期刊文献+
共找到14篇文章
< 1 >
每页显示 20 50 100
Comparative study of effectiveness of different var compensation devices in large-scale power networks 被引量:3
1
作者 Reza Sirjani Azah Mohamed Hussain Shareef 《Journal of Central South University》 SCIE EI CAS 2013年第3期715-723,共9页
A comparison of the effectiveness of installing reactive power compensators,such as shunt capacitors,static var compensators(SVCs),and static synchronous compensators(STATCOMs),was presented in large-scale power netwo... A comparison of the effectiveness of installing reactive power compensators,such as shunt capacitors,static var compensators(SVCs),and static synchronous compensators(STATCOMs),was presented in large-scale power networks.A suitable bus was first identified using modal analysis method.The single shunt capacitor,single SVC,and single STATCOM were installed separately on the most critical bus.The effects of the installation of different devices on power loss reduction,voltage profile improvement,and voltage stability margin enhancement were examined and compared for 57-and 118-bus transmission systems.The comparative study results show that SVC,and STATCOM are expensive compared to shunt capacitor,yet the effect of installing STATCOM is better than SVC and the effect of installing SVC is better than that of shunt capacitor in achieving power loss reduction,voltage profile improvement and voltage stability margin enhancement. 展开更多
关键词 shunt capacitor static var compensator static synchronous compensator power loss voltage profile voltage stability
下载PDF
Hybrid compensation method for traction power quality compensators in electrified railway power supply system 被引量:1
2
作者 Mohammad Arabahmadi Mahdi Banejad Ali Dastfan 《Global Energy Interconnection》 CAS CSCD 2021年第2期158-168,共11页
In order to improve the Power Quality(PQ)of traction power supply system and reduce the power rating and operation cost of compensator,a Static VAR Compensator(SVC)integrated Railway Power Conditioner(RPC)is presented... In order to improve the Power Quality(PQ)of traction power supply system and reduce the power rating and operation cost of compensator,a Static VAR Compensator(SVC)integrated Railway Power Conditioner(RPC)is presented in this paper.RPC is a widely used device in the AC electrified railway systems to enhance the PQ indices of the main network.The next generation of this equipment is Active Power Quality Compensator(APQC).The major concern of these compensators is their high kVA rating.In this paper,a hybrid technique is proposed to solve aforementioned problems.A combination of SVC as an auxiliary device is employed together with the main compensators,i.e.,RPC and APQC that leads on to the reduction of power rating of the main compensators.The use of proposed scheme will cause to reduce significantly the initial investment cost of compensation system.The main compensators are only utilized to balance active powers of two adjacent feeder sections and suppress harmonic currents.The SVCs are used to compensate reactive power and suppress the third and fifth harmonic currents.In this paper firstly,the PQ compensation procedure in AC electrified railway is analyzed step by step.Then,the control strategies for SVC and the main compensators are presented.Finally,a simulation is fulfilled using Matlab/Simulink software to verify the effectiveness and validity of the proposed scheme and compensation strategy and also demonstrate that this technique could compensate all PQ problems. 展开更多
关键词 AC electrified railway Power quality compensation Auxiliary compensator Static var compensator Power rating reduction of converters
下载PDF
Research on resonance fault caused by dc magnetic biasing in ultra high voltage transformer with parallel static var compensator
3
作者 Yang Nan Zhu Zimin Yuan Tiejiang 《Journal of Southeast University(English Edition)》 EI CAS 2020年第3期301-312,共12页
For dealing with the resonance fault of ultra-high voltage transformers(UHVTs)with the parallel thyristor controlled reactor(TCR)+the filter compensator(FC)type static var compensator(SVC)caused by dc magnetic biasing... For dealing with the resonance fault of ultra-high voltage transformers(UHVTs)with the parallel thyristor controlled reactor(TCR)+the filter compensator(FC)type static var compensator(SVC)caused by dc magnetic biasing,a simulation model of UHVT with parallel SVC for the frequency analysis of the impedance characteristics and a magnetic-field coupling model for UHVT based on classic Jiles-Atherton hysteresis theories are constructed based on the MATLAB/Simulink platform.Both the theoretical and simulation results prove that the resonance fault is caused by the resonance point on the low-voltage side of the transformer,which will approach the 4th harmonic point under magnetic biasing.Based on the fault analysis,a new resonance control method is proposed by adding reactance with by-pass switches in series with FC branches.Under dc magnetic biasing,the cutoff of the by-pass switch will increase the series reactance rate of the FC branches and change the resonance point.In order to avoid the 7th harmonic increasement caused by this method,the firing angle of the TCR branches is locked between 130°and 180°.The effect of the proposed method is validated by the simulation model of a 750 kV UHVT and the results show that the mechanism analysis of the resonance fault is correct and the resonance control method is valid. 展开更多
关键词 static var compensator ultra-high voltage transformer magnetic biasing resonance fault
下载PDF
Potential Solution of Power Flow Constraints of Bangladesh Power System
4
作者 Nahid-Al-Masood Samsuzzaman Rupu Shaikh Mostafa Fahad Khalid Imtiaz Saad Md. Quamrul Ahsan 《Journal of Energy and Power Engineering》 2012年第8期1315-1319,共5页
This paper presents a potential solution of power flow constraints of BPS (Bangladesh power system) using VAR (volt ampere reactive) compensation. VAR compensation is defined as the management of reactive power to... This paper presents a potential solution of power flow constraints of BPS (Bangladesh power system) using VAR (volt ampere reactive) compensation. VAR compensation is defined as the management of reactive power to improve the performance ofac power systems. The concept of VAR compensation embraces a wide and diverse field of both system and customer problems, especially related with power quality issues, since most of power quality problems can be attenuated or solved with an adequate control of reactive power. VAR compensation in transmission systems also improves the stability of the ac system by increasing the maximum active power that can be transmitted. It also helps to maintain a substantially fiat voltage profile at all levels of power transmission. BPS is currently facing problems in few 132 grid points where the thermal limits of transmission are often exceeded. BPS is also foreseeing problem in transmitting additional power from the new generating units in Sylhet to Dhaka zone. This paper investigates the potential solution to these transmission problems. 展开更多
关键词 FACTS devices thermal limit var compensation power transfer overloading problem.
下载PDF
Stability Improvement of Power System by Using PI & PD Controller
5
作者 Habibur Rahman Rafiqul Islam Sheikh Harun-Or-Rashid 《Computer Technology and Application》 2013年第2期111-118,共8页
This paper presents the model of a SVC (Static VAR Compensator) which is controlled externally by a PI (Proportional Integral) & PD (Proportional Differential) controllers for the improvements of voltage stabil... This paper presents the model of a SVC (Static VAR Compensator) which is controlled externally by a PI (Proportional Integral) & PD (Proportional Differential) controllers for the improvements of voltage stability and damping effect of an on line power system. Both controller parameters has been optimized by using Ziegler-Nichols close loop tuning method. Both single phase and three phase (L-L) faults have been considered in the research. In this paper, a power system network is considered which is simulated in the phasor simulation method & the network is simulated in four steps; without SVC, With SVC but no externally controlled, SVC with PI controller & SVC with PD controller. Simulation result shows that without SVC, the system parameters become unstable during faults. When SVC is imposed in the network, then system parameters become stable. Again, when SVC is controlled externally by PI & PD controllers, then system parameters becomes stable in faster way then without controller. It has been observed that the SVC ratings are only 50 MVA with controllers and 200 MVA without controllers. So, SVC with PI & PD controllers are more effective to enhance the voltage stability and increases power transmission capacity of a power system. The power system oscillations are also reduced with controllers in compared to that of without controllers. So with both controllers the system performance is greatly enhanced. 展开更多
关键词 SVC (Static var Compensator) PI (Proportional Integral) PD (Proportional Differential) Controller AVR TCR(Thyristor Controlled Reactor) voltage regulation MATLAB Simulink.
下载PDF
Simulation, Power Quality Analysis and Improvements in a Hot Rolling Mill Using a STATCOM
6
作者 Pablo Ardura Gonzalo Alonso +7 位作者 Jose Manuel Cano Joaquin Gonzalez Nomiella Francisco Pedrayes Femando Briz Manes Fernandez Cabanas Manuel Garcia Melero Carlos Hiram Rojas Jose Ramon Gonzadez Suaxez 《Journal of Energy and Power Engineering》 2014年第9期1633-1641,共9页
This paper presents an analysis of the electric power flows in a hot rolling mill plant using a power quality analyzer and developing simulation models with Matlab-Simulink. The model inputs have been taken from proce... This paper presents an analysis of the electric power flows in a hot rolling mill plant using a power quality analyzer and developing simulation models with Matlab-Simulink. The model inputs have been taken from process data by the process computer of the plant. Data from different rolling campaigns have been analysed. A STATCOM (static synchronous compensator) with a control strategy based on voltage oriented control with d-q coordinates is used as solution to improve the reactive compensation as well as to minimize the voltage fluctuations and sags effect. The overall electric model has been simulated with the STATCOM to check the improvement in the voltage stability and the consumption. 展开更多
关键词 CYCLOCONVERTER d-q reference frame hot rolling mill STATCOM SVC (static var compensator) VOC (voltage orientedcontrol) voltage sag.
下载PDF
Enhancement of Real Power Transfer Capability of Transmission Lines
7
作者 Nahid-Al-Masood Amina Hasan Abedin Abdul Hasib Chowdhury 《Journal of Energy and Power Engineering》 2012年第7期1114-1118,共5页
As power system interconnections become more prevalent, there has been an increase in use of thyristor controlled shunt connected compensation devices for dynamic power compensation and enhancement of real power trans... As power system interconnections become more prevalent, there has been an increase in use of thyristor controlled shunt connected compensation devices for dynamic power compensation and enhancement of real power transmission capacity. In this paper, an enhancement technique of real power transfer capacity of transmission lines is presented. A SVC (static var compensator) is designed and applied to a simple power system for this purpose. Increase in power flow and improvement in bus voltage profile are observed after using the SVC. Stability analysis of the system after experiencing fault as well as consequent fault clearance by time domain analysis has also beeu performed and satisfactory results are obtained. 展开更多
关键词 SVC (static var compensator) power transfer capability minimum susceptance load flow analysis fault analysis stabilityanalysis.
下载PDF
Comparison and Performance Analysis of FACTs Controller in System Stability
8
作者 Karthikeyan Ramasamy 《Circuits and Systems》 2016年第10期2948-2958,共11页
In large inter connected power systems, inter-area oscillations are turned to be a severe problem. Hence inter-area oscillations cause severe problems like damage to generators, reduce the power transfer capability of... In large inter connected power systems, inter-area oscillations are turned to be a severe problem. Hence inter-area oscillations cause severe problems like damage to generators, reduce the power transfer capability of transmission lines, increase wear and tear on network components, increase line losses etc. This paper is to maintain the stability of system by damping inter-area oscillations. Implementation of new equipment consists of high power electronics based technologies such as FACTs and proper controller design has become an essential to provide better damping performance than Power System Stabilizer (PSS). With development of Wide Area Measurement System (WAMS), remote signals have become as feedback signals to design Wide Area Damping Controller (WADC) for FACTs devices. In this work, POD is applied to both SVC and SSSC. Simulation studies are carried out in Power System Analysis Toolbox (PSAT) environment to evaluate the effectiveness of the FACTs controller in a large area power system. Results show that extensive analysis of FACTs controller for improving stability of system. 展开更多
关键词 Power System Stabilizer Wide-Area Measurement System Wide-Area Damping Controller Static var Compensator Flexible AC Transmission System Power Oscillation Damper Static Synchronous Series Compensator
下载PDF
Optimal electromagnetic hybrid negative current compensation method for high-speed railway power supply system 被引量:5
9
作者 Jiaxin YUAN Yongheng ZHONG +7 位作者 Chenmeng ZHANG Wenjun ZENG Baichao CHEN Cuihua TIAN Changhong DENG Min ZHOU Kazuhiro MURAMATSU Jin WANG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2016年第1期123-134,共12页
To achieve economical compensation for the huge-capacity negative sequence currents generated by high-speed railway load, an electromagnetic hybrid compensation system(EHCS) and control strategy is proposed.The EHCS i... To achieve economical compensation for the huge-capacity negative sequence currents generated by high-speed railway load, an electromagnetic hybrid compensation system(EHCS) and control strategy is proposed.The EHCS is made up of a small-capacity railway static power conditioner(RPC) and a large-capacity magnetic static var compensator(MSVC). Compared with traditional compensation methods, the EHCS makes full use of the SVC’s advantages of economy and reliability and of RPC’s advantages of technical capability and flexibility. Based on the idea of injecting a negative sequence, the compensation principle of the EHCS is analyzed in detail. Then the minimum installation capacity of an EHCS is theoretically deduced. Furthermore, a constraint optimization compensation strategy that meets national standards, which reduces compensation capacity further, is proposed. An experimental platform based on a digital signal processor(DSP) and a programmable logic controller(PLC) is built to verify the analysis. Simulated and experimental results are given to demonstrate the effectiveness and feasibility of the proposed method. 展开更多
关键词 Unbalanced load Electromagnetic hybrid compensation Railway static power conditioner(RPC) Magnetic static var compensator(MSVC) Capacity optimize
原文传递
Parameter Identification for Static Var Compensator Model Using Sensitivity Analysis and Improved Whale Optimization Algorithm 被引量:3
10
作者 Qiang Guo Lei Gao +1 位作者 Xiaojie Chu Huadong Sun 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2022年第2期535-547,共13页
A parameter estimation method based on an improved Whale Optimization Algorithm is proposed in this paper to identify the parameters of a static var compensator(SVC)model.First,a mathematical model of SVC is establish... A parameter estimation method based on an improved Whale Optimization Algorithm is proposed in this paper to identify the parameters of a static var compensator(SVC)model.First,a mathematical model of SVC is established.Then,the reverse learning strategy and Levy flight disturbance strategy are introduced to improve the whale optimization algorithm,and the improved whale optimization algorithm is applied to the parameter identification of the static var compensator model.Finally,a stepwise identification method,by analyzing the local sensitivities of parameters,is proposed which solves the problem of low accuracy caused by multi-parameter identification.This method provides a new estimation strategy for accurately identifying the parameters of the static var compensator model.Estimation results show that the parameter estimation method can be an effective tool to solve the problem of parameter identification for the SVC model. 展开更多
关键词 Local sensitivity analysis parameter estimation static var compensator model stepwise identification method whale Optimization Algorithm
原文传递
Optimal Controller Design for Non-Affine Nonlinear Power Systems with Static Var Compensators for Hybrid UAVs
11
作者 Yanchu Li Qingqing Ding +1 位作者 Shufang Li Stanimir Valtchev 《Tsinghua Science and Technology》 SCIE EI CAS CSCD 2022年第1期196-206,共11页
A generalized non-affine nonlinear power system model is presented for a single machine bus power system with a Static Var Compensator(SVC)or State Var System(SVS)for hybrid Unmanned Aerial Vehicles(UAVs).The model is... A generalized non-affine nonlinear power system model is presented for a single machine bus power system with a Static Var Compensator(SVC)or State Var System(SVS)for hybrid Unmanned Aerial Vehicles(UAVs).The model is constructed by differential algebraic equations on the MATLAB-Simulink platform with the programming technique of its S-Function.Combining the inverse system method and the Linear Quadratic Regulation(LQR),an optimized SVC controller is designed.The simulations under three fault conditions show that the proposed controller can effectively improve the power system transient performance. 展开更多
关键词 Static var Compensator(SVC) Unmanned Aerial Vehicles(UAV) power system non-affine nonlinear control inverse system method Linear Quadratic Regulation(LQR)
原文传递
Decentralized robust control of multiple static var compensators via Hamiltonian function method
12
作者 Yanhong LIU Jianyong LI +2 位作者 Bing CHU Honghai TANG Lijun ZHANG 《控制理论与应用(英文版)》 EI CSCD 2013年第2期215-221,共7页
Using the energy-based Hamiltonian function method, this paper investigates the decentralized robust nonlinear control of multiple static var compensators (SVCs) in multimachine multiload power systems. First, the u... Using the energy-based Hamiltonian function method, this paper investigates the decentralized robust nonlinear control of multiple static var compensators (SVCs) in multimachine multiload power systems. First, the uncertain nonlinear differential algebraic equation model is constructed for the power system. Then, the dissipative Hamiltonian realization of the system is completed by means of variable transformation and prefeedback control. Finally, based on the obtained dissipative Hamiltonian realization, a decentralized robust nonlinear controller is put forward. The proposed controller can effectively utilize the internal structure and the energy balance property of the power system. Simulation results verify the effectiveness of the control scheme. 展开更多
关键词 Static var compensators Multimachine multiload power systems Uncertain nonlinear differential alge-braic systems Dissipative Hamiltonian realization Decentralized robust control
原文传递
Active disturbance rejection based load frequency control and voltage regulation in power systems
13
作者 Lili DONG Anusree MANDALI +1 位作者 Allen MORINEC Yang ZHAO 《Control Theory and Technology》 EI CSCD 2018年第4期336-350,共15页
An active disturbance rejection controller (ADRC) is developed for load frequency control (LFC) and voltage regulation respectively in a power system. For LFC, the ADRC is constructed on a three-area interconnecte... An active disturbance rejection controller (ADRC) is developed for load frequency control (LFC) and voltage regulation respectively in a power system. For LFC, the ADRC is constructed on a three-area interconnected power system. The control goal is to maintain the frequency at nominal value (60Hz in North America) and keep tie-line power flow at scheduled value. For voltage regulation, the ADRC is applied to a static var compensator (SVC) as a supplementary controller. It is utilized to maintain the voltages at nearby buses within the ANSI C84.1 limits (or +5% tolerance). Particularly, an alternative ADRC with smaller controller gains than classic ADRC is originally designed on the SVC system. From power generation and transmission to its distribution, both voltage and frequency regulating systems are subject to large and small disturbances caused by sudden load changes, transmission faults, and equipment loss/malfunction etc. The simulation results and theoretical analyses demonstrate the effectiveness of the ADRCs in compensating the disturbances and achieving the control goals. 展开更多
关键词 Active disturbance rejection control power systems load frequency control static var compensator voltageregulation DISTURBANCE system uncertainty
原文传递
Interactive DE for solving combined security environmental economic dispatch considering FACTS technology
14
作者 Belkacem MAHDAD K. SRAIRI T. BOUKTIR 《Frontiers in Energy》 SCIE CSCD 2013年第4期429-447,共19页
This paper presents an efficient interactive differential evolution ODE) to solve the multi-objective security environmental/economic dispatch (SEED) pro- blem considering multi shunt flexible AC transmission syst... This paper presents an efficient interactive differential evolution ODE) to solve the multi-objective security environmental/economic dispatch (SEED) pro- blem considering multi shunt flexible AC transmission system (FACTS) devices. Two sub problems are proposed. The first one is related to the active power planning to minimize the combined total fuel cost and emissions, while the second is a reactive power planning (RPP) using multi shunt FACTS device based static VAR compensator (SVC) installed at specified buses to make fine corrections to the voltage deviation, voltage phase profiles and reactive power violation. The migration operation inspired from biogeography-based optimization (BBO) algorithm is newly introduced in the proposed approach, thereby effectively exploring and exploiting promising regions in a space search by creating dynamically new efficient partitions. This new mechanism based migration between individuals from different subsystems makes the initial partitions to react more by changing experiences. To validate the robustness of the proposed approach, the proposed algorithm is tested on the Algerian 59-bus electrical network and on a large system, 40 generating units considering valve-point loading effect. Comparison of the results with recent global optimization methods show the superiority of the proposed IDE approach and confirm its potential for solving practical optimal power flow in terms of solution quality and convergence characteristics. 展开更多
关键词 optimal power flow (OPF) economic dispatch environment differential evolution migration operator MULTI-OBJECTIVE flexible AC transmission systems (FACTS) static var compensator (SVC)
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部