期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Effect of infusion pressure during cataract surgery on ganglion cells measured using isolated-check visual evoked potential 被引量:1
1
作者 Tong Ding Dan-Na Shi +3 位作者 Xiang Fan Mi-Yun Zheng Wei Wang Wei-Qiang Qiu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第1期58-65,共8页
AIM: To detect the relationship between infusion pressure and postoperative ganglion cells function.METHODS: This prospective observational cohort study included sixty-one eyes that underwent uncomplicated cataract ... AIM: To detect the relationship between infusion pressure and postoperative ganglion cells function.METHODS: This prospective observational cohort study included sixty-one eyes that underwent uncomplicated cataract surgery. Patients were divided into two groups according to infusion time(IT) recorded using surgery equipment [Group A: IT〉IT_(mean)(27 eyes); Group B: IT 展开更多
关键词 isolated-check visual evoked potential optical coherence tomography ganglion cell inner plexiform layer cataract extraction
下载PDF
Visual Passive Ranging Method Based on Re-entrant Coaxial Optical Path and Experimental Verification
2
作者 杨金宝 刘建国 +1 位作者 祝宁华 于丽娟 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第12期32-36,共5页
To overcome the shortcomings of the traditional passive ranging technology based on image, such as poor ranging accuracy, low reliability and complex system, a new visual passive ranging method based on re-entrant coa... To overcome the shortcomings of the traditional passive ranging technology based on image, such as poor ranging accuracy, low reliability and complex system, a new visual passive ranging method based on re-entrant coaxial optical path is presented. The target image is obtained using double cameras with coaxial optical path. Since there is imaging optical path difference between the cameras, the images are different. In comparison of the image differences, the target range could be reversed. The principle of the ranging method and the ranging model are described. The relationship among parameters in the ranging process is analyzed quantitatively. Meanwhile,the system composition and technical realization scheme are also presented. Also, the principle of the method is verified by the equivalent experiment. The experimental results show that the design scheme is correct and feasible with good robustness. Generally, the ranging error is less than 10% with good convergence. The optical path is designed in a re-entrant mode to reduce the volume and weight of the system. Through the coaxial design,the visual passive range of the targets with any posture can be obtained in real time. The system can be widely used in electro-optical countermeasure and concealed photoelectric detection. 展开更多
关键词 visual Passive Ranging Method Based on Re-entrant Coaxial Optical Path and Experimental Verification
下载PDF
Real-life experience of ranibizumab therapy for neovascular age-related macular degeneration from Turkey 被引量:1
3
作者 Zafer Cebeci Yusuf Cem Yilmaz Nur Kir 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第2期267-273,共7页
AIM: To report the real-life experience and clinical results of intravitreal ranibizumab injections to neovascular agerelated macular degeneration(nAMD) in a single institution in Turkey.METHODS: A total of 101 ey... AIM: To report the real-life experience and clinical results of intravitreal ranibizumab injections to neovascular agerelated macular degeneration(nAMD) in a single institution in Turkey.METHODS: A total of 101 eyes of 89 patients with nAMD treated with intravitreal ranibizumab injection, followed up for at least 24 mo between 2009 and June 2014, which were evaluated retrospectively. A pro re nata(PRN) treatment protocol was performed after the patients had received three, monthly loading injections. Best corrected visual acuity(BCVA) and central macular thickness measurements were evaluated at baseline and 3, 6, 12, 18, and 24 mo. Number of injections and visits were also recorded.RESULTS: Of the 89 patients, 34(38.2%) were male and 55(61.8%) were female and the mean age was 74.0±9.5(52-91)y. The mean follow-up period was 24.82±4.4(24-29)mo. Mean number of visits was 8.4±1.12(7-12) in the first year and 6.6±1.33(4-12) in the second year. The mean number of injections was 5.8±1.6(3-10) and 4.2±2.2(0-9) in the first and second year, respectively. The mean BCVA was 59±15.8 letters at baseline by the Early Treatment Diabetic Retinopathy Study(ETDRS) chart. The mean BCVA at 3, 12, and 24 mo was 70.3±15.9, 67.9±14.3 and 67.3±16.9 letters, respectively. Improvement in visual acuity for each of the visits from baseline was found to be statistically significant(P〈0.01). Visual acuity in 9 eyes at month 3, 7 eyes at month 12, and 13 eyes at month 24 did not change. The mean central macular thickness(CMT) was 437.99±164.78 μm at baseline. The mean CMT was 348.05±138.47 μm, 349.27±139.79 μm, and 344.13±146.30 μm at months 3, 12, and 24, respectively. The decrease in CMT for each of the visits from baseline was found to be statistically significant(P〈0.01).CONCLUSION: Anatomical and functional achievement are obtained in our study, but the mean number of injections and visits are found to be lower than the findings reported in randomized controlled clinical trials in the literature. However, the mean number of injections and visits in our study are compatible with the findings reported in real-life experience studies in the literature. 展开更多
关键词 age-related macular degeneration antivascular endothelial growth factor visual acuity ranibizumab retina optical coherence tomography
下载PDF
Mechanism of delayed conduction of fellow eyes in patients with optic neuritis
4
作者 Daniah Alshowaeir Con Yiannikas +1 位作者 Clare Fraser Alexander Klistorner 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第2期329-332,共4页
To test the hypothesis that latency delay in the fellow eyes of optic neuritis(ON) patients and to compensate for delayed transmission of visual information, latency change of multi-focal visual evoked potential(mf... To test the hypothesis that latency delay in the fellow eyes of optic neuritis(ON) patients and to compensate for delayed transmission of visual information, latency change of multi-focal visual evoked potential(mf VEP) traces in fellow eyes of 15 ON patients were analyzed. Patients with low risk(LR) for developing multiple sclerosis(MS) were examined separately from MS patients to isolate effect of cortical plasticity from potential pathological changes in disseminated disease. The small increase in latency in fellow eyes of LR group was statistically not significant. In MS patients, the latency was significantly delayed(P〈0.02). The magnitude of the latency change in the fellow eyes did not correlate with the severity of latency delay in the affected eyes(R^2〈0.02, P=0.3). The differences between ON patients with and without MS, reported here, suggest that the presence of disseminated disease plays critical role in latency delay of the fellow eye. 展开更多
关键词 multi-focal visual evoked potential optic neuritis fellow eyes latency delay
下载PDF
Objective visual performance evaluation with visual evoked potential measurements based on an adaptive optics system
5
作者 杨彦荣 赵军磊 +4 位作者 赵豪欣 肖飞 谢佳欣 刘铁军 戴云 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第5期82-86,共5页
An objective visual performance evaluation with visual evoked potential (VEP) measurements was first inte- grated into an adaptive optics (AO) system. The optical and neural limits to vision can be bypassed throug... An objective visual performance evaluation with visual evoked potential (VEP) measurements was first inte- grated into an adaptive optics (AO) system. The optical and neural limits to vision can be bypassed through this system. Visual performance can be measured electrophysiologically with VEP, which reflects the objective func- tion from the retina to the primary visual cortex. The VEP ts without and with AO correction were preliminarily carried out using this system, demonstrating the great potential of this system in the objective visual performance evaluation. The new system will provide the necessary technique and equipment support for the further study of human visual function. 展开更多
关键词 VEP AO Objective visual performance evaluation with visual evoked potential measurements based on an adaptive optics system PSF
原文传递
Optical visualization and polarized light absorption of the single-wall carbon nanotube to verify intrinsic thermal applications 被引量:2
6
作者 Xiao Zhang Li Song +12 位作者 Le Cai Xuezeng Tian Qiang Zhang Xiaoying Qi Wenbin Zhou Nan Zhang Feng Yang Qingxia Fan Yanchun Wang Huaping Liu Xuedong Bai Weiya Zhou Sishen Xie 《Light(Science & Applications)》 SCIE EI CAS CSCD 2015年第1期251-258,共8页
The predicted extraordinary properties of carbon nanotubes(CNTs)from theoretical calculations have great potential for many applications.However,reliable experimental determination of intrinsic properties at the singl... The predicted extraordinary properties of carbon nanotubes(CNTs)from theoretical calculations have great potential for many applications.However,reliable experimental determination of intrinsic properties at the single-tube level is currently a matter of concern,and many challenges remain because of the unhandled and nanoscale size of individual nanotubes.Here,we demonstrated a prototype to detect the intrinsic thermal conductivity of the single-wall carbon nanotube(SWCNT)and verify the significant non-resonant optical absorption behavior on tiny nanotubes by integrating the nanotube and ice into a new core-shell design.In particular,a reversible optical visualization method based on the individual suspended ultra-long SWCNT was first developed by wrapping a nanotube with ice in the cryogenic air environment.The light-induced thermal effect on the hybrid core-shell structure was used tomelt the ice shell,which subsequently acted as a temperature sensor to verify the intrinsic thermal conductivity of the core-like nanotube.More interestingly,we successfully determined for the first time the thermal response phenomenon of the tiny absorption cross section in SWCNT in the vertical-polarization configuration and the significant non-resonant absorption behavior in the parallel-polarization configuration.These investigations will provide a better understanding for the unique optical behaviors of CNT and enable the detection of intrinsic properties of various one-dimensional nanostructures such as nanotubes,nanowires,and nanoribbons. 展开更多
关键词 carbon nanotube optical visualization polarized laser resonant absorption
原文传递
In-Vitro and In-Vivo Electrical Characteristics of a Penetrating Microelectrode Array for Optic Nerve Electrical Stimulation
7
作者 隋晓红 邵轶彬 +2 位作者 李丽明 柴新禹 任秋实 《Journal of Shanghai Jiaotong university(Science)》 EI 2011年第5期614-619,共6页
The Chinese C-Sight team aims to restore vision to blind patients by means of stimulating the optic nerve with a penetrating microelectrode array. A biocompatible, implantable microwire array was developed having four... The Chinese C-Sight team aims to restore vision to blind patients by means of stimulating the optic nerve with a penetrating microelectrode array. A biocompatible, implantable microwire array was developed having four platinum-iridium shafts, each 100μm in diameter. This penetrating microwire array is described in this paper, including its fabrication techniques and its in-vitro electrical characteristics. Every set of four shafts was spaced 0.4mm from center to center, comprising two short shafts that were 0.3mm long and two that were 0.9mm long. This design was intended to stimulate ganglion cell axons at different depths within the optic nerve. In-vitro electrochemical impedance testing results showed that the impedance at 1kHz ranged from 8 to 10kΩ at room temperature. The voltage responses of the arrays to current pulse stimulation indicated a charge-injection capacity of 210μC/cm2. Finally, in-vivo acute animal experiments showed that the amplitude of the electrically evoked potentials (EEPs) measured in primary visual cortex could be as large as 100 μV upon direct stimulation of the optic nerve. 展开更多
关键词 optic nerve visual prosthesis platinum-iridium (Pt/Ir) microelectrode charge injection capacity impedance
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部