen the tracking control performance of a general class of multi-input multi-output (MIMO) nonlinear un...In this study an indirect adaptive sliding mode control (SMC) based on a fuzzy logic scheme is proposed to strengthen the tracking control performance of a general class of multi-input multi-output (MIMO) nonlinear uncertain systems. Combining reaching law approach and fuzzy universal approximation theorem, the proposed design procedure combines the advantages of fuzzy logic control, adaptive control and sliding mode control. The stability of the control systems is proved in the sense of the Lyapunov second stability theorem. Two simulation studies are presented to demonstrate the effectiveness of our new hybrid control algorithm.展开更多
Experiments were conducted to study the performance characters of aerobic/anoxic (A/ A) digestion of sludge at 30± 1 ℃, while the sludge retention time (SRT) was kept 16 d. The varia tions of oxidation redu...Experiments were conducted to study the performance characters of aerobic/anoxic (A/ A) digestion of sludge at 30± 1 ℃, while the sludge retention time (SRT) was kept 16 d. The varia tions of oxidation reduction potential (Eh ) and pH were continuously monitored during the A/A di gestion and the conversions of ammonium and nitrate were investigated. Important features on both Eh and pH profiles were identified to develop process control strategy. Since the feature point on Eh profile where d2 Eh/dt^2 =0 is very stable during anoxic cycle, it can be used to determine the end of denitrification. The end of nitrification can be identified according to dpH/dt = 0. A real-time control strategy of A/A digestion of sludge was developed and tested with pH and Eh as control parameters. It is shown that the performance of the real-time control strategy is better than that of a fixed time control strategy. While the real time controlled A/A digestion system can achieve a similar volatile suspended solids (VSS) destruction efficiency of 35.2 % as a continuously aerated system, it im proves the supernatant quality in a shorter aeration time(7. 75 d for a 20 d period).展开更多
文摘In this study an indirect adaptive sliding mode control (SMC) based on a fuzzy logic scheme is proposed to strengthen the tracking control performance of a general class of multi-input multi-output (MIMO) nonlinear uncertain systems. Combining reaching law approach and fuzzy universal approximation theorem, the proposed design procedure combines the advantages of fuzzy logic control, adaptive control and sliding mode control. The stability of the control systems is proved in the sense of the Lyapunov second stability theorem. Two simulation studies are presented to demonstrate the effectiveness of our new hybrid control algorithm.
基金Supported by the National High Technology Research and Development Program of China("863"Program)(2006AA06Z319)the National Key Technology R&D Programof the 11th Five-Year Plan China(2007BAK36B07)the Research Foundation for Youth Scholars of Beijing Technology and Business University(QNJJ-28)
文摘Experiments were conducted to study the performance characters of aerobic/anoxic (A/ A) digestion of sludge at 30± 1 ℃, while the sludge retention time (SRT) was kept 16 d. The varia tions of oxidation reduction potential (Eh ) and pH were continuously monitored during the A/A di gestion and the conversions of ammonium and nitrate were investigated. Important features on both Eh and pH profiles were identified to develop process control strategy. Since the feature point on Eh profile where d2 Eh/dt^2 =0 is very stable during anoxic cycle, it can be used to determine the end of denitrification. The end of nitrification can be identified according to dpH/dt = 0. A real-time control strategy of A/A digestion of sludge was developed and tested with pH and Eh as control parameters. It is shown that the performance of the real-time control strategy is better than that of a fixed time control strategy. While the real time controlled A/A digestion system can achieve a similar volatile suspended solids (VSS) destruction efficiency of 35.2 % as a continuously aerated system, it im proves the supernatant quality in a shorter aeration time(7. 75 d for a 20 d period).