BACKGROUND: Latest researches at home and abroad indicate that glycerol trinitrate plays its function because it can metabolize into nitrogen monoxide (NO) in vivo. OBJECTIVE: To study the therapeutic effects of N...BACKGROUND: Latest researches at home and abroad indicate that glycerol trinitrate plays its function because it can metabolize into nitrogen monoxide (NO) in vivo. OBJECTIVE: To study the therapeutic effects of NO vector of ultrasonic atomizing inhalation on vertebro-basilar artery insufficiency (VBI) through transcranial Doppler (TCD) detection and serum NO content and indirect effect of TCD on cerebral blood flow changes. DESIGN: Randomized grouping and controlled clinical study. SETTING: Department of Neurology, the Fourth People's Hospital of Jinan. PARTICIPANTS: A total of 130 patients who were diagnosed as VBI were selected from Department of Neurology, the Fourth People's Hospital of Jinan from December 2001 to December 2005. The involved inpatients were checked by CT and MRI, and met the VBI diagnostic standard enacted by the Fourth National Academic Meeting of Cerebrovascular Disease in 1995. All patients and their relatives provided the confumed consent. They were randomly divided into low-dose treatment group (n =60), high-lose treatment group (n =30) and control group (n =40). METHODS: Patients in the low-dose and high-dose treatment groups were given ultrasonic atomizing inhalation of 3 mg and 5 mg glycerol trinitrate, respectively, for 20 minutes, once a day. In addition, ligustrazine and energy mixture were used once a day for three days in a course. Cases in the control group were only given ligustrazine and energy mixture. All selected cases accepted TCD, blood NO content was checked at the time of beginning, after the first time and after a period of treatment. According to the TCD test, VBI patients were divided into two groups (high-low flow velocity). The vertebral artery (VA) and basal artery (BA) of left or right sides were detected by 2 Hz detector via occipital window. MAIN OUTCOME MEASURES: ①Blood flow velocity of systolic phase, blood flow velocity of diastole phase and vascular resistance in left and right VA and BA detected by using TCD before treatment, after treatment for one course; ②content of serum NO indirectly measured by using nitric acid disoxidation technique. RESULTS: All 130 VBI patients were involved in the final analysis. ①Changes of hemodynamic indexes: Systolic phase of VA and diastole phase of BA were higher in low-dose treatment group than that in the control group after first treatment, and there was significant difference (P 〈 0.05); meanwhile, systolic phase and diastole phase of VA and systolic phase of BA were also higher in treatment group than that in the control group after one course (P 〈 0.05). However, both systolic phase and diastole phase of VA and BA were lower in high-dose treatment group than that in the control group after first treatment and one course, and there was significant difference (P 〈 0.05). ②Content of serum NO: After first treatment, there was no significant difference between low-dose treatment group and high-dose treatment group (P 〉 0.05); but both groups were higher than control group, and there was significant difference (P 〈 0.05, 0.01). CONCLUSION: NO vector of ultrasonic atomizing inhalation can improve VBI so as to improve cerebral blood-supply state.展开更多
BACKGROUND Low-molecular-weight dextran(LMWD)is considered a safe alternative to contrast media for blood displacement during optical coherence tomography(OCT)imaging.AIM To investigate whether the use of LMWD for OCT...BACKGROUND Low-molecular-weight dextran(LMWD)is considered a safe alternative to contrast media for blood displacement during optical coherence tomography(OCT)imaging.AIM To investigate whether the use of LMWD for OCT is protective against kidney injury in patients with advanced renal insufficiency.METHODS In this retrospective cohort study,we identified 421 patients with advanced renal insufficiency(estimated glomerular filtration rate<45 mL/min/1.73 m2)who underwent coronary angiography or percutaneous coronary intervention;79 patients who used additional LMWD for OCT imaging(LMWD group)and 342 patients who used contrast medium exclusively(control group).We evaluated the differences between these two groups and performed a propensity score-matched subgroup comparison.RESULTS The median total volume of contrast medium was 133.0 mL in the control group vs 140.0 mL in the LMWD group.Although baseline renal function was not statistically different between these two groups,the LMWD group demonstrated a strong trend toward the progression of renal insufficiency as indicated by the greater change in serum creatinine level during the 1-year follow-up compared with the control group.Patients in the LMWD group experienced worsening renal function more frequently than patients in the control group.Propensity score matching adjusted for total contrast media volume consistently indicated a trend toward worsening renal function in the LMWD group at the 1-year follow-up.Delta serum creatinine at 1-year follow-up was significantly greater in the LMWD group than that in the control group[0.06(-0.06,0.29)vs-0.04(-0.23,0.08)mg/dL,P=0.001],despite using similar contrast volume.CONCLUSION OCT using LMWD may not be protective against worsening renal function in patients with advanced renal insufficiency.展开更多
BACKGROUND In bow hunter’s syndrome(BHS),also known as rotational vertebral artery(VA)syndrome,there is dynamic/rotational compression of the VA producing verte-brobasilar insufficiency.Most occurrences involve atlan...BACKGROUND In bow hunter’s syndrome(BHS),also known as rotational vertebral artery(VA)syndrome,there is dynamic/rotational compression of the VA producing verte-brobasilar insufficiency.Most occurrences involve atlantoaxial rather than mid-cervical VA compromise,the latter being rarely reported.Herein,we detail successful VA decompression at mid-cervical spine,given a departure from its usual course.CASE SUMMARY The patient,a 45-year-old man,presented to our hospital with occipital headache and vertigo.Computed tomography angiography showed anomalous C4 entry of right VA,with compression upon head rotation to that side.Thyroid cartilage and anterior tubercle of C5 transverse process were visibly at fault.We opted for sur-gery,using an anterior cervical approach to remove the anterior tubercle.Patient recovery was uneventful and brought resolution of all preoperative symptoms.CONCLUSION BHS is an important consideration where aberrant coursing of VA and neurologic symptoms coexist.展开更多
文摘BACKGROUND: Latest researches at home and abroad indicate that glycerol trinitrate plays its function because it can metabolize into nitrogen monoxide (NO) in vivo. OBJECTIVE: To study the therapeutic effects of NO vector of ultrasonic atomizing inhalation on vertebro-basilar artery insufficiency (VBI) through transcranial Doppler (TCD) detection and serum NO content and indirect effect of TCD on cerebral blood flow changes. DESIGN: Randomized grouping and controlled clinical study. SETTING: Department of Neurology, the Fourth People's Hospital of Jinan. PARTICIPANTS: A total of 130 patients who were diagnosed as VBI were selected from Department of Neurology, the Fourth People's Hospital of Jinan from December 2001 to December 2005. The involved inpatients were checked by CT and MRI, and met the VBI diagnostic standard enacted by the Fourth National Academic Meeting of Cerebrovascular Disease in 1995. All patients and their relatives provided the confumed consent. They were randomly divided into low-dose treatment group (n =60), high-lose treatment group (n =30) and control group (n =40). METHODS: Patients in the low-dose and high-dose treatment groups were given ultrasonic atomizing inhalation of 3 mg and 5 mg glycerol trinitrate, respectively, for 20 minutes, once a day. In addition, ligustrazine and energy mixture were used once a day for three days in a course. Cases in the control group were only given ligustrazine and energy mixture. All selected cases accepted TCD, blood NO content was checked at the time of beginning, after the first time and after a period of treatment. According to the TCD test, VBI patients were divided into two groups (high-low flow velocity). The vertebral artery (VA) and basal artery (BA) of left or right sides were detected by 2 Hz detector via occipital window. MAIN OUTCOME MEASURES: ①Blood flow velocity of systolic phase, blood flow velocity of diastole phase and vascular resistance in left and right VA and BA detected by using TCD before treatment, after treatment for one course; ②content of serum NO indirectly measured by using nitric acid disoxidation technique. RESULTS: All 130 VBI patients were involved in the final analysis. ①Changes of hemodynamic indexes: Systolic phase of VA and diastole phase of BA were higher in low-dose treatment group than that in the control group after first treatment, and there was significant difference (P 〈 0.05); meanwhile, systolic phase and diastole phase of VA and systolic phase of BA were also higher in treatment group than that in the control group after one course (P 〈 0.05). However, both systolic phase and diastole phase of VA and BA were lower in high-dose treatment group than that in the control group after first treatment and one course, and there was significant difference (P 〈 0.05). ②Content of serum NO: After first treatment, there was no significant difference between low-dose treatment group and high-dose treatment group (P 〉 0.05); but both groups were higher than control group, and there was significant difference (P 〈 0.05, 0.01). CONCLUSION: NO vector of ultrasonic atomizing inhalation can improve VBI so as to improve cerebral blood-supply state.
文摘BACKGROUND Low-molecular-weight dextran(LMWD)is considered a safe alternative to contrast media for blood displacement during optical coherence tomography(OCT)imaging.AIM To investigate whether the use of LMWD for OCT is protective against kidney injury in patients with advanced renal insufficiency.METHODS In this retrospective cohort study,we identified 421 patients with advanced renal insufficiency(estimated glomerular filtration rate<45 mL/min/1.73 m2)who underwent coronary angiography or percutaneous coronary intervention;79 patients who used additional LMWD for OCT imaging(LMWD group)and 342 patients who used contrast medium exclusively(control group).We evaluated the differences between these two groups and performed a propensity score-matched subgroup comparison.RESULTS The median total volume of contrast medium was 133.0 mL in the control group vs 140.0 mL in the LMWD group.Although baseline renal function was not statistically different between these two groups,the LMWD group demonstrated a strong trend toward the progression of renal insufficiency as indicated by the greater change in serum creatinine level during the 1-year follow-up compared with the control group.Patients in the LMWD group experienced worsening renal function more frequently than patients in the control group.Propensity score matching adjusted for total contrast media volume consistently indicated a trend toward worsening renal function in the LMWD group at the 1-year follow-up.Delta serum creatinine at 1-year follow-up was significantly greater in the LMWD group than that in the control group[0.06(-0.06,0.29)vs-0.04(-0.23,0.08)mg/dL,P=0.001],despite using similar contrast volume.CONCLUSION OCT using LMWD may not be protective against worsening renal function in patients with advanced renal insufficiency.
文摘BACKGROUND In bow hunter’s syndrome(BHS),also known as rotational vertebral artery(VA)syndrome,there is dynamic/rotational compression of the VA producing verte-brobasilar insufficiency.Most occurrences involve atlantoaxial rather than mid-cervical VA compromise,the latter being rarely reported.Herein,we detail successful VA decompression at mid-cervical spine,given a departure from its usual course.CASE SUMMARY The patient,a 45-year-old man,presented to our hospital with occipital headache and vertigo.Computed tomography angiography showed anomalous C4 entry of right VA,with compression upon head rotation to that side.Thyroid cartilage and anterior tubercle of C5 transverse process were visibly at fault.We opted for sur-gery,using an anterior cervical approach to remove the anterior tubercle.Patient recovery was uneventful and brought resolution of all preoperative symptoms.CONCLUSION BHS is an important consideration where aberrant coursing of VA and neurologic symptoms coexist.