期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Switching variability index based multiple strategy CFAR detector 被引量:4
1
作者 Yang Li Zhenyuan Ji +1 位作者 Bingfei Li Gil Alterovitz 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2014年第4期580-587,共8页
A switching variability index (SVl) constant false alarm rate (CFAR) detector is proposed for improving the detection performance of VI-CFAR detectors in multiple targets backgrounds. When the presence of non-homo... A switching variability index (SVl) constant false alarm rate (CFAR) detector is proposed for improving the detection performance of VI-CFAR detectors in multiple targets backgrounds. When the presence of non-homogeneity in CFAR reference windows is indicated by a VI-CFAR detector, a switching- CFAR detector is introduced to optimize the performance of the VI-CFAR detector in homogeneous, multiple targets and clutter edge backgrounds. The structure and parameters selection method of the SVI-CFAR detector is presented. Comparisons with classic CFAR detectors and recently proposed detectors are also given. Theoretical analysis and simulation results show that SVICFAR detector maintains the good performance of the VI-CFAR detector in homogeneous and clutter edge backgrounds, while greatly improving the capacity of anti-multi targets. 展开更多
关键词 switching variability index constant false alarm rate(SVI-CFAR) adaptive detection complex environment multiple-strategy detection radar target detection.
下载PDF
Correlation of Inferior Vena Cava Respiratory Variability Index with Central Venous Pressure and Hemodynamic Parameters in Ventilated Pigs with Septic Shock 被引量:3
2
作者 LIU Xiao Lei TAO Yong Kang +5 位作者 YAN Sheng Tao QI Zhi Wei LU Hai Tao WANG Hai Feng GU Cheng Dong ZHANG Guo Qiang 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2013年第6期500-503,共4页
Septic shock is a common critical condition, for which effective early fluid resuscitation is the therapeutic focus. According to the 2008 international guidelines for management of severe sepsis and septic shock, res... Septic shock is a common critical condition, for which effective early fluid resuscitation is the therapeutic focus. According to the 2008 international guidelines for management of severe sepsis and septic shock, resuscitation should achieve a central venous pressure (CVP) of 8-12 mmHg within the first 6 h. However, it is still uncertain about the sensitivity and specificity of CVP in reflecting the cardiac preload. Ultrasonography is a simple, rapid, non-invasive, and repeatable method for the measurement of sensitivity and specificity of CVP and has thus gradually attracted the increasing attention of physicians. It was reported that ultrasonography can show the inferior vena cava diameter, respiratory variability index, and blood volume in patients with sepsis or heart failure. 展开更多
关键词 CVP SVV Correlation of Inferior Vena Cava Respiratory variability Index with Central Venous Pressure and Hemodynamic Parameters in Ventilated Pigs with Septic Shock
下载PDF
关于矿体指标兼顾已知点距离与方向权函数估计方法的研究
3
作者 汪云甲 《有色金属》 CSCD 1991年第3期7-11,共5页
本文提出了一套新的估值权函数,这种权函数既考虑了已知点的分布状态,又考虑到了矿体指标的空间特性。通过相当多的实例计算与计算机模拟,得到了一些重要结论。
关键词 Orebody indexes(geological variables) Weighting function ESTIMATE Computer simulation
下载PDF
Mean Difference of Truncated Normal Distribution
4
作者 Giovanni Girone Antonella Massari +1 位作者 Fabio Manca Claudia Marin 《Applied Mathematics》 2020年第11期1162-1166,共5页
The purpose of this paper is to broaden the knowledge of mean difference and, in particular, of an important distribution model known as truncated normal distribution, which is widely used in applied sciences and econ... The purpose of this paper is to broaden the knowledge of mean difference and, in particular, of an important distribution model known as truncated normal distribution, which is widely used in applied sciences and economics. In this work, we obtained the general formula of mean difference, which is not yet reported in literature, for the aforementioned distribution model and also for particular truncated cases. 展开更多
关键词 Mean Difference Truncated Normal Distribution variability indexes Economic Sciences
下载PDF
Mean Difference and Mean Deviation of Tukey Lambda Distribution
5
作者 Giovanni Girone Antonella Massari +1 位作者 Fabio Manca Angela Maria D’Uggento 《Applied Mathematics》 2020年第8期771-778,共8页
The purpose of this paper is to broaden the knowledge of mean difference and,<span><span><span style="font-family:;" "=""> </span></span></span><span sty... The purpose of this paper is to broaden the knowledge of mean difference and,<span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">in particular, of an important distribution model known as Tukey lambda, which is generally used to choose a model to fit data.</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">We have obtained compact formulas, which are not yet reported in literature, of mean deviation and mean difference related to the said distribution model.</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">These results made it possible to analyze the relationships among variability indexes, namely standard deviation, mean deviation and mean difference, regarding Tukey lambda model.</span></span></span> 展开更多
关键词 Mean Difference Mean Deviation Tukey Lambda Distribution variability indexes Relationships
下载PDF
PRECISE ASYMPTOTICS IN SELF-NORMALIZED SUMS OF ITERATED LOGARITHM FOR MULTIDIMENSIONALLY INDEXED RANDOM VARIABLES 被引量:3
6
作者 Jiang Chaowei Yang Xiaorong 《Applied Mathematics(A Journal of Chinese Universities)》 SCIE CSCD 2007年第1期87-94,共8页
In the case of Z+^d(d ≥ 2)-the positive d-dimensional lattice points with partial ordering ≤, {Xk,k∈ Z+^d} i.i.d, random variables with mean 0, Sn =∑k≤nXk and Vn^2 = ∑j≤nXj^2, the precise asymptotics for ∑... In the case of Z+^d(d ≥ 2)-the positive d-dimensional lattice points with partial ordering ≤, {Xk,k∈ Z+^d} i.i.d, random variables with mean 0, Sn =∑k≤nXk and Vn^2 = ∑j≤nXj^2, the precise asymptotics for ∑n1/|n|(log|n|dP(|Sn/Vn|≥ε√log log|n|) and ∑n(logn|)b/|n|(log|n|)^d-1P(|Sn/Vn|≥ε√log n),as ε↓0,is established. 展开更多
关键词 multidimensionally indexed random variable precise asymptotics self-normalized sum Davislaw of large numbers law of iterated logarithm.
下载PDF
The Effect of Non-Invasive Goal Directed Fluid Administration on Graft Function in Deceased Donor Renal Transplantation: A Pilot Study
7
作者 Joseph R. Whiteley Jason M. Taylor +5 位作者 John J. Freely Jr. Thomas I. Epperson Laura Bell John L. Murray IV Charles F. Bratton William R. Hand 《Open Journal of Organ Transplant Surgery》 2016年第3期13-21,共9页
Background: Non-invasive goal directed fluid therapy during deceased donor renal transplant (CRT) may reduce the incidence of delayed graft function. Plethysmograph Variability Index (PVI) has been shown to predict fl... Background: Non-invasive goal directed fluid therapy during deceased donor renal transplant (CRT) may reduce the incidence of delayed graft function. Plethysmograph Variability Index (PVI) has been shown to predict fluid responsiveness during surgery. This pilot study evaluated the feasibility of goal directed fluid administration protocol based upon PVI studying the incidence of delayed graft function (DGF) in renal transplant recipients. Methods: Twenty patients underwent primary CRT. The Control group received intravenous fluid (IVF) at a calculated constant rate. The Treatment group received a baseline IVF infusion throughout the surgery. PVI values greater than 13% were treated with 250 ml boluses of IVF. Primary end point was DGF;total IVF administration and urinary biomarker NGAL levels were secondary endpoints. Results: Treatment group at every time point received significantly less IVF. There was no significant difference in incidence of DGF between the groups. 2 patients in the Control group and 6 in the Treatment group developed DGF. NGAL was not associated with the group assignment or total IVF given (p < 0.2). Conclusions: The effectiveness of goal directed fluid therapy with non-invasive dynamic parameters has not been validated in renal transplant surgery and larger prospective studies are needed to determine its utility in renal transplantation. 展开更多
关键词 Deceased Donor Renal Transplant Non-Invasive Goal Directed Fluid Therapy Delayed Graft Function Plethysmograph variability Index
下载PDF
A new structural reliability index based on uncertainty theory 被引量:8
8
作者 Pidong WANG Jianguo ZHANG +1 位作者 Hao ZHAI Jiwei QIU 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2017年第4期1451-1458,共8页
The classical probabilistic reliability theory and fuzzy reliability theory cannot directly measure the uncertainty of structural reliability with uncertain variables, i.e., subjective random and fuzzy variables. In o... The classical probabilistic reliability theory and fuzzy reliability theory cannot directly measure the uncertainty of structural reliability with uncertain variables, i.e., subjective random and fuzzy variables. In order to simultaneously satisfy the duality of randomness and subadditivity of fuzziness in the reliability problem, a new quantification method for the reliability of structures is presented based on uncertainty theory, and an uncertainty-theory-based perspective of classical Cornell reliability index is explored. In this paper, by introducing the uncertainty theory, we adopt the uncertain measure to quantify the reliability of structures for the subjective probability or fuzzy variables, instead of probabilistic and possibilistic measures. We utilize uncertain variables to uniformly represent the subjective random and fuzzy parameters, based on which we derive solutions to analyze the uncertainty reliability of structures with uncertainty distributions. Moreover, we propose the Cornell uncertainty reliability index based on the uncertain expected value and variance.Experimental results on three numerical applications demonstrate the validity of the proposed method. 展开更多
关键词 Belief degree Reliability index Structural reliability Uncertain measure Uncertain variable
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部