BACKGROUND Numerous variables are linked to the success of vaginal delivery,including the subpubic arch angle(SPAA)during labor,the importance of which has not yet been fully elucidated.AIM To examine the SPAA distrib...BACKGROUND Numerous variables are linked to the success of vaginal delivery,including the subpubic arch angle(SPAA)during labor,the importance of which has not yet been fully elucidated.AIM To examine the SPAA distributional characteristics and to ascertain SPAA’s ability to predict the type and duration of labor.METHODS We determined the SPAA and analyzed the corresponding data.We also evaluated the relationship between the SPAA and the mode of delivery and the duration of labor by regression.The present study comprised a total of 301 pregnant women who had given birth at Beijing Tiantan Hospital of the Capital Medical University between January and December of 2021.RESULTS Our analysis of 301 pregnant women revealed that the SPAA measured using three-dimensional trans-perineal ultrasound had a minimum angle of 81°and a maximum angle of 122.2°.The angle in the normal vaginal delivery group was greater than that in the labor cesarean group(P=0.000).The SPAA was a highly significant positive predictor of normal vaginal delivery(P=0.000)with an area under the curve of 0.782(P=0.000;95%CI:0.717-0.848).We found the length of the second stage of labor to be positively influenced by the SPAA using linear regression analysis(P=0.045).CONCLUSION The SPAA was a highly significant positive predictor of normal vaginal delivery.The length of the second stage of labor and normal vaginal birth were predicted by SPAA.展开更多
Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Method...Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Methods: 90 patients with cirrhosis admitted to our hospital from January 2017 to December 2018 were enrolled in the cirrhosis group, and the cirrhosis components were group A, B and C according to the Child-Pauh classification criteria. During the same period, 90 healthy subjects who underwent physical examination were selected as the control group;real-time three-dimensional ultrasonography was performed to examine left ventricular function and portal hemodynamic parameters;Pearson correlation was used to analyze left ventricular function, portal hemodynamics and liver. Functional severity relationship.Results: The left heart E and E/A levels in the cirrhosis group were significantly lower than those in the control group (P<0.05), and the A level was significantly higher than the control group (P<0.05). The Dpv and Q levels in the cirrhosis group were significantly higher than those in the healthy control group. The difference was statistically significant (P<0.05), and the level of Vpv was significantly lower than that of healthy controls (P<0.05). There were significant differences in E, A and E/A levels between different Child-Paugh patients (P<0.05). There were significant differences in portal hemodynamics Dpv, Vpv and Q between the different Child-Paugh grades, and the difference was statistically significant (P<0.05);left heart function E and E/A and liver function severity There was a significant negative correlation (P<0.05). There was a significant positive correlation between left cardiac function A and liver function severity (P<0.05). Portal vein hemodynamics Dpv, Vpv and QE were significantly associated with liver function severity. Positive correlation (P<0.05). Conclusion: Real-time three-dimensional ultrasound can effectively detect left ventricular function and portal hemodynamics changes in patients with cirrhosis, and left heart function, portal hemodynamics and liver function severity are significantly correlated.展开更多
文摘BACKGROUND Numerous variables are linked to the success of vaginal delivery,including the subpubic arch angle(SPAA)during labor,the importance of which has not yet been fully elucidated.AIM To examine the SPAA distributional characteristics and to ascertain SPAA’s ability to predict the type and duration of labor.METHODS We determined the SPAA and analyzed the corresponding data.We also evaluated the relationship between the SPAA and the mode of delivery and the duration of labor by regression.The present study comprised a total of 301 pregnant women who had given birth at Beijing Tiantan Hospital of the Capital Medical University between January and December of 2021.RESULTS Our analysis of 301 pregnant women revealed that the SPAA measured using three-dimensional trans-perineal ultrasound had a minimum angle of 81°and a maximum angle of 122.2°.The angle in the normal vaginal delivery group was greater than that in the labor cesarean group(P=0.000).The SPAA was a highly significant positive predictor of normal vaginal delivery(P=0.000)with an area under the curve of 0.782(P=0.000;95%CI:0.717-0.848).We found the length of the second stage of labor to be positively influenced by the SPAA using linear regression analysis(P=0.045).CONCLUSION The SPAA was a highly significant positive predictor of normal vaginal delivery.The length of the second stage of labor and normal vaginal birth were predicted by SPAA.
文摘Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Methods: 90 patients with cirrhosis admitted to our hospital from January 2017 to December 2018 were enrolled in the cirrhosis group, and the cirrhosis components were group A, B and C according to the Child-Pauh classification criteria. During the same period, 90 healthy subjects who underwent physical examination were selected as the control group;real-time three-dimensional ultrasonography was performed to examine left ventricular function and portal hemodynamic parameters;Pearson correlation was used to analyze left ventricular function, portal hemodynamics and liver. Functional severity relationship.Results: The left heart E and E/A levels in the cirrhosis group were significantly lower than those in the control group (P<0.05), and the A level was significantly higher than the control group (P<0.05). The Dpv and Q levels in the cirrhosis group were significantly higher than those in the healthy control group. The difference was statistically significant (P<0.05), and the level of Vpv was significantly lower than that of healthy controls (P<0.05). There were significant differences in E, A and E/A levels between different Child-Paugh patients (P<0.05). There were significant differences in portal hemodynamics Dpv, Vpv and Q between the different Child-Paugh grades, and the difference was statistically significant (P<0.05);left heart function E and E/A and liver function severity There was a significant negative correlation (P<0.05). There was a significant positive correlation between left cardiac function A and liver function severity (P<0.05). Portal vein hemodynamics Dpv, Vpv and QE were significantly associated with liver function severity. Positive correlation (P<0.05). Conclusion: Real-time three-dimensional ultrasound can effectively detect left ventricular function and portal hemodynamics changes in patients with cirrhosis, and left heart function, portal hemodynamics and liver function severity are significantly correlated.