AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants ...AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants underwent ICL surgery and were divided into the low(<250μm)and normal(250-1000μm)vault groups based on the postoperative vault at 3mo.The preoperative biometric parameters and clinical outcomes were compared between the two groups.The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized estimating equations.RESULTS:Sixteen(23 eyes)and 36 patients(63 eyes)were in the low and normal vault groups,respectively.All implantation procedures were uneventful with no cataract formation in the early postoperative period.The sulcusto-sulcus lens rise(STSL)and iris ciliary angle(ICA)were correlated with vault at 3mo after surgery.Every 0.1 mm increase in STSL was associated with 38.9μm decrease in the postoperative 3-month vault.A rise of 1 degree in ICA is associated with a reduction of 4μm in vault.CONCLUSION:Eyes with a narrow ciliary sulcus are associated with a higher rate of low vault after ICL implantation,suggesting a need for adjustments to the ICL size in these patients.Evaluating the characteristics of the ciliary sulcus contributes valuable information to predict low vault after surgery.展开更多
AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images we...AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images were collected from the Lixiang Eye Hospital to provide the patient’s preoperative parameters as well as the vault of the ICL after implantation.The vault was set as the prediction target,and the input elements were mainly ciliary sulcus shape parameters,which included 6 angular parameters,2 area parameters,and 2 parameters,distance between ciliary sulci,and anterior chamber height.A random forest regression model was applied to predict the vault,with the number of base estimators(n_estimators)of 2000,the maximum tree depth(max_depth)of 17,the number of tree features(max_features)of Auto,and the random state(random_state)of 40.0.RESULTS:Among the parameters selected in this study,the distance between ciliary sulci had a greater importance proportion,reaching 52%before parameter optimization is performed,and other features had less influence,with an importance proportion of about 5%.The importance of the distance between the ciliary sulci increased to 53% after parameter optimization,and the importance of angle 3 and area 1 increased to 5% and 8%respectively,while the importance of the other parameters remained unchanged,and the distance between the ciliary sulci was considered the most important feature.Other features,although they accounted for a relatively small proportion,also had an impact on the vault prediction.After parameter optimization,the best prediction results were obtained,with a predicted mean value of 763.688μm and an actual mean value of 776.9304μm.The R²was 0.4456 and the root mean square error was 201.5166.CONCLUSION:A study based on UBM images using random forest network can be performed for prediction of the vault after ICL implantation and can provide some reference for ICL size selection.展开更多
Dear Editor,We are writing this letter to report two unusual cases of femtosecond laser-assisted cataract surgery(FLACS)in two ICL-implanted patients with significant different vault.FLACS has been confirmed by accumu...Dear Editor,We are writing this letter to report two unusual cases of femtosecond laser-assisted cataract surgery(FLACS)in two ICL-implanted patients with significant different vault.FLACS has been confirmed by accumulating evidence to improve the safety and precision of surgery from common cases to complicated cases in treating cataracts[1-3].Implantable collamer lens(ICL)implantation possesses a good performance in its predictability,reversibility,and the rapid visual recovery.展开更多
The bone defects of the cranial vault encompassed rare malformations including acalvaria, hypocalvaria, acrania, hypocrania, anencephaly and exencephaly. They are also described in some pathological entities such as a...The bone defects of the cranial vault encompassed rare malformations including acalvaria, hypocalvaria, acrania, hypocrania, anencephaly and exencephaly. They are also described in some pathological entities such as aplasia cutis congenita of the scalp. We report an unusual case of cephalic malformation which combine defects of the skin, the dura mater, and the bones of the vault, with a malformation of the central nervous system. This unique case emphasizes a problem of nosological definition between the terms mentioned above. acalvaria, the acrania, the hypocalvaria and the aplasia cutis congenita. Thus, herein, we proceed to a literature review of bone defects of the skull and their differential diagnosis.展开更多
AIM:To compare the agreement of anterior chamber depth(ACD)and central vault measurements obtained by anterior segment optical coherence tomography(AS-OCT)and ultrasound biomicroscopy(UBM)of post surgical high ...AIM:To compare the agreement of anterior chamber depth(ACD)and central vault measurements obtained by anterior segment optical coherence tomography(AS-OCT)and ultrasound biomicroscopy(UBM)of post surgical high myopic eyes with posterior chamber phakic intraocular lens(Visian ICL;STAAR Surgical)implantation.·METHODS:Fifty-two phakic eyes of 28 high myopic patients who underwent implantable Collamer lens(ICL)surgery for the correction of high myopia were studied.The postoperative ACD,the distance between the corneal endothelium and the anterior surface of ICL(cornea-ICL)and the central vault were measured with the AS-OCT system and the UBM system.Intraclass correlation coefficient(ICC)and the Bland-Altman plot were used to evaluate the repeatability and agreement of two devices.·R ESULTS:The mean ACD,cornea-ICL and central vault in the 52 phakic eyes after ICL surgery was 3.19±0.28 mm,2.47±0.28 mm,0.50±0.19 mm by AS-OCT and3.13±0.25 mm,2.49±0.25 mm,0.44±0.19 mm by UBM,respectively.Pairwise comparison of ACD and central vault measurements showed significant differences between AS-OCT and UBM(〈0.05).However,no statistically significant difference was found between these imaging techniques in cornea-ICL(〉0.05).The Pearson correlation coefficient()between AS-OCT and UBM measurements for ACD,cornea-ICL and vault was0.88,0.80 and 0.89,respectively(〈0.001).The ICC was0.89-0.94 for the measurements of AS-OCT and UBM.Bland-Altman analysis showed the 95%limits of agreement of ACD,cornea-ICL,central vault measurements between these two devices were-0.20 to 0.32 mm,-0.36to 0.32 mm and-0.12 to 0.24 mm,respectively.58·CONCLUSION:Central ACD and vault measurements using AS-OCT demonstrated a slight significantly higher value than using UBM in phakic eyes after ICL surgery.These two devices should not be used interchangeably for measurements of central ACD and vault in patients after phakic intraocular lens implantation.展开更多
基金Supported by National Natural Science Foundation of China(No.81900910)Natural Science Foundation of Zhejiang Province(No.LQ19H120003)Basic Scientific Research Project of Wenzhou(No.Y2023809).
文摘AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants underwent ICL surgery and were divided into the low(<250μm)and normal(250-1000μm)vault groups based on the postoperative vault at 3mo.The preoperative biometric parameters and clinical outcomes were compared between the two groups.The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized estimating equations.RESULTS:Sixteen(23 eyes)and 36 patients(63 eyes)were in the low and normal vault groups,respectively.All implantation procedures were uneventful with no cataract formation in the early postoperative period.The sulcusto-sulcus lens rise(STSL)and iris ciliary angle(ICA)were correlated with vault at 3mo after surgery.Every 0.1 mm increase in STSL was associated with 38.9μm decrease in the postoperative 3-month vault.A rise of 1 degree in ICA is associated with a reduction of 4μm in vault.CONCLUSION:Eyes with a narrow ciliary sulcus are associated with a higher rate of low vault after ICL implantation,suggesting a need for adjustments to the ICL size in these patients.Evaluating the characteristics of the ciliary sulcus contributes valuable information to predict low vault after surgery.
文摘AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images were collected from the Lixiang Eye Hospital to provide the patient’s preoperative parameters as well as the vault of the ICL after implantation.The vault was set as the prediction target,and the input elements were mainly ciliary sulcus shape parameters,which included 6 angular parameters,2 area parameters,and 2 parameters,distance between ciliary sulci,and anterior chamber height.A random forest regression model was applied to predict the vault,with the number of base estimators(n_estimators)of 2000,the maximum tree depth(max_depth)of 17,the number of tree features(max_features)of Auto,and the random state(random_state)of 40.0.RESULTS:Among the parameters selected in this study,the distance between ciliary sulci had a greater importance proportion,reaching 52%before parameter optimization is performed,and other features had less influence,with an importance proportion of about 5%.The importance of the distance between the ciliary sulci increased to 53% after parameter optimization,and the importance of angle 3 and area 1 increased to 5% and 8%respectively,while the importance of the other parameters remained unchanged,and the distance between the ciliary sulci was considered the most important feature.Other features,although they accounted for a relatively small proportion,also had an impact on the vault prediction.After parameter optimization,the best prediction results were obtained,with a predicted mean value of 763.688μm and an actual mean value of 776.9304μm.The R²was 0.4456 and the root mean square error was 201.5166.CONCLUSION:A study based on UBM images using random forest network can be performed for prediction of the vault after ICL implantation and can provide some reference for ICL size selection.
基金Supported by Key Research and Development Program of Shaanxi Province(No.2020SF-271,No.2017SF-273)。
文摘Dear Editor,We are writing this letter to report two unusual cases of femtosecond laser-assisted cataract surgery(FLACS)in two ICL-implanted patients with significant different vault.FLACS has been confirmed by accumulating evidence to improve the safety and precision of surgery from common cases to complicated cases in treating cataracts[1-3].Implantable collamer lens(ICL)implantation possesses a good performance in its predictability,reversibility,and the rapid visual recovery.
文摘The bone defects of the cranial vault encompassed rare malformations including acalvaria, hypocalvaria, acrania, hypocrania, anencephaly and exencephaly. They are also described in some pathological entities such as aplasia cutis congenita of the scalp. We report an unusual case of cephalic malformation which combine defects of the skin, the dura mater, and the bones of the vault, with a malformation of the central nervous system. This unique case emphasizes a problem of nosological definition between the terms mentioned above. acalvaria, the acrania, the hypocalvaria and the aplasia cutis congenita. Thus, herein, we proceed to a literature review of bone defects of the skull and their differential diagnosis.
文摘AIM:To compare the agreement of anterior chamber depth(ACD)and central vault measurements obtained by anterior segment optical coherence tomography(AS-OCT)and ultrasound biomicroscopy(UBM)of post surgical high myopic eyes with posterior chamber phakic intraocular lens(Visian ICL;STAAR Surgical)implantation.·METHODS:Fifty-two phakic eyes of 28 high myopic patients who underwent implantable Collamer lens(ICL)surgery for the correction of high myopia were studied.The postoperative ACD,the distance between the corneal endothelium and the anterior surface of ICL(cornea-ICL)and the central vault were measured with the AS-OCT system and the UBM system.Intraclass correlation coefficient(ICC)and the Bland-Altman plot were used to evaluate the repeatability and agreement of two devices.·R ESULTS:The mean ACD,cornea-ICL and central vault in the 52 phakic eyes after ICL surgery was 3.19±0.28 mm,2.47±0.28 mm,0.50±0.19 mm by AS-OCT and3.13±0.25 mm,2.49±0.25 mm,0.44±0.19 mm by UBM,respectively.Pairwise comparison of ACD and central vault measurements showed significant differences between AS-OCT and UBM(〈0.05).However,no statistically significant difference was found between these imaging techniques in cornea-ICL(〉0.05).The Pearson correlation coefficient()between AS-OCT and UBM measurements for ACD,cornea-ICL and vault was0.88,0.80 and 0.89,respectively(〈0.001).The ICC was0.89-0.94 for the measurements of AS-OCT and UBM.Bland-Altman analysis showed the 95%limits of agreement of ACD,cornea-ICL,central vault measurements between these two devices were-0.20 to 0.32 mm,-0.36to 0.32 mm and-0.12 to 0.24 mm,respectively.58·CONCLUSION:Central ACD and vault measurements using AS-OCT demonstrated a slight significantly higher value than using UBM in phakic eyes after ICL surgery.These two devices should not be used interchangeably for measurements of central ACD and vault in patients after phakic intraocular lens implantation.