Various experimental conditions were described for the vanadium determinationby graphite furnace atomic absorption spectroscopy (GFAAS). The experiments showed that whenatomization took place under the conditions wher...Various experimental conditions were described for the vanadium determinationby graphite furnace atomic absorption spectroscopy (GFAAS). The experiments showed that whenatomization took place under the conditions where the combination of a pyrolytic coating graphitetube and fast raising temperature were used and the temperature was stable, the signal peak shapescould be improved, the sensitivity was enhanced, and the memory effect was removed. The vanadium infood and traditional Chinese medicinal herbs can be accurately determined using the standard curvemethod.展开更多
A new selective and sensitive kinetic method for determination of trace amounts of vanadium(Ⅴ) (0.5~40ng/ml) based on its catalytic effect on the oxidation of azomethine H by bromate at pH 4.2 and 25 ℃ was rep...A new selective and sensitive kinetic method for determination of trace amounts of vanadium(Ⅴ) (0.5~40ng/ml) based on its catalytic effect on the oxidation of azomethine H by bromate at pH 4.2 and 25 ℃ was reported and its reaction mechanism was studied.The reaction was monitored spectrophotometrically by measuring the increase in absorbance of oxidation product of azomethine H at 436 nm after a fixed time ( 5 min ).The detection limit of the method is down to 2.0×10 -10 g/ml and the relative standard deviation (RSD) for 30 ng/ml of V(Ⅴ) is 0.26 % ( n =6). The effect of foreign ions on V(Ⅴ) determination was also discussed,and the method is mostly free from interferences of other ions.The proposed method was successfully applied to the determination of trace amounts of vanadium in water samples.展开更多
Vanadium is quantitatively retained on 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)-ammonium tetraphenylborate with microcrystalline naphthalene or by a column method in the pH range of 2.1–4.5 from a l...Vanadium is quantitatively retained on 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)-ammonium tetraphenylborate with microcrystalline naphthalene or by a column method in the pH range of 2.1–4.5 from a large volume of aqueous solutions of various samples. After filtration, the solid mass consisting of the vanadium complex and naphthalene was dissolved with 5 mL of dimethylformamide and the metal was determined by the third derivative spectrophotometry. Vanadium complex can alternatively be quantitatively adsorbed on ammonium tetraphenylborate-naphthalene adsorbent packed in a column and determined similarly. About 0.05 μg of vanadium can be concentrated in a column from 250 mL of aqueous sample, where its concentration is as low as 0.2 ng/mL. The interference of a large number of anions and cations has been studied and the optimized conditions developed were utilized for the determination of trace amount of vanadium in various samples.展开更多
文摘Various experimental conditions were described for the vanadium determinationby graphite furnace atomic absorption spectroscopy (GFAAS). The experiments showed that whenatomization took place under the conditions where the combination of a pyrolytic coating graphitetube and fast raising temperature were used and the temperature was stable, the signal peak shapescould be improved, the sensitivity was enhanced, and the memory effect was removed. The vanadium infood and traditional Chinese medicinal herbs can be accurately determined using the standard curvemethod.
文摘A new selective and sensitive kinetic method for determination of trace amounts of vanadium(Ⅴ) (0.5~40ng/ml) based on its catalytic effect on the oxidation of azomethine H by bromate at pH 4.2 and 25 ℃ was reported and its reaction mechanism was studied.The reaction was monitored spectrophotometrically by measuring the increase in absorbance of oxidation product of azomethine H at 436 nm after a fixed time ( 5 min ).The detection limit of the method is down to 2.0×10 -10 g/ml and the relative standard deviation (RSD) for 30 ng/ml of V(Ⅴ) is 0.26 % ( n =6). The effect of foreign ions on V(Ⅴ) determination was also discussed,and the method is mostly free from interferences of other ions.The proposed method was successfully applied to the determination of trace amounts of vanadium in water samples.
基金theNationalResearchCouncilofIslamicRepublicofIran (No .NRCI1719)
文摘Vanadium is quantitatively retained on 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)-ammonium tetraphenylborate with microcrystalline naphthalene or by a column method in the pH range of 2.1–4.5 from a large volume of aqueous solutions of various samples. After filtration, the solid mass consisting of the vanadium complex and naphthalene was dissolved with 5 mL of dimethylformamide and the metal was determined by the third derivative spectrophotometry. Vanadium complex can alternatively be quantitatively adsorbed on ammonium tetraphenylborate-naphthalene adsorbent packed in a column and determined similarly. About 0.05 μg of vanadium can be concentrated in a column from 250 mL of aqueous sample, where its concentration is as low as 0.2 ng/mL. The interference of a large number of anions and cations has been studied and the optimized conditions developed were utilized for the determination of trace amount of vanadium in various samples.