Background:Recent developments in virtual acoustic technology has levered promising applications in the field of auditory sciences,especially in spatial perception.While conventional auditory spatial assessment using ...Background:Recent developments in virtual acoustic technology has levered promising applications in the field of auditory sciences,especially in spatial perception.While conventional auditory spatial assessment using loudspeakers,interaural differences and/or questionnaires are limited by the availability and cost of instruments,the use of virtual acoustic space identification(VASI)test has widespread applications in spatial test battery as it overcomes these constraints.Purpose:The lack of test-retest reliability data of VASI test narrows its direct application in auditory spatial assessment,which is explored in the present study.Methods:Data from 75 normal-hearing young adults(mean age:25.11 y±4.65 SD)was collected in three sessions:baseline,within 15 min of baseline(intra-session),and one week after baseline session(inter-session).Test-retest reliability was assessed using the intra-class correlation coefficient(ICC),coefficient of variation(CV),and cluster plots.Results:The results showed excellent reliability for both accuracy and reaction time measures of VASI,with ICC values of 0.93 and 0.87,respectively.The CV values for overall VASI accuracy and reaction time 9.66% and 11.88%,respectively.This was also complemented by the cluster plot analyses,which showed 93.33% and 96.00% of temporal stability in the accuracy and reaction time measures,indicative of high test-retest reliability of VASI test in auditory spatial assessment.Conclusions:The high temporal stability(test-retest reliability)of VASI test validates its application in spatial hearing test battery.展开更多
Objective To evaluate the clinical applications and limitations of CT virtual endoscopy (CTVE) in theauditory ossicular chain.Methods CTVE of the auditory ossicular chain was performed with 1.0 mm collimation at pitc...Objective To evaluate the clinical applications and limitations of CT virtual endoscopy (CTVE) in theauditory ossicular chain.Methods CTVE of the auditory ossicular chain was performed with 1.0 mm collimation at pitch 1.0, bone algorithm, 9.6 cm field of view, and 0.1 - 0.2 mm reconstruction interval in 40 patients with middle ear diseases. 30 cases were confirmed by surgery. Results were compared with the findings of axial high resolution CT (HRCT) and multiplanar reformation (MPR) images and surgery.Results The accuracy of CTVE images in detecting ossicular destruction was 92.6%, significantly higher than that of axial HRCT (83.9%) and multiplanar reformation (76.5%) images. CTVE could also clearty reveal the postoperative condition and congenital dysplasia of the auditory ossicular chain.Conclusions CTVE can clearly demonstrate a three-dimensional image of the auditory ossicular chain and is useful in evaluating diseases of the ear, especially the auditory ossicles. CTVE could not clearly demonstrate abnormal soft tissue within the tympanic cavity, abnormal changes of the tympanic membrane and tympanic walls, and could be easily influenced by artificial factors.展开更多
文摘Background:Recent developments in virtual acoustic technology has levered promising applications in the field of auditory sciences,especially in spatial perception.While conventional auditory spatial assessment using loudspeakers,interaural differences and/or questionnaires are limited by the availability and cost of instruments,the use of virtual acoustic space identification(VASI)test has widespread applications in spatial test battery as it overcomes these constraints.Purpose:The lack of test-retest reliability data of VASI test narrows its direct application in auditory spatial assessment,which is explored in the present study.Methods:Data from 75 normal-hearing young adults(mean age:25.11 y±4.65 SD)was collected in three sessions:baseline,within 15 min of baseline(intra-session),and one week after baseline session(inter-session).Test-retest reliability was assessed using the intra-class correlation coefficient(ICC),coefficient of variation(CV),and cluster plots.Results:The results showed excellent reliability for both accuracy and reaction time measures of VASI,with ICC values of 0.93 and 0.87,respectively.The CV values for overall VASI accuracy and reaction time 9.66% and 11.88%,respectively.This was also complemented by the cluster plot analyses,which showed 93.33% and 96.00% of temporal stability in the accuracy and reaction time measures,indicative of high test-retest reliability of VASI test in auditory spatial assessment.Conclusions:The high temporal stability(test-retest reliability)of VASI test validates its application in spatial hearing test battery.
文摘Objective To evaluate the clinical applications and limitations of CT virtual endoscopy (CTVE) in theauditory ossicular chain.Methods CTVE of the auditory ossicular chain was performed with 1.0 mm collimation at pitch 1.0, bone algorithm, 9.6 cm field of view, and 0.1 - 0.2 mm reconstruction interval in 40 patients with middle ear diseases. 30 cases were confirmed by surgery. Results were compared with the findings of axial high resolution CT (HRCT) and multiplanar reformation (MPR) images and surgery.Results The accuracy of CTVE images in detecting ossicular destruction was 92.6%, significantly higher than that of axial HRCT (83.9%) and multiplanar reformation (76.5%) images. CTVE could also clearty reveal the postoperative condition and congenital dysplasia of the auditory ossicular chain.Conclusions CTVE can clearly demonstrate a three-dimensional image of the auditory ossicular chain and is useful in evaluating diseases of the ear, especially the auditory ossicles. CTVE could not clearly demonstrate abnormal soft tissue within the tympanic cavity, abnormal changes of the tympanic membrane and tympanic walls, and could be easily influenced by artificial factors.