期刊文献+
共找到56,700篇文章
< 1 2 250 >
每页显示 20 50 100
Surgical Management of Lumbar Spinal Canal Stenosis with Instrumentation at the Yaounde Central Hospital: Comparison of Unilateral versus Bilateral Pedicle Screw Fixation Combined with Transforaminal Lumbar Interbody Fusion
1
作者 Orlane Toto Ndome Nassourou Oumarou Haman +4 位作者 Dimitri Fogue Jean Bruno Ndoumou Ronaldo Fonju Anu Indira Baboke Vincent De Paul Djientcheu 《Open Journal of Modern Neurosurgery》 2024年第3期179-189,共11页
Introduction: The choice of adopting unilateral pedicle screw fixation or using bilateral pedicle screw fixation in lumbar spinal stenosis remains controversial. In our context, very few studies have been performed co... Introduction: The choice of adopting unilateral pedicle screw fixation or using bilateral pedicle screw fixation in lumbar spinal stenosis remains controversial. In our context, very few studies have been performed comparing the clinical effectiveness of unilateral versus bilateral fixation in the surgical management of lumbar spinal canal stenosis. Objective: Evaluate the impact on quality of life and clinical efficacy of unilateral spondylodesis compared to bilateral spondylodesis in the surgical management of lumbar spinal canal stenosis at the Yaounde Central Hospital. Methods: This was a retrospective descriptive cross-sectional study for a period of 4 years, from June 2015 to June 2019. It involved all patients operated for lumbar canal stenosis and who underwent spondylodesis or spinal fusion at the neurosurgery department of the Yaounde Central Hospital. Results: A total of 68 participants were recruited during our study period. 32 (47%) of the study population were in the 50 - 60 age group, with a mean age of 56.98 years ranging from 41 to 75 years. Females, housewives and farmers were the most affected. In our study, 72% of patients had unilateral spondylodesis and 28% had bilateral fusion. Preoperatively, 71% of patients had insurmountable pain, refractory to medical treatment. At 3 months postoperatively, 73.7% of patients with bilateral setup had moderate pain compared to 69% of those with unilateral setup. At 6 months postoperatively, 79% of patients with bilateral fusion had mild pain compared to 82% of patients with unilateral setup. At 1 year postoperatively, all patients had mild pain. Preoperatively, 66.2% of patients were unable to walk and 19.1% of patients were bedridden according to the Oswestry score. At 3 months postoperatively, 10.2% of patients with unilateral setup were unable to walk compared to 10.5% of patients with bilateral fixation, while 67.3% of patients with unilateral fixation had moderate disability compared to 52.6% of patients with bilateral fixation. At 6 months postoperatively, 51% of patients with unilateral setup had moderate disability compared to 47.4% of patients with bilateral fixation, while 42.9% of patients with unilateral fixation had mild disability compared to 42.1% of patients with bilateral fixation. At 1 year postoperatively, 81.6% of patients who underwent unilateral fixation had only mild disability compared to 73.7% of patients with bilateral fixation. Conclusion: The assessment of quality of life according to the set-up used shows similar results at 3 months, 6 months and 1 year, with no statistically significant differences. Single-sided pedicle screw fixation combined with transforaminal lumbar interbody fusion or mounting has the advantage of being faster, with less bleeding and is less expensive compared to bilateral fixation. 展开更多
关键词 Lumbar Spinal Canal STENOSIS instrumentation Surgery Quality of Life
下载PDF
Cost-effectiveness of patient specific vs conventional instrumentation for total knee arthroplasty:A systematic review and meta-analysis 被引量:2
2
作者 Isobel M Dorling Lars Geenen +3 位作者 Marion J L F Heymans Jasper Most Bert Boonen Martijn G M Schotanus 《World Journal of Orthopedics》 2023年第6期458-470,共13页
BACKGROUND Over the past years,patient specific instrumentation(PSI)for total knee arthroplasty(TKA)has been implemented and routinely used.No clear answer has been given on its associated cost and cost-effectiveness ... BACKGROUND Over the past years,patient specific instrumentation(PSI)for total knee arthroplasty(TKA)has been implemented and routinely used.No clear answer has been given on its associated cost and cost-effectiveness when compared to conventional instrumentation(CI)for TKA.AIM To compare the cost and cost-effectiveness of PSI TKA compared to CI TKA.METHODS A literature search was performed in healthcare,economical healthcare,and medical databases(MEDLINE,EMBASE,CINAHL,Web of Science,Cochrane Library,EconLit).It was conducted in April 2021 and again in January 2022.Relevant literature included randomised controlled trials,retrospective studies,prospective studies,observational studies,and case control studies.All studies were assessed on methodological quality.Relevant outcomes included incremental cost-effectiveness ratio,quality-adjusted life years,total costs,imaging costs,production costs,sterilization associated costs,surgery duration costs and readmission rate costs.All eligible studies were assessed for risk of bias.Meta-analysis was performed for outcomes with sufficient data.RESULTS Thirty-two studies were included into the systematic review.Two were included in the metaanalysis.3994 PSI TKAs and 13267 CI TKAs were included in the sample size.The methodological quality of the included studies,based on Consensus on Health Economic Criteria-scores and risk of bias,ranged from average to good.PSI TKA costs less than CI TKA when considering mean operating room time and its associated costs and tray sterilization per patient case.PSI TKA costs more compared to CI TKA when considering imaging and production costs.Considering total costs per patient case,PSI TKA is more expensive in comparison to CI TKA.Meta-analysis comparing total costs for PSI TKA,and CI TKA showed a significant higher cost for PSI TKA.CONCLUSION Cost for PSI and CI TKA can differ when considering distinct aspects of their implementation.Total costs per patient case are increased for PSI TKA when compared to CI TKA. 展开更多
关键词 Total knee arthroplasty Patient specific instrumentation instrumentation for total knee arthroplasty COST-EFFECTIVENESS Systematic review
下载PDF
The CCD instrument background of the SMILE SXI 被引量:2
3
作者 M.W.J.Hubbard O.Hetherington +6 位作者 D.J.Hall T.W.Buggey S.Parsons T.Arnold A.Holland C.Pagani S.Sembay 《Earth and Planetary Physics》 EI CSCD 2024年第1期15-24,共10页
The ESA and CAS SMILE mission orbit is highly elliptical and will pass through multiple radiation environments.The Soft X-ray Imager(SXI)instrument aboard has a radiation shutter door designed to close when the surrou... The ESA and CAS SMILE mission orbit is highly elliptical and will pass through multiple radiation environments.The Soft X-ray Imager(SXI)instrument aboard has a radiation shutter door designed to close when the surrounding radiation flux is high.The shutter door will close when passing below an altitude threshold to protect against trapped particles in the Earth’s Van Allen Belts.Therefore,two radiation environments can be approximated based on the shutter door position:open and closed.The instrument background for the CCDs(Charge-Coupled Devices)that form the focal plane array of the SXI were evaluated for the two environments.Due to the correlation of the space environment with the solar cycle,the solar minima and maxima,the background was also evaluated at these two extremes.The results demonstrated that the highest instrument background will occur during solar minima due to the main contributing source being Galactic Cosmic Rays(GCRs).It was also found that the open background was highest for solar minima and that the closed background was highest during solar maxima.This is due to the radiation shutter door acting as a scattering centre and the changes in the energy flux distribution of the GCRs between the two solar extremes. 展开更多
关键词 instrument background X-ray astronomy space radiation
下载PDF
Glaucoma surgery experiments using digital microscope-integrated optical coherence tomography and OCT-compatible instruments 被引量:1
4
作者 Tianliang Jiang Jinyu Fan +2 位作者 Ning Tang Yi He Guohua Shi 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第5期105-113,共9页
There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)... There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)system and several custom-made OCT-compatible instruments for glaucoma surgery.Sixteen ophthalmologists were asked to perform trabeculectomy and canaloplasty on live porcine eyes using the system and instruments.After surgery,a subjective feedback survey about the user experience was taken.The experiment results showed that our system can help surgeons easily locate important tissue structures during surgery.The custom-made instruments also solved the shadowing problem in OCT imaging.Surgeons preferred to use the system in their future practice. 展开更多
关键词 Microscope-integrated optical coherence tomography OCT-compatible instruments glaucoma surgery TRABECULECTOMY CANALOPLASTY
下载PDF
Journal of Measurement Science and Instrumentation
5
《Journal of Measurement Science and Instrumentation》 CAS CSCD 2023年第1期F0003-F0003,共1页
Journal of Measurement Science and Iustrumentation(CN14-1357/TH,ISSN 1674-8042)is published by North University of China.It is a comprehensive academic journal,aiming to present scientifie research papers in the field... Journal of Measurement Science and Iustrumentation(CN14-1357/TH,ISSN 1674-8042)is published by North University of China.It is a comprehensive academic journal,aiming to present scientifie research papers in the fields of measurement science and instrumentation,ineluding general and instrumentation of measurement and control applied to such academie and industrial fields asprineiples. 展开更多
关键词 JOURNAL ISSN instrumentation
下载PDF
AVEVA Instrumentation Engineer在仪表系统设计中的应用研究
6
作者 齐桂卿 李海寿 +1 位作者 刘鸿雁 李健 《化工设计》 CAS 2023年第4期44-47,2,共5页
本文分析AVEVA Instrumentation软件功能模块Engineer在仪表系统设计中的应用。重点探讨借助AVEVA Instrumentation软件实现跨专业、跨软件的数据交互开发及仪表专业清单文件、数据表的模板定制。
关键词 AVEVA instrumentation ENGINEER 数据交互 属性库 仪表索引表 仪表数据表
下载PDF
Metallosis with spinal implant loosening after spinal instrumentation:A case report
7
作者 Yiu Hin Kwan Hong Lee Terry Teo +1 位作者 Shree Kumar Dinesh Wee Lim Loo 《World Journal of Orthopedics》 2023年第8期651-661,共11页
BACKGROUND Spinal metallosis is a rare complication following spinal instrumentation whereby an inflammatory response to the metal implants results in the development of granulomatous tissue.CASE SUMMARY We describe t... BACKGROUND Spinal metallosis is a rare complication following spinal instrumentation whereby an inflammatory response to the metal implants results in the development of granulomatous tissue.CASE SUMMARY We describe the case of a 78-year-old woman who had recurrence of back pain 5 years after lumbar spine posterior decompression and instrumented fusion.Lumbar spine radiographs showed hardware loosening and magnetic resonance imaging showed adjacent segment disease.Revision surgery revealed evidence of metallosis intraoperatively.CONCLUSION Spinal metallosis can present several years after instrumentation.Radiography and computed tomography may demonstrate hardware loosening secondary to metallosis.Blood metal concentrations associated with spinal metallosis have yet to be established.Hence,metallosis is still an intraoperative and histopathological diagnosis.The presence of metallosis after spinal instrumentation likely indicates a more complex underlying problem:Pseudarthrosis,failure to address sagittal balance,infection,and cross-threading of set screws.Hence,identifying metallosis is important,but initiating treatment promptly for symptomatic implant loosening is of greater paramount. 展开更多
关键词 METALLOSIS SPINE instrumentation Implant loosening CORROSION Case report
下载PDF
Effectiveness and safety of early lens extraction during par plana vitrectomy for proliferative diabetes retinopathy with mild cataract:a randomized clinical trial
8
作者 Wei-Bo Feng Lei Zheng +17 位作者 Ying-Qi Li Yong-Hao Li Guo-Ming Zhang Xian Wang Bing-Qian Liu Ling Jin Yi-Nuo Huang Yang-Fan Yang Zi-Dong Chen Da-Hui Ma Qing-Shan Chen Chao-Jun Qin Bing-Min Feng Zhu-Min Yang Xing Huang Cheng-Jie Yang Sheng-Hui Liu Ming-Xing Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期528-536,共9页
●AIM:To evaluate the effectiveness and safety of early lens extraction during pars plana vitrectomy(PPV)for proliferative diabetic retinopathy(PDR)compared to those of PPV with subsequent cataract surgery.●METHODS:T... ●AIM:To evaluate the effectiveness and safety of early lens extraction during pars plana vitrectomy(PPV)for proliferative diabetic retinopathy(PDR)compared to those of PPV with subsequent cataract surgery.●METHODS:This multicenter randomized controlled trial was conducted in three Chinese hospitals on patients with PDR,aged>45y,with mild cataracts.The participants were randomly assigned to the combined(PPV combined with simultaneously cataract surgery,i.e.,phacovitrectomy)or subsequent(PPV with subsequent cataract surgery 6mo later)group and followed up for 12mo.The primary outcome was the change in best-corrected visual acuity(BCVA)from baseline to 6mo,and the secondary outcomes included complication rates and medical expenses.●RESULTS:In total,129 patients with PDR were recruited and equally randomized(66 and 63 in the combined and subsequent groups respectively).The change in BCVA in the combined group[mean,36.90 letters;95%confidence interval(CI),30.35–43.45]was significantly better(adjusted difference,16.43;95%CI,8.77–24.08;P<0.001)than in the subsequent group(mean,22.40 letters;95%CI,15.55–29.24)6mo after the PPV,with no significant difference between the two groups at 12mo.The overall surgical risk of two sequential surgeries was significantly higher than that of the combined surgery for neovascular glaucoma(17.65%vs 3.77%,P=0.005).No significant differences were found in the photocoagulation spots,surgical time,and economic expenses between two groups.In the subsequent group,the duration of work incapacity(22.54±9.11d)was significantly longer(P<0.001)than that of the combined group(12.44±6.48d).●CONCLUSION:PDR patients aged over 45y with mild cataract can also benefit from early lens extraction during PPV with gratifying effectiveness,safety and convenience,compared to sequential surgeries. 展开更多
关键词 lens extraction pars plana vitrectomy proliferative diabetic retinopathy CATARACT simultaneously operations
下载PDF
Endoscopy-assisted vitrectomy for severe ocular penetrating trauma with corneal opacity
9
作者 Yong-Zhen Yu Liu-Lian Jian +4 位作者 Wen-Xiao Chen Liang-Hong Peng Yu-Ping Zou Long Pang Xiu-Lan Zou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第12期2256-2264,共9页
AIM:To assess the utility and efficiency of endoscopyassisted vitrectomy(EAV)for the treatment of corneal opacity in severe ocular trauma.METHODS:Patients who underwent fundus examination using a preoperative slit lam... AIM:To assess the utility and efficiency of endoscopyassisted vitrectomy(EAV)for the treatment of corneal opacity in severe ocular trauma.METHODS:Patients who underwent fundus examination using a preoperative slit lamp and intraoperative endoscopy,followed by EAV and additional surgery were retrospectively recruited.Silicone oil removal and penetrating keratoplasty were used in selected eyes at postoperative follow-ups.Outcome measurements included the best corrected visual acuity(BCVA),intraocular pressure(IOP),findings of endoscopic fundus examination,and postoperative complications.RESULTS:Twenty-one eyes with severe ocular trauma and corneal opacity were followed up for 24-36mo.Retinal detachment(RD)and vitreous haemorrhage(VH)were identified in 16 eyes(76.2%),RD only in four eyes(19.0%),and VH combined with intraocular foreign body in one eye(4.8%).All eyes underwent at least three surgeries.Stage-Ⅰ surgeries involved wound closure(100%),lens extraction(76.2%),and anterior vitrectomy(14.3%).Stage-Ⅱ surgeries involved scleral buckling(28.6%),membrane peeling(47.6%),retinal laser photocoagulation(100%)and silicone oil tamponade(100%)using EAV.Stage-Ⅲ surgeries were conducted using endoscopy including silicone oil removal(52.4%),retinal laser photocoagulation(52.4%)and penetrating keratoplasty(28.6%).Nearly all eyes showed improvements in BCVA and IOP.Although there were no severe complications,glaucoma was noted in one eye,chronic hypotony in another eye,and band keratopathy in three eyes.CONCLUSION:EAV is an effective adjunct for restoring ocular anatomical structures and visual function in the case of corneal opacity after severe ocular trauma. 展开更多
关键词 corneal opacity endoscopy-assisted vitrectomy penetrating keratoplasty severe ocular trauma retinal detachment
下载PDF
Exploring the Mysteries of the Universe, and Innovation Leading the Future——Astronomical Techniques and Instruments
10
《Astronomical Techniques and Instruments》 CSCD 2024年第1期I0001-I0001,共1页
Dear Readers:Astronomical Techniques and Instruments is a professional English journal of open access devoted to recent develop-ments,discoveries,and theories in astronomical techniques,methods,and instruments.It will... Dear Readers:Astronomical Techniques and Instruments is a professional English journal of open access devoted to recent develop-ments,discoveries,and theories in astronomical techniques,methods,and instruments.It will serve as a platform for dis-course,learning,and information sharing for astronomic and astrophysics professionals worldwide. 展开更多
关键词 JOURNAL devoted instrumentS
下载PDF
Differential distribution of fibrovascular proliferative membranes in 25-gauge vitrectomy for proliferative diabetic retinopathy
11
作者 Nan Lu Shi-Lin Yang +6 位作者 Shuo Guo Dong-Ni Yang Li Liu Chun-Hui Fan Ying Guo Jian Liu Wei Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第8期1462-1468,共7页
AIM:To analyze the distribution of fibrovascular proliferative membranes(FVPMs)in proliferative diabetic retinopathy(PDR)patients that treated with pars plana vitrectomy(PPV),and to evaluate the outcomes separately.ME... AIM:To analyze the distribution of fibrovascular proliferative membranes(FVPMs)in proliferative diabetic retinopathy(PDR)patients that treated with pars plana vitrectomy(PPV),and to evaluate the outcomes separately.METHODS:This was a retrospective and cross-sectional study.Consecutive 25-gauge(25-G)PPV cases operated for PDR from May 2018 to April 2020.According to the FVPMs images outlined after operations,subjects were assigned into three groups:arcade type group,juxtapapillary type group,and central type group.All patients were followed up for over one year.General characteristics,operation-related variables,postoperative parameters and complications were recorded.RESULTS:Among 103 eyes recruited,the FVPMs distribution of nasotemporal and inferiosuperioral was significantly different(both P<0.01),with 95(92.23%)FVPMs located in the nasal quadrants,and 74(71.84%)in the inferior.The eyes with a central FVPM required the longest operation time,with silicon oil used in most patients,generally combined with tractional retinal detachment(RD)and rhegmatogenous RD,the worst postoperative bestcorrected visual acuity(BCVA)and the highest rates of recurrent RD(all P<0.05).FVPM type,age of onset diabetes mellitus,preoperative BCVA,and combined with tractional RD and rhegmatogenous RD were significantly associated with BCVA improvement(all P<0.05).Compared with the central type group,the arcade type group had higher rates of BCVA improvement.CONCLUSION:FVPMs are more commonly found in the nasal and inferior mid-peripheral retina in addition to the area of arcade vessels.Performing 25-G PPV for treating PDR eyes with central FVPM have relatively worse prognosis. 展开更多
关键词 proliferative diabetic retinopathy fibrovascular proliferative membrane 25-gauge pars plana vitrectomy
下载PDF
Investigation and analysis of negative emotion in patients with diabetic retinopathy after vitrectomy
12
作者 Zhi-Heng Ju Mei-Ju Wang 《World Journal of Psychiatry》 SCIE 2024年第10期1513-1520,共8页
BACKGROUND As the incidence of diabetes continues to increase,the number of patients with diabetic retinopathy(DR)also increases each year.After undergoing vitrectomy for DR,patients often experience negative emotiona... BACKGROUND As the incidence of diabetes continues to increase,the number of patients with diabetic retinopathy(DR)also increases each year.After undergoing vitrectomy for DR,patients often experience negative emotional problems that negatively affect their recovery.AIM To investigate negative feelings in patients with DR after vitrectomy and to explore related influencing factors.METHODS A total of 146 individuals with DR who were accepted for treatment at The Third People’s Hospital of Changzhou from May 2021 to April 2023 were recruited to participate in this study.All patients underwent vitrectomy.The self-rating anxiety scale(SAS)and self-rating depression scale(SDS)were used to assess the degree of anxiety and depression 2-3 days after the operation.The participants were divided into a healthy control group and a negative emotion group.The patients’general demographic characteristics and blood glucose levels were collected.Logistic regression analysis was used to analyze the factors influencing negative feelings post-operation.Pearson’s correlation coefficient was used to analyze the association between SAS scores,SDS scores,and blood glucose levels.RESULTS The control group included 85 participants.The negative emotion group comprised 40 participants with anxiety,13 with depression,and eight with both.Logistic regression showed that being female(OR=3.090,95%CI:1.217-7.847),a family per capita monthly income of<5000 yuan(OR=0.337,95%CI:0.165-0.668),and a longer duration of diabetes(OR=2.068,95%CI:1.817-3.744)were risk factors for negative emotions in patients with DR after vitrectomy(P<0.05).The concentrations of fasting plasma glucose(FPG),2-hour postprandial glucose(2hPG),and glycated hemoglobin(HbA1c)in the negative emotion group exceeded those in the control group(P<0.05).SAS scores were positively associated with FPG(r=0.422),2hPG(r=0.334),and HbA1c(r=0.362;P<0.05).SDS scores were positively correlated with FPG(r=0.218)and 2hPG(r=0.218;P<0.05).CONCLUSION Sex,income level,and duration of diabetes were factors that influenced negative emotions post-vitrectomy.Negative emotions were positively correlated with blood glucose levels,which can be used to develop intervention strategies. 展开更多
关键词 Diabetic retinopathy vitrectomy ANXIETY DEPRESSION Blood glucose levels Risk factors
下载PDF
Effects of vitrectomy combined with internal limiting membrane peeling in patients with diabetic macular edema
13
作者 Lei Wang Chun-Jie Chen +2 位作者 Ming-Li Wang Yong Huang Li-Jian Fang 《World Journal of Clinical Cases》 SCIE 2024年第21期4491-4498,共8页
BACKGROUND Diabetic macular edema(DME),a chronic microvascular complication of diabetes,is a leading cause of visual impairment and blindness.Pars plana vitrectomy(PPV)can restore the normal macular structure and redu... BACKGROUND Diabetic macular edema(DME),a chronic microvascular complication of diabetes,is a leading cause of visual impairment and blindness.Pars plana vitrectomy(PPV)can restore the normal macular structure and reduce macular edema,whereas internal limiting membrane(ILM)peeling is used to treat tractional macular diseases.Despite the advantages,there is limited research on the combined effects of PPV with ILM peeling.AIM To observe the effects of PPV combined with ILM peeling on postoperative central macular thickness(CMT),best-corrected visual acuity(BCVA),cystoid macular edema(CME)volume,and complications in patients with DME.METHODS Eighty-one patients(92 eyes)diagnosed with DME at the Beijing Shanqu Liangxiang Hospital between January and December 2022 were randomly divided to undergo PPV alone(control group:41 patients,47 eyes)or PPV+ILM peeling(stripping group:40 patients,45 eyes);a single surgeon performed all surgeries.The two groups were compared preoperatively and 1 and 3 months postoperatively.RESULTS Preoperatively,both groups had comparable values of CMT,BCVA,and CME volume(P>0.05).After surgery(both 1 and 3 months),both groups showed significant reductions in CMT,BCVA,and CME volume compared to preoperative levels,with the stripping group showing more significant reductions compared to the control group(P<0.05).Further repeated-measures ANOVA analysis for within-group differences revealed significant effects of group and time,and interaction effects for CMT,BCVA,and CME volume(P<0.05).There were no significant differences in the incidence of complications between the groups(retinal detachment:control=2,stripping=1;endophthalmitis:Control=4,stripping=1;no cases of secondary glaucoma or macular holes;χ^(2)=0.296,P=0.587).CONCLUSION PPV with ILM peeling can significantly improve the visual acuity of patients with DME,reduce CMT,and improve CME with fewer complications. 展开更多
关键词 vitrectomy Internal limiting membrane peeling Diabetic macular edema Central macular thickness Bestcorrected visual acuity COMPLICATIONS
下载PDF
Pharmacological adjuvants for diabetic vitrectomy surgery
14
作者 Ramesh Venkatesh Chaitra Jayadev +5 位作者 Vishma Prabhu Priyanka Gandhi Rupal Kathare Naresh K Yadav Ayushi Choudhary Jay Chhablani 《World Journal of Methodology》 2024年第4期84-90,共7页
Diabetic vitrectomy is a highly intricate surgical procedure performed during the advanced stages of diabetic retinopathy(DR).It is used to treat conditions such as tractional or combined retinal detachment,vitreous h... Diabetic vitrectomy is a highly intricate surgical procedure performed during the advanced stages of diabetic retinopathy(DR).It is used to treat conditions such as tractional or combined retinal detachment,vitreous hemorrhage,and subhyaloid hemorrhage,which are all severe manifestations of proliferative DR.The results of the surgery are uncertain and variable.Vitreoretinal surgery has made significant progress since the early stages of vitrectomy.In the past ten years,advancements in intravitreal pharmacotherapy have emerged,offering new possibilities to improve the surgical results for our patients.Within the realm of medical terminology,an"adjunct"refers to a pharmaceutical or substance employed to aid or expedite the primary therapeutic intervention for a particular ailment.Their introduction has broadened the range of therapeutic choices that are accessible prior to,during,and following surgical procedures.This review article will specifically analyze the pharmacological adjuncts used in diabetic vitrectomy surgery,with a focus on their role in facilitating or aiding specific steps of the procedure.The implementation of this system of categorization offers benefits to the surgeon by allowing them to foresee potential difficulties that may occur during the surgical procedure and to choose the appropriate pharmacological agent to effectively tackle these challenges,thus enhancing surgical success rates. 展开更多
关键词 Diabetic retinopathy vitrectomy Intravitreal injections Anti-vascular endothelial growth factor ADJUVANTS OUTCOMES
下载PDF
Reform of Teaching Practice of Modern Instrumental Analysis in Biotechnology Programs
15
作者 Kun TANG Tong LIN +3 位作者 Zhenxia SHI Jie QIAO Chunyan XIE Lixin DU 《Agricultural Biotechnology》 2024年第3期93-95,共3页
Through the online and offline practical reform of the Modern Instrumental Analysis course of biotechnology majors from teaching content,teaching method,teaching demonstration to teaching effect,the traditional single... Through the online and offline practical reform of the Modern Instrumental Analysis course of biotechnology majors from teaching content,teaching method,teaching demonstration to teaching effect,the traditional single offline lecture is transformed into diversified and interactive modern teaching.The practical reform enriches and optimizes the course content,perfects and improves the course assessment system,and improves the teaching quality.It achieves the student-centered and application-oriented teaching goal,and also provides reference for further cultivating high-quality applied talents. 展开更多
关键词 Modern instrumental analysis BIOTECHNOLOGY Online and offline Reform of teaching
下载PDF
Development and validation of an instrument to assess knowledge,attitudes,and practices on digital health among nursing officers
16
作者 Maheshika Madhuwanthi Sunethra Jayathilake +1 位作者 Neranga Liyanaarachchige Rohana Marasinghe 《Frontiers of Nursing》 2024年第3期275-284,共10页
Objective:Validation is an important aspect of an instrument,and it ensures the confidence of researchers to employ the instrument in their studies.This study was conducted to develop and validate an instrument to ass... Objective:Validation is an important aspect of an instrument,and it ensures the confidence of researchers to employ the instrument in their studies.This study was conducted to develop and validate an instrument to assess knowledge,attitudes,and practices(KAP) on digital health among nurses since digital health capacity is a major concern in health care that needs to be assessed.Methods:We conducted a methodological study to assess the content validity and reliability of the instrument.First,items were generated through a comprehensive literature review and by obtaining an expert opinion.Second,content and face validity were assessed by a panel of 7 experts.Both the item-level content validity index(I-CVI) and the scale-level content validity index(S-CVI) were established.Moreover,test–retest reliability and internal consistency of the instrument were assessed.Data were analyzed using SPSS version 25.Results:The initial pool consisted of 60 items and after obtaining content,face,and construct validity,51 items remained.Items with an I-CVI <0.78 were considered relevant.The S-CVI for relevancy,clarity,ambiguity,and simplicity were 0.93,0.91,0.94,and 0.92,respectively.Five subcomponents were constructed in each knowledge and attitudes domain,and the test–retest reliability test revealed that the instrument has good reliability,showing correlation coefficient values for the KAP domains and the total questionnaire of 0.76,0.98,0.99,and 0.99,respectively.The independent Cronbach's α for all items was 0.76,indicating good internal consistency.Conclusions:The present study established the acceptable validity and ensured the good reliability and internal consistency of the instrument,which can serve as an assessment tool of KAP on digital health among healthcare professionals. 展开更多
关键词 assess DEVELOPMENT DIGITAL HEALTH instrument validations
下载PDF
Analysis Of Urban Planning Instruments in Comala,Colima,Mexico(1997-2009)from a Gender Perspective-A Secondary Publication
17
作者 E.J.García Espíritu P.Chung Alonso +2 位作者 I.BarajasÁvalos M.S.R.Covarrubias Ruesga M.P.Ramírez Rivera 《Journal of Architectural Research and Development》 2024年第1期93-101,共9页
This work is carried out based on the analysis of urban planning instruments,taking the gender perspective as a foundation.It arises from the inclusion of women in the participation of urban development,through an ana... This work is carried out based on the analysis of urban planning instruments,taking the gender perspective as a foundation.It arises from the inclusion of women in the participation of urban development,through an analysis of the gender gaps that have marked the history of women,the inequalities serve as a basis for carrying out this study.It highlights the challenges we face today as a society in the process of building citizen participation,where we must all be recognized and have equal opportunities within the territory in which we live.This article analyzes the extent to which the Municipal Urban Development Programs of the Mexican municipality of Comala,Colima,Mexico,consider the recommendations on gender and urbanism,established since the 1990s by international entities and applied transversally to urban planning policies.Considerable differences are found between women and men in terms of empowerment and participation in urban territorial planning instruments,mainly in the oldest instrument(1997).Significant progress is observed in the most recent document and is currently in force in the municipality of Comala(2009). 展开更多
关键词 Planning instruments Gender perspective Urban planning
下载PDF
Instrument Automation Control System Faults and Maintenance
18
作者 Jianwei Li 《Journal of Electronic Research and Application》 2024年第1期16-21,共6页
This article explores the topic of fault diagnosis and maintenance strategies for instrument automation control systems,analyzing them through specific cases.The aim of this research is to improve the stability and re... This article explores the topic of fault diagnosis and maintenance strategies for instrument automation control systems,analyzing them through specific cases.The aim of this research is to improve the stability and reliability of the system by conducting a thorough investigation of faults and maintenance in instrument automation control systems.By doing so,this research hopes to provide a strong guarantee for the smooth progress of industrial production. 展开更多
关键词 instrument automation Control system failure Maintenance
下载PDF
Design of Signal Lamp Filament Monitoring Alarm Instrument
19
作者 Haifeng Zhu 《Journal of Electronic Research and Application》 2024年第5期38-45,共8页
To improve the reliability of the light emitting diode(LED)signal lamp filament current monitoring alarm instrument for metro systems,a new type of hot standby online monitoring apparatus was developed which is based ... To improve the reliability of the light emitting diode(LED)signal lamp filament current monitoring alarm instrument for metro systems,a new type of hot standby online monitoring apparatus was developed which is based on synchronous transmission data(STD)bus technology.In this system,a double hot standby mode can be achieved by adopting bus arbitration.In addition,to detect the effective value of alternating current which is from 0 to 200 mA in the signal lamp lighting circuit,a precision rectifier signal conditioning circuit and an isolated acquisition circuit were designed.This new type of alarm instrument has high detection accuracy and could meet the functional requirements for metro signal systems after comparing it with some industry products that were applied on the spot. 展开更多
关键词 Signal lamp Monitoring alarm instrument Precision rectifier signal conditioning circuit
下载PDF
浅析AVEVA Instrumentation在仪表设计中的应用
20
作者 齐桂卿 李海寿 +1 位作者 刘鸿雁 崔胜 《仪器仪表用户》 2023年第2期107-112,共6页
设计领域数字化转型是产业数字化的重要方向,各种专业设计软件强大的数据存储和处理能力,可以为制造业数字化转型提供大量的数据源。为了借助各种专业软件实现业务需求及数据需求,需要对各种专业设计软件进行大量的二次开发工作。AVEVA... 设计领域数字化转型是产业数字化的重要方向,各种专业设计软件强大的数据存储和处理能力,可以为制造业数字化转型提供大量的数据源。为了借助各种专业软件实现业务需求及数据需求,需要对各种专业设计软件进行大量的二次开发工作。AVEVA系列软件作为石化行业主流设计软件,对于设计领域的数字化转型尤为重要。本文基于海上石油平台仪表设计的工作流程,从仪表专业设计的角度分析了AVEVA INSTRUMENTION的各个功能模块及其在相关专业间的协同设计应用,重点探讨围绕VEVA INSTRUMENTION各功能模块进行的规则库、属性库、材料目录库等标准数据库的开发,经导航项目测试效果良好,为海洋工程设计领域的数字化转型奠定了良好的基础,也为后续的实际项目应用及二次开发具有一定的借鉴作用。 展开更多
关键词 AI软件 功能模块 规则库 属性库 材料目录库
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部