期刊文献+
共找到1,270篇文章
< 1 2 64 >
每页显示 20 50 100
Endovenous laser treatment vs conventional surgery for great saphenous vein varicosities: A propensity score matching analysis
1
作者 Qiang Li Chen Zhang +2 位作者 Zhao Yuan Zi-Qi Shao Jian Wang 《World Journal of Clinical Cases》 SCIE 2023年第35期8291-8299,共9页
BACKGROUND Varicosis is a common venous condition,which is typically treated surgically.However,selection of the optimal surgical approach can be challenging.Previous studies comparing endovenous laser treatment(EVLT)... BACKGROUND Varicosis is a common venous condition,which is typically treated surgically.However,selection of the optimal surgical approach can be challenging.Previous studies comparing endovenous laser treatment(EVLT)and conventional surgery were retrospective and observational in nature and the results may therefore have been influenced by selection bias and the presence of other confounding factors.In this study,we used propensity score matching to reduce selection bias when comparing EVLT and conventional surgery for the treatment of varicose great saphenous veins.METHODS We retrospectively reviewed the records of 1063 patients treated for primary varicosis of the great saphenous vein at the Second Affiliated Hospital of Xuzhou Medical University between January 2009 and December 2019.Among them,56 patients were excluded owing to additional small saphenous varicose vein involvement,81 owing to recurring varicose veins,83 owing to complicated varicose veins(CEAP clinical classification C5-C6),and 6 owing to perioperative phlebitis.Finally,772 patients were enrolled in this study.Standard demographic and clinicopathological data were collected from the medical records of the patients.For propensity score matching,522 patients(261 who underwent EVLT and 261 who underwent conventional surgery)were randomly matched 1:1 by age,sex,onset time,smoking status,presence of diabetes,family history,stress therapy,C class,and the affected leg.RESULTS Of the 772 patients included in the study,467 underwent EVLT and 305 underwent conventional surgery.There were significant differences in age,onset time,smoking and diabetes status,and family history between the two groups.Following propensity score matching,no significant differences in patients’characteristics remained between the two groups.ELVT was associated with a shorter operation time and hospital stay than conventional surgery,both before and after propensity score matching.There were no differences in complications between the two groups after propensity score matching.Patients who underwent EVLT had a higher recurrence rate during the two-year follow-up period than those who underwent conventional surgery(33.33%vs 21.46%,χ^(2)=11.506,P=0.001),and a greater percentage of patients who underwent EVLT experienced pain one week after the procedure(39.85%vs 19.54%,P=0.000).CONCLUSION EVLT may not always be the best option for the treatment of great saphenous vein varicosis. 展开更多
关键词 Endovenous laser treatment Conventional surgery great saphenous vein Propensity score matching OUTCOMES Varicosis
下载PDF
VNUS Closure<sup>®</sup>FAST Radiofrequency of the Great Saphenous Vein for Superficial Venous Insufficiency: Experience of the CH of Cholet in France
2
作者 Birama Togola Laurent Muller +10 位作者 Bréhima Bengaly Drissa Traoré Drissa Ouattara Cheick Sekou Ahmed Touré Mahamadou Coulibaly Abdoulaye Kanté Hamadoun Dicko Boubacar Diallo Michel Peret Nouhoum Ongoiba Jean Louis Debrux 《World Journal of Cardiovascular Surgery》 2021年第5期43-50,共8页
<b>Background:</b>The objective of this work was to evaluate the first results of the radio ablation of the great saphenous vein in the processing of chronic venous insufficiency. <b>Method: </b&g... <b>Background:</b>The objective of this work was to evaluate the first results of the radio ablation of the great saphenous vein in the processing of chronic venous insufficiency. <b>Method: </b>This is a monocentric retrospective study of radio ablation of the great saphenous vein using VNUS Closure<sup>®</sup> FAST for superficial venous insufficiency of the great saphenous vein, between January 2012 and December 2014. <b>Results:</b> 42 patients (57 limbs) were operated on with this technology. There were 33 women and 9 men (mean age: 46.5 years). Thirty-nine patients (92. 8%) were symptomatic. Thirty-two patients (76.1%) were classified CEAP 2. The average diameter of the saphenous vein was 8.5 ± 1.5 mm. Three patients (7.1%) had a percutaneous approach. A perfect occlusion of the saphenous vein was observed in all patients. No incident or undesirable event was observed during the procedure. One case of delayed deep-vein thrombosis was observed. At one month of follow-up, six patients (14.2%) had induration opposite to the occluded vein. Forty-three percent of the pati<span style="letter-spacing:-0.1pt;">ents stated they were very satisfied with the procedure. <b>Conclusion:</b> The effectiveness, security and simplicity of the closure method are real. More studies are necessary to assess the long-term results of this procedure.</span> 展开更多
关键词 VARICOSE great saphenous vein Endovenous Therapy Radiofrequency Ablation
下载PDF
Higher Energy Does Not Mean Better Outcome Following Endovenous Laser Ablation of Great Saphenous Vein
3
作者 Celalettin Karatepe Mustafa Aldemir +3 位作者 Bayer Cinar Akif Onalan Halim Issever Onur S.Goksel 《World Journal of Cardiovascular Surgery》 2014年第11期200-205,共6页
Background: Endovenous laser ablation is a relatively newer alternative to treat great saphenous vein insufficiency. We evaluated the efficiency and safety of treatment endovenous laser procedures on the different sap... Background: Endovenous laser ablation is a relatively newer alternative to treat great saphenous vein insufficiency. We evaluated the efficiency and safety of treatment endovenous laser procedures on the different saphenous vein diameters with different energy levels. Methods: Data regarding endovenous laser ablation of symptomatic chronic great saphenous venous insufficiency in 209 patients were prospectively recorded. Patients were grouped into two main groups based on their diameters as 5 to 7 millimeters (Group A) or more than 7 millimeters (Group B). Patients in each group was randomized into two groups as >90 J/cm (A1 and B1) or 80-90 J/cm (A2 and B2). Postoperative outcome and complications were recorded during follow-ups at 1st week;1st, 3rd and 6th months to examine the venous reflux and recanalization. Results: Perioperative complaints as pain, cramps and ankle swelling were more commonly observed in A1 group. Fatigue was more common in A2 and B2 groups. No major complications as deep vein thrombosis or skin burns were observed. Conclusions: Endovenous laser ablation is a safe and effective procedure with a high satisfaction rate shortening hospitalization durations and early ambulant activity. Pain, ankle swelling and fatigue are the most common minor complaints in the early postoperative period. 展开更多
关键词 Endovenous Laser Ablation great saphenous vein VARICES
下载PDF
Revascularization for Iliac-femoral Artery Pseudoaneurysm with Greater Saphenous Vein 被引量:4
4
作者 Ji-dong Wu Yue-hong Zheng +1 位作者 Nim Choi Furtado Rui 《Chinese Medical Sciences Journal》 CAS CSCD 2010年第1期57-60,共4页
Objective To investigate the role of revascularization procedures with autologous greater saphenous vein in surgical management of iliac-femoral artery pseudoaneurysm in parenteral drug abusers. Methods Twenty-one pat... Objective To investigate the role of revascularization procedures with autologous greater saphenous vein in surgical management of iliac-femoral artery pseudoaneurysm in parenteral drug abusers. Methods Twenty-one patients with iliac-femoral artery pseudoaneurysm caused by parenteral drug abuse from 2004 to 2007 were enrolled. Among them,15 patients were male and 6 were female; their average age was 31.3 years. The size of pseudoaneurysms ranged from 3.0 cm to 7.5 cm. Common femoral artery and distal external iliac artery were often involved. We performed arterial reconstruction on these patients with autologous greater saphenous vein as a graft after excising iliac-femoral artery pseudoaneurysm through a single curved inguinal incision. All patients were followed up,and the complications were recorded. Results The surgical procedures were finished without intraoperative mortality or perioperative complications. All patients were free of claudication symptoms after the surgery except one case with preoperative popliteal artery stenosis. One case of infection and wound tissue fistula was found later. One case had inguinal incisional hematoma and another complained of numbness in thigh skin. Conclusions The use of autologous greater saphenous venous grafts for arterial reconstruction after pseudoaneurysm excision in drug abusers is safe and effective. This technique offers more advantages than arterial ligation alone without revascularization. An optimal greater saphenous venous graft is a prerequisite for revascularization. 展开更多
关键词 静脉移植 动脉瘤 血管化 假性 手术治疗 自体移植 药物滥用 平均年龄
下载PDF
Retrograde percutaneous coronary intervention via critically degenerated saphenous vein grafts for chronic total occlusion in native coronary arteries 被引量:4
5
作者 Makoto Sekiguchi Masao Yamazaki Masahiko Kurabayashi 《World Journal of Cardiovascular Diseases》 2013年第3期261-265,共5页
We report the case of a 78-year-old woman with saphenous vein graft (SVG) disease and chronic total occlusion (CTO) in three native coronary arteries [left anterior descending artery (LAD), left circumflex artery, and... We report the case of a 78-year-old woman with saphenous vein graft (SVG) disease and chronic total occlusion (CTO) in three native coronary arteries [left anterior descending artery (LAD), left circumflex artery, and the right coronary artery], who was successfully treated by percutaneous coronary intervention (PCI) using the retrograde approach via the critically degenerated SVGs. The patient, a 78-year-old woman, presented with sudden chest pain and dyspnea. She had previously undergone coronary artery bypass surgery using SVGs for the three vessels and percutaneous coronary intervention with sirolimuseluting stent placement in the posterolateral branch 13 and 3 years ago, respectively. Electrocardiography revealed ST-segment elevation in leads V1-4, whereas emergent coronary angiography revealed total occlusion in her native coronary arteries. Primary PCI was scheduled. A channel dilator was advanced very smoothly and safely into the distal site of the CTO lesion in the LAD, which showed complete occlusion in the proximal region, via an SVG that was temporally occluded four days earlier. A reverse controlled antegrade and retrograde tracking technique was used to successfully perform percutaneous recanalization. Subsequently, the other two native CTO lesions protected by critically degenerated SVGs were treated with retrograde intervention via the SVGs. The retrograde approach via critically degenerated SVGs is safe, reliable, and fast. If an SVG bypassing the native CTO lesion is critically degenerated, percutaneous coronary intervention should be performed via the SVG. 展开更多
关键词 PERCUTANEOUS Coronary Intervention Total OCCLUSION saphenous vein GRAFTS
下载PDF
Percutaneous recanalization of total saphenous vein graft occlusion with excimer laser treatment 被引量:2
6
作者 Yuan HAN Quan-Min JING +2 位作者 Qian-Cheng WANG Yan-Bin SU Guo-Jun CHEN 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2020年第4期234-240,共7页
Patients presenting with recurrence of anginal symptoms after saphenous vein bypass surgery pose an increasingly frequent challenge.In general,approximately 40%to 50%of saphenous vein graft(SVG)will become diseased or... Patients presenting with recurrence of anginal symptoms after saphenous vein bypass surgery pose an increasingly frequent challenge.In general,approximately 40%to 50%of saphenous vein graft(SVG)will become diseased or occluded within the first ten years after surgery.[1]Because adverse clinical outcomes,such as high restenosis rates and distal embolization,have been reported,percutaneous coronary intervention(PCI)for SVG is not recommended as a first-line strategy.[2]Distal embolization occurs in 2%–17%of patients despite advances in therapy,including the utilization of embolic protection device(EPD),which may lead to increased mortality at both short follow-up and midterm follow-up.[3]However,these patients often associated with inappropriate anatomic characteristics of native vessel intervention including calcification,tortuosity,abundant plaque burden,and complex chronic total occlusion(CTO)lesions.Moreover,repeat coronary bypass surgery is an option but is technically more demanding and is associated with a higher mortality.Therefore,it can sometimes result in SVG stenosis being the only intervention option.This is why the recanalization of SVG lesions,especially totally occluded lesions,remains one of the most challenging procedures in interventional cardiology. 展开更多
关键词 EXCIMER laser PERCUTANEOUS CORONARY intervention saphenous vein GRAFT
下载PDF
A Comparative Analysis on Surgical Outcomes and Complications of Endoscopic and Open Vein Harvesting Techniques
7
作者 Mohammed Fawzy Eltaweel Ismail N. El-Sokkary +7 位作者 Ahmed Alherazi Mohamed Wael Badawi Mohammed G. Abdellatif Bahaa A. Elkhonezy Ibrahim K. Gamil Haytham Mohamed Abd El Moaty Sarra Sadmi Mahmoud Khalil 《Open Journal of Thoracic Surgery》 2024年第2期29-39,共11页
Objective: The great saphenous vein (GSV) is commonly used as a conduit for grafting during CABG surgery, and open GSV harvesting (OVH), commonly used with long incision to expose the vein. However, endoscopic vein ha... Objective: The great saphenous vein (GSV) is commonly used as a conduit for grafting during CABG surgery, and open GSV harvesting (OVH), commonly used with long incision to expose the vein. However, endoscopic vein harvesting (EVH) is an alternative approach, utilizing specialized instruments and small incisions to harvest the vein. Methods: A retrospective analysis was conducted on a cohort of patients who underwent Coronary artery bypass graft (CABG) requiring great saphenous vein (GSV) harvesting which was done by EVH or OVH procedures. Demographic variables, including age and gender, were assessed for both groups. Intraoperative variables such as the number of grafts, cardiopulmonary bypass time, X clamp time, and type of procedure were analyzed. Postoperative variables, including infection and bleeding rates, were also evaluated. Results: The study included 30 patients each undergoing Coronary artery bypass graft (CABG) with need of great saphenous vein harvesting which was done by EVH and OVH. Demographic variables were well-matched between the two groups in terms of age, while a significant difference in gender distribution was observed. Obesity and smoking were more prevalent in the OVH group, and EVH was associated with a higher mean number of grafts compared to OVH. Conversion to an open technique occurred in a portion of the EVH cases, and infection rates did not significantly differ between the EVH and OVH groups. However, the incidence of postoperative bleeding was significantly higher in the EVH group. Conclusion: This study provides valuable insights into the demographic, intraoperative, and postoperative variables associated with EVH and OVH techniques. EVH demonstrated advantages in terms of reduced infection rates compared to OVH. However, the higher incidence of postoperative bleeding associated with EVH raises concerns about potential risks. 展开更多
关键词 Endoscopic vein Harvesting (EVH) Open vein Harvesting (OVH) Coronary Artery Bypass Grafting (CABG) great saphenous vein (GSV) Surgical Outcomes
下载PDF
Glabridin Relaxes Vascular Smooth Muscles by Activating BK_(Ca) Channels and Inhibiting Phosphodiesterase in Human Saphenous Vein 被引量:2
8
作者 Cengiz Giüven Ali Parlar 《Current Medical Science》 SCIE CAS 2021年第2期381-389,共9页
The aim of the current study was to investigate the pharmacological activity of glabridinon the isolated human saphenous vein (SV) and explore the underlying mechanisms. Samples of patients' SVs were removed durin... The aim of the current study was to investigate the pharmacological activity of glabridinon the isolated human saphenous vein (SV) and explore the underlying mechanisms. Samples of patients' SVs were removed during bypass surgery, and 4-mm lengths of the vessels were placedin Krebs solution at ±4℃ and hung in an isolated organ bath to assess their contraction/relaxationresponses. The contraction/relaxation responses were recorded to observe if the cyclic guanosinemonophosphate (cGMP)/protein kinase G (PKG) pathway mediates the relaxant effect of glabridinafter treatment with blockers like ODQ (a guanylate cyclase inhibitor), KT5823 (a PKG inhibitor),isobutylmethylxanthine [IBMX, a phosphodiesterase (PDE) inhibitor], and cantharidin [Cant,a myosin light-chain phosphatase (MLCP) inhibitor]. Moreover, nitric oxide (NO), cGMP, andPKG levels in SV tissues were determined by ELISA after incubation with glabridin, N(o)-nitro-L-arginine methyl ester (L-Name, a NO synthetase inhibitor), phenylephrine (PE), ODQ, IBMX,and KT5823. The results showed that glabridin relaxed the vascular smooth muscle of humanSV pretreated with PE in a dose-dependent manner, which was independent of the endothelium.The vasorelaxant effect of glabridin was only inhibited by iberiotoxin (IbTX), Cant, and KT5823.Glabridin increased cGMP and PKG levels in SV homogenates, whereas it did not alter the NOlevel. The enhancing efects of cGMP and PKG levels by glabridin were abolished by ODQ andKT5823. In conclusion, glabridin has a vasorelaxant effect, which is associated with the activationof BKc. channels and inhibition of PDE. 展开更多
关键词 GLABRIDIN BKCa channels human saphenous vein(SV)grafts cyclic guanosine monophosphate(cGMP) protein kinase G(PKG)
下载PDF
Effect of Troglitazone on Expression of Adhesion Molecules and eNOS in Human Saphenous Vein Gaft
9
作者 陈澍 胡志伟 +2 位作者 张凯伦 苏伟 孙宗全 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2007年第6期657-659,共3页
To investigate whether peroxisome proliferators-activated receptor-γ (PPARγ) ligand Troglitazone can reduce endothelial injury and activation during storage of harvested saphenous vein grafts. Segments of human sa... To investigate whether peroxisome proliferators-activated receptor-γ (PPARγ) ligand Troglitazone can reduce endothelial injury and activation during storage of harvested saphenous vein grafts. Segments of human saphenous vein graft were collected from 9 patients undergoing coronary bypass surgery and then divided into two equal parts of control and test specimens, were stored in ei- ther heparinized blood (control group) or heparinized blood containing 20 μmol/L troglitazone (test group) for 1 h at room temperature. Tissue distribution and protein expression of VCAM-I, ICAM-I, and endothelial nitric oxide synthase (eNOS) were compared using immunohistochemistry and Western blot analysis. Myeloperoxidase (MPO) activity, a marker of neutrophil sequestration in human saphenous vein grafts, was also measured in each group. The expression of ICAM-1 (753±132 versus 7201±934; P〈0.01) , VCAM-1 (3731±294 versus 8292±793; P〈0.01), and MPO activity (1.52±0.42 U/g, 5.04±1.26 U/g P〈0.01) were significantly lower in test group. In contract, eNOS expression (7983±834 versus 3989±1008; P〈0.01) was significantly higher in test group. PPARγ ligand troglitazone might reduce endothelial injury during the storage period of human saphenous vein grafts. 展开更多
关键词 TROGLITAZONE adhesion molecule endothelial nitric oxide synthase saphenous vein GRAFT
下载PDF
Effects of Levosimendan on Hydrogen Peroxide Induced Contraction in Human Saphenous Vein
10
作者 Burak Cem Soner Ayse Saide Sahin +1 位作者 Ipek Duman Niyazi Gormus 《Pharmacology & Pharmacy》 2011年第4期233-237,共5页
Aim: Increased oxidative stress plays important roles in vascular dysfunction in patients undergoing coronary artery bypass graft surgery. Hydrogen peroxide (H2O2) is used as an experimental model for oxidative stress... Aim: Increased oxidative stress plays important roles in vascular dysfunction in patients undergoing coronary artery bypass graft surgery. Hydrogen peroxide (H2O2) is used as an experimental model for oxidative stress. The present study was designed to assess the effects of levosimendan pretreatment on the contractile effects induced by H2O2 in human saphenous vein (HSV) segments. Methods: We studied H2O2 induced contractions of isolated HSV mounted in standard tissue baths. H2O2 (10-6 – 10-3 M) was added cumulatively to the organ bath. Concentration-response curves to H2O2 were repeated in the presence of levosimendan (10–8 M). In the second series of experiments, strips were contracted with 5-HT (10–5 M). When the contraction reached a stable plateau, H2O2 was administrated cumulatively into the organ bath. The same procedure was conducted in the presence of levosimendan. Results: Pretreatment of the SV strips with levosimendan significantly reduced the contractile response to each concentration of H2O2 . 5-HT produced contractions in SV strips. Further treatment of these strips with H2O2 resulted in statistically significant concentration-dependent increases in tension. Preincubation of the tissues with levosimendan did not significantly influence the maximum amplitude of the 5-HT-induced tone but inhibited the contractile effect of H2O2 on the 5-HT-induced contraction. Conclusion: Pretreatment of HSV with clinical concentrations of levosimendan inhibits the vasoconstriction caused by oxidative stress, indicating its potential preventive effect against oxidative stress induced graft spasm. 展开更多
关键词 HYDROGEN PEROXIDE Human saphenous vein LEVOSIMENDAN
下载PDF
Morbidity of Open Saphenous Vein Harvesting after Preoperative Ultrasonic Mapping
11
作者 Susumu Isoda Tamizo Kimura +6 位作者 Katsunori Tanaka Kenji Nishimura Nozomu Yamanaka Shin-ichi Taguchi Keiji Uchida Norihisa Karube Kiyotaka Imoto 《Open Journal of Thoracic Surgery》 2015年第1期4-9,共6页
Preoperative echography of a saphenous vein graft (SVG) was studied. In 58 cases of consecutive coronary artery bypass grafting, 31 patients underwent SVG echography. Preoperative assessment revealed vein caliber, bra... Preoperative echography of a saphenous vein graft (SVG) was studied. In 58 cases of consecutive coronary artery bypass grafting, 31 patients underwent SVG echography. Preoperative assessment revealed vein caliber, branching, or varicose saphenous veins. The location of the saphenous vein was marked. Saphenous veins were harvested by the open harvest technique, and the caliber of the veins and the availability of the anastomosis device were recorded. Postoperative morbidity was recorded. Preoperative findings revealed that four (6.5%) of 62 femoral saphenous veins were estimated as “not graftable” because of being a varicose vein or having a small caliber. Seven of 32 lower saphenous veins were estimated as “not graftable”. The mean discrepancy of the caliber was 0.6 mm undersized with preoperative estimation. During harvesting, one of 31 patients had a wrong marking. We were able to use all harvested veins. The morbidity of saphenous harvesting was observed in two (6.5%) of 31 patients. One patient whose marking was wrong had minor skin necrosis. Another patient experienced a hematoma because of the excess effect of warfarin. Preoperative ultrasonic mapping of the saphenous vein reduced useless harvesting, provided information concerning anastomosis device availability, and seemed to reduce morbidity because dissection can be minimal. 展开更多
关键词 saphenous vein ULTRASONIC MAPPING Coronary Artery BYPASS Grafting
下载PDF
Cutaneous Manifestations at Saphenous Vein Harvest Site among Iraqi Patients with Coronary Artery Bypass Graft
12
作者 Khalifa E. Sharquie Adil A. Noaimi Ali S. Alaboudi 《Journal of Cosmetics, Dermatological Sciences and Applications》 2012年第1期32-37,共6页
Background: Coronary artery bypass grafting (CABG) has become a common surgical procedure and increasingly done in Iraq. The greater saphenous vein (GSV) is the most veins often used as the conduit and its complicatio... Background: Coronary artery bypass grafting (CABG) has become a common surgical procedure and increasingly done in Iraq. The greater saphenous vein (GSV) is the most veins often used as the conduit and its complications include a variety of cutaneous manifestations. Objective: To report the cutaneous manifestations at the saphenous vein harvesting site in Iraqi patients who undergone CABG. Methods: A total of 100 (82 males, 18 females) patients who had undergone CABG using the saphenous vein (SV) harvested by longitudinal incision open technique at the legs and/ or thighs were included in this case descriptive study. All cases were seen at least two months after the time of the operation in the outpatient clinic of the Cardiac Surgery Department in the Ibn-Albitar Hospital during October 2009 - October 2010. A detailed history and close dermatological examination were done including all related points to their problems. Results: The cutaneous changes on and around the saphenous vein (SV) graft donor scars were noticed in 60 out of 100 patients, 49 (81.66%) males and 11 (18.33%) females, their ages ranged from 32 - 74 (59.38±8.3221) years, with body mass index (BMI)ranged from 21.8746 - 26.9057 (23.875±8.5378). The duration interval between the time of CABG and presentation ranged from 2-180 months with a median of 5 months, 36 (60%) patients presented at less than 6 months and 24 (40%) patients presented at more than 6 months. Anesthesia was the predominant presenting symptom in 49 (81.6%), followed by neurolgic pain 8 (13.3%) and pruritus 2 (3.3%), while the cutaneous signs recorded at the site of SVG were: Xerosis in 17 (28.3%) patients, followed by residual hyperpigmentation 11(18.3%), depigmentation 11(18%), recent hair loss 11 (16.6%), hypertrophic scar 8 (13.3%), non-healing ulcer 7 (11.6%), lymphedema 7 (11.6%) and neuropathy dermatitis 6 (10%). Conclusions: Cutaneous manifestations following coronary artery bypass surgery are not uncommon problem in Iraqi patients that are seen at area of saphenous vein harvesting but the most interesting thing is to report the neuropathy dermatitis. 展开更多
关键词 CUTANEOUS MANIFESTATIONS saphenous vein CABG
下载PDF
Radial Artery and Saphenous Vein Grafts in Coronary Artery Bypass Surgery Comparison in Terms of Patient Symptoms
13
作者 Tugra Gencpinar Koray Aykut +4 位作者 Gokhan Albayrak Umut Ayoglu Muzaffer Yilmaz Kadir Sagdic Mustafa Emmiler 《World Journal of Cardiovascular Surgery》 2014年第4期43-46,共4页
Background: The aim of this study is to compare radial artery with saphenous vein grafts which are widely used for coronary bypass, from views of patients’ satisfaction and postoperative findings. Methods: 42 isolate... Background: The aim of this study is to compare radial artery with saphenous vein grafts which are widely used for coronary bypass, from views of patients’ satisfaction and postoperative findings. Methods: 42 isolated coronary bypass (CABG) patients performed during November 2012-April 2013 are included in the study. 30 days after the operation, in patients who had both RA and SV removal made responses to a questionnaire form which included 6 questions about symptoms of extremity. Results: After analyzing the responses and physical examination, there was no difference in terms of quality of life and usefulness of the extremity for daily use between two grafts. 2 patients (2%) have wound infection on the saphenous vein incision and additional surgical procedure was performed and a scar tissue has occurred. There was no statistically significance between uncomfortable symptoms and demographic data. Conclusion: Our study suggested that RA graft using showed a bit more comfortable and suitable effect against SV in our patients. We think that radial arterial grafts should be used more widely in coronary surgery with selected patients. 展开更多
关键词 Radial Artery saphenous vein Coronary Artery Bypass Grafting
下载PDF
Endovenous laser ablation of great saphenous vein with ultrasound-guided perivenous tumescence: early and midterm results 被引量:5
14
作者 CHEN Jia-quan XIE Hui DENG Hao-yu YUAN Kai ZHANG Ji-wei ZHANG Hao ZHANG Lan 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第3期421-425,共5页
Background Endovenous laser ablation (EVLA) is an improved method to treat varicose great saphenous veins (GSV) with a high satisfactory rate. This study aimed to evaluate the efficiency and safety of treatment by... Background Endovenous laser ablation (EVLA) is an improved method to treat varicose great saphenous veins (GSV) with a high satisfactory rate. This study aimed to evaluate the efficiency and safety of treatment by EVLA procedures with ultrasound-guided perivenous tumescence. Methods Thirty-one patients (31 limbs) with symptomatic varicose vein primary to chronic venous insufficiency (CVI) treated with EVLA were prospectively studied. The entire procedure was performed under ultrasound-guided tumescent local anesthesia. The patients were evaluated with a 18 month follow-up postoperation using clinical examination and venous duplex ultrasonography. Pain scores and quality of life (QOL) were recorded using visual analog scale (VAS) and the chronic venous insufficiency questionnaire (CIVIQ) at 1 week, 1 month, and 12 months after operation. Results All patients tolerated EVLA procedure well. The overall success occlusion rates of GSV were 92%, 94%, and 94% at 1, 12, and 18 months follow-up, respectively. The score of CIVIQ one week preoperation was 69.14±11.44 while that of CIVIQ one month postoperation was 85.32±4.89. The life quality has significantly improved after the operation of EVLA (t=12.71, P 〈0.05). The VAS one month after treatment was lower than 1 week before therapy (t=8.048, P 〈0.05). Major complications such as deep vein thrombosis and skin burns were not found. Most of the complications were minor and improved quickly. Conclusions This refinement type of EVLA procedure is a safe and effective treatment with a high satisfaction rate; it displayed noteworthy features including shortening hospitalization, early ambulant activity, and preferable occlusion rates. 展开更多
关键词 endovenous laser ablation great saphenous vein OCCLUSION tumescent anaesthesia
原文传递
A huge thrombosed aneurysm of a saphenous vein graft leading to compression of cardiac structures: role of multimodality imaging
15
作者 Byung Gyu Kim In-Cheol Kim +1 位作者 Seok-Min Kang Young-Nam Youn 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2017年第8期536-537,共2页
关键词 静脉移植 动脉瘤 心脏结构 成像 多模态 血栓性 压缩 冠状动脉
下载PDF
Anatomic Dissection of the Femoral Vein at the Bamako Anatomy Laboratory
16
作者 Babou Ba Abdoulaye Kanté +6 位作者 Tata Touré Moumouna Koné Fousseyni Guissé Drissa Traoré Tièman Coulibaly Nouhoun Ongoiba A.K.Koumare 《Forensic Medicine and Anatomy Research》 2019年第4期76-84,共9页
Objectives: The purpose of this work was to measure the dimensions of the femoral veins, to describe the affluent and the variations of the femoral veins. Methodology: Twenty-four femoral veins of 12 fresh adult cadav... Objectives: The purpose of this work was to measure the dimensions of the femoral veins, to describe the affluent and the variations of the femoral veins. Methodology: Twenty-four femoral veins of 12 fresh adult cadavers were dissected and photographed. Results: The diameter of the superficial, deep and common femoral veins was respectively 8.75 mm;7.60 mm and 13.95 mm. The common femoral vein was 80.70 mm long. At the level of the superficial vein, the modal disposition was noted in 79.17%;as anatomical variations, it was split in 2 cases, the presence of a collateral canal in 1 case and in 2, and it received a quadricipital muscle vein. At the level of the deep femoral vein, the modal disposition was noted in 16.67%, and the anatomical variations were noted in 83.33% where it received no affluent in the femoral trine. The modal disposition was noted in 91.67% at the level of the mode of birth of the common femoral vein, in 16.67% at the level of its tributaries. The anatomical variations were noted in 8.33% in the mode of birth of the femoral vein, in 83.33% in which the common femoral vein received, in addition to the large saphenous vein, other tributaries, the most frequent of which were the quadricipital veins and the circumflex femoral veins. Conclusion: The diameter of the femoral veins is important. The main tributaries of the common femoral vein are GVS, VQ and circumflex femoral veins. The femoral variations are numerous and important to know to avoid a possible misdiagnosis in case of their thrombosis. 展开更多
关键词 Femoral vein Common Femoral vein Deep Femoral vein Superficial Femoral vein Circumflex Lateral vein of the Thigh Circumflex vein Medial Thigh Quadriceps vein Large saphenous vein Anatomic Variation Deep Femoral Artery
下载PDF
Application of Endoscopic Vein Harvesting in Obese Patients Undergoing Coronary Artery Bypass Grafting 被引量:3
17
作者 Peng BAI Yi-xuan WANG +3 位作者 Si CHEN Jin-ping LIU Nian-guo DONG Jun-wei LIU 《Current Medical Science》 SCIE CAS 2018年第4期691-696,共6页
This study aims to evaluate the clinical outcomes of endoscopic vein harvesting (EVH) for coronary artery bypass grafting (CABG) in obese patients. Totally, 153 obese patients who underwent EVH (n=81) or standar... This study aims to evaluate the clinical outcomes of endoscopic vein harvesting (EVH) for coronary artery bypass grafting (CABG) in obese patients. Totally, 153 obese patients who underwent EVH (n=81) or standard bridging technique (SBT, n=72) in CABG surgery from May 2012 to October 2014 in our hospital were enrolled in this retrospective non-randomized controlled study. The general situation of operation, postoperative complications and short medium-term outcomes were analyzed. The baseline characteristics were similar between these two groups (P〉0.05). There were no statistical differences in total operation time (226±28 min vs. 224±30 min, P〉0.05), number of damaged vessels (0.12±0.05 vs. 0.16±0.06, P〉0.05) and short medium-term outcomes including revascularization rate (1.25% vs. 2.78%, P〉0.05), vessel dysfunction rate (11.25% vs. 11.11%, P〉0.05) and mortality (0.00% vs. 0.00%, P〉0.05). Use of EVH was associated with significant reduction of total harvesting time (41±6 min vs. 63±11 min, P〈0.05), incision length (4.4±1.1 cm vs. 18.2±4.5 cm, P〈0.05) and postoperative lower extremity complications (P〈0.05). EVH can reduce the risk of wound complications, whereas does not influence short- and medium-term outcomes in obese patients. It can be considered a reliable procedure of harvesting vessel conduits for obese patients undergoing CABG. 展开更多
关键词 minimally invasive endoscopy saphenous vein harvesting OBESITY coronary artery bypass grafting
下载PDF
Relevance of SYNTAX score for assessment of saphenous vein graft failure after coronary artery bypass grafting 被引量:2
18
作者 Li Jia-Hui Song Xian-Tao +2 位作者 Yang Xue-Yao Zhang Wen-Yi Xing Hao-Ran 《Chronic Diseases and Translational Medicine》 CSCD 2020年第1期55-61,共7页
Objective::To identify risk factors of saphenous vein graft (SVG) failure and to investigate the utility of anatomical SYNTAX score (SS) and SYNTAX score II (SS-II) in predicting SVG failure.Methods::A total of 598 pa... Objective::To identify risk factors of saphenous vein graft (SVG) failure and to investigate the utility of anatomical SYNTAX score (SS) and SYNTAX score II (SS-II) in predicting SVG failure.Methods::A total of 598 patients who underwent angiography for clinical reasons after coronary artery bypass grafting (CABG) were included. Baseline data and factors related to SVG failure were analyzed at the patient and graft levels. Patients were divided in tertiles by anatomical SS and in three groups by SS-II revascularization recommendation, and SVG patency was analyzed across these groups.Results::Patency rates were similar in all SS-stratified and SS-II recommendation groups within 1, 5, and 10 years after CABG. At the patient level, fasting blood glucose (FBG) level <7.0 mmol/L was less common in SVG failure (68.0% vs. 76.2%). At the graft level, patients with SVG failure tended to have angiography later (4.0 years vs. 3.0 years), poorer FBG control (FBG <7.0 mmol/L: 68.2% vs. 74.7%), and more grafts anastomosed to the right coronary system (59.2% vs. 47.4%). Longer time interval after CABG was related to SVG failure both at the patient and graft levels, and odds ratio ( OR)/ P values ( OR/ P) were 1.282/0.029 and 1.384/0.016, respectively. Using independent graft and grafting to the right artery system as risk factors at the graft level, OR/ Ps were 3.094/0.000 and 2.524/0.000, respectively. Conclusions::Longer time interval after CABG, independent grafts, and grafting to the right artery system are associated with SVG failure. Anatomical SS or SS-II may not be reasonable tools for predicting SVG failure. 展开更多
关键词 Coronary artery BYPASS GRAFTING GRAFT PATENCY saphenous vein GRAFT SYNTAX score Predictor
原文传递
Saphenous graft on transesophageal echocardiogram masquerading as an abnormal vascular communication into the right atrium
19
作者 Long Cao Mohammed Ataullah Farooqui +2 位作者 William Wood John Cahill Assad Movahed 《World Journal of Clinical Cases》 SCIE 2013年第1期28-30,共3页
An unknown aberrant f low in the right atrium observed on doppler with transesophageal echocardiogram(TEE) in a patient with prior coronary bypass. TEE revealed normal size left ventricle with severely dilated left at... An unknown aberrant f low in the right atrium observed on doppler with transesophageal echocardiogram(TEE) in a patient with prior coronary bypass. TEE revealed normal size left ventricle with severely dilated left atrium. There was moderate aortic regurgitation and moderate aortic stenosis noted. Patient was incidentally found to have an abnormal vascular communication noted to the right atrium. To further evaluate this f inding, the patient underwent cardiac magnetic resonance angiography which revealed that the tubular structure noted on TEE was actually a graft that was abutting onto the coronary sinus, and the f low anomaly was really the graft coming up and running adjacent to the coronary sinus. 展开更多
关键词 VASCULAR COMMUNICATION ECHOCARDIOGRAM saphenous vein GRAFT Magnetic resonance imaging
下载PDF
The effect of endoscopic vein harvesting in coronary artery bypass surgery:association between vein harvesting techniques and quality of conduits,wound complications,and cardiovascular events
20
作者 Jun Ran Yun Liu 《中国循环杂志》 CSCD 北大核心 2018年第S01期149-149,共1页
Objective The study aimed to compare quality of saphenous vein(SV)grafts,wound complications,and clinical outcomes between endoscopic vein harvesting(EVH)technique and open vein harvesting(OVH)technique of coronary ar... Objective The study aimed to compare quality of saphenous vein(SV)grafts,wound complications,and clinical outcomes between endoscopic vein harvesting(EVH)technique and open vein harvesting(OVH)technique of coronary artery bypass graft(CABG)surgery.Methods One hundred patients with multi-vessel coronary disease underwent elective CABG using SV grafts were prospectively recruited and randomized into two groups. 展开更多
关键词 CORONARY artery BYPASS surgery vein HARVESTING TECHNIQUES saphenous vein
下载PDF
上一页 1 2 64 下一页 到第
使用帮助 返回顶部